Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹19.5 L+₹99,902 (5.41%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹19.9 L+₹1.4 L (7.81%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹42,600
Closing Date
15 Sept 2020, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-67 OF 2019-20 SPECIAL REPAIRS TO TOILET BLOCK IN OTM ACCOMMODATION BUILDING NO. P-262 AT MILITARY STATION FAZILKA (3RD CALL)
2020_MES_323899_3
CA NO. CWE SGNR - 67 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
ABOHAR
Class E
Category a(i)
10 documents required · 10 mandatory
₹500
GE ABOHAR
₹42,600
Yes
7 Oct 2020
18 Aug 2020
17 Sept 2020
18 Aug 2020
15 Sept 2020
1 Sept 2020
Amount
Taking down chowkats or frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats with shutters(without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm) removing to store complete all as specified and directed by Engineer-in-Charge.
Taking down shutters and refixing of shutter of any description exc 1 sqm and n exc 2 sqm each in the same opening complete all as specified and directed by Engineer-in-Charge.
M & L for Pieces, small let in for making good where hinges, etc. have been removed from chowkhals or frames, joinery, etc. including painting or oiling to match, if required complete all as specified and directed by Engineer-in-Charge.
S&F for PVC door frame of size 50x47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and designs complete all as specified and directed by Engineer-in-Charge.
S&F for Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC’C’ channel heaving a PVC sheet strip of 20mm width suck inside complete all as specified and directed by Engineer-in-Charge.
S&F for Aluminium handle cast type anodized 125 mm long complete all as specified and directed by Engineer-in-Charge.
S&F for Aluminium anodized barrel tower bolt of extended section and fixed 200 mm long complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm long butt hinges extruded almiunium alloy with galvanised mild steel hinges pin, anodised complete all as specified and directed by Engineer-in-Charge.
S & F for pressed steel door frames with one or more rebates including necessary fixing lungs hinges lock strike plate etc complete all as specified size of frame 105 x 60mm complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:2:4 type B–1 filling of pressed steel frame and hold fast blocks etc complete all as specified and directed by Engineer-in-Charge.
S & F for Flush shutters, 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides as per SSR Part – I complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel barrel tower bolt 200mm long stove enameled black complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel pressed handles oval type enameled black 150mm size complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel sliding door bolt 300 mm long plate type stove enameled black with bright bolt not less than12mm dia complete all as specified and directed by Engineer-in-Charge.
M&L for preparing surface of wood and wood based surface new on any description not other wise described over 10cm with or grith and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surface over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old painted wooden surfaces of any description over 10 cm width of girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
S&F in repair, steel ventilators fixed type 1.25mm thick box type (Primer Coat) ERW hollows 'P' section of size 60mm x 25mm single rebated optional full glass or wire mesh and making good dismantled portion in PCC (1:2:4) type B1 complete all as specified and directed by Engineer-in-Charge. Note : Glass, Wiremesh and painting shall be measured and paid separately under appropriate item of BOQ
Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 15mm thik on fair faces of brick work in cement mortar 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10 mm thick in cement mortar 1:4 om fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic coloured joint free tiles in vertical surface 450x300x7mm thick over 10mm thick plaster in CM 1:4 in walls set and jointed in neat cement slurry and pointed in white or coloured cement complete all as specified and directed by Engineer-in-Charge.
M&L for non-skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type B-0, 1:2:4 using 12.5mm graded stone aggregate as in floors 25 mm thick for tiles complete all as specified and directed by Engineer-in-Charge.
M&L for ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball with minimum weight 210 Grms screwed for 20mm bore iron pipe supplied and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in repairs, rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 1000 Litres complete all as specified and directed by Engineer-in-Charge.
S&F for galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width or aperture 1.18mm complete all as specified and directed by Engineer-in-Charge.
S & F for 3 mm thick pin headed sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-Charge.
S&F in repair, bib taps long body, 15mm bore, fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, 15mm bore CP Angle cock one way chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair tubular towel rail 20mm dia, D type 60cm long between flanges brass bran chromium plated complete all as specified and directed by Engineer-in-Charge.
S&F in repair, CP grating suitable for 75mm / 100mm bore floor trap and fixed with white cement complete all as specified and directed by Engineer-in-Charge.
S&F for PVC connection both side brass unions internal for size 15mm dia and 450mm long complete all as specified and directed by Engineer-in-Charge.
M&L for applying three coats of white wash on newly plastered or unplastered wall surfaces including preparationof surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed by Engineer-in-Charge.
S&F for in Guard bar 12 mm thick square bars with (primer coated ) with 25 mm x 3 mm thick MS Flat all around the frame of windlow / ventilator complete all as specified and directed by Engineer-in-Charge. Note :Painting shall be measured & paid seperately under appropriate items.
Dismantling of brick work built in cement mortar complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with fly ash modular bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
S&F for Cast iron floor trap 100 mm bore with grating including jointing to waste pipe and fixed with PCC 1:2:4 complete all as specified and directed by Engineer-in-Charge.
Dismantling of CI pipes of any size fixed to wall etc complete all as specified and directed by Engineer-in-Charge.
S&F for Cast iron soil 100 mm bore , waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
Refixing of cast iron 100mm bore, waste and vent pipe, in any length with without ears, with cement joints, fixed to walls complete all as specified and directed by Engineer-in-Charge.
Refixing of cast iron 75mm bore, waste and vent pipe, in any length with without ears, with cement joints, fixed to walls complete all as specified and directed by Engineer-in-Charge.
S&F for Cast iron soil 75 mm bore , waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm cast iron sanitary connection socket to fit WC out-let, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 75mm bore Cast iron cowls, complete all as specified and directed by Engineer-in-Charge.
S&F for Cast iron 100mm bore Branch pieces, single (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm CI Bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing of 25 to 32 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for mild steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for mild steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for mild steel tubes of size 25 mm bore (medium grade) galvanised with all fittingsand fixed complete all as specified and directed by Engineer-in-Charge.
M&L for 50mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection complete all as specified and directed by Engineer-in-Charge.
Taking down eaves gutters and rain water pipes complete all as specified and directed by Engineer-in-Charge.
S & F for PVC (SWR) pipes and single socketed in any length with rubber ring joints fixed to walls 110mm Dia complete all as specified and directed by Engineer-in-Charge.
S & F for PVC (SWR) bends any radius bore of 110 mm complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:5:10) using 40mm graded burnt bricks aggregate as in foundation filling & mass concrete or as in shunken floor complete all as specified and directed by Engineer-in-Charge.
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below complete all as specified and directed by Engineer-in-Charge. :- (a) applying 15 mm plaster in CM 1:3 with WPC on raised verticle surface (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc. (c) Creating fillet coving of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) Cement concrete 1:4:8 over the coating as per requirment (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete as specified.Plan area shall be measured
S&F in repaire PVC low level flushing system 10 Ltr capacity with flush pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, sheet cover complete all as specified and directed by Engineer-in-Charge.
S & F repair vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim complete all as specified and directed by Engineer-in-Charge.
S&F for vitreous china Half stall urinals flat back white minimum with grating and union for discharge pipe , providing & fixing plugs, bedding urinal against wall in CM 1:2 , securing urinal to plugs with & incl 60mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with nbrackets, flush pipe, grating and union for discharge pipe complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, brass chromium plated central hole basin mixer with regular spout, popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engineer-in-Charge. Make : Jaquar / ESS ESS / Hindware
S&F in repairs, brass chromium plated wall mixer with non telephonic shower arrangement for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. Make : ESS ESS Cat Part No. TM-115 or equivalent make as approved by GE
S & F in repairs for brass chromium plated shower rose 125 mm size with swivel joint including fixing to 15 mm dia steel pipe or union complete all as specified and directed by Engineer-in-Charge.
S & F for vitreous china wash basins, white, flat back or angle back type size 550 x 400mm , including cutting for and pinning in ends of brackets complete all as specified and directed by Engineer-in-Charge.
M&L for Granite (of any type) tiles 18mm to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including 18mm-20mm thick rendering in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for washed stone grit plaster 1:4 ( 1 cement : 4 coarse sand ) furrowing the under layer @3kg of cement per square metre, top layer 15 mm cement plaster 1:1/2:2 ( 1 cement : 1/2 coarse sand : 2 stone chipping 10 mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings. complete all as specified and directed by Engineer-in-Charge. Note : payment for providing grooves shall be made seperately
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed by Engineer-in-Charge.
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface all as spd and directed by Engr-in-Charge. Note: Rate for making good shall be deemed to be included in above item rate.
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exc 1.5 mtr wide & not exc 1.5 mtr in depth for pipe line, cable trenches not exc1.5 mtr in depth & getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading leveling, watering and well ramming in layers each not exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus spoil to a distance not exc 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning for underground cable using fine sand 8cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness shall be considered for payment purpose
M & L for old size burnt bricks of common burnt clay sub class B designation 75 complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring complete with 1.5 Sqmm (Nominal area) PVC insulated multustranded fire retardant (low smoke unsheathed and multicore copper conductor cable with colour code ISI marked and including PVC concealed conduict ISI marked and conduit fittings for one light point/fan point/5 Amps switch socket/bell/engagement light controlled by one switch including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified and directed by Engineer-in-Charge. Note : Cost of MS sunken box and bakelite sheet included in the rate
All as per Srl item No. 83 here-in-before but one three pin socket outlet 5 Amps on the independent board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 83 here-in-before but one three pin socket outlet 5 Amps on the same board complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete with 2.5 Sqmm (Nominal area) PVC insulated multistranded fire retardant low smoke unsheated and stranded copper conductor cable ISI marked in and including PVC concealed conduit medium quality and conduit fitting for 3 pin 15 amp multicore switch socket combination including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connected to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified and directed by Engineer-in-Charge.
S&F for switch Piano type single pole one way 5 Amp,230 VAC supply complete all as specified and directed by Engineer-in-Charge.
S&F for socket two in one ,3 Pin 5 Amps 230 VAC supply complete all as specified and directed by Engineer-in-Charge.
S&F for switch Piano type single pole one way 15 Amp on laminated sheet top cover complete all as specified and directed by Engineer-in-Charge. Note : Sheet top cover including in point wiring.
S&F for socket 6 Pin 16 amp,230 VAC complete all as specified and directed by Engineer-in-Charge.
M&L for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F for Exhaust fan heavy duty 300mm sweep mounted in suitable opening arrangement with louvers shutters suitable for operation on 230 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheated copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and fixed by using 4 Nos. 200mm long 12mm dia bolts, nuts and washers and grouted in wall in CM 1:3 complete all as specified and directed by Engineer-in-Charge.
S&F for Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting TPN 4 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed by Engineer-in-Charge.
S & F for MCCB TPN , 415 volts AC 100 Amps, with over load and short circuit protection and rupturing capacity not less than 16 KA complete all as specified and directed by Engineer-in-Charge.
S & F for MCB SP 240 volts AC of rating 63 Amps with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F for Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 12 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed by Engineer-in-Charge.
S & F for MCB SP 240 volts AC of rating 40 Amp, 10 KA complete all as specified and directed by Engineer-in-Charge.
S & F for MCB SPN 240 volts AC of rating 40 Amp, 10 KA complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth platge electroe 60 cmx60cm6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal round level) with edge of the plae not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and GI washers earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around bottom and top of earth plate as shown in electrical piate No. 3 of SSR Part-I and connecting to earthing test point and testing on completion including PCC 1:3:6 type C2 for earthing pit, GI light grade protection pipe of size 15mm dia, watering pipe 20mm bore medium grade, CI cover and frame necessary earth works and PCC work etc complete all as specified. Earth plate shall be surrounded by alternate layer of charcoal of coke and common salt 15cm thick alround the earth plate including bottom and top complete all as specified and directed by Engineer-in-Charge. Note: PCC chamber shall be constructed at least 1.5mtr away from the earth electrod and pipe for watering shall be slanting manner
S&F for LED tube light fixture,environmental friendly energy efficient ready to use 18W LED 6000k(4') complete with with all electrical connection complete all as specified and directed by Engineer-in-Charge.
S&F for Batten for LED tube light fixture with extruded aluminium heat sink,environmental friendly energy efficient ready to use with 18W LED 6000K(4') including electric connection with PVC copper flexible twin core cable,1.0 Sqmm from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
M & L for Sub main wiring with 2 single core 6 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn into and including PVC conduit rigid non metallic of suitable dia with and including independent PVC insulated one run 6 Sqmm single core copper earth wire complete all as specified and directed by Engineer-in-Charge. Note:- Three lengths of 6 sqmm cable and will be measured as one length
M&L for LED 10W bulkhead fitting with IP-65 engineering housing with clear, single phase 240V, including 1.0sqmm copper flexible cable twiested three core alongwith flelxible PVC condiut from ceiling rose to fitting testing complete all as specified and directed by Engineer-in-Charge.
Taking down carefully existing Geyser of any capacity and make complete with fitting such as Earth plug socket, GI Pipes, PTMT Nuts, and making good to the disturbed surfaces of walls, matching the colour with existing Surface complete all as specified and directed by Engineer-in-Charge. Note: Rate for making good shall be deemed to be included in above item rate.
Supply and fixing for storage type water heater electric driven of capacity 50 ltr having minimum 3 star rating incl grouting of nut and bolt suitable size including cement work complete all as specified and directed by Engineer-in-Charge.
S & F for sheet metal enclousre single pole and neutral with a two pin and earth plug and socket complete with one single MCB 20 amp complete all as specified and directed by Engineer-in-Charge.
Supply and fix stop valves fancy type (CP) cast copper alloy screwed down with high pressure with crunch screwed both ends for pipe and union etc of size 15 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix bib tap fancy type (CP) cast copper alloy screwed down with high pressure with crunch screwed both ends for pipe or brass ferrule etc of size 15 mm dia complete all as specified and directed by Engineer-in-Charge.
M & L for galvanised tube mediem garde 15 mm dia with all fitting and fixed complete to walls and ceilings or laid in floors including clamp complete all as specified and directed by Engineer-in-Charge.
S & F PVC connection pipe for geyser of dia 15 mm with PTMT nuts of lengths 450 mm suitable for hot water complete all as specified and directed by Engineer-in-Charge. --------------------------------------------------------------------------------------------------- Note : A sum of Rs. 41,990.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 33 & 34 (Schedule of Credit) of Tender document
S.S.ENGINEERS AND CONSTRUCTION CO.
M/S RAJESH KUMAR and CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .