Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.2 L+₹6.4 L (36.2%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | L2 | Rejected-Finance L2 |
Tender Value
₹25.1 L
EMD Value
₹50,240
Closing Date
3 Jan 2020, 6:00 pmClosed
Shri Niranjan Lal, GE(S) BTD
GE(S) BATHINDA BATHINDA MIL STN
CERTAIN REPAIR AND MAINTANCE AT SEWAGE PUMP HOUSE NO 1 TO 8 OF POCKET NO 10 AND LT PANEL BOARD UNDER AGE E/M -IV UNDER GE(S) BATHINDA AT BATHINDA MIL STN
2019_MES_305181_1
GE (S) BTD-47/2019-20
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (South) Bathidna
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE(S) BATHINDA
₹50,240
Yes
17 Feb 2020
9 Dec 2019
4 Jan 2020
9 Dec 2019
3 Jan 2020
23 Dec 2019
10 Dec 2019 - 18 Dec 2019
Amount
M&L Plugging underground sewer line (150 to 600 mm dia) in manholes at any depth and removing the same after desludging of sump well etc complete all as specified and direceted by Engineer-in-Charge.
De-watering the existing sewage water sump and Pumping well, soak wells/ pits/septic tanks and disposal of the same to the existing open drains/surrounding low lying areas nearby all as specified and as directed by Engineer-in-Charge ( T&P required for dewatering and disposal of effluient bring by the contractor ) complete all as specified & directed by the Engineer-in-Charge.
Cleaning & Desludging by removing semi solid sludge from the sump well / pump wells of any capacity at any depth at sewage pump house installation, manually or mechanically in foul condition including all necessary T&P required for removal of sludge and solid contents to any place out side the defence land without any extra cost etc complete all as specified and directed by Engineer-in-Charge. Note:- Measurement shall be done for the solid contents of sludge only and paid accordingly de-watering shall be measured and paid for under item No. 1here-in-before
S&F in replacement HRC fuse, link type of capacity 200 Amps, breaking capacity 80KA including taking down of old unsv. fuse etc complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement HRC fuse, bolt type of capacaity 250 Amps, breaking capacity 80 KA including taking down of old / Unsv. etc complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement star delta starter in sheet enclosures housing complete suitable for 25 HP, relay range 17-25 Amps including taking down of old starter etc complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement power contactor 3TF 47 suitable for 60 HP 415 V etc including internal wiring in panel complete all as specified and directed by Engineer-in-Charge.
S&F in replacement power contactor 3TF 50 suitable for 100 HP 415 V etc including internal wiring in panel complete all as specified and directed by Engineer-in-Charge.
S&F in replacement power contactor 3TF 49 for 75 HP 415 V etc including internal wiring in panel complete all as specified and directed by Engineer-in-Charge.
S&F in replacement power contactor 3TF 46 suitable for 60 HP 415 V etc including internal wiring in panel complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Bimettalic relay amp range (70-95A) etc including internal wiring in panel complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Bimettalic relay amp range (32-50A) etc including internal wiring in panel complete all as specified and directed by Engineer-in-Charge.
Preparation / scrapping of old painted surfaces of the DG Set of capacity 62.5 KVA including radiator, fuel tank, alternator assembly etc all parts of DG sets, complete degreasing and spray painting the same with two coats of approved synthetic enamel paint including writing SM/MES nos on DG sets of following capacities etc complete all as specified and directed by Engineer-in-Charge
Preparation / scrapping of old painted surfaces of the DG Set of capacity 25 KVA including radiator, fuel tank, alternator assembly etc all parts of DG sets, complete degreasing and spray painting the same with two coats of approved synthetic enamel paint including writing SM/MES nos on DG sets of following capacities etc complete all as specified and directed by Engineer-in-Charge
Preparation / scrapping of old painted surfaces of the LT panel complete and spray painting the same with two coats of approved synthetic enamel paint etc complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement Electronic timer switch (03-60 Sec) suitable for star delta starter 230-440V etc complete all as directed by Engineer-in-Charge. Make : Siemens / L & T / Legrand / Havells.
S&F in replacement switch disconnector fuse unit panel mounting type 400 Amps, 4 Pole, 415 Volt, including HRC fuses etc complete all as specified and as directed by Engineer-in-Charge. Make :Legrand/ Siemen / Havells.
Supply only forstable bleaching powder of 25 Kg bags etc complete all as specified and directed by Engineer-in-Charge.
Disconnecting mechnical connection and taking up existing Old/Unserviceable/Rusted CI non return valve of any size with chain pully arrangement from 9 meter deep underground pump well in floor foundation etc complete all as specified and directed by Engineer-in-Charge.
Disconnecting mechnical connection and taking up existing Old/Unserviceable/Rusted CI sluice valve of any size with chain pully arrangement from 9 meter deep underground pump well in floor foundation etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of cast iron NRV double flanged of size 300mm in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of cast iron NRV double flanged of size 150mm in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of cast iron NRV double flanged of size 100mm in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of cast iron sluice valve double flanged of size 250mm PN 1.6 brass spindle with wheel head, in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of cast iron sluice valve double flanged of size 150mm PN 1.6 brass spindle with wheel head, in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of cast iron sluice valve double flanged of size 100mm PN 1.6 brass spindle with wheel head, in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed by Engineer-in-Charge.
Taking up cast iron water mains (including all fitting), with flanged ends including disconnecting of pipes and fittings of 250mm dia from pump house well with all T&P required etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing cast iron pipes with flanged ends, centrifugally cast, class 'A' of size 250mm in any length fixing with pump house wall, depth of pump house is 9 meter with all clamps, nuts & bolts and T&P required including joint with jain sheet gasket testing after fixing etc complete all as specified and directed by Engineer-in-Charge.
Disconnecting of defective burnt elect motors and unserviceable pumps after removing all connection like electrical, earthing etc, removing of motors of capacity 05 to 100 HP from foundation with T & P required, taking to civil workshop for repair/strip opening and repairing of pumping sets any make and model including replacement of defective/unserviceable parts such as bearing, shaft, impeller, bush, Gland plate etc complete. Reassembling including oiling, greasing replacement of worn out nuts, bolts, gasket etc, refixing on its original position, making all connections, commissioning and testing at full load etc complete all as specified and directed by Engineer-in-Charge. Note :- (i) Cost of major parts like bearing shaft, bush, impeller gland plate etc shall be measured and paid separately. (ii) Cost of other minor item like gasket, nuts, bolts etc essential for functioning of pump is deemed to be included in quoted rate. (iii) Rewinding/repair of motor shall be measured and paid separately. (iv) Taking down and fixing of new MS frame is deemed to be included in quoted rate.
Removing of defective burnt winding of stator, cleaning of roter and starter, rewinding the stator of motor with super enameled copper wire of suitable turn and gauge as original including insulation material for insulation class ‘B’ varnishing, reassembling and testing of induction motors of capacities 5 HP to 25 HP, of any discharge capacity to the entire satisfaction, complete all as specified and directed by Engineer-In-Charge. Note :-Disconnection transportation and reconnection is deemed to be included under appropriate item of Sch 'A'.
Removing of defective burnt winding of stator, cleaning of roter and starter, rewinding the stator of motor with super enameled copper wire of suitable turn and gauge as original including insulation material for insulation class ‘B’ varnishing, reassembling and testing of induction motors of capacities 60 HP to 100 HP, of any discharge capacity to the entire satisfaction, complete all as specified and directed by Engineer-In-Charge. Note :-Disconnection transportation and reconnection is deemed to be included under appropriate item of Sch 'A'.
Disconnecting of unserviceable pumps after removing all electrical/mechnical connections etc of capacity 20 to 100 HP from 9 meter deep underground pump well foundation with T&P required, taking to civil workshop for repairing of pumping sets any make and model etc complete all as specified and directed by Engineer-in-Charge.
Strip opening of pump sets for repair of any make and model of capacity 20 to 100 HP including replacement of defective / unserviceble parts such as bearing shafts, impeller, bush gland plate, remetalling of shaft for fixing of MS bush / bearing etc refixing on its original position, making all connections, commissioning and testing at full load etc complete all as specified and directed by Engineer-in-Charge. Note : (i) Cost of major parts like ball bearing, bush, impeller, gland plate etc shall be measured and paid separately. (ii) Cost of other minor item like gasket, nuts, bolts etc for functioning of pump is deemed to be including in quoted rate.
Supply only Gland Bush suitable for pump set of capacity 75 HP pump etc complete all as specified and directed by Engineer-in-Charge. Make:- Kirloskar or any other make ISI Marked of same size suitable for fitting in existing pump set.
Supply only Gland Bush suitable for pump set of capacity 100 HP pump etc complete all as specified and directed by Engineer-in-Charge. Make:- Kirloskar or any other make ISI Marked of same size suitable for fitting in existing pump set.
Supply only Gland plates with studs/eye bolt suitable for pump set of capacity 75 HP pump etc complete all as specified and directed by Engineer-in-Charge. Make:- Kirloskar or any other make ISI Marked of same size suitable for fitting in existing pump set.
Supply only Gland plates with studs/eye bolt suitable for pump set of capacity 100 HP pump etc complete all as specified and directed by Engineer-in-Charge. Make:- Kirloskar or any other make ISI Marked of same size suitable for fitting in existing pump set.
Supply only Cast iron enclosed impeller suitable for pump set of capacity 75 HP pump etc complete all as specified and directed by Engineer-in-Charge. Make:- Kirloskar or any other make ISI Marked of same size suitable for fitting in existing pump set.
Supply only Cast iron enclosed impeller suitable for pump set of capacity 100 HP pump etc complete all as specified and directed by Engineer-in-Charge. Make:- Kirloskar or any other make ISI Marked of same size suitable for fitting in existing pump set.
Remetling, turning steel shaft of 60 HP pump set to prapex size and supply and fixing new CI Sleaves.
Remetling, turning steel shaft of 25 HP pump set to prapex size and supply and fixing new CI Sleaves.
Remetling, turning steel shaft of 10 HP pump set to prapex size and supply and fixing new CI Sleaves.
Supply only for replacement pump shaft suitable for 60 HP pumping set complete all as specified and directed by Engineer-in -Charge.Make:- Kirloskar or any other make ISI Marked of same size suitable for fitting in existing pump set.
Supply only for replacement bearing cover suitable for 60 HP pumping set complete all as specified and directed by Engineer-in -Charge.Make:- Kirloskar or any other make ISI Marked of same size suitable for fitting in existing pump set.
Supply only for replacement bearing cover suitable for 25 HP pumping set complete all as specified and directed by Engineer-in -Charge.Make:- Kirloskar or any other make ISI Marked of same size suitable for fitting in existing pump set. Make:- Kirloskar or any other make ISI Marked of same size suitable for fitting in existing pump set.
Supply only MS base frame channel for 100 HP pump set made out of medium channel of 150mm size as per existing design.
Supply only MS base frame channel for 60HP pump set made out of medium channel of 100mm size as per existing design.
Supply only MS base frame channel for 25 HP pump set made out of medium channel of 100mm size as per existing design.
Supply only ball bearing No 6411 etc complete all as specified and directed by Engineer-in-Charge.Make : SKF/NBC
Supply only ball bearing No 6313 etc complete all as specified and directed by Engineer-in-Charge.Make : SKF/NBC
Servicing and overhauling of 62.5 KVA, three phase, 415 Volts, 50 HZ,AC supply alternator of kirloskar make coupled with diesel engine set, by dismantling the alternator from foundation and taking out from coupling of engine by dismantling the damged rubber coupling pad, opening the complete assemlies by taking out the perised glass sleeve insulation paper, binding cloth and washing with carbon tetra chloride,decarbonising and cleaning the rotor with CTC solution, replacing the insulation paper sheet with new one of same size, replacing the glass sleeve of connection leads, binding the loose coil with binding cloth, varnishing and applying bectone on exciter coils and starter coils and heating complete with reassembling the unit and testing with megger and commissioning etc complete all as specified and directed by Engineer-in-Charge.
All as per SI item No 51 but of 40 KVA capacity.
All as per SI item No 51 but of 34 KVA capacity.
All as per SI item No 51 but of 25 KVA capacity.
S&F Air filter for air blower of 25 HP capacity.
S&F Air filter (outer) for 250 KVA capacity DG set.
All as per SI item No 56 but of 160 KVA capacity .
All as per SI item No 56 but of 70 KVA capacity .
All as per SI item No 56 but of 62.5 KVA capacity .
All as per SI item No 56 but of 40 KVA capacity .
All as per SI item No 56 but of 34 KVA capacity .
All as per SI item No 56 but of 25 KVA capacity .
S&F Air filter (inner) for 250 KVA capacity DG set.
All as per SI item No 63 but of 160 KVA capacity .
All as per SI item No 63 but of 70 KVA capacity .
All as per SI item No 63 but of 62.5 KVA capacity .
All as per SI item No 63 but of 40 KVA capacity .
All as per SI item No 63 but of 34 KVA capacity .
All as per SI item No 63 but of 25 KVA capacity .
Material and labour for disconnecting / dimantling of self starter from DG set 160 KVA capacity by removing all electrical connections and carring out to work shop for replacing the defecting parts, main shafts, bentex, pinion bearing, DE/CE bush, field coil assembly etc greasing and refitting and carrying back and connecting , testing complete all as specified and directed by Engineer-in-charge.
All as per SI item No 70 but of 70 KVA capacity.
All as per SI item No 70 but of 34 KVA capacity.
Repairing raditor for 34 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any, steam washing the radiator and refixing on the chasses etc complete all as specified and direceted by Engineer-in-Charge.
Supply only lead acid battery 12 V DC, 180 AH, rechargeable and maintenance free type Make- Exide Express/ Amararajaor/ Amran.
S&F Oil filter of 250 KVA DG set incl oil complete all as specified. Note:- Engine oil shall be measured and paid separetely under appropriate item in this BOQ.
All as per SI item No 75 but of 160 KVA capacity.Note:- Engine oil shall be measured and paid separetely under appropriate item in this BOQ.
All as per SI item No 75 but of 70 KVA capacity .Note:- Engine oil shall be measured and paid separetely under appropriate item in this BOQ.
All as per SI item No 75 but of 62.5 KVA capacity .Note:- Engine oil shall be measured and paid separetely under appropriate item in this BOQ.
All as per SI item No 75 but of 40 KVA capacity . Note:- Engine oil shall be measured and paid separetely under appropriate item in this BOQ.
All as per SI item No 75 but of 34 KVA capacity . Note:- Engine oil shall be measured and paid separetely under appropriate item in this BOQ.
All as per SI item No 75 but of 25 KVA capacity .Note:- Engine oil shall be measured and paid separetely under appropriate item in this BOQ.
S&F Fuel filter for 250 KVA capacity DG set.
All as per SI item No 82 but of 160 KVA capacity.
All as per SI item No 82 but of 70 KVA capacity .
All as per SI item No 82 but of 62.5 KVA capacity .
All as per SI item No 82 but of 40 KVA capacity .
All as per SI item No 82 but of 34 KVA capacity .
All as per SI item No 82 but of 25 KVA capacity .
M&L for ON LOAD change over switch in sheet metal encloser 415 V with side handle operation of rating 400 amp. Cat No. E- CSCS400DM4CO. Make C&S or equivalent in Havells/Standrad.
S & F 40mm bore, gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 3 phase , class 0.5, digital panel mounted Volt meter in 96 x 96 Sqm flush mounted case including internal wiring in panel. Make - Cat Part No NPAMEBRITV32 in HPL or equivalent in Siemens/Havells etc complete all as specified and directed by Engineer-in-charge.
S&F 3 phase , class 0.5, digital panel mounted Ammeter in 96 x 96 Sqmm flush mounted case including internal wiring in panel. Make - Cat Part No NPAMEBRITA32 in HPL or equivalent in Siemens/Havells
Supply and Replacement of Engine oil/ lubricant, 20 W 40 grade, suitable for Oil Change of DG set of any capacity and any make, complete all as specified and as directed by Engineer-In-Charge. Make:- SERVO/HP/BHARAT
S & F 25mm bore, gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F GI tubing medium grade with all fittings and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified and directed.
S & F GI tubing medium grade with all fittings and fixed to walls & ceilings or laid in floors, bore of pipe 25 mm complete all as specified and directed.
S&F MCCB 4 pole ,415volt ,adjustable type 250awith breaking capacity 36KA
S&F MCCB 4 pole ,415volt ,adjustable type 250awith breaking capacity 36KA
Supply and fixing sprinkeler of 15 mm dia including all accesseries like bend,tee,elbow etc complete and all specified and directed by Engineer-in-Charge.
SS CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .