| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-Finance 1ST SHAKUNTALA SADAN 04 RAMPURA BASTI LALGARH BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹31.1 L+₹3.0 L (10.7%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹35.3 L+₹7.2 L (25.7%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹35.6 L+₹7.5 L (26.6%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹39.2 L+₹11.0 L (39.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹49.1 L
EMD Value
₹98,100
Closing Date
20 Nov 2021, 6:00 pmClosed
GE North Bikaner
GE North Bikaner
REAPAIR REPLACEMENT OF ELECTRIC WIRING AND PANELS IN ZONE B MD ACCN UNDER GE NORTH BIKANER
2021_MES_485206_1
GE (N) BKN TOKEN NO 63/2021-2022
Open Tender
Miscellaneous Works
Item Rate
330 days
BIKANER
Class D category b i
8 documents required · 8 mandatory
₹500
GE North Bikaner
₹98,100
Yes
6 Dec 2021
30 Oct 2021
22 Nov 2021
30 Oct 2021
20 Nov 2021
13 Nov 2021
Amount
Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed.
Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed.
Taking down old U/S existing DB TPN 4 way and DB SPN 8 way including MCB/MCCB of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
Taking down old U/S existing Iron box size 300 X 300 mm and 450 X 900 mm including MCB/MCCB of any capacity and any size and removing from site and filling brick work with plaster making good the disturbed surface of wall etc complete all as specified and as directed.
M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through Existing PVC conduit including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length.
M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through PVC conduit of suitable size including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length.
M & L for submain (single phase) wiring complete with and including 4.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through Existing PVC conduit including accessories and fixed on walls and 4 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 4.0 sqmm PVC insulated wire and one run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit length.
M & L for submain (single phase) wiring complete with and including 4.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through PVC conduit of suitable size including accessories and fixed on walls and 4 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 4.0 sqmm PVC insulated wire and one run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit length.
S&F MCB TPN DB,4 way Vertical type,440V,3 phase with rated busbar 100 Amps, double door type suitable for MCCB as a incomer and MCBs as out going double door type ,grouted in walls with Fixing arrangemant complete all as specified and directed. Make-Legrand cat No-5077 50 or equivalent in C&S,Havells
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 12 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 8 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S & F MCB SPN, 5-32 Amps, 240 volts, breaking capacity 16KA complete all as specified and as dircted by Engr-in-charge.
S & F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
S&F MCCB 63 amps, 4 pole, 415 volts, fixed type breaking capacity 16KA complete all as specified and as directed by Engr-in-charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion.
M & L for point wiring with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 1.5 sqmm 1100 volts grade drawn through and including suitable size of PVC concealed conduit with accessories with laminated top cover fixed on MS sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge for the following :-(a) One Light/fan/ex-fan point controlled by one switch.
(b) one socket point on the same board with other switch complete.
(c) One 3 pin 5 amps socket on independent board.
all as per item No 4 above but with 2.5 sqmm copper wire for 3 pin socket outlet 15 Amp on independent board complete and all as directed by Engr-in-charge.
all as per item No 4 above but but one light point controlled by two 02 way switch board complete and all as directed by Engr-in-charge.
S&F switch piano type, 5 Amp, single pole one way, 230 Volts, flush type complete all as specified and as directed by Engr- in -charge.
M&L Switch piano flush type single pole, one way 15 Amps 230 Volts complete all as specified & directed by Engr-in-Charge.
S&F switch piano type, 5 Amp, single pole two way, 230 Volts, flush type complete all as specified and as directed by Engr- in -charge.
M&L socket outlet 3Pin, 5 Amps flush type 230 Volts complete all as specified and directed by Engr-in-Charge.
M&L for socket outlet 2 in 1, 3 Pin, 5 & 15 Amps, 230 Volts t complete all as specified & directed by Engr-in-Charge.
M&L singal pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 Amp complete all as specified & directed by Engr-in-Charge.
S&F ceiling rose, surface backelite , three terminal AC, 230 volt complete all as specified.
supply and fixing fan regulator electronic socket type five step controlled 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.
supply and fixing Bell push, flush type, 5 amp 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.
supply and fixing Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed by Engr-In-Charge.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings
Taking dowen and refixing LED tube light fitting, 1x 20-22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge.
Taking dowen and refixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Taking down fan,sealing cable end,dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep , keeping side in store in safe custody for painting of ceiling fan complete,in situ with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust and reassembling the fan complete including writing MES No at the site.
Taking down Exhaust fan,sealing cable end,dismantling blades and removing fan and blades & refixing Exhaust fan of any make, any sweep , keeping side in store in safe custody for painting of Exhaust fan complete,in situ with synthetic enamel paint byspraying including filling cavities with filler,one coat after cleaning all dust and reassembling the fan complete including writing MES No at the site.
Removing and refixing water heater storage type, puff insulation type of 25 ltrs capactiy and 1500 watts, BEE Star rated-5, with glass line inner shell with Hot & Cold pipe, water connection pipe, electric connection and necessary fixing arrangement complete all as specified and directed.
Repair to existing panel board indoor type sheet metal approximate size (5X5X1.5 Feet) parts tinkering the parts and replacing fully corroded sheet metal parts like base plate,topplate,front cover etc with appropriate gauges MS Sheet including bending to match with the existing size, welding brazing and assembling including replacing all nuts & bolt in MCBs and proper legging in cable and control wire sheet metal screws and replacing of unservicale volt meter,amp meter and CT ,PT and painting complete body with two coats of synthetic enamel paint over a coat of zink chrome primer and marking the Qtr No, panel board no in front side and complete all as specified and as directed by engineer in charge and tested on completion.
S&F MCCB 100 amps, 4 pole, 415 volts, fixed type breaking capacity 16KA complete all as specified and as directed by Engr-in-charge.
S&F MCCB 40 amps, 4 pole, 415 volts, fixed type breaking capacity 16KA complete all as specified and as directed by Engr-in-charge.
durga construction company
ALPHA ENGINEERING COMPANY
B.K. ROY & SONS
GS BUILDERS AND ENGINEERS
A.S. CONSTRUCTION COMPANY
JASNATH ENTERPRISES
M/S BIKANER CHEMICAL LABORATORIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .