Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | ₹20.3 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹20.3 LRejected-Finance 0 JANAI JANAI CHANDITALA HOOGHLY WEST BENGAL 712304 UDYAM WB 07 0059321 | HOOGHLY | WEST BENGAL | 712304 | ₹20.3 L | L2 | Rejected-Finance NOT L1 BIDDER |
| 3 | L3₹20.3 LRejected-Finance 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | ₹20.3 L | L3 | Rejected-Finance NOT L1 BIDDER |
| Sl No | Description | Qty | Unit | WEST BENGAL ENGINEERING CO. L1 | EASTERN INDIA SALES AND SERVICE L3 | DAS ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Daily labour charges with bonus once in a year for operation and upkeepment of 3 nos 100 HP Centrifugal pump-motor sets , Vertical Submersible Dewatering Pump, Vacuum Pump along with 11/0.433 KV indoor type Sub-Station, comprising of 2 X 400 KVA Transformer, 3 Pole 12 KV 630 Amp drawout type VCB, LT Power Switch Board, LT Panels , Starters,Valves, Actuators, Flow Meter, level indicators , entire Yard lighting arrangement inside and outside of pump house including Operation of Gaseous Chlorination plant complete with all other electrical accessories and ancilliaries for 24 hours a day including guarding the whole installation.(6 Nos. Operator to be engaged) | 365 | Days | 4,260 ₹15.5 L | 4,266 ₹15.6 L | 4,263 ₹15.6 L |
| 2.00 | Periodical inspection twice in a month by electrical supervisor having valid suprevisor's certificate of competency from directorate of Electricity (Licensing board),govt. of West Bengal or under any other State Government of India along with Pump Technician / Supervisor. Each Visit should be recorded in the log book (with date and time) to be supplied by the agency and kept in the pump house building . The Supervisor requires to have thorough / in-depth instruction of all the electrical appliances to ascertain the healthy / fault free operational condition of each equipment i.e. VCB, 400 KVATransformer, LT Power switch Board, MCCBs L.T. PDB cum MCC panel, Pumps Valve, Actuators, relays, contactors, timers, SFU along with in house lighting system and checking of healthy condition of all drawout feeders . | 12 | Month | 15,074 ₹1.8 L | 15,150 ₹1.8 L | 15,100 ₹1.8 L |
| 3.00 | Day to day maintenance for upkeepment of all electrical & mechanical installation by engaging licensed electrician / machanic as and when required by supplying all necessary material and Cost of recharge of GSM system (@ Rs. 500.00 per Month) and cost of supply of Chlorine Test Kit etc. required to execute maintenance as well as guarding work. | 12 | Month | 13,453 ₹1.6 L | 13,600 ₹1.6 L | 13,500 ₹1.6 L |
| 4.00 | Testing of all relays viz. earth fault, over load, buchholz, and chacking of muster trip,trips circuit Supervisor, CT, PT, spring charging system, closing/trips coil, LT Power Switch Board, and breaker of L.T. Panel, , Di-electric test of transformer oil etc. including calibration of Ammeter, Voltmeter etc. by agency approved by Directorate of Electriciity/WBSEDCL/Any Power Generating Unit once in six month and submission of the Test Report to Department in each case. | 1 | Item | 1,29,500 ₹1.3 L | 1,30,000 ₹1.3 L | 1,29,800 ₹1.3 L |
Tender Value
Refer Docs
EMD Value
₹39,447
Closing Date
6 Feb 2026, 4:00 pmClosed
Executive Engineer,AMD P.H.E dte
Office of the Executive Engineer,Asansol Mechanical Division,Public Health Engineering Directorate,SEN-RALEIGH ROAD,PASCHIM BARDHAMAN,713305
Operation and maintenance of Pumping Machineries , Sub-Station(11/0.433 KV ,2 x 400 KVA Transformer), Yard Lighting and Gaseous Chlorination system at Boosting Station at Amdohi mouza under Gourbazar-Ichpur an jamgara-jagannathpur Water Supply Scheme
2026_PHED_988887_39
WBPHED/EE/AMD/ NIeT-40 of 2025-2026
Open Tender
Miscellaneous Works
Amdohi
Please refer Tender documents.
4 documents required · 4 mandatory
₹39,447
18 Mar 2026
16 Jan 2026
9 Feb 2026
16 Jan 2026
6 Feb 2026
16 Jan 2026
Daily labour charges with bonus once in a year for operation and upkeepment of 3 nos 100 HP Centrifugal pump-motor sets , Vertical Submersible Dewatering Pump, Vacuum Pump along with 11/0.433 KV indoor type Sub-Station, comprising of 2 X 400 KVA Transformer, 3 Pole 12 KV 630 Amp drawout type VCB, LT Power Switch Board, LT Panels , Starters,Valves, Actuators, Flow Meter, level indicators , entire Yard lighting arrangement inside and outside of pump house including Operation of Gaseous Chlorination plant complete with all other electrical accessories and ancilliaries for 24 hours a day including guarding the whole installation.(6 Nos. Operator to be engaged)
Periodical inspection twice in a month by electrical supervisor having valid suprevisor's certificate of competency from directorate of Electricity (Licensing board),govt. of West Bengal or under any other State Government of India along with Pump Technician / Supervisor. Each Visit should be recorded in the log book (with date and time) to be supplied by the agency and kept in the pump house building . The Supervisor requires to have thorough / in-depth instruction of all the electrical appliances to ascertain the healthy / fault free operational condition of each equipment i.e. VCB, 400 KVATransformer, LT Power switch Board, MCCBs L.T. PDB cum MCC panel, Pumps Valve, Actuators, relays, contactors, timers, SFU along with in house lighting system and checking of healthy condition of all drawout feeders .
Day to day maintenance for upkeepment of all electrical & mechanical installation by engaging licensed electrician / machanic as and when required by supplying all necessary material and Cost of recharge of GSM system (@ Rs. 500.00 per Month) and cost of supply of Chlorine Test Kit etc. required to execute maintenance as well as guarding work.
Testing of all relays viz. earth fault, over load, buchholz, and chacking of muster trip,trips circuit Supervisor, CT, PT, spring charging system, closing/trips coil, LT Power Switch Board, and breaker of L.T. Panel, , Di-electric test of transformer oil etc. including calibration of Ammeter, Voltmeter etc. by agency approved by Directorate of Electriciity/WBSEDCL/Any Power Generating Unit once in six month and submission of the Test Report to Department in each case.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.69 MB
BOQ_2419179.xls
BOQ • 0.28 MB
TandC.pdf
Tender Documents • 0.26 MB
2911.pdf
Tender Documents • 0.51 MB
Download all tender documents and submit your bid