| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 CrAccepted-AOC | ₹1.2 Cr | 1 | Accepted-AOC Being lowest |
| 2 | 2₹1.2 CrRejected-Finance | ₹1.2 Cr | 2 | Rejected-Finance not being lowest |
| 3 | 3₹1.3 CrRejected-Finance RAILWAY ROAD 9 10 KC MARKET 132001 2021R66 | KARNAL | HARYANA | 132001 | ₹1.3 Cr | 3 | Rejected-Finance not being lowest |
| 4 | 4₹1.5 CrRejected-Finance | ₹1.5 Cr | 4 | Rejected-Finance not being lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical disqualified |
| Sl No | Description | Qty | Unit | POMERA AND CO LTD L3 | akshay premium solar L1 | ARYA ELECTRIC COMPANY L2 | S M ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | [32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-
(a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.
(b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC
(c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency
(d) Data Monitoring System complete with accessories.
(e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.
(f) Lightning and surge voltage protection.
(g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp [Through Rate] AS MENTIONED IN DNIT | 390 | KWp | 1,30,26,000 ₹1.3 Cr | 1,18,87,590 ₹1.2 Cr | 1,18,91,100 ₹1.2 Cr | 1,45,00,200 ₹1.5 Cr |
Tender Value
₹1.7 Cr
EMD Value
₹3.3 L
Closing Date
19 Jan 2026, 5:00 pmClosed
Sh Pankaj Sharma
Kurukshetra University
Supply Erection Testing and commissioning of grid connected roof top solar power plant.
2026_HRY_496183_1
20261B5E5C1D F8B8 4E32 A762 3D42821BBCC01139KUK
Open Tender
Solar Power Plants
360 days
Kurukshetra (Thanesar)
Supply Erection Testing and commissioning of grid connected roof top solar power plant.
2 documents required · 2 mandatory
₹17,700
₹3.3 L
Yes
18 Jun 2026
10 Jan 2026
20 Jan 2026
10 Jan 2026
19 Jan 2026
10 Jan 2026
[32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp [Through Rate] AS MENTIONED IN DNIT
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.01 MB
BOQ_574693.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid