Tender Value
₹75 L
EMD Value
₹1.4 L
Closing Date
14 Oct 2024, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD
SPECIAL REPAIRS TO ROOF TREATMENT AND SUNKEN FLOOR AT SADANAND BLOCK AT AFA HYDERABAD
2024_MES_673296_1
86764/E8
Open Tender
Civil Works
Item Rate
180 days
GE AFA HYDERABAD
As per NIT
9 documents required · 9 mandatory
₹1,000
GE AFA HYDERABAD
₹1.4 L
Yes
11 Nov 2024
9 Sept 2024
16 Oct 2024
9 Sept 2024
14 Oct 2024
30 Sept 2024
9 Sept 2024 - 26 Sept 2024
Amount
SCHEDULE 'A' PART - I (B/R PORTION) :- Demolition of cement concrete or surkhi filling of any description and in any position not otherwise specifically provided for Roof treatment treatment etc complete all as specified and as directed.
M&L Cement concrete type B-1 1:2:4 (20mm graded aggregate) in roof padding concerte of average 50 mm thick with liquid water proofing compound as per manufacturers instructions etc complete all as specified and as directed. Note: WPC will be measured & paid separately under relevant Item
M & L Cement concrete type B-0 1:2:4 (12.5mm grades aggregate) in haunching concrete etc complete all as specified and as directed.
M&L for Rendering 10mm thick in cm 1 : 3 mixed with liquid water proofing compound as per manufacturers instructions on concrete surfaces when PCC on roof surface is still green including finished even and fair etc complete all as directed. Note: WPC will be measured & paid separately under relevant Item
(i) Removing existing water proofing treatment of any description, any type on roofs, picking, sweeping, cleaning and washing down with water to remove all loose particles, dust etc complete all as specified and as directed. (ii) While doing the treatment on existing roof, concrete should be thoroughly inspected for any significant distress,if any shall be repaired. rehabilitated and treated. Pipes over roof shall be realigned where ever required. (iii) Cleaning the surface of roof & up to 300 mm of parapets and crumple joint including junction of roof and parapet, providing and laying fixing TPO (Thermoplastic Polyolefin) water proofing membrane STP LIMITED SHALI TPO (Minimum 1.2 mm thick) Over a min 200 GSM Geo textile or Asian Paints TPO or equivalent product of M/s MC Bauchemic / CIPY/ SIKA / Pidilite or Dr Fixit TPO membrane, applied as per manufacturer's instructions. (iv) The work shall be carried out complete as per application and manufacturer's specifications authorised methodology. Execution to be done with trained/ skilled applicator of manufacturer as per the technical guidelines laid by manufacturer, Company guarantees to be given by contractor after completion of water proofing work before payment.
Removal of debris (Aggregates) obatained from demolition including loading and unloading to a distance of 5km from the starting point and deposited where directed etc complete all as specified and as directed.
Providing and carry out expansion joint treatment after proper surface preparation to remove loose mortars, dust, foreign particles from joints, fixing of tightly packed closed cell polyethylene based back up rod or filler board to ensure no gaps or voids exists, mask face edge of the joint using masking tape for neat finish, application of polyurethane or polysulphide sealant (width to depth : 2:1 ratio) and allow it cure for 2 days. Mixing of Two part Epoxy Adhesive using slow speed drill till get homogeneous mix, apply it to prepared joint 1-2mm thick with notched trowel or putty blade, tooled to a smooth finish and finally fixing of Flexible expansion joint (FPO Tape) membrane Dr. Fixit Seal Tape/ Hydrogapshield available in 1mm thickness and 150 mm wide exhibiting superior mechanical properties like, Elongation >500%, Tensile Strength >12N/mm2, Tear Strength >200N above joint followed by another layer of epoxy adhesives as complete as per manufacturer’s specification. Epoxy adhesive shall be applied on outer edges of tape. For joint over end laps, the overlaps surfaces must be clean, wiped and lapped with 100 mm overlap. After application the system should be allowed to cure for 7 days complete all as specified and as directed.
M&L for Removing of plants including roots by dismantling of brick work/PCC/RCC including necessary scaffolding , any type , any location/height( roof, parapet walls near pipes etc) and spraying the affected area with solution of 25ml Glyphosphate (4% content) diluted with 1 litre of water or as per manufacturer's instructions after removing roots from wall slabs for preventing the regrowing and making good the disturbed portion using PCC 1:2:4 type B-0 with 12.5mm graded aggregate and plaster in CM 1:3 (Size of the disturbed portion 150X150X150mm) etc complete all as specified and as directed.
Cutting out V groove on cracks of walls and cleaning out, wetting, grouting with crack filler (Dr Fixit or equivalent) mixing with cement slurry, making good the surface by using CM 1:3 or PCC 1:2:4 type B-0 as required at site, as per manufactures instuctions, of any description and in any position, with necessary scaffoldings complete all as specified and as directed.
M&L 100 mm thick Cement concrete type B- 2,1:2:4 (40mm graded aggregate) etc complete all as specified and as directed
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) average 40 mm thick with water proofing compond finished in sunken floor portion etc complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1 : 3 on fair faces of brick or concrete surfaces mixed with water proofing compound finished even and smooth in sunken portion without using extra cement etc complete as specified and as directed.
M & L for water proofing treatment to sunken slabs as under complete all as specified and as directed:- (i) Preparation and cleaning of the existing sunken/owered portion of RCC slab surface for full depth of sunken floor by wire brush. chisel out any mortar sticking the surface. (ii) Applying STP LIMITED SHALIURETHANE BTD-BLACK (Minimum 0.80mm dft) over a priming coat of SHALIURETHANE BTD-BLACK 1:1 RÄTIO primer or equivalent product ofAsian paints /M/s MC Bauchemie/ CIPY/SIKA I Pidilite Dr Fixit Thermax / STP applied as per manufacturers instructions to bottom and full vertical sides of sunken floors (iii) Fill it with water and check for dampness and seepage. Incase the slightest indication of seepage / leekage is noticed, the same shall be rectified by injection grouting to seal all cracks or application of polymer modified mortar STP LIMITED SHALI SBR-LATEX or equivalent of M/s MC Bauchemie/CIPY SIKA / Pidilite Dr Fixit / Asian paints / Thermax / STP admixed with integral WPG or cementitous crystalline waterproofirg compound in the affected area to seal all cracks and mícro cracks if any, and this shall be done by contractor at his own cost. (iv) Apply additional coat of STP LIMITED SHALIURETHANE BTD-BLACK or equivalent of Asian paints / M/s MC Bauchemie / CIPYI SIKA/ Pidilite Dr Fixit / Thermax / STP (v) All junction points of side walls where CI/GI pipes are passing through shall be sealed with epoxy cement mortar.
M&L for PCC (1:5:10) type E2 using 40mm graded stone aggregate filling and mass concrete complete all as specified and as directed.
M&Lfor laying PCC (1:2:4) type B-2 using 40 mm graded aggregate in floors/sub base of 75 mm average thick for etc finished fair and even etc complete all as specified and as directed.
Dismantling floor, heath or wall tiling including cement sand mortar bedding and removing rubbish of the premises complete all as specified and as directed.
S&F of Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc including Screed bed or bedding in layer of mortar 15 mm thick for laying floor finishes in cement plaster 1:4, complete all as specified and as directed.
M&L for glazed ceramic tiles coloured of size 350 x 250 x 7 mm / 450 X 350 X 7 mm thick as on walls over jointing in neet slurry and pointing in coloured cement to match the inside of tiles including 10mm thick rendering in cement mortar (1:4) complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or thickness as on platform, shelves, floors etc laid, bedded and pointed in any mortar complete all as specified and as directed.
M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over 20 mm thick screed bed or bedding layer in cement mortar (1:6), including pointingin white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided fo complete all as specified and directed.
M&L for pre-cast reinforced cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), set in cement mortar 1:4 as in kitchen flat form and shelves in kitchen slabs, landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, with plain faces etc complete all as specified and as directed.
M&L for MS TMT bars 10 mm dia and over cut to length bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90 mm dia complete all as specified and as directed.
Taking up or down 15mm bore of pipe PVC/steel tubing and connections, including for refixing or removal etc complete all as specified and directed.
Taking up or down 20mm bore of pipe PVC/steel tubing and connections, including for refixing or removal etc complete all as specified and directed.
Taking up or down 25mm bore of pipe PVC/steel tubing and connections, including for refixing or removal etc complete all as specified and directed.
Taking up or down GI tubing of 40/50 mm bore and connectons etc complete all as specified and as directed.
S&F of 15 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed.
S&F of 20 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed.
S&F of 25 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed.
S & F GI tubes of 40 mm dia medium grade with all fittings and fixed complete to walls & ceiling or laid in floors etc complete all as specified and as directed.
S&F in repairs of High density polyethylene pipes (HDPE) 40mm dia of pressure rating 6kg/cm2 fixed complete to walls or laid in floors complete all as specified and as directed.
S&F in repairs of Vitreous China wash down water closet pan (Pedestal pattern), white including connection to drain and to flushing pipe, and plastic water closet seat, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device etc complete all as specified and as directed.
S&F in repairs of Vitreous china wash basin, oval type white flat back, of any size excluding taps, waste, chain and plug and porcelain stopper but including brackets etc complete all as specified and as directed.
Supply only of Waste coupling of 32 mm chromium plated for glazed ware basins with long screwed shanks and fly-nuts etc complete all as specified and as directed.
S&F in repairs of CP Bib fancy type taps 15mm bore cast copper alloy with capstan head fancy type screwed down screwed for iron pipe or for brass ferrule etc complete all as specified and as directed.
S&F in repairs of Angle cock of 15 mm dia cast copper alloy with capstan head fancy type chromium plated etc complete all as specified and as directed.
S&F in repairs of Gun metal globe or gate valves/Non returning Valve of 25mm dia with iron wheel head screwed both ends for iron pipe etc complete all as specified and as directed.
S&F in repairs of Ball valve 40mm dia high pressure PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum wt. 210gms) etc complete all as specified and as directed.
S&F in repairs of PVC valveless, syphonic action type, flushing cistern, low level, 10 ltr capacity, white, with inlet, ball valve, float and handle including brackets and long flush band etc complete all as specified and as directed.
S&F in repairs of PVC connection 15mm size with brass CP nuts of length 600 mm complete all as specified and as directed.
S&F in repairs of brass chromium plated towel rack 600mm long "D" type fixed with suitable steel screw etc complete all as specified and as directed.
S&F in repairs Soap dish, stainless steel and fixed to wall complete all as specified and as directed.
S&F in repairs toilet paper holder ABS body chromium plated box type complete all as specified and as directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed.
S&Fin repairs of CP Bib taps two way in one 15 mm cast copper alloy fancy type with capstan head screwed down screwed for iron pipe or for brass ferrule etc complete all as specified and as directed. Make : Jaguar or equivalent
S&F in repairs of ABS body CP health faucet complete set including holder stand and one metre PVC pipe, 15 mm cast copper alloy screwed down screwed for iron pipe or for brass ferrule etc complete all as specified and as directed. Make : CERA Cat Part No 8030101.
S&F in repairs glass corner/ mirror shelves size 300/450 mm of each fixed with necessary screws, bolts , and supporting L type angles with drilling in walls complete all as specified and as directed.
S&F in repairs of stainless steel grating 100 mm dia without hole complete all as specified and as directed.
S&F in repairs of stainless steel grating 100 mm dia with hole complete all as specified and as directed.
S&F in repairs PVC Cabinet of size 600mm x450mm with necessary fittings and hinges complete all as specified and as directed.
S&F in repairs of Brass CP wall mixer 'hot' & cold water scrwed down for iron pipe etc complete all as specified and as directed. Make: Jaquar or equivalent make as approved by GE.
S&F in repair of centre hole basin mixture 15 mm bore dia with fancy type heads chromium plated screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and capston head, screwed for iron pipe and fixed complete all as specified and as directed. Cat Part No COT-23169B Make :Jaquar or equivalent make as approved by GE.
S&F in repairs of PVC waste pipe 32 mm bore, 900 mm long etc complete all as specified and as directed.
S&F in repairs of towel ring 150 mm dia type ABS body chromium plated fixed with and including Chromium plated brass screws complete all as specified and as directed.
S & F in repairs of Rotational moulded PVC water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and fixed in position all as specified in SSR part – I including dismantling of OHT of capacity 1000 ltrs complete all as specified and as directed.
M&L Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc exc 500 and n exc 1000 capacity in litres and write date of cleaning and due date of cleaning on OHT complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and as directed.
S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed on walls complete all as specified and as directed.
S&F PVC (SWR) bends any radius suitable for 110mm bore pipecomplete all as specified and as directed.
S&F PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed on walls complete all as specified and as directed.
S&F PVC (SWR) bends any radius suitable for 75mm bore pipe complete all as specified and as directed.
S&F in repairs PVC (SWR) branch piece single (Single Y) with access door equal or unequal 110 mm dia all as specified and as directed.
S&F in repairs PVC (SWR) branch piece single (Single Y) with access door equal or unequal 75 mm dia all as specified and as directed.
S&F in repairs PVC (SWR) Vent cowel for 75mm bore specified and as directed.
S&F in repairs PVC (SWR) Vent cowel for 110mm bore specified and directed
S&F stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm dia bore of pipe complete all as specified and as directed.
S&F stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm dia bore of pipe complete all as specified and as directed.
S&F in repairs of cast iron Nahani trap 75 mm dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) etc complete all as specified and as directed.
M & L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed.
Taking down plaster in wall/ceilling surfaces on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr -in- charge.
Demolition of Brickwork or stone / boulder / PCC block masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stone-work and precast concrete articles etc complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry of type C1 1:3:6 (using 20mm graded stone aggregate) with solid blocks exc 10cm in width and setting in cement mortar 1:6 etc complete all as specified and as directed.
M&L for half brickwork with sub class 'B' old size bricks, straight or curved on plan, to any radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for plastering in internal wall surfaces of 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for plastering in external wall surfaces of 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for rendering 10 mm thick in CM 1:4 on concrete surfaces as ceilling finished even and smooth (without using extra cement) complete all as specified and as directed.
Supply only Liquid water proofing compound complete all as specified and as directed.
M & L for two coats of oil bound distemper on newly plastered surface of walls over a coat of alkali resistant primer including preparation of surfaces complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats white wash etc. complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of external walls and applying two coats cement base paint over a coat of cement primer complete all as specified and as directed.
Taking down Chowkhats or frames with shutters (wihout taking off shutters) from the frame exc 1.5 sq. m but n exc 4 sq. m complete all as specified and as directed.
Taking down Chowkhats or frames with shutters (wihout taking off shutters) from the frame n.exc 1.5 sq. m complete all as specified and as directed.
S&F factory made solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specifed and as directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement etc complete all as specified and as directed.
S&F for aluminium anodized barrel tower bolts 200 mm of extruded section and fixed complete all as specified and as directed.
S&F 150 mm size aluminium alloy handles, febricated type extruded section, ISI marked complete all as specified and as directed.
S&F of butt hinges, medium weight, cold rolled mild steel of 100 mm long complete all as specified and as directed.
Cutting holes in brick work built in cement mortar for inserting hold fast and making good dismantled portion in CM 1:3 depth of cutting exc half brick but n. exc one brick complete all as specified and as directed.
M & L for MS flat for hold fast. Conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F aluminium anodised various section powder coated as required for window/ ventilators etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement for shutter, sealant etc all as specified and as directed by Engr- in- charge. Note:-Aluminium window/ ventilators to be fixed with cadmium plated screw not less then 300 mm C to C & cealing the joints between frames & granite stone with polysulphide sealant as per the manufactures instruction" complete all as specified and as directed.
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for type of shutters(hung/sliding) of doors, windows, ventilators, including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections / appropriate Z sections and other sections of aproved make conforming to IS- 733 and IS- 1285, with dash fasteners of required dia and size, including neccessary filling up the gaps at junctions, i.e. at top, bottom ad sides with required EPDM rubber / neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, CP brass / stainless steel screws, all complete as per architctural drawigs and the directions complete all as specified and as directed.
S&F Powder coated (Thickness not less than 50micron) Aluminium anodised Grill, aperture n exc 75 mm ,size 6mm x 4mm thick, including 1 mm thick channel fixed with steel screws complete all as specified and as directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Dismantling boarding of any description, fixed in any position fixed with nails complete all as specified and as directed.
M&L block boards 18/19mm thick, grade 2 quality, interior grade, fixed with screws to timber rame work complete all as specified and as directed.
M&L for 0.9 mm thick Decorative laminated sheet type 1 of surface finish coloured and pattern as approved and fixed over plywood with approved adhesive complete all as specified and as directed.
M&L for 19mm wide. external teak wood lipping, 6mm thick, fixed with nails complete all as specified and as directed.
M&L in repair 2nd class hardwood Plain fillets (50x50) Exc 13 & n.exc 25 Sq.cm, square, rectangular or triangular in section, clean sawn, secured with screws or nails or brads complete all as specified and as directed.
S/F of 40 mm dia. cup boards knobs fixed with nut , screw and washer of mild steel, bright finished complete all as specified and as directed.
S/F of Stainless steel butt hinges 75 mm long wih screw complete all as specified and as directed.
S&F standard quality magnetic catcher for cupboard shutters complete all as specified and as directed.
SCHEDULE 'A' PART - II (E/M PORTION) :- Taking down carefully un serviceable point wiring of light points, fan, socket out let on TW battens/PVC pipes/casing & caping including material like sockets, switches, ceiling roses, regulators, light fittings etc and removing the materials from site and making good the disturbed portion of walls/floors ceiling etc complete all as specified and as directed.
Taking down Exhaust Fan dismantling blades and removing fan and refixing Exhaust fan after completion of re-wiring and connecting up by cleaning / oiling etc including provision of 3 core flexible cable from ceiling rose or connector to fan complete all as specified and as directed.
Taking Down 25 litre capacity geyser from position after disconnecting the inlet and out let connections and rusted nuts bolts, screws washers, gaskets, fusible plug, etc and fixing back geyser with new PVC heavy duty hot/cold connections etc complete all as specified and as directed.
M & L for Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLS with earth continuity conductor of 1.5 sqmm PVC insulated copper conductor and including rigid PVC conduit concealed of suitable size but not less than 20mm dia. and all accessories fixed to be consealed in wall & surface of the roof etc., including modular type terminal boxes made out of Galvanised sheet of thickness should be not lessthan 0.9mm thick for fixing of modular switches, modular fan regulators, modular socket outlet etc along-with suitable modular plate for housing switches, etc complete all as specified and as directed.
One light point controlled by one switch
One Fan point controlled by one switch
One three pin socket 5 Amps plug point independent
All as per Ser item No 3 above but with 2.5 sqmm copper cable in and including PVC conduit complete all as specified and as directed for 15A socket (For Geyser) .
S&F of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
S&F of Modular Switch type polycorbonate white 1 way, 6A, 240Volts complete all as specified and as directed.
S&F of Modular Socket outlet polycorbonate white 10A - 2/3 pin complete all as specified and as directed.
S&F of Modular Switch type polycorbonate white 1 way, 16A, 240Volts complete all as specified and as directed.
S&F of Modular Socket outlet polycorbonate white 20A - 2/3 pin complete all as specified and as directed.
S&F LED light fitting 1x20w 220V,AC decorative box type with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet 1x10w 220V,AC decorative box type with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
GUTHIKONDA BROTHERS (BID ID -3130928)
Vipin Kumar and Brother (BID ID -3131020)
Saiansh Associates (BID ID -3134497)
VACON INFRASTRUCTURES (BID ID -3131323)
S J REDDY (BID ID -3131219)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .