Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹22.2 L+₹33,518 (1.53%)Rejected-Finance C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance Not a lowest bidder | |
| 3 | L3₹26.4 L+₹4.5 L (20.7%)Rejected-Finance | L3 | Rejected-Finance Not a lowest bidder | |
| 4 | L4₹30.7 L+₹8.8 L (40.3%)Rejected-Finance KHREW PULWAMA PAMPORE J K PIN 191103 | PULWAMA | JAMMU AND KASHMIR | 191103 | L4 | Rejected-Finance Not a lowest bidder | |
| 5 | L5₹32.4 L+₹10.6 L (48.3%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L5 | Rejected-Finance Not a lowest bidder |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
2 Nov 2021, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/O 56 APO
REPAIR REPLACEMENT OF ELECTRICAL FITTINGS, FIXTURES AND ALLIED WORKS AT ANANTNAG, TRAL, PULWAMA AND AWANTIPUR UNDER AGE EM OF GE 861 EWS
2021_MES_479379_1
GE 861 EWS-64/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹77,000
Yes
4 Dec 2021
4 Oct 2021
4 Nov 2021
4 Oct 2021
2 Nov 2021
19 Oct 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-2 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No-2 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per serial item No 2 here-in-before but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
S & F in repair switch piano flush button types 6 Amp, single pole, one way complete all as specified and directed.
S & F in repair switch socket combination 2 in 1, 3 pin, 6 Amp flush type, universal, complete all as specified and directed.
S & F in repair switch socket combination 2 in 1, 3 pin, 6 and 16 Amp, flush type universal complete all as specified and directed.
S & F in repair switch socket combination 2 in 1, 3 pin, 6 Amp flush type, universal with boxes, complete all as specified and directed.
S & F in repair switch socket combination 2 in 1, 3 pin, 6 and 16 Amp, flush type universal with boxes, complete all as specified and directed.
S & F in repair bell push, flush type, 5 Amp, complete all as specified and directed.
S & F in repair bell multi music type, AC 240 Volt, single pole, complete all as specfied and directed.
S & F in repair switch piano flush button types 16 Amp, single pole, one way complete all as specified and directed.
S & F in repair socket outlet 2 in 1, 3 pin, 6 Amps flush type, complete all as specified and directed.
S & F in repair socket out let, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts, complete all as specified and directed.
S & F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd., complete all as specified and directed.
S & F in repair lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
S & F in repair ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
S & F in repair modular one way switch 6 Amp 240 volts suitable for 1 module, complete all as specified and directed.
S & F in repair modular one way switch 16A, 1 module single pole, 230 volts complete all as specified & directed.
S & F in repair modular socket outlet, 6A-2/3 pin combined 2 module, 230 volts complete all as specified and directed.
S & F in repair modular socket outlet, 6A/16A-2/3 pin combined 2 module, 230 volts complete all as specified & directed.
S & F in repair modular step fan regulator electronic, 120W-2module, complete all as specified and directed.
S & F in repair modular white cover plate with frame, 2 module, complete all as specified and directed.
S & F in repair modular white cover plate with frame, 3 module, complete all as specified and directed.
S & F in repair modular white cover plate with frame, 6 module, complete all as specified and directed.
S & F in repair modular white cover plate with frame, 8 module, complete all as specified and directed.
S & F in repair modular metal flush box, 2 module, complete all as specified and directed.
S & F in repair modular metal flush box, 3 module, complete all as specified and directed.
S & F in repair modular metal flush box, 4 module, complete all as specified and directed.
S & F in repair modular metal flush box, 6 module, complete all as specified and directed.
Supply, installation, testing and commissioning of decorative ultra slim linear LED in replacement of 18 Watt white/warm, 4 ' long lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack including LED tube complete with inbuilt electronic driver , PCB , connector block etc including connecting up with three core twisted flexible copper conductor cable with suitable size LED tube including taking out old, all as specified and directed. Make : Havells Cat Part No LHEXBLP7PN1W018 or Equivalent in C&S/Bajaj/Halonix.
S & F in repair recess mounted 12 W white/warm colour LED pressure die-cast aluminium luminaire in powder coated white finish in round/square profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver including provision of fixing in ceiling with all items required for fixing, complete all as specified and directed.
S & F in repair square recess mounted 6 W white/warm colour LED pressure die-cast aluminium luminaire in powder coated white finish in square profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver including provision of fixing in ceiling with all items required for fixing, complete all as specified and directed.
S & F in repair square recess mounted 15 W white/warm colour LED pressure die-cast aluminium luminaire in powder coated white finish in square profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver including provision of fixing in ceiling with all items required for fixing, complete all as specified and directed.
S & F in repair square recess mounted 18 W white/warm colour LED pressure die-cast aluminium luminaire in powder coated white finish in square profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver including provision of fixing in ceiling with all items required for fixing, complete all as specified and directed.
S & F in repair 10 W LED wall decorative type fitting, warm/white colour in engineering plastic housing with clear prismatic diffuser including LED lamp and all accessories for fixing on wall, complete all as specified and directed.
S & F in repair LED bulk head fitting 9 W in engineering plastic housing with clear prismatic diffuser, including LED lamp and all accessories for fixing on wall, complete all as specified and directed.
S & F in repair LED lamp 9 W, complete all as specified and directed.
S & F in repair LED lamp 7 W, complete all as specified and directed.
S & F in repair LED lamp 20 W, complete all as specified and directed.
S & F in repair LED lamp 15 W, complete all as specified and directed.
S & F in repair LED lamp 7 W thread type, complete all as specified and directed.
Supply and fixing in repair MCB Distribution board , 240 volts triple pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection,fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply and fixing in repair MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections, complete all as specified & directed.
Supply & fixing in repair MCB, DP (Double Pole), AC, 240 volts, "B" series capacity 20 Amps to 32 Amps 10kA and making connections complete all as specified & directed.
Supply and fixing in repair MCB, SP, AC, 240 volts "B" series capacity of 63 Amps, 10kA and making connections, complete all as specified & directed.
Supply and fixing in repair MCB, SPN, AC, 240 volts "B" series capacity of 63 Amps, 10kA and making connections, complete all as specified & directed.
Supply and fixing in repair MCB, SPN, AC, 240 volts "B" series capacity of 32 to 40 Amps, 10kA and making connections, complete all as specified & directed.
Supply & fixing in replair of Isolator four pole 63 Amps 415 Volts with rupturing capacity 10 KA, complete as specified and directed.
Supply and fixing in repair MCCB four pole , 415 Volt, 100 Amps,25 KA , adjustable thermal & fixed magnetic setting complete all as specified and directed.
S & F in repair LED 30 Watt security light energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and impact resistance of IK07 complete all as per directed. Make Havells Cat Part No ENDURACITYLITEPLATSL30WLED757SASYBOPC or equivalent/CROMPTON GREAVES/GE.
S&F in repair LED garden light 12 W with opal diffuser and spun aluminium canopy finished in powder coated black from outside including suitable size of junction box and GI pipe 1.2mtr for complete connection with all accessories, complete all as specified and directed.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 1.0 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 1.5 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 2.5 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 4.0 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 6.0 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 6.0 Sqmm 2 core 1100 Volts grade as per site requirement of existing colour coding adopted.
Supply and laying in repair service cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 6 sqmm 2 Core nominal cross section complete all as specified and directed.
Supply and laying in repair service cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 10 sqmm 2 Core nominal cross section complete all as specified and directed.
Supply laying connecting and testing in repair 1100 volt graded heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 25 Sqmm normal cross section 3.50 core including suitable size lugs laid in trenches fixed to pole or passing through pipes incl all necessary clamps nuts, bolts and washers, complete all as specified and directed.
Supply laying connecting and testing in repair 1100 volt graded heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 10 Sqmm normal cross section 2.0 core including suitable size lugs laid in trenches fixed to pole or passing through pipes incl all necessary clamps nuts, bolts and washers, complete all as specified and directed.
Supply laying connecting and testing in repair 1100 volt graded heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 35 Sqmm normal cross section 3.50 core including suitable size lugs laid in trenches fixed to pole or passing through pipes incl all necessary clamps nuts, bolts and washers, complete all as specified and directed.
Supply laying connecting and testing in repair 1100 volt graded heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 16 Sqmm normal cross section 4.0 core including suitable size lugs laid in trenches fixed to pole or passing through pipes incl all necessary clamps nuts, bolts and washers, complete all as specified and directed.
S&F in repair connecting and testing change over switch single pole 230 volts on load of rating 16 Amp and including sheet enclosures complete including taking out to old u/s switch complete all as specified.
S&F in repair connecting and testing change over switch single pole 230 volts on load of rating 32 Amp and including sheet enclosures complete including taking out to old u/s switch complete all as specified.
S&F in repair connecting and testing main switch single pole 230 volts of rating 16 Amp and including sheet enclosures complete including taking out to old u/s switch complete all as specified.
S&F in repair connecting and testing change over switch four pole 415 volts on load of rating 63 Amp and including sheet enclosures complete including taking out to old u/s switch complete all as specified.
S&F in repair connecting and testing change over switch four pole 415 volts on load of rating 100 Amp and including sheet enclosures complete including taking out to old u/s switch complete all as specified.
S&F in repair connecting and testing main switch four pole 415 volts of rating 100 Amp and including sheet enclosures complete including taking out to old u/s switch complete all as specified.
S&F in replacement of capacitor 2.5 mfd AC 230 volts 50 Hz complete all as specified and directed.
S & F in repair bed switch 6 Amp, single pole, one way complete all as specified and directed.
Supply and fixing in repair Plug top 3 pin 15/16 amps 230 volts, complete all as specified and directed.
Supply and fixing in repair, Plug top 3 pin 5/6 amps 230 volts, complete all as specified and directed.
Supply and fixing in repair casing caping, 20mm, complete all as specified and directed.
Supply and fixing in repair casing caping, 25mm, complete all as specified and directed.
Supply and fixing in repair, PVC conduit pipe of 25mm bore dia medium grade, complete all as specified and directed.
Replacement of 5W LED lamp red, green, yellow lamp, complete all as specified and directed.
Supply and fixing in repair, PVC board 4"x4" with bakelite sheet, complete all as specified and directed.
Supply and fixing in repair, PVC board 7"x4" with bakelite sheet, complete all as specified and directed.
Supply and fixing in repair, teak wood board 4"x4" with bakelite sheet, complete all as specified and directed.
Supply and fixing in repair, teak wood board 7"x4" with bakelite sheet, complete all as specified and directed.
Steel water tubing, 40 mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
Supply and fixing in replacement PVC gang box 1 way, complete all as specified and directed.
Supply and fixing in replacement PVC gang box 2 way, complete all as specified and directed.
Supply and fixing in replacement PVC gang box 3 way, complete all as specified and directed.
Supply and fixing in replacement PVC gang box 4 way, complete all as specified and directed.
Supply and fixing in replacement PVC gang box for 15 Amp switch socket combination, complete all as specified and directed.
Supply & fixing in replacement of heating element AC 230 volt of rating 1500/2000 watt ISI marked triangular/circular type complete all as specified.
Supply and fixing replacement of old unserviceable thermostat switch with new thermostat switch for geyser AC 230 volt adjustable range, complete all as specified & directed.
M&L in repair earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-)14.50% (MINUS). (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Taking down old exhaust fan and fixing only exhaust fan 230mm to 250mm sweep PVC body with louvers, 240 volts AC single phase, 50 Hz, ISI marked, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material complete all as specified and directed.
Taking down old exhaust fan and fixing only exhaust fan 300mm sweep PVC body with louvers, 240 volts AC single phase, 50 Hz, ISI marked, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material complete all as specified and directed.
Taking down old geyser and fixing only water heater vertical type, stationary storage type of 25 ltr capacity 240 volts, including fixing arrangement nut bolts, washer/fasteners and finishing work etc, complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc, all as specified and directed.
Taking down old geyser and fixing only water heater vertical type, stationary storage type of 15 ltr capacity 240 volts, including fixing arrangement nut bolts, washer/fasteners and finishing work etc, complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc, all as specified and directed.
Taking down old geyser and fixing only water heater vertical type, stationary storage type of 50 ltr capacity 240 volts, including fixing arrangement nut bolts, washer/fasteners and finishing work etc, complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc, all as specified and directed.
Taking down old ceiling fan and fixing only ceiling fan 1200 mm sweep with blade and down rod, single phase , 240 volts ISI marked, including connection with three core copper wire etc, complete all as specified and directed.
Taking down old wall fan and fixing only wall fan 450mm high speed, 230 volts single phase with jerk free oscillation, smooth running, three blades, pull cords including fixing arrangement, complete all as specified and directed. Note for srl item No 95 to 101 :- Items will be issued under Sch 'B' free for fixing.
M/S A.N CONSTRUCTIONs
Javeed And Co
Ashfaq Construction Company
FG CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .