| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC Being rate reasonable | |
| 2 | L2₹38.1 L+₹4.8 L (14.3%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹40.8 L+₹7.5 L (22.5%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹40.8 L+₹7.5 L (22.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹41.7 L+₹8.3 L (25.0%)Rejected-Finance 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
20 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(C) KIRKEE
GE(C) KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
REPAIR MAINTENANCE TO EXTERNAL LT ELECTRIC SUPPLY WITH CONVERSION OF SOME OH LINES INTO UG CABLES AT A PARK AND ARSENAL DEPOT OF CAFVD UNDER AGE EM II IN GE C KIRKEE
2021_MES_463192_1
8492/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(C) KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE(C) KIRKEE
₹98,000
Yes
22 Sept 2021
27 Jul 2021
23 Aug 2021
27 Jul 2021
20 Aug 2021
3 Aug 2021
27 Jul 2021 - 2 Aug 2021
60 days
Amount
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard / dense soil complete all as specified and directed By Engineer in charge.
Excavation in trenches n.exc. 1.5 mtr in wide and exc. 1.5 mtr but n. exc 3.0 m in depth and getting out in hard / dense soil complete all as specified and directed By Engineer in charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed By Engineer in charge.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cable providing with a layer of 8 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge.
Supplying and laying precast concrete LT cable cover, class LV, type flat , size 250mm x 150mm x 40mm complete for protection of underground cable all as specified and directed.
Supply and errect in replacement true vertical position steel tubular swaged poles complete with MS base plate of 6mm of size 300mm X 300mm finial taper plug,pole cap,bolts,nuts and washers screws,pole made out of ERW MS tubing as per IS-1161 and pole shall be as per IS-2713 Part II type 410 SP-31 (9.00 Mtrs Long) complete including one coat of red oxide zinc chrome primer with and including two coats of Aluminium paint for exposed surfaces and two coats of black bitumenous paint for portion embedded in concrete complete including dismantling old pole and removing from site all as specified and as directed by Engineer in charge. Note: Excavation and earth work ,PCC in foundation /plinth block/coping shall be measured and paid for separately.
Supplying, fixing, jointing and testing heat shrinkable Straight through joint, with and including jointing materials and necessary earth work suitable for 1100 V , XLPE LT cable of size 25-50 sqmm , 3.5/4 core, complete all as specified and as directed by Engineer in charge.
All as per item Ser No 8.00 above but cable of size 70-120 Sqmm, 3.5 core.
All as per item Ser No 8.00 above but cable of size 150-185 Sqmm, 3.5 core.
All as per item Ser No 8.00 above but cable of size 240-300 Sqmm, 3.5 core.
Supply, stringing, streaching and binding in replacement with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around the conductor etc complete all as specified & directed by Engineer in Charge.
Stringing only ACSR conductor including suitable binding wire for connecting the existing OH lines including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc complete all as specified & directed by Engineer in Charge.
M & L in replacement for cradle hexagonal , rectangular fabricated with GI wire 4 mm dia on extg OH line complete all as specified and directed by Engineer in Charge.
M & L in replacement for stringing GI earth wire 4 mm dia on extg OH line complete all as specified and directed by Engineer in Charge.
M&L for Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed by Engineer in Charge.
M&L for Dismantling of ACSR conductor LT or any type of pole complete all as specified and directed by Engineer in Charge.
M&L Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding, bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated with and including one primer coat and two coats of alluminium paint complete all as specified and directed by Engineer in Charge.
Supply and fix pin type porcelain, vitreous white, brown or green insulator including galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engineer in Charge.
Supply and fix shackle type porcelain, vitreous white, brown or green insulator including galvanised mild steel straps, wahsers, insulator bolts, wahsers and nuts, height in 100 mm, maximum dia 115 mm, section of straps in 31 x 5 mm, dia of bolts 14 mm, as working pressure 1100 volts complete all as specified by Engineer in Charge.
S & F stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 65 x 90mm clearance of hole 16 mm & other accessories all as per MES SSR, Plate No.1 including necessary MS clamps, excavation earth work & PCC work complete all as specified and directed.
Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed by Engineer in charge for following size:-
10 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 4 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
300 Sqmm 3.5 core
Note for Item No 22: (i) During excavation for laying of cable, any damage to the existing services will be made serviceable by contractor without any extra cost, within 24 hrs after notifying the same by Engineer in charge.
S&F tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed by Engineer in charge for the following bores :-
100 mm bore
80 mm bore
50 mm bore
M&L for cutting through existing bituminous road /PCC/floor/ along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finishes complete all as specified and directed by Engineer in charge. Note: GI Pipe will be measured and paid seperately.
M&L for cement concrete 1 : 4 : 8 Type D-2 (using 40 mm graded aggregate) as in foundation for pole including necessary form work complete all as specified and directed by Engineer in charge.
M&L for cement concrete 1 : 2 : 4 Type B-1 (using 20 mm graded aggregate) as in coping to pole including necessary form work complete all as specified and directed by Engineer in charge.
M & L for painting to steel tubular swaged/ RCC pole of LT 1100 Volt overhead lines (9 mtr long) with two coat of aluminium paint complete with including cross arm/clamps etc complete all as specified and directed by Engineer in charge.
Ditto above item No-27.00 but 11 mtrr long HT pole with two coat of aluminium paint complete with cross arms, clamps etc steel/ RCC 11KV complete all as specified and directed by Engineer in charge.
Ditto above item No-27.00 but Two pole structure Steel/RCC, with two coat of aluminium paint with cross arms, clamps, structure etc 11/ 1.1KV HT/ LT complete all as specified and directed by Engineer in charge.
Ditto above item No- 27.00 but Four pole structure Steel/RCC, with two coat of aluminium paint with cross arms, clamps, structure,etc 11/1.1 KV HT/LT complete all as specified and directed by Engineer in charge.
Notes for item No-27.00 to 30.00 : Rate quoted by bidder shall be inclusive of following:- (a) Scraping out wornout old paint and preparing the surface smooth for applying for paint. (b) Writing the pole & feeder no. on each pole all as directed at site.
M & L for stone aggregate of nomial size 40 mm size and spreading evenly in the Sub Stn area complete all as directed by Eng-in-Charge at site.
M&L for Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 2 mtr from farthest conductor on pole including removing of cut branches and cleaning of site complete all as directed by Engineer in Charge.
Note :- (a) The trees branches etc will be removed from site and stack at location as directed by Engineer in Charge. (b) Per span shall be measured as the distance beween two poles. © Contractor shall employ sufficient labour to complete the job with in time as directed. (d) Contractor shall be responsible for providing necessary safety measures to the labour for the job. (e) Contractor supervisor shall take proper shut down from MES installation before starting the work and clear it before resuming power supply. (f) The contractor shall provide proper tools and safety devices to his staff for prooning of trees.
M&L in replacement of MCCB of 4 pole 100 Amps 415 Volts with breking capacity 25 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
M&L in replacement of MCCB of 4 pole 125 Amps 415 Volts with breking capacity 25 KA complete with thermal and magnetic release all as specified and directed by Engr-in-charge.
M&L in replacement of MCCB of 4 pole 160 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
M&L in replacement of MCCB of 4 pole 200 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
M&L in replacement of MCCB of 4 pole 250 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
M&L in replacement of MCCB of 4 pole 400 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
M&L in replacement of MCCB of 4 pole 630 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release all as specified and directed by Engr-in-charge.
S&F Gate Light fittings, decorative type, LED 40Watt, with and including all necessary fixing material on gate posts, complete and connected to nearest electric pole complete all as specified and as directed by Engineer in charge. Make: Crompton (Cat No: LPTC-40-CDL ) or Equivalent in list of make as approved by GE.
S&F Energy efficient LED street light fittings, 72 Watt, die-cast aluminium body with power LED and dirver with IP66 protection and 10KV built-in-surge protection device complete all as specified and as directed by Engineer in Charge. Make: Crompton (Cat No: LSTP-72-CDL-M ) or equivalent in list of make as approved by GE.
S&F street light bracket made out of GI tubing 40mm bore, 1.5 metre long, bent to shape as directed, including suitable MS clamp with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole, duly painted with two coats of aluminium paint complete all as specified and as directed by Engineer in Charge.
S&F LED bollard light fittings, LED 10Watt, including all necessary fixing material and earth work complete and connected to nearest electric pole complete all as specified and directed by Engineer in Charge. Make: Crompton (Cat No: LBLSN-10-CDL ) or equivalent in list of make as approved by GE.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6 Sqmm complete all as specified and as directed by Engineer in charge.
Supply, installation, commissioning and testing of outdoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar 500 Amps capacity, pre-wired and CPRI approved, fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. The feeder pillar shall be comprising of the followings:-
(a) MCCB 4 pole 320A, 36kA, thermal & magnetic release - 02 Nos (b) Manual changeover opern execution, 4 pole, 315 A- 01 Nos Make: L&T(Cat No: CO33150OSOO) or C&S/ Schneider (c) Digital Amp meter, volts meter, indicator set (RYB) - 02 Set
(Note : The panel Box shall be designed in such a way that saperate compartmet to each switch gear & Bus bar and adequate workable space is made available inside the compartments
Supply, installation, commissioning and testing of outdoor type Bus Bar LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar of 400 Amps capacity, fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate, front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work complete all as specified and as directed by Engineer in charge.
Supply, installation, commissioning and testing of outdoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar 600 Amsp capacity, pre-wired and CPRI approved, fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. The feeder pillar shall be comprising of the followings:-
Incommer:- MCCB 4 pole 400A, 36kA, thermal & magnetic release - 01 Nos Outgoing: (a) MCCB 4 pole 320A, 36kA, thermal & magnetic release - 01 Nos (b) MCCB 4 pole 250A, 36kA, thermal & magnetic release - 01 Nos (c) MCCB 4 pole 100A, 36kA, thermal & magnetic release - 02 Nos (d) MCCB 4 pole 63A, 36kA, thermal & magnetic release - 02 Nos (e) provn of rail mounting for MCB fixing (f) Digital Amp meter, volts meter, indicator set (RYB) - 01 Set
(Note : The panel Box shall be designed in such a way that separate compartmet to each switch gear & Bus bar and adequate workable space is made available inside the compartments
Supply, installation, commissioning and testing of outdoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar of 500 Amps capacity, pre-wired and CPRI approved, fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. The feeder pillar shall be comprising of the followings:-
Incommer:- MCCB 4 pole 320A, 36kA, thermal & magnetic release - 01 Nos Outgoing: (a) MCCB 4 pole 250A, 36kA, thermal & magnetic release - 01 Nos (b) MCCB 4 pole 100A, 25kA, thermal & magnetic release - 02 Nos (c) MCCB 4 pole 63A, 25kA, thermal & magnetic release - 02 Nos (d) provn of rail mounting for MCB fixing (e) Digital Amp meter, volts meter, indicator set (RYB) - 01 Set
(Note : The panel Box shall be designed in such a way that separate compartmet to each switch gear & Bus bar and adequate workable space is made available inside the compartments
Dismantling of stone sett paving laid bedded and pointed in cement mortar of any description or thickness complete all as specified and directed by Engineer in charge.
Demolition of cement concrete in ground floors and paving n exc 15 cm thickness ( below or above ground level) complete all as specified and directed by Engineer in charge.
M&L for cement concrete 1:2:4 type B-2 ( using 40 mm graded agg) as in sub base for stone sett paving upto 150 mm thick complete all as specified and directed by Engineer in charge.
M&L for stone sett flooring with stone setts of size 200 to 250 mm long ,150 to 200 mm wide and 150 mm deep and sides dressed, bedded in cement mortar 1:3 joints 20 mm thick ; grouted in cemnt mortar 1:2 with an admixture of metallic floor harder 5% by weight of cement and struck flush complete all as specified and directed by Engr-in-Charge.
All as item no 52.00 above but except stone complete all as specified and directed by Engr-in-Charge.
M&L for flush pointing 20mm thich to stone sett paving any decription in cement mortar 1:3 with an admixture of metallic floor harder 5% by weight of cement all as specified an directed by Engineer in charge.
Removal of debris ( concrete, broken stone etc.) to out side defence land (distance exceeding 1.5 KM but 5KM from the site ) an depositing where directed complete all as specified and directed by Engineer in charge.
M&L earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR2020-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified by Engineer in charge. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
M&L for connecting galvanised iron ( GI ) strip 32 X 6 mm, in replacement to the existing earthing to eqpts complete all as specified.
metro electrical services
M/S. Niksun Electro-Infra Private Limited
M/S. OM ENTERPRISES
Leo Enterprises
SHAILENDRA B TULSANI
SOURABH ENGINEERS
Radha Engineering Services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .