Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.9 Cr
EMD Value
₹3.9 L
Closing Date
19 Nov 2026, 5:00 pm7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
PIC, UED, BHU
office of PIC, UED, BHU, Varanasi
Underground cabling work in place of overhead electric line including street lights, BHU.
2026_BHU_933578_1
EWSS/UED/2026/06112026-1
Open Tender
Electrical Works
Works
90 days
BHU
As per tender document
10 documents required · 10 mandatory
₹500
Registrar, BHU
₹3.9 L
6 Nov 2026
6 Nov 2026
24 Nov 2026
6 Nov 2026
19 Nov 2026
6 Nov 2026
6 Nov 2026 - 13 Nov 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, of following size UG cable size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as per CPWD specification .(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx185 Sq. mm | 954 | Mtrs | 2,814 | ₹26,84,556 |
| 2 | Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, of following size UG cable size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as per CPWD specification .(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx95 Sq. mm | 550 | Mtrs | 1,709 | ₹9,39,950 |
| 3 | Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, of following size UG cable size direct in ground as an additional run including excavation, sand cushioning, protective covering and refilling the trench etc as per CPWD specification..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx185 Sq. mm | 879 | Mtrs | 2,688 | ₹23,62,752 |
| 4 | Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, of following size UG cable size direct in ground as an additional run including excavation, sand cushioning, protective covering and refilling the trench etc as per CPWD specification..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx95 Sq. mm | 535 | Mtrs | 1,582 | ₹8,46,370 |
| 5 | Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing masonry open duct as required..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx185 Sq. mm | 510 | Mtrs | 2,432 | ₹12,40,320 |
| 6 | Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing masonry open duct as required..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx120 Sq. mm | 62 | Mtrs | 1,670 | ₹1,03,540 |
| 7 | Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing masonry open duct as required..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx95 Sq. mm ) | 170 | Mtrs | 1,327 | ₹2,25,590 |
| 8 | Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing masonry open duct as required..(Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 4Cx10 Sq. mm | 338 | Mtrs | 390 | ₹1,31,820 |
| 9 | Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing RCC/Hume/Metal/DWC HDPE pipe as per CPWD specification. (Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 3.5Cx25 Sq. mm | 615 | Mtrs | 427 | ₹2,62,605 |
| 10 | Supplying and laying of one number 1.1 kV grade, XLPE insulated, PVC inner sheathed, Galvanized Steel Strip (G.S. Strip) armoured, PVC outer sheathed, Aluminium conductor underground power cable conforming to IS 7098 (Part-1): 1988 (latest amendment), with stranded, compacted aluminium conductor, suitable for 1100 Volts working voltage of following size in the existing RCC/Hume/Metal/DWC HDPE pipe as per CPWD specification. (Make-Polycab/Universal/Gloster/KEI/Havells/Finolex) 4Cx10 Sq. mm | 4,465 | Mtrs | 399 | ₹17,81,535 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
TD.pdf
Tender Documents • 2.16 MB
BOQ_981059.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .