Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.3 LAccepted-Finance | ₹81.3 L | L1 | Accepted-Finance ok |
| 2 | L2₹1.0 Cr+₹22.7 L (27.9%)Rejected-Finance | ₹1.0 Cr+₹22.7 L (27.9%) | L2 | Rejected-Finance ok |
| 3 | Rejected-Technical | - | - | Rejected-Technical ok |
| 4 | Rejected-Technical SHOP NO 5 BACHAT BHAWAN UNA TEHSIL UNA HP 174303 | UNA | UNA | HP | 174303 | - | - | Rejected-Technical ok |
| 5 | Rejected-Technical GROUND FLOOR THAKUR COMPLEX BASANTPUR | BASANTPUR | SHIMLA | HIMACHAL PRADESH | 171018 | - | - | Rejected-Technical ok |
Tender Value
₹98.1 L
EMD Value
₹2.0 L
Closing Date
20 Jan 2026, 2:00 pmClosed
XEN Electrical Division No. 1 Shimla
he Executive Engineer Electrical Division No-1 HPPWD Shimla-9
Providing Facade lights to HP. Vidhan Sabha Complex at Shimla-4.
2026_PWD_125697_1
Electrical Division-I dated 14.01.2026
Open Tender
Electrical Works
Percentage
30 days
SHIMLA
As per bidding document
16 documents required · 16 mandatory
₹5,000
₹2.0 L
3 Mar 2026
14 Jan 2026
21 Jan 2026
14 Jan 2026
20 Jan 2026
14 Jan 2026
Design, Supply, installation, testing & commissioning of outdoor BIS registered RGBW Linear LED Wall Washer luminaire for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness and die casted end caps, of Total System wattage not exceeding 60W. Total System lumens not less than 3600 Lumens. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens m offering beam angle of different types such as narrow, medium.SDCM<3. Beam angle 10,25,40 ,18*35 degree.as per site requirement Fixture length should not be more than 1000 mm with constant locking hinges for simple position control from various angles without special tools. DMX enabler circuit should be inside the Luminaire only. Operating voltage range 100 -300 V AC. Potted IP67 electronic LED driver with APFC, lower THD, Open Circuit Protection, Over Voltage Protection ,Surge Voltage Protection upto 10kV with SPD & other safety test as per IS 15885 Part-2/ Sec 13, IEC60598-1..Operating voltage range 100 -300 V AC. Fixture shall be suitable to operate at an ambient temperature range of -20°C to 50°C and complete luminaire shall be IP66 and IK07 rated. SDCM < 5. CRI >80. LED Life time shall be at least L70B50 @ 50000 burning hours at +50°C. .The BIS certificate should show factory name as same name of the OEM The Luminaire should be BIS approved and BIS /LM79/LM80 mandatory during tender submission. DMX Male/ Female/Extension cables/Junction box should be included. Equvilent to Havells COLORLINEV1LS60WLEDRGBWP or equvilent in Signify ColorKinetics GLAZE / Wipro ARCUS - LF01-671-15-CC-G2, with 5year on site warranty.
Design, Supply, installation, testing & commissioning of outdoor BIS registered RGBW Linear LED Wall Washer luminaire for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness and die casted end caps, of Total System wattage not exceeding 80W.Total System lumens not less than 4800 Lumens. SDCM<3. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture length should not be more than 1000 mm with constant locking hinges for simple position control from various angles without special tools. DMX enabler circuit should be inside the Luminaire only.Potted IP67 electronic LED driver with APFC, lower THD, Open Circuit Protection, Over Voltage Protection ,Surge Voltage Protection upto 10kV with SPD & other safety test as per IS 15885 Part-2/ Sec 13, IEC60598-1. Case temperature i.e. Tc > 90°C. Beam angle 10,25,40 ,18*35 degree.as per site requirement. Fixture shall be suitable to operate at an ambient temperature range of -20°C to + 50°C and complete luminaire shall be IP66 and IK07 rated. SDCM < 5. CRI >80. LED Life time shall be at least L70B50 @ 50000 burning hours .Operating voltage range 100 -300 V AC. All accesaries included. DMX MALE & FEMALA SUPPLY CABLE 1M 4 PIN, DMX EXTENSION CABLE 3M & 1M 4 PIN.The BIS certificate should show factory name as same name of the OEM The Luminaire should be BIS approved and BIS /LM79/LM80 mandatory during tender submission.DMX Male/Female/Extension cables should be included. Mak:- Havells COLORLINEV1LS80WLEDRGBWP- or equvilent in Signify ColorKinetics GLAZE / Wipro ARCUS LF01-122-15-CC-G2, with 5year on site warranty.
Design, Supply, installation, testing & commissioning of Outdoor BIS registered RGB Flexible LED Strip with 7.2 Watt per meter. LED Strip should have 30Nos LEDs per meter through out the length with the silicon cover with system lumens System Lumen Efficacy 20lm/w. Standard Length of LED Strip is 5 mtr and it shall be capable of producing dynamic color changing light for with 16 million colors and should be programmable using 8 bit control DMX512 protocol / Ethernet based control. The Strip should have IP 67 protection with inbuilt IP67 connectors at both ends. DMX enabler circuit should be outside the Luminaire/LED Strip only. LED Strip shall be suitable to operate at an ambient temperature range of -20°C to 50°C. . The rated voltage of the Luminaire should be 24VDC, Luminaire shall be offered with a BIS Approved Potted Driver of IP 67 rating made of extruded aluminium to make it more thermal efficient, Led Driver should have PF > 0.95 , Led driver must have SELV output and Case temperature i.e. Tc > 90°C. Aluminium channel included. All accessaries included.DMX DECODER_RGBW_12V/24V_480W, Instruction Forwarder Ranger/Compass(AC) / Strip, 1 Mtr wire 5pin IP67 Female Connector RGBW , 5M EXTENSION WIRE 5PIN IP67 RGBW). The Luminaire should be BIS approved To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Make:- Havells - Flexistrip36WDMX or equvilent in Signify ColorKinetics FLEX COMPACT GEN3, RGB/Wipro ARCUS LS27-14-TB16-CCWG1, with 5year on site warranty.
Design, Supply, installation, testing & commissioning of Outdoor BIS registered RGBW Linear LED Wall Washer luminaire for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness and die casted end caps, of Total System wattage not less than 25W. Total System lumens not less than 1500 Lumens.SDCM<3. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens m offering beam angle of different types such as narrow, medium.. Beam angle 10,25,40 ,18*35 degree.as per site requirement Fixture length should not be more than 1000 mm with constant locking hinges for simple position control from various angles without special tools. DMX enabler circuit should be inside the Luminaire only. Operating voltage range 100 -300 V AC.Potted IP67 electronic LED driver with APFC, lower THD, Open Circuit Protection, Over Voltage Protection ,Surge Voltage Protection upto 10kV with SPD & other safety test as per IS 15885 Part-2/ Sec 13, IEC60598-1.Operating voltage range 100 -300 V AC. Fixture shall be suitable to operate at an ambient temperature range of -20°C to 50°C and complete luminaire shall be IP66 and IK07 rated. SDCM < 5. CRI >80. LED Life time shall be at least L70B50 @ 50000 burning hours at +50°C.The BIS certificate should show factory name as same name of the OEM The Luminaire should be BIS approved and BIS /LM79/LM80 mandatory during tender submission.DMX Male/Female/Extension cables should be included. Make:- Havells COLORLINEV1LS25WLEDRGBWP- or equivilent in Signify Signify ColorKinetics GLAZE /Wipro ARCUS LF04-361-15-CC-G2, with 5year on site warranty.
Design, Supply, installation, testing & commissioningof Outdoor of exterior BIS registered RGBW Projector Light luminaire for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness and die casted end caps, of Total System wattage not less than 100W. Total System lumens not less than 5000 Lumens. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens m offering beam angle of different types such as narrow, medium.. Beam angle 10,25,40 ,18*35 degree.as per site requirement. DMX enabler circuit should be inside the Luminaire only. Operating voltage range 100 -300 V AC. Built-In Potted IP67 electronic LED driver with APFC,lower THD, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10 kV with SPD & other safety test as per IS 15885 Part-2/ Sec 13, IEC60598-1.Operating voltage range 100 -300 V AC. Fixture shall be suitable to operate at an ambient temperature range of -20°C to 50°C and complete luminaire shall be IP66 and IK07 rated. SDCM < 3. CRI >80. LED Life time shall be at least L70B50 @ 70000 burning hours at +50°C.DMX Male/Female/Extension cables should be included .The BIS certificate should show factory name as same name of the OEM The Luminaire should be BIS approved and BIS /LM79/LM80 mandatory during tender submission.. Havells XPERIAPRO100WDMX- or equvilent in Signify ColorKinetics ReachElite / Wipro - ARCUS, with 5year on site warranty.
Design, Supply, installation, testing & commissioning of Outdoor of exterior BIS registered RGBW Projector Light luminaire for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness and die casted end caps, of minimum System wattage 30 W. Total System lumens not less than 1500 Lumens. Luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control. Luminaire should be complete with dedicated Lens m offering beam angle of different types such as narrow, medium.. Beam angle 10,25,40 ,18*35 degree.as per site requirement. DMX enabler circuit should be inside the Luminaire only. Operating voltage range 100 -300 V AC. Built-In Potted IP67 electronic LED driver with APFC,lower THD, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10 kV with SPD & other safety test as per IS 15885 Part-2/ Sec 13, IEC60598-1.Operating voltage range 100 -300 V AC. Fixture shall be suitable to operate at an ambient temperature range of -20°C to 50°C and complete luminaire shall be IP66 and IK07 rated. CRI >80. LED Life time shall be at least L70B50 @ 50,000 burning hours at +50°C. DMX Male/Female/Extension cables should be included.The BIS certificate should show factory name as same name of the OEM The Luminaire should be BIS approved and BIS /LM79/LM80 mandatory during tender submission.. Havells XperiaPRO30WDMX- or equvilent in Signify ColorKinetics Uni Flood C Pro Medium ( / Wipro LF04-361-15-CC-G2), with 5year on site warranty.
Design, Supply, installation, testing & commissioning of DMX Controller for the system including all other accessories required for the running of the system Controller should have Input Power 5-5.5V DC 0.6A and Output Protocol DMX512 with 4 universe, 2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universe should be expandable from 2 to 4 DMX512 universes. It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB & Ethernet .Dmx controller should have network controllability feature to control the scene remotely through LAN and triggered via UDP packets on port 2430. Its must have Connections Type C USB, XLR3, Ethernet, battery. There should be provision for Memory microSD card. Device should have Intuitive backlit keyboard with 10 presets and also have provision of kepad on device for changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) & also have Smart Upgrade Technology (SUT). It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C. weight should not be more than 120g. OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/ iPad/Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds of universes with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta; clamp to mount on wall . with data enablers and splitters as required. The Facade Lighting products and DMX controller should be of same / single make. To be provided with IP 66 enclosure if installed in external environment. All accesaries included.( Instruction Forwarder Ranger/Compass(AC). Address writer), DMX Master Controller & IP Boxes) Equivalent Havells DMX , Philips iPlayer 3, Wipro. ARCUS, with 5year on site warranty.
Design, Supply, installation, testing & commissioning of Outdoor of DMX Splitter with Input Voltage range : 190-240V AC, Power Consumption 5W max. Housing is made of CRCA with powder coated finish Mounting, 19 inch rack mountable, Operation Temperature -10°C to +55°C, 8 Output with 3pin XLR terminal sockets, Ingress Protection Rating IP20. This unit takes the DMX Signal from DMX Controller & split the signal into 8 separate output channels. The output terminals of Splitters are optically isolated from the input. Splitters should be capable to amplify the DMX signal & allowing the data link to be extended by max. 300 m (1044 ft.) using AWG 22 DMX cable or 150 m (500 ft.) using AWG 24 DMX cable or maximum 20-25 fixture per output channel. To be provided with IP enclosure if installed in external environment.MaKE:- HAVELLS,Wipro , PHILIPS , with 5year on site warranty.
Design, Supply, installation, testing & commissioning of Signal Amplifier (L11 for Max.30 Light) to boost the Signal, IP 65 rated module to enahce the depleting DMX Signals, should have IP 66/67 rates inbuilt connectors compatible with Luminaires. It should be offered with inbuilt electronic ciruit for functioning. No external LED driver needed.MaKE:- HAVELLS,Wipro , PHILIPS, with 5year on site warranty.
Design, Providing,Testing & Commissioning of Programing and addressing the DMX Controller in the context of unreal engine (UF5) Configuring to Virtual fixtures, creating fully automatic DMX Library & setting up communication between the DMX Engine & Physical Lights. to provide key set up steps:- Enable plugins,configure DMX Ports,DMX Library creation, patching. Core programming workflows:- Creating Scenes/Presets, Virtual Fixtures,Sequence,Timeline, matching,Volumetric Effects. Real worlds integration:- Daisy-Chaining,addressing,interfaces etc as required at site conditions,with 5year on site warranty.
Design, Providing and fixing of Surge Protection Device (SPD) Type 1+2 for protection against direct and indirect lighting surge having maximum discharge current-Imax upto 100 KA along with 3 pole,with Encloser and neutral and shall have all electrical connections,Testing etc. complete as required Make:- L & T, Havells Seimens etc., with 5year on site warranty.
Design, Supply, installation, testing & commissioning of voltage stablizer of 25KVs suitable for UNBALANCED LOAD with auromatic operation (outdoor type- IP-64). The input power shall be at 415- 20% + 10% V, 3 Phase, 4 wire, 50 Hz. The Output voltage shall be 415 V. The stablizer shall comply with the following requirement: Regulation:+/-%" over load & short circuit protection. : Protection cut-off against Over/Under Voltage.: Single phase protection.: 3 nos. phase indication lamps.Make:- servomate (HCS Power Ventures Pvt. Ltd., with 5year on site warranty.
LT Cable & accessories
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.Armoured cable 16 sq. mm (four core) Make:- KEI, Polycab, Havelle's and Grandley.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make:- Havelle's, Finolex,RK Kabel, KEI, Plaza and Polycab.
3 x 2.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Make:- Anchor, AKG, RKG, Diplast and Precision.
EARTHING SYSTEM
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and Installation of DMX Cable 2 Pair :-Conductors: Two tightly twisted pairs with(Data+, Data-, Common). Shielding: Essential; typically a foil shield and a tinned copper braid for EMI protection. Connectors: Usually 5-pin XLR (also 3-pin for legacy/compatibility), but Cat5/6 is also approved.Termination: A 120-ohm resistor across Data+ and Data- pins on the last device in the chain.Signal: Digital (RS-485 based), not analog audio. Capacitance: Low, e.g., <65 pF/m between conductors within shield, <115 pF/m between conductor and shield etc as required at site conditions. make:- Belden, Syntax.
Supplying and laying of folowing size DWC HDPE pipe ISI marked along with all accessories like socked, bend, couplers etc. conforming to IS 14930, Part II complete with fotting curring, jointing etc, direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.Make:- APL,Supreme, Astral and Finolex.
63 mm dia (OD-63 MM & ID-51 mm nominal)
40 mm dia (OD-40 MM & ID-32 mm nominal)
Conditions:-
The work shall be carried out according to CPWD/ HPPWD General Specifications.
The work shall be completed to the entire satisfaction of the Engineer-in-charge.
The firm will have to follow fair wage clause.
Sub-standard work will not be accepted.
No claim on account of fluctuation in prices due to any reason shall be considered.
The quantity can be increased or decreased as per actual requirement at site.
The conditional tenders shall not be accepted.
No premium will be allowed on M.R. Items, abatement, if any shall be applicable on all items including market rates.
The contractor has to employ qualified Engineer for the supervision of work at site.
Any error or omission in nomenclature or unit can be corrected at any stage.
The quality of material shall be strictly in accordance with the specification given in DNIT.
All the material shall be inspected by the Engineer-in-charge of work before installation at site.
The boards & M.S. boxes should be painted with 2 coats of superior quality paint after one coat of primer.
Separate colour of wires shall be used for phase and neutral so as to distinguish it for live conductor.
All the cable/ wire connections should be done through lugs / thimbles duly crimped with proper crimping tools & no extra payment shall be made on this account.
The department has reserve the right to issue any amendment to the work order as emergency demands or allow of altogether cancel the contract without assigning any reason. The department reserves the right to delete / add any item.
Discount offered by the firm should also be considered in deviation of items.
The extra/ substitute items will not be allowed against this work without the prior approval of the competent authority.
Security shall be deducted on each running/ Final bill of the firm as per CPWD/HPPWD works manual.
The firm shall ensure, the availability a licensed electrician/ supervisor/ qualified Engineer during the erection, testing and commissioning.
The contractor will have to produce invoice/ gate pass of the manufacturer for major items of material to be installed against S/E of work for genuine of the material.
The firm shall be quote the rates inclusive all the taxes/ GST whatever required and no extra payment shall be made in this respect.
The fittings/ material should be got inspected by the concerned AE with the representative of the firm and necessary certificate should be signed by the representative of the firm for its genuineness.
Any deviations to the clauses in the tender specifications must be clearly and separately indicated otherwise it shall be presumed that the offer is in line with requirements of tender.
The firm will have to submit three schemes of illumination alongwith 3D walkthrough and will get it approved from competent authority before execution at site.
Note: - All rates taken in the DNIT are inclusive of GST.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.28 MB
Tendernotice_2.pdf
PDF • 0.41 MB
SBD_VidhanSabhaFacadeLight.pdf
Tender Documents • 3.19 MB
BOQ_185254.xls
BOQ • 1.72 MB
DeclarationNEW.pdf
Additional Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .