Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.4 LAccepted-AOC DAKRA RANCHI PIN 829201 | CHATRA | JHARKHAND | 829201 | ₹23.4 L | 1 | Accepted-AOC Evaluated as L1 bidder |
| 2 | Rejected-Technical 00 C O LAKHAN LAL AGRAWAL RATU ROAD NEAR KABLISTHAN RANCHI JHARKHAND 834001 UDYAM JH 20 0002559 | RANCHI | JHARKHAND | 834001 | - | - | Rejected-Technical Submitted documents checked and found NOT satisfactory as per NIT |
| 3 | Rejected-Technical 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | - | - | Rejected-Technical Submitted documents checked and found NOT satisfactory as per NIT |
| Sl No | Description | Qty | Unit | M/S DHARMENDRA KUMAR SINGH L1 |
|---|---|---|---|---|
| 1.01 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductor single core cable in surface/Recessed PVC conduit, with Modular type Switch, phenolic laminated sheet, Suitable size M.S box and earthing the Point with 1.5sqmm. FR PVCinsulated Copper conductor single core cable etc. as required. (Group –“C”) for (7 points x26)=182 nos | 182 | nos. | 1,170.18 ₹2.1 L |
| 1.02 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductor single core cable in surface/Recessed PVC conduit, with Modular type Switch, phenolic laminated sheet, Suitable size M.S box and earthing the Point with 1.5sqmm. FR PVCinsulated Copper conductor single core cable etc. as required. (Group –“B”) for ( 7 points x15 ) + ( 6points x41 )=351 nos | 351 | nos. | 947.43 ₹3.3 L |
| 1.03 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVCConduit as required (2x1.5Sq.mm+ 1.5sq.mm earth wire) ( 18 mtr x 41 )= 738 mtr | 738 | Mtrs. | 188.1 ₹1.4 L |
| 1.04 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVCConduit as required (2x2.5Sq.mm+ 2.5sq.mm earth wire) for (23 mtr x 41)= 943mtr | 943 | Mtrs. | 224.73 ₹2.1 L |
| 1.05 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (100 mm X 100 mm X 60 mm deep) for ( 3 nos x 41 )= 123 nos | 123 | nos. | 164.34 ₹20,213.82 |
| 1.06 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 150 mm X 60 mm deep for ( 4 nos x 41 )= 164 nos | 164 | nos. | 285.12 ₹46,759.68 |
| 1.07 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 250 mm X 60 mm deep for ( 2 nos x 41 )= 82 nos | 82 | Nos. | 380.16 ₹31,173.12 |
| 1.08 | Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. (5/6 Amp Switch) for ( 4 nos x 41 )=164 nos | 164 | No. | 82.17 ₹13,475.88 |
| 1.09 | Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. (15/16 Amp Switch) for ( 3 nos x 41 )=123 nos | 123 | No. | 127.71 ₹15,708.33 |
| 1.10 | Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. (5/6 Amp Socket Outlet) for ( 4 nos x 41 )=164 nos | 164 | Nos. | 100.98 ₹16,560.72 |
Tender Value
₹23.6 L
EMD Value
₹30,000
Closing Date
27 Jan 2026, 4:00 pmClosed
Staff Officer(ENM),Kathara Area
Staff Officer(EnM) Kathara Area GM office, EnM Dept , GM Unit Kathara Area,CCL P.O Kathara Dist Bokaro
CAMC for day to day Internal electrical repair/maintenance of partial rewiring with switch board, switches, socket outlet, MCB board,main switch, service wire and earth pit etc at different type of Officer Qtrs as Russian Colony, Officer Col
2026_CCL_351135_1
GM(KTA)/SO(ENM)/GMU/E Tender/2025-26/29 Date 12.01.2026
Open Tender
Electrical and Maintenance Works
730 days
GM Unit Kathara Area, CCL P.O Kathara Dist Bokaro
As Per NIT
5 documents required · 5 mandatory
₹30,000
25 Mar 2026
13 Jan 2026
28 Jan 2026
14 Jan 2026
27 Jan 2026
14 Jan 2026
14 Jan 2026 - 24 Jan 2026
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductor single core cable in surface/Recessed PVC conduit, with Modular type Switch, phenolic laminated sheet, Suitable size M.S box and earthing the Point with 1.5sqmm. FR PVCinsulated Copper conductor single core cable etc. as required. (Group –“C”) for (7 points x26)=182 nos
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductor single core cable in surface/Recessed PVC conduit, with Modular type Switch, phenolic laminated sheet, Suitable size M.S box and earthing the Point with 1.5sqmm. FR PVCinsulated Copper conductor single core cable etc. as required. (Group –“B”) for ( 7 points x15 ) + ( 6points x41 )=351 nos
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVCConduit as required (2x1.5Sq.mm+ 1.5sq.mm earth wire) ( 18 mtr x 41 )= 738 mtr
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVCConduit as required (2x2.5Sq.mm+ 2.5sq.mm earth wire) for (23 mtr x 41)= 943mtr
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (100 mm X 100 mm X 60 mm deep) for ( 3 nos x 41 )= 123 nos
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 150 mm X 60 mm deep for ( 4 nos x 41 )= 164 nos
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 250 mm X 60 mm deep for ( 2 nos x 41 )= 82 nos
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. (5/6 Amp Switch) for ( 4 nos x 41 )=164 nos
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. (15/16 Amp Switch) for ( 3 nos x 41 )=123 nos
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. (5/6 Amp Socket Outlet) for ( 4 nos x 41 )=164 nos
Supplying and fixing following modular switch/Socket on the existing modular plate switch box/cover including connections but excluding modular plate etc. as required. (15/16 Amp Socket Outlet) for ( 3 nos x 41 )=123 nos
Supplying and fixing of modular type electronic regulator Supplying & fixing stepped type electronic fan type regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required. for ( 4nos x 41 )=164 nos
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLSont including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps modular type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).COST FOR EACH ( 5 nos x 41 )=205 nos
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLSont including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps modular type switch, connection, painting etc. as required.COST for EACH ( 2 nos x 41 )=82 nos
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. ( 6 nos x 41 )=246 nos
Supplyingand fixingPVC batten/ angle holder including connections etc as required. ( 7nos x 41 )=287 nos
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Details of cost for each mtr ( 9 nos x 41 )=369 mtr
Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7mtr. long etc. with charcoal/coke and salt asrequired. ( 1 no x 41 )=41 nos
Supplying and fixing following rating, fourpole, (three phaseandneutral),415volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( 1 nos x 41 )=41 nos
Providing of 4 sqmm PVC copper cable with two core conductor core type. Unarmoured cable For sevice connection ( 30 mtr x 41 )=1230 mtr
Laying of one number PVC insulatedand PVC sheathed /XLPE powercable of 1.1 KV grade of following size in the existing RCC/ HUME/METAL pipeas required. ( 30 mtr x 41 )=1230 mtr
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 A TP&N. ( 1 nos x 41 )=41 nos
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required ( 4 nos x 41 )=164 nos
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB /Isolator) 6 way, Double door . for ( 1 nos x 41 )=41 nos
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.45 MB
BOQ_363883.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid