Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC | ₹6.2 L | L1 | Accepted-AOC LESS |
| 2 | L2₹6.3 L+₹4,400 (0.71%)Rejected-AOC | ₹6.3 L+₹4,400 (0.71%) | L2 | Rejected-AOC ABOVE |
| Sl No | Description | Qty | Unit | S.Sudhagar L1 | S.Manimegalai L2 |
|---|---|---|---|---|---|
| 1.00Supply and delivery of submersible centrifugal sewage non-clog pumps, vertical spindle type pump , wear resistancewith submersible motor for the various duty conditions. Pump shall be capable of handling min 100 mm solid size withsewage specific gravity of up to 1.05. Pump shall be of robust construction, Liquid passages shall be finished smoothand designed as to allow free passage to solids. Pump Impeller should be of Non-clog semi open type , single vane /multi vane preferably contra bloc or vortex impeller design. Double mechanical seal with silicon carbide faces should beprovided to protect the motor from ingress of sewage along the shaft. The critical speed of the rotor shall be at least30% above the operating speed. Pumps should have double bearings between the pump & motor. The bearings lifeshall be minimum 100,000 hrs of operation with greased for life. Pump should be provided with automatic couplingdevice including pedestal, duck foot bend, stainless steel guide pipe or related accessories of suitable size to facilitatelifting and lowering into guide rails for easy maintenance. Pump shall be provided with a stainless steel lifting chainconforming to BS 970 Gr 304. Pump speed shall be of 9600 rpm for high duty pumps and 960/1450 rpm for low dutypumpsets. Casing and impeller should be of CI Gr. FG 260 :IS210 more preferably with hardened impeller.Shaft shouldbe of stainless steel AISI 410. All the fasteners and bolts shall be of AISI 410.The submersible motor shall be operatedwith 3ph, 415 V(+or– 10%), 50Hz(+or-5 %) dry induction type. Motor shall be capable of giving rated output withoutreduction in the expected life span when operated continuously. The rotating assembly shall be dynamically balancedas per standards. The starting current of the motor shall not exceed 200% of rated full load current for Star / Delta orATS starting under any circumstances .The motor shall be suitable for full voltage star delta / ATS starting. The lockedrotor current of the motor shall not exceed 600% of full load current unless otherwise specified. Motor shall bedesigned to withstand 120% of rated speed for two minutes without any mechanical damage, in either direction ofrotation. The motor vibration shall be within the limit specified in applicable standards . Motor should be of IE2,explosion proof compatible for VFD operation together with star-Delta /ATS starter, protection against increase instator winding temperature (15 deg Celsius), bearing temperature, leakage in the stator housing and terminalbox shallbe provided and to be suitably interlocked with the control panel for tripping the pump in case of increase intemperature beyond set limit.Insulation class shall be of “Class H” and degree of protection shall be of IP 68 as per IS 4691. Motor shall be suitable for continuous operation in fully submerged or partially submerged condition.The pumpset shall be supplied with powercable of PVC insulated and PVC sheathed, copper, flexible, round type with required conductor size and number ofcores as per starting method and of specified length for continuous use under water and air. The control cable of PVCinsulated, PVC sheathed, flexible for stator winding temperature sensor 3core x 1.5 sq.mm copper conductor and for bimetallic switches 2core x 1.5 sqmm copper conductor shall be provided. Motor shall be supplied with 10m of round submersible copper cable of suitable size. The non clog submersible pumpset shall be provided with suitable starter control panel having all protections as mentioned above. (upto 5 HP - DOL Starter, above 5 HP to 25 HP -Star Delta Panel and beyond 25 HP shall be ATS) | |||||
| 1.01 | Discharge Upto 20 M3/hour | 1 | NOS | 5,94,700 ₹5,94,700 Lowest | 5,99,000 ₹5,99,000 |
| 2.00 | Supply of Floats for 7.5 HP Sullage motor 2x1.5sq.mm cable from panel board to floatin feet collection well etc,complete as per deptmental officers. | 1 | NOS | 10,900 ₹10,900 Lowest | 11,000 ₹11,000 |
| 3.00 | Supply of nylon double barided heavy duty HDPE hose with suitable clamp etc., complete | 8 | M | 1,670 ₹13,360 Lowest | 1,670 ₹13,360 Lowest |
| 4.00 | Supply and fixing of 150mm GI Flange setwith suitable clamp etc., complete | 1 | NOS | 5,000 ₹5,000 Lowest | 5,000 ₹5,000 Lowest |
| 5.00Add :- GST @ 18% | |||||
Tender Value
₹8 L
EMD Value
₹8,000
Closing Date
19 Dec 2025, 3:00 pmClosed
Assistant Commissioner
Coimbatore Corporation, Central zone, Hosur road, Coimbatore.641018
Supply and delivery of submersible centrifugal sewage pumps at Green Park in ward no 62
2025_MAWS_631177_18
E6/2025-26/CZ
Open Tender
Civil Works
Works
Central zone
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹8,000
Yes
11 Aug 2026
12 Dec 2025
19 Dec 2025
12 Dec 2025
19 Dec 2025
12 Dec 2025
Supply and delivery of submersible centrifugal sewage non-clog pumps, vertical spindle type pump , wear resistancewith submersible motor for the various duty conditions. Pump shall be capable of handling min 100 mm solid size withsewage specific gravity of up to 1.05. Pump shall be of robust construction, Liquid passages shall be finished smoothand designed as to allow free passage to solids. Pump Impeller should be of Non-clog semi open type , single vane /multi vane preferably contra bloc or vortex impeller design. Double mechanical seal with silicon carbide faces should beprovided to protect the motor from ingress of sewage along the shaft. The critical speed of the rotor shall be at least30% above the operating speed. Pumps should have double bearings between the pump & motor. The bearings lifeshall be minimum 100,000 hrs of operation with greased for life. Pump should be provided with automatic couplingdevice including pedestal, duck foot bend, stainless steel guide pipe or related accessories of suitable size to facilitatelifting and lowering into guide rails for easy maintenance. Pump shall be provided with a stainless steel lifting chainconforming to BS 970 Gr 304. Pump speed shall be of 9600 rpm for high duty pumps and 960/1450 rpm for low dutypumpsets. Casing and impeller should be of CI Gr. FG 260 :IS210 more preferably with hardened impeller.Shaft shouldbe of stainless steel AISI 410. All the fasteners and bolts shall be of AISI 410.The submersible motor shall be operatedwith 3ph, 415 V(+or– 10%), 50Hz(+or-5 %) dry induction type. Motor shall be capable of giving rated output withoutreduction in the expected life span when operated continuously. The rotating assembly shall be dynamically balancedas per standards. The starting current of the motor shall not exceed 200% of rated full load current for Star / Delta orATS starting under any circumstances .The motor shall be suitable for full voltage star delta / ATS starting. The lockedrotor current of the motor shall not exceed 600% of full load current unless otherwise specified. Motor shall bedesigned to withstand 120% of rated speed for two minutes without any mechanical damage, in either direction ofrotation. The motor vibration shall be within the limit specified in applicable standards . Motor should be of IE2,explosion proof compatible for VFD operation together with star-Delta /ATS starter, protection against increase instator winding temperature (15 deg Celsius), bearing temperature, leakage in the stator housing and terminalbox shallbe provided and to be suitably interlocked with the control panel for tripping the pump in case of increase intemperature beyond set limit.Insulation class shall be of “Class H” and degree of protection shall be of IP 68 as per IS 4691. Motor shall be suitable for continuous operation in fully submerged or partially submerged condition.The pumpset shall be supplied with powercable of PVC insulated and PVC sheathed, copper, flexible, round type with required conductor size and number ofcores as per starting method and of specified length for continuous use under water and air. The control cable of PVCinsulated, PVC sheathed, flexible for stator winding temperature sensor 3core x 1.5 sq.mm copper conductor and for bimetallic switches 2core x 1.5 sqmm copper conductor shall be provided. Motor shall be supplied with 10m of round submersible copper cable of suitable size. The non clog submersible pumpset shall be provided with suitable starter control panel having all protections as mentioned above. (upto 5 HP - DOL Starter, above 5 HP to 25 HP -Star Delta Panel and beyond 25 HP shall be ATS)
Discharge Upto 20 M3/hour
Supply of Floats for 7.5 HP Sullage motor 2x1.5sq.mm cable from panel board to floatin feet collection well etc,complete as per deptmental officers.
Supply of nylon double barided heavy duty HDPE hose with suitable clamp etc., complete
Supply and fixing of 150mm GI Flange setwith suitable clamp etc., complete
Add :- GST @ 18%
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_755150.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .