Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹13.0 L
EMD Value
₹25,960
Closing Date
10 Feb 2026, 4:00 pmClosed
Executive Engineer (E)
O/o Ex-Engineer, M-33kV, 1st Floor, 33kV ESS Kidwai Nagar West, New Delhi-110023
Urgent Repair and Overhauling of Faulty OLTC of Power Transformer (PTR-1, BHEL Make) at Vidyut Bhawan New (Special Repair)
2026_NDMC_286046_1
13 /EE ( M-33kV )/2025-26
Open Tender
Electrical Works
Percentage
30 days
ESS Vidyut Bhawan
As per NIT
2 documents required · 2 mandatory
₹0
₹25,960
7 May 2026
2 Feb 2026
10 Feb 2026
2 Feb 2026
10 Feb 2026
2 Feb 2026
50MVA 66/33kV Power Transformer OLTC Dismantling, Repair & Replacement: Draining of oil from OLTC vessel & safe storage in drums, Opening of OLTC head cover, dismantling of gear system, Lifting OLTC insert with mobile crane, Replacement of damaged moving & fixed contacts of R-phase changeover switch, Replacement of top cover & inspection window gaskets, Fixing & alignment of drive shaft, operation check on tap positions 1 to 17 and 17 to 1.
50MVA 66/33kV Power Transformer overhauling including Transformer Drying & Oil Processing – Dismantling of conservator / Buchholz relay pipeline, Fixing of dummy plates on radiator bank header pipe, replacement of all gasket, Transformer dry-out using vacuum pump & dry-air generator (dew point ≤ -60°C), Two cycles of vacuum drying & dew point monitoring (12 hrs each), Oil filtration, degassing & moisture removal, Filling of tested oil under vacuum, refilling conservator & radiator, Circulation of oil (4 cycles) maintaining ≥ 60°C temp. Painting of 50 MVA power transformer with glossy paint.
Testing & Commissioning of 50 MVA power Transformer Pre-commissioning electrical tests: i) Tan Delta, Capacitance on bushings & windings, ii) Turns ratio test on all taps, iii) Magnetic balance at normal tap, iv) Vector group verification, v) Short circuit impedance test, vi) IR/PI measurement (15 sec, 60 sec, 600 sec), vii) Winding resistance measurement (tap 1–9B), viii) Oil quality tests: BDV, Moisture (ppm), Resistivity, DGA, ix) Final inspection & report for energization of Power Transformer.
ADD: GST @ 18%
stage.html
html • 0.02 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.46 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.76 MB
BOQ_378638.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].