Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹1.4 Cr+₹22.7 L (18.9%)Admitted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Admitted-Finance | |
| 3 | L3₹1.5 Cr+₹25.5 L (21.3%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹1.5 Cr+₹28.6 L (23.9%)Admitted-Finance 67 A HAFIZALI BAHADUR KHAN MARG SURAJI COMPOUND BEHIND KHATAU MILL BYCULLA W MUMBAI 400011 BRITE INDUSTRIES 67 A HAFIZALI BAHADUR KHAN MARG SURYAJI COMPOUND BEHIND KHATAU MILL MUMBAI | MUMBAI | MAHARASHTRA | 400011 | L4 | Admitted-Finance | |
| 5 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | Rejected-Technical Not Meeting Criteria firm have been declared NO in WLR published by CESC on dt 07 Sep 2026 |
| Sl No | Description | Qty | Unit | AIRFRAME L1 | BRITE INDUSTRIES L4 | DARSHAN CONSTRUCTION Co. L3 | Shree Ayyappa Engineering L2 |
|---|---|---|---|---|---|---|---|
| 1.00M&L for carefully disconnecting electrical connections from all BER VRF/VRV indoor and outdoor units, disconnecting refrigerant piping connections, taking down the existing BER VRF/VRV indoor and outdoor units from their installed positions, transporting and depositing the same to the MES store yard of the following, complete all as specified and directed. | |||||||
| 1.01 | (a) Indoor units ranging from 1.33 TR to 4.12 TR | 21 | Each job | 30,000 ₹6,30,000 | 1,500 ₹31,500 Lowest | 1,510 ₹31,710 | 2,000 ₹42,000 |
| 1.02 | (b) Ductable indoor units of 6.54 TR capacity | 4 | Each job | 40,000 ₹1,60,000 | 2,600 ₹10,400 Lowest | 2,610 ₹10,440 | 5,000 ₹20,000 |
| 1.03 | (c) Outdoor units ranging from 12 HP to 18 HP | 6 | Each job | 50,000 ₹3,00,000 | 2,100 ₹12,600 | 2,510 ₹15,060 | 2,000 ₹12,000 Lowest |
| 2.00Outdoor Unit: Supply, installation, testing and commissioning of modular type, 100% inverter, Variable Refrigerant Flow (VRF) outdoor unit comprising hermetically sealed inverter-driven variable speed scroll compressor(s), complete with high-efficiency, low-noise condenser fan(s) with guard and motor, heat exchanger with corrosion-resistant coated fins, powder-coated casing, liquid line strainer, filter drier, thermostats and all other standard accessories, suitable for interconnection with compatible VRF indoor units. The outdoor and indoor units shall be integrated through the manufacturer's communication wiring system with central monitoring and control. The unit shall be factory wired, tested and charged with R410A refrigerant before dispatch. The outdoor unit shall be compatible with Building Management System (BMS) through MODBUS protocol, capable of delivering 100% cooling capacity at an ambient temperature of 43°C and shall have a minimum COP of 3.6 under design conditions, complete all as specified and directed. | |||||||
| 2.01 | 18 HP | 2 | Each | 11,50,000 ₹23,00,000 | 6,48,800 ₹12,97,600 | 6,48,020 ₹12,96,040 Lowest | 7,34,675 ₹14,69,350 |
| 2.02 | 16 HP | 2 | Each | 10,75,000 ₹21,50,000 | 5,76,700 ₹11,53,400 | 5,76,050 ₹11,52,100 Lowest | 6,84,675 ₹13,69,350 |
| 2.03 | 12 HP | 2 | Each | 9,50,000 ₹19,00,000 | 4,32,200 ₹8,64,400 | 4,32,050 ₹8,64,100 Lowest | 6,04,675 ₹12,09,350 |
| 3.00Indoor Units: Supply, installation, testing and commissioning of VRF-based 4-way cassette indoor units of the capacities mentioned below, complete with fan section, fan and cooling coil suitable for R410A refrigerant, electronic expansion valve (EEV), return air filter, insulated drain tray, cordless remote controller, necessary controls and all standard accessories, complete all as specified and directed by the Engineer-in-Charge. | |||||||
| 3.01 | 1.33 TR / 459 CFM | 8 | Each | 38,300 ₹3,06,400 | 37,900 ₹3,03,200 | 37,590 ₹3,00,720 Lowest | 65,000 ₹5,20,000 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
2 Sept 2026, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
SPECIAL REPAIRS and REPLACEMENT OF VRF VRV AC PLANT AGAINST BER AT HQ WNC under GE KUNJALI
2026_MES_781173_1
8547/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) Kunjali
Class B Category c (i)
7 documents required · 7 mandatory
₹1,000
GE (NW) Kunjali
₹2.2 L
Yes
12 Oct 2026
28 Jul 2026
4 Sept 2026
28 Jul 2026
2 Sept 2026
24 Aug 2026
28 Jul 2026 - 29 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1M&L for carefully disconnecting electrical connections from all BER VRF/VRV indoor and outdoor units, disconnecting refrigerant piping connections, taking down the existing BER VRF/VRV indoor and outdoor units from their installed positions, transporting and depositing the same to the MES store yard of the following, complete all as specified and directed. | |||||
| 1.01 | (a) Indoor units ranging from 1.33 TR to 4.12 TR | - | Each job | - | - |
| 1.02 | (b) Ductable indoor units of 6.54 TR capacity | - | Each job | - | - |
| 1.03 | (c) Outdoor units ranging from 12 HP to 18 HP | - | Each job | - | - |
| 2Outdoor Unit: Supply, installation, testing and commissioning of modular type, 100% inverter, Variable Refrigerant Flow (VRF) outdoor unit comprising hermetically sealed inverter-driven variable speed scroll compressor(s), complete with high-efficiency, low-noise condenser fan(s) with guard and motor, heat exchanger with corrosion-resistant coated fins, powder-coated casing, liquid line strainer, filter drier, thermostats and all other standard accessories, suitable for interconnection with compatible VRF indoor units. The outdoor and indoor units shall be integrated through the manufacturer's communication wiring system with central monitoring and control. The unit shall be factory wired, tested and charged with R410A refrigerant before dispatch. The outdoor unit shall be compatible with Building Management System (BMS) through MODBUS protocol, capable of delivering 100% cooling capacity at an ambient temperature of 43°C and shall have a minimum COP of 3.6 under design conditions, complete all as specified and directed. | |||||
| 2.01 | 18 HP | 2 | Each | - | - |
| 2.02 | 16 HP | 2 | Each | - | - |
| 2.03 | 12 HP | 2 | Each | - | - |
| 3Indoor Units: Supply, installation, testing and commissioning of VRF-based 4-way cassette indoor units of the capacities mentioned below, complete with fan section, fan and cooling coil suitable for R410A refrigerant, electronic expansion valve (EEV), return air filter, insulated drain tray, cordless remote controller, necessary controls and all standard accessories, complete all as specified and directed by the Engineer-in-Charge. | |||||
| 3.01 | 1.33 TR / 459 CFM | 8 | Each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
NIT.pdf
Tender Documents • 0.39 MB
03 gENPAGES.pdf
Tender Documents • 0.90 MB
04 ps.pdf
Tender Documents • 0.37 MB
05 Appndx A.pdf
Tender Documents • 0.39 MB
06 CESC MAKES BR-EM.pdf
Tender Documents • 0.52 MB
07 PS APPX C to G Revised.pdf
Tender Documents • 0.81 MB
BOQ_875091.xls
BOQ • 2.53 MB
8547.pdf
PDF • 0.24 MB
8574.pdf
PDF • 0.53 MB
8574.pdf
PDF • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .