| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.9 LAccepted-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIRPORT ROAD JAMMU 181101 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181101 | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹27.4 L+₹16,100 (0.59%)Rejected-AOC | L-2 | Rejected-AOC Not being the lowest bidder | |
| 3 | L-3₹28.6 L+₹1.4 L (5.12%)Rejected-AOC | L-3 | Rejected-AOC Not being the lowest bidder | |
| 4 | L-4₹29.0 L+₹1.7 L (6.40%)Rejected-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-4 | Rejected-AOC Not being the lowest bidder | |
| 5 | L-5₹29.5 L+₹2.3 L (8.41%)Rejected-AOC | L-5 | Rejected-AOC Not being the lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
8 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
REPAIR TO ROOF TREATMENT SUNKEN FLOOR PVC WATER TANKS RAIN WATER PIPE FACIA BALCONIES PLASTERING AND PLINTH PROTECTION AT BD BARI MIL STN UNDER GE KALUCHAK
2020_MES_359957_1
GE/KC/NIT-28/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹60,000
Yes
4 Sept 2020
10 Jul 2020
11 Aug 2020
10 Jul 2020
8 Aug 2020
25 Jul 2020
10 Jul 2020 - 24 Jul 2020
60 days
Amount
B/R Portion
Demolition of brick work masonry built in cement mortar including all quoins, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and as directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in in CM 1:6, complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete, but except brick, i.e. using serviceable bricks obtained from demolition, complete all as specified and as directed.
Mild steel framed works such as in grills, gratings, framed guard bars, etc. and similar work conforming to Fe-410-O or Fe-310-O grade, including bending, cutting and necesary welding required with fabrication and welding as required, complete all as specified and as directed.
Mild Steel Fastening and securing ends of hand rail, balusters, newels, rag bolts, etc., let into RCC pillars/structures and grouted in cement mortar including grouting with screws/nails in RCC complete all as specified and directed.
Taking down cement plaster on bricks or stone wall/ceiling decayed surfaces of concrete from roof projection or RCC chajjas etc. including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
Taking down cement plaster and decayed concrete of any description, upto triple storey of building, from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with water proofing compound or mixed with WPC or PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) including necessary form work, fixing of GI wire netting 0.90mm dia and 12mm mesh in patches area n.exc 3.00 Sqm where ever required and finally finishing the surface with 15 mm thick cement plaster in CM 1:3 and applying two coats of white wash/colour wash/cement base paint/exterior emulsion paint to match the existing surface /finish, complete all as specified and as directed.
Rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces as in ceilings finished even and smooth without using extra cement, complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding removing serviceable tile to store and rubbish off the premises, complete all as specified and directed.
Non-skid ceramic coloured joint free tile of any shade and pattern of size 400mm x 400mm x 7mm thick as in floors set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and as directed.
Glazed coloured ceramic tiles of any shade and pattern on vertical surfaces of size 450mm x 300mm x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles over and including 10mm thick backing coat in CM 1:4, finished fair to received the tile, complete all as specified and directed. Notes for Tiling works :- 1. The colour, shade and pattern of tiles shall be approved by GE during the execution of the work. 2. The pattern of tiles may consist of combination of two or more different coloured tiles. 3. Removing and refixing of door shutter including necessary cutting of door shutter, if required during the execution of the work, shall be done by the contractor without any extra cost to the department. The rates quoted by the contractor shall be deemed to include this aspect.
Complete removal of the existing roof treatment, any type viz. tarfelt or membrane surface or roof tiles etc. including grubbing up of tree roots and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as directed :- (a) Applying 1st course of 15mm thick screed bed with cement mortar1:4 over concrete surface. (b) Applying 1st course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 2st coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 3rd course of APP (Atactic Polypropylene) modified polymeric membrane 3mm thick weight not less than 3.6 Kilogram/Square Metre with 160 Grams/Square Metre non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kilogram/Square Metre. (f) Applying 5th course by applying two coats of aluminium paint on top of the surface.
Complete removal of the existing sunken treatment including roughening and prepration old surfaces of concrete floor by picking, scurubbing down with steel brushes, sweeping clean and washing down with water to remove dust etc.and applying the following treatment :- (a)M & L 15 thick rendering on fair faces of brick work or cement surfaces in cm 1:4 with water proofing compound as per manufacturer instruction by weight of cement to sunken portion including wall of sunken portion with proper slope towards outside and finishing cement concrete or brick work surface even and smooth using extra cement finishing concrete including walls of sunken portion with proper slope all specified and as directed at site.
(b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3mm thick weight not less than 3.6 Kilogram/Square Metre with 160 Grams/Square Metre non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kilogram/Square Metre.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizental face of groove with cement mortar 1:3 complete all as specified and as directed.
Demolition of cement concrete un-reinforced of any description and in any position complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) with average thickness 50mm laid in two layers of 25mm thickness each finished even and smooth as in roof padding all as specified and as directed.
75mm thick PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in plinth protection finished even and smooth without using extra cement including joint filling by using mastic filling comprising one part of bitumen 85/25 mixed with three parts of coarse sand by weight complete all as specified and as directed.
Vitreous china Orissa pan of pattern, long pan size 580mm x 440mm, with ‘P’ or ‘S’ trap, front or back inlet and integral foot rest complete including lime concrete bedding and connection to drain or outgoing pipe and to flushing pipe, and anti siphon pipe, fixed in repair complete all as specified and directed.
10 litres capacity PVC low level flush cistern of approved make complete with PVC flush pipe and connection to water closet fixed in repairs complete all as specified and directed.
Bib taps, chromium plated cast copper alloy, with capstan head, fancy type, screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15mm, fixed in repairs, complete all as specified and as directed.
Angle valve cast copper alloy, fancy type, screwed down high pressure with capstan head fly handle, screwed with ends for iron pipe or unions of 15mm, fixed in repair, complete all as specified and directed.
PVC connection 60cm long fitted with PTMT nut and washer on both ends, fixed to 15mm bore iron pipes, complete all as specified and directed.
Dismantling water tanks exceeding 500 litres capacity but not exceeding 1000 litres, complete all as specified and directed.
Dismantling water tanks exceeding 250 litres capacity but not exceeding 500 litres, complete all as specified and directed.
Rotational moulded polyethylene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in position, including over flow and drain out pipe complete of 1000 litre capacity complete all as specified and directed.
Rotational moulded polyethylene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in position, including over flow and drain out pipe complete of 500 litre capacity complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required for repairs, cleaning etc. and hoisting if required reconnecting and refixing in position of water tanks exceeding 250 litres capacity but not exceeding 500 litres, complete all as specified and directed.
Ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to 20mm bore dia of pipe (Minimum weight 210gms) complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 15mm, complete all as specified and as directed.
Fixing only old steel tubing and connections in new or old position with all fittings retrieved from taking down here-in-before and fixed (walls, ceiling, floors, etc.) of 15 mm dia complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20mm, complete all as specified and as directed.
Fixing only old steel tubing and connections in new or old position with all fittings retrieved from taking down here-in-before and fixed (walls, ceiling, floors, etc.) of 20 mm dia complete all as specified and as directed.
Taking up or down 25mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 25mm, complete all as specified and as directed.
Dismantling cast iron or reinforced concrete drain pipes of 110mm bore, fixed with walls, under floor or in trenches all as specified and as directed.
PVC pipes, single socketed, in any length of 110mm bore with rubber ring joints, fixed in repair to walls with Mild steel clamps, complete all as specified and directed.
PVC (SWR) bend, any radius of 110mm bore, equal or unequal, complete all as specified and directed.
PVC (SWR) Junction (Single T) equal or unequal of 110mm bore, complete all as specified and directed.
PVC (SWR) Vent Cowl of 110mm bore, complete all as specified and directed.
Preparation Old plastered or previously treated surfaces of Walls and applying one coats of white wash, complete all as specified and directed.
Preparation new plastered or previously untreated surfaces of ceilings and applying three coats of white wash, complete all as specified and directed.
Preparation old decorated, plastered or unplastered surfaces of walls including brooming down or steel wire brushing, scrapping down smoke, soot, mould, moss and efflorescent salts and treating oil and greasy spot sand applying one coat of cement base paint, complete all as specified and directed.
Preparation new plastered surfaces of walls, chajjas, facias, parapets etc and applying two coats of cement base paint including one coat of cement primer complete all as specified and directed.
Preparation old decorated, plastered surfaces of walls including brooming down or steel wire brushing, scrapping down smoke, soot, mould, moss and efflorescent salts and treating oil and greasy spots and one coats of oil emulsion distemper complete all as specified and as directed.
Preparation new plastered surfaces of Walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
ASHOK KUMAR
M/s K.S. Constructions
NARESH KUMAR AND COMPANY
M/S Vishwakarma Builders
Bidder Name
M/S Vishwakarma Builders
M/s K.S. Constructions
ASHOK KUMAR
GENESIS INDIA
NARESH KUMAR AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .