Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.2 LAccepted-AOC | L-1 | Accepted-AOC Lowest Tenderer | |
| 2 | L-2₹25.0 L+₹2.8 L (12.5%)Rejected-Finance | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹26.9 L+₹4.7 L (21.4%)Rejected-Finance | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹28.4 L+₹6.2 L (28.1%)Rejected-Finance 0 GHULAM MOHAMMAD AND CO 0 GURUDAWARA II RAWALPORA SRINAGAR JAMMU AND KASHMIR RAWALPORA SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹28.8 L+₹6.6 L (29.8%)Rejected-Finance | L-5 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | FG CONSTRUCTION L9 | IR Infrastructure L8 | M/S M.R. Construction L2 | M/S TARIQ AHMAD SHEIKH L7 | M/S SA INFRATECH L6 | M/S FAROOQ AND SONS L1 | M/S NAIK CONSTRUCTION COMPANY L5 | M/S GHULAM MOHAMMAD AND CO. L4 | M/s PARVAZ CONSTRUCTION COMPANY L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for septic tank for (50 users) in soft / dense soil, size 4.0m length, 1.40m breadth, 1.60m depth, single chamber with thickness of slab 100mm and RCC baffle wall of thickness 80mm complete all as per detail of reinforcement and drawing as mentioned in TD Drg No CE/AF/STD-15/2000 Sheet No. 1/2 and 2/2 dated 05 Jan 2000, with foundation in PCC 1:2:4, brickwork and plaster in CM 1:4 with using sub class 'B' old size brick, RCC slab covers including RCC Precast Manhole cover having 6mm plate embedded all around / fibre reinforced cover with angle iron frame vent shaft and sludge chambers etc. including form work excavation, returning filling, removal of ecavated material and site clearance, complete all as specified and directed. | 12 | Each | 60,000 ₹7,20,000 | 1,25,000 ₹15,00,000 | 53,000 ₹6,36,000 | 60,000 ₹7,20,000 | 88,000 ₹10,56,000 | 29,000 ₹3,48,000 Lowest | 90,000 ₹10,80,000 | 55,000 ₹6,60,000 | 55,000 ₹6,60,000 |
| 2.00 | M&L for soakage pit / well for (50 users) in soft / loose soil, size 3.00m dia and 3.50m depth, PCC 1:3:6 in foundation, 150mm thick , walls of honeycombed brick work with CM 1:4 with sub class 'B' old size brick, PCC bend using 1:2:4 concrete at every 1.00 height, 115mm thickness of brickwork work should be increased at every 0.75m depth and filling brick bats in the wall upto 2.00m height and provide 100mm thick RCC Slab of M-25 grade concrete including intercepting / screen chamber, complete all as specified in TD Drg No CE/AF/STD-15/2000 Sheet No. 1/2 and 2/2 dated 05 Jan 2000 including form work, excavation, returning filling, complete all as specified and directed. | 10 | Each | 45,000 ₹4,50,000 | 22,000 ₹2,20,000 Lowest | 47,000 ₹4,70,000 | 78,000 ₹7,80,000 | 56,000 ₹5,60,000 | 40,000 ₹4,00,000 | 60,000 ₹6,00,000 | 40,000 ₹4,00,000 | 60,000 ₹6,00,000 |
| 3.00 | Supply, installation, testing & commissioning LLDPE septic tank for 16 users WITH UPFLOW FILTER INCLUDING MEDIA of size 2000mm dia and 2250mm height with 115mm dia inlet pipe and supply & fix 150mm dia DWCPE pipe of length as required (will be paid in respected Item in BOQ) for connecting septic tank to soakage Pit & 50mm dia PVC vent pipe fixed in position and connection with inlet outlet & vent pipe as per manufacturer instruction, complete all as specified and directed. | 8 | Each | 1,90,000 ₹15,20,000 | 50,000 ₹4,00,000 | 40,000 ₹3,20,000 | 35,000 ₹2,80,000 | 65,000 ₹5,20,000 | 26,000 ₹2,08,000 Lowest | 55,000 ₹4,40,000 | 75,000 ₹6,00,000 | 44,500 ₹3,56,000 |
| 4.00 | M&L for soakage pits / well for (16 users) in soft / loose soil size 2.20m dia and 2.50m depth PCC 1:3:6 in foundation 150mm thick walls of honeycombed brick work with CM 1:4 with sub class 'B' old size brick PCC bend using 1:2:4 concrete at every 1.00m height 115mm thickness of brickwork work should be increased at every 0.75m depth and filling brick bats in the wall upto 2.00m height and provide 100mm thick RCC Slab of M-25 grade concrete including intercepting/ screen chamber complete all as specified in TD Drg No CE/AF/STD-15/2000 Sheet No 1/2 and 2/2 dated 05 Jan 2000 Including form work, excavation, returning filling, complete all as specified and directed. | 8 | Each | 40,000 ₹3,20,000 | 17,000 ₹1,36,000 | 32,000 ₹2,56,000 | 75,000 ₹6,00,000 | 45,000 ₹3,60,000 | 33,000 ₹2,64,000 | 8,000 ₹64,000 Lowest | 40,000 ₹3,20,000 | 42,000 ₹3,36,000 |
| 5.00 | Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft / loose soil, complete all as specified and directed. | 446 | Cubic Metre | 120 ₹53,520 | 130 ₹57,980 | 50 ₹22,300 Lowest | 200 ₹89,200 | 50 ₹22,300 Lowest | 100 ₹44,600 | 200 ₹89,200 | 100 ₹44,600 | 150 ₹66,900 |
| 6.00 | M&L for plain cement concrete, 1:4:8, Type D-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed. | 26 | Cubic Metre | 3,000 ₹78,000 | 4,000 ₹1,04,000 | 2,000 ₹52,000 Lowest | 4,500 ₹1,17,000 | 2,000 ₹52,000 Lowest | 3,500 ₹91,000 | 2,000 ₹52,000 Lowest | 3,000 ₹78,000 | 2,500 ₹65,000 |
| 7.00 | S&F 150mm bore, HDPE double wall corrugated Pipe in any length with rubber ring joints, laid in trenches for sewage pipe with PCC packing under hunching and bedding, complete all as specified and directed. | 425 | Running Metre | 350 ₹1,48,750 | 200 ₹85,000 | 350 ₹1,48,750 | 180 ₹76,500 | 375 ₹1,59,375 | 300 ₹1,27,500 | 150 ₹63,750 Lowest | 350 ₹1,48,750 | 200 ₹85,000 |
| 8.00 | S&F 200mm bore, HDPE double wall corrugated Pipe in any length with rubber ring joints, laid in trenches for sewage pipe with PCC packing under hunching and bedding, complete all as specified and directed. | 175 | Running Metre | 390 ₹68,250 | 280 ₹49,000 | 450 ₹78,750 | 250 ₹43,750 | 400 ₹70,000 | 350 ₹61,250 | 200 ₹35,000 Lowest | 390 ₹68,250 | 330 ₹57,750 |
| 9.00 | M&L for concrete bed to 150mm bore drain pipes including packing under, and haunchings against the sides of pipes after they are laid in cement concrete, 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) and tested, complete all as specified & directed. | 400 | Running Metre | 100 ₹40,000 | 200 ₹80,000 | 100 ₹40,000 | 280 ₹1,12,000 | 95 ₹38,000 | 100 ₹40,000 | 120 ₹48,000 | 90 ₹36,000 Lowest | 100 ₹40,000 |
| 10.00 | M&L for concrete bed to 200mm bore drain pipes including packing under, and haunchings against the sides of pipes after they are laid in cement concrete, 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) and tested, complete all as specified & directed. | 150 | Running Metre | 125 ₹18,750 | 200 ₹30,000 | 120 ₹18,000 | 380 ₹57,000 | 105 ₹15,750 | 120 ₹18,000 | 150 ₹22,500 | 120 ₹18,000 | 100 ₹15,000 Lowest |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
15 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Srinagar
Garrison Engineer (AF) Air Force Station Srinagar 190 007
PROVISION OF SEPTIC TANKS AND SOKAGE PITS AT CERTAIN LOCATIONS UNDER GE (AF) SRINAGAR
2025_MES_727679_1
GE (AF)/SGR-48/2025-26
Open Tender
Civil Works
Item Rate
180 days
AOR of GE (AF) Srinagar
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Srinagar
₹87,200
Yes
18 Oct 2025
25 Aug 2025
17 Sept 2025
25 Aug 2025
15 Sept 2025
8 Sept 2025
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .