Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | ₹44.8 L | L1 | Accepted-AOC Accept |
| 2 | L2₹50.0 LRejected-Finance | ₹50.0 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹50.1 LRejected-Finance SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹50.1 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹50.6 LRejected-Finance | ₹50.6 L | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹51.5 LRejected-Finance | ₹51.5 L | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | PTech Engineers L1 | M/s Karbhagam Sales Agency L5 | A. R. ELECTRICALS L3 | M/s Pooja Enterprises L2 | Kathir Marketing Services L7 | SKV Engineering L6 | RS ENGINEERING WORK L8 | Blue chip consultancy Service L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F in replacement Low oil pressure transducer of 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set system complete all as specified and directed. | 4 | Job | 1,750 ₹7,000 | 2,182 ₹8,728 | 2,051 ₹8,204 | 2,180 ₹8,720 | 2,440 ₹9,760 | 2,700 ₹10,800 | 2,800 ₹11,200 | 2,000 ₹8,000 |
| 2.00 | S&F in replacement Low lubricant oil pressure safety suitable for 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set system all as specified and directed. | 3 | Job | 7,250 ₹21,750 | 9,045 ₹27,135 | 9,250 ₹27,750 | 9,000 ₹27,000 | 9,235 ₹27,705 | 10,100 ₹30,300 | 10,500 ₹31,500 | 8,500 ₹25,500 |
| 3.00 | S&F in replacement High water temperature trip safety suitable for 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set system complete all as specified and directed. | 2 | Job | 8,770 ₹17,540 | 9,555 ₹19,110 | 10,450 ₹20,900 | 9,500 ₹19,000 | 9,990 ₹19,980 | 10,500 ₹21,000 | 10,600 ₹21,200 | 10,550 ₹21,100 |
| 4.00 | S&F in replacement harness wiring of safety suitable for 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set operating system complete all as specified and directed. | 3 | Job | 1,750 ₹5,250 | 1,740 ₹5,220 | 1,850 ₹5,550 | 1,700 ₹5,100 | 2,100 ₹6,300 | 2,000 ₹6,000 | 2,100 ₹6,300 | 1,900 ₹5,700 |
| 5.00 | S&F in replacement shutdown valve/ FIP solenoid switch suitable for 62.5 to 320 KVA DG set as per existing make and model complete all as specified and directed. | 2 | Job | 6,100 ₹12,200 | 7,790 ₹15,580 | 7,500 ₹15,000 | 7,750 ₹15,500 | 8,650 ₹17,300 | 8,500 ₹17,000 | 8,700 ₹17,400 | 7,950 ₹15,900 |
| 6.00 | S&F in replacement of magnetic pick up of 62.5 to 320 KVA DG set as per existing make and model complete all as specified and directed. | 3 | Job | 5,750 ₹17,250 | 7,000 ₹21,000 | 7,100 ₹21,300 | 6,950 ₹20,850 | 7,980 ₹23,940 | 7,100 ₹21,300 | 7,200 ₹21,600 | 7,000 ₹21,000 |
| 7.00 | S&F in replacement of AVR unit as per existing make and model and suitable for DG set 63 / 82.5 /100/ 125 KVA incl connecting with alternator and control panel circuits, starting and testing complete all as specified and directed. | 2 | Job | 13,885 ₹27,770 | 13,955 ₹27,910 | 14,210 ₹28,420 | 14,000 ₹28,000 | 14,890 ₹29,780 | 14,230 ₹28,460 | 14,300 ₹28,600 | 14,330 ₹28,660 |
| 8.00 | S&F in replacement of AVR unit as per existing make and model and suitable for DG set 160 / 200/250/320 KVA incl connecting with alternator and control panel circuits, starting and testing complete all as specified and directed. | 2 | Job | 14,000 ₹28,000 | 16,000 ₹32,000 | 16,000 ₹32,000 | 15,500 ₹31,000 | 16,325 ₹32,650 | 16,240 ₹32,480 | 16,300 ₹32,600 | 15,950 ₹31,900 |
| 9.00 | S&F in replacement rotating rectifier diodes as per existing make and model and suitable for DG set 125/160 / 200 /250/320KVA complete all as specified and directed. | 2 | Job | 14,230 ₹28,460 | 15,187 ₹30,374 | 15,100 ₹30,200 | 15,100 ₹30,200 | 15,790 ₹31,580 | 15,990 ₹31,980 | 16,000 ₹32,000 | 15,345 ₹30,690 |
| 10.00 | S&F in replacement rotating rectifier diodes as per existing make and model suitable for Cummins DG set 25/62.5/82.5/100 KVA complete all as directed at site. | 2 | Job | 12,500 ₹25,000 | 13,340 ₹26,680 | 13,350 ₹26,700 | 13,000 ₹26,000 | 13,990 ₹27,980 | 14,230 ₹28,460 | 14,500 ₹29,000 | 13,150 ₹26,300 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Mar 2026, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
REPAIR / MAINT AND CLEANING OF DG SET, DIESEL DRIVEN ENGINES, BOOM BARRIERS, HANGER MOTORS, AMF PANELS AND CONNECTED WORKS AT VAYU VIHAR AND BROOKSHABAD UNDER AGE EM-II OF GE MINNIE BAY, SRI VIJAYA PURAM
2026_MES_751877_1
8708/E8
Open Tender
Civil Works
270 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
13 documents required · 13 mandatory
₹500
Yes
GE, Minniebay
₹90,000
Yes
8 Apr 2026
9 Feb 2026
4 Mar 2026
9 Feb 2026
2 Mar 2026
23 Feb 2026
S&F in replacement Low oil pressure transducer of 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set system complete all as specified and directed.
S&F in replacement Low lubricant oil pressure safety suitable for 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set system all as specified and directed.
S&F in replacement High water temperature trip safety suitable for 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set system complete all as specified and directed.
S&F in replacement harness wiring suitable for 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set operating system complete all as specified and directed.
S&F in replacement shutdown valve suitable for 62.5 to 320 KVA DG set as per existing make and model complete all as specified and directed.
S&F in replacement of magnetic pick up of 62.5 to 320 KVA DG set as per existing make and model complete all as specified and directed.
S&F in replacement of AVR unit as per existing make and model and suitable for DG set 63 / 82.5 /100/ 125 KVA incl connecting with alternator and control panel circuits, starting and testing complete all as specified and directed.
S&F in replacement of AVR unit as per existing make and model and suitable for DG set 160 / 200/250/320 KVA incl connecting with alternator and control panel circuits, starting and testing complete all as specified and directed.
S&F in replacement rotating rectifier assembly as per existing make and model and suitable for DG set 125/160 / 200 /250/320KVA complete all as specified and directed.
S&F in replacement rotating rectifier assembly as per existing make and model suitable for Cummins DG set 25/62.5/82.5/100 KVA complete all as directed at site.
M & L for B check (Every 300 hours/06 months) as per maintenance schedule of Diesel Engines set of capacity 25 KVA for Kirloskar / Cummins / Cotton greaves / as per OEM including changing of lub oil , oil & fuel filters,Fuel sup sys,Cooling sys, Air Sys, Lubrication sys and other maintenance check vibration,Check Air Filtter etc all as specified by the manufacturer and as directed by the Engr-in-Charge Note : Engine oil & Coolant shall be measured and paid separately under relevent item of this schedule.
All as per item No 11 above but for DG set of capacity 62.5 KVA
All as per item No 11 above but for DG set of capacity 82.5KVA
All as per item No 11 above but for DG set of capacity 100KVA
All as per item No 11 above but for DG set of capacity 125 KVA
All as per item No 11 above but for DG set of capacity 160 KVA
All as per item No 11 above but for DG set of capacity 200 KVA
All as per item No 11 above but for DG set of capacity 250 KVA
All as per item No 11 above but for DG set of capacity 320 KVA
M & L for B check maintenance of 156 HP drainage pump for Kirloskar / as per OEM including changing of lub oil , oil & fuel filters all as specified by the manufacturer and as directed by the Engr-in-Charge Note : Engine oil shall be measured and paid separately under relevent item of this schedule
M & L for repair and reconditioning of battery charge alternator 24 V DC for Cummins / as per OEM including taking out the defective alternator from 100/125 / 160 KVA / 200 KVA/250/320 capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge
M & L for repair and reconditioning of battery charge alternator 12 V DC cummins make including taking out the defective alternator from 25 / 62.5 KVA / 82.5 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge
Supply only coolant for radiator suitable for DG set of capcity 25/62.5 / 100/ 125 / 160/200/250/ 320 KVA of Make- Cummins/ Cotton greave/ Kirloskar under cat part no 3167215 all as per manufacturers recommendations and directed by Engr-in-Charge
Supply only engine oil suitable grade SAE-20W40 complete all as specified and directed.
M & L for fixing in replacement of asbestos rope 12 mm dia for wrapping the exhaust pipe of DG set all as directed by Engineer-in-charge.
M & L for fixing in replacement of Air filter of 25/62.5/100/125 KVA DG set of make Cummins/ Cotton greave/ Kirloskar all as specified and directed by Engineer-in-charge.
M & L for fixing in replacement of Air filter of 160 / 200/250 / 320 KVA DG set of make Cummins / Cotton greave/ Kirloskar all as specified and directed by Engineer-in-charge.
M & L for fixing in replacement water pump of 100/125/160 / 200/320/250 DG set of make Cummins/ Cotton greave/ Kirloskar all as specified and directed by Engineer-in-charge
M & L for fixing in replacement replacement of water pump of 25/ 62.5/82.5 KVA DG set of make Cummins/ Cotton greave/ Kirloskar all as specified and directed by Engineer-in-charge.
M & L fixing in replacement of fan belt ( each set ) in 25/62.5/82.5/100 / 125 KVA DG set of make Cummins/ Cotton greave/ Kirloskar all as specified and directed by Engineer-in-charge
M & L for fixing in replacement of fan belt ( each set ) in 160/ 200/ 250 /320 KVA / DG set of Make- Cummins/ Cotton greave/ Kirloskar all as specified and directed by Engineer-in-charge
M & L for fixing in replacement of belt water pump (each set) in 25/62.5/82.5/100/125 KVA DG set of Make- Cummins/ Cotton greave/ Kirloskar all as specified and directed by Engineer-in-charge
M & L for fixing in replacement of belt water pump (each set) in 160/200/250/320 KVA DG set of Make- Cummins/ Cotton greave/ Kirloskar all as specified and directed by Engineer-in-charge
M & L for repair and reconditioning the starting motor of Kirloskar / Cummins / Greaves as per make / model at site including taking out the defective starter from 160 KVA / 200 KVA /250/320KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assly, bush, commutator unit, stator running coil unit , stator starting coil etc and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge . Note : Supply only of spare parts shall be measured ana paid separately under relevent item of this Schedule
Supply and Fixing in replacement of Carbon brush set with holder as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed .
Supply and fixing in replacement of Solenoid switch assembly with bush as per existing make and model suitable for160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed .
Supply and fixing in replacement of commutator unit as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed .
Supply and fixing in replacement of stator starting coil unit as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed .
Supply and fixing in replacement of stator running coil unit as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed .
M & L for repair and reconditioning the starting motor 12 V DC of kirloskar / Cummins / Greaves make including taking out the defective starter from 25/62.5/82.5/100/125 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assly, bush, commutator unit, starting starting coil, stator running coil etc and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge. Note : Supply only of spare parts shall be measured ana paid separately under relevent item of this Schedule
Supply only carbon brush set with holder as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed .
Supply only Solenoid switch assembly with bush as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed .
Supply only commutator unit as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed .
Supply only stator starting coil unit complete as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed .
Supply only stator running coil unit as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed .
M&L for repairs of copper / aluminium type radiator of capacity 25/62.5/82.5/100/125 KVA DG Sets ,taking out by disconnecting from DG set and locating the leaking places and soldering / brazing complete with cleaning by acid and refixing in position including replacement of old hose pipe with new complete all as specified and directed at site. Note : Supply only of oil hose shall be measured and paid separately under relevent item of this schedule
M&L for repairs of copper / aluminium type radiator of capacity 160 KVA / 200 KVA /250/320KVA DG Sets ,taking out by disconnecting from DG set and locating the leaking places and soldering / brazing complete with cleaning by acid and refixing in position including replacement of old hose pipe with new complete all as specified and directed at site. Note : Supply only of oil hose shall be measured and paid separately under relevent item of this schedule
Supply and Fix inreplacement of Lub oil hoses set complete for DG set of capacity 125/160/200 KVA complete all as directed
Supply and fix in replacement Lub oil hoses set complete for DG set of capacity 25/62.5/82.5 KVA complete all as directed.
S&F in replacement of 3 pole ML- 4 Contactor, heavy duty with aux contacts 415 Volt all as per existing make and model complete all as specified and directed.
S&F in replacement 4 pole MCX 32 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 62.5 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed by Engineer-in-charge
S&F in replacement 4 pole MCX 41 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 125 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed by Engineer-in-charge
S&F in replacement 4 pole MCX 33 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 200 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed by Engineer-in-charge
S&F in replacement 4 pole MNX 45 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 200 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed by Engineer-in-charge
S&F in replacement of 220 / 415 Volt Coil suitable for ML- 4 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement of 215 / 415 Volt Coil suitable for MNX 325 / MCX 32 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement of 220/415 Volt Coil suitable for MCX-41 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement of 220/415 Volt Coil suitable for MCX-33 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement of 220/415 Volt Coil suitable for MNX 45 Contactor as per existing make and model complete all as specified and directed.
M&L for taking down stator assembly of alternator 25 KVA to 320 kva DG Sets by disconnecting electrically and mechanically complete cleaning with CTC and decarbonising the stator , rotor and excitor coils, heating the coils for achieving insulation upto the mark, checking thoroughly the complete system and connections and replacing the defective insulation paper by applying Dr Beck varnish baking / heating and bringing back to installation and refixing and assembling the same Connecting electrically , mechanically and testing on completion of work complete all as directed at site.
M&L for taking down stator assembly of alternator 160/200/250/320 KVA DG Sets by disconnecting electrically and mechanically complete cleaning with CTC and decarbonising the stator , rotor and excitor coils, heating the coils for achieving insulation upto the mark, checking thoroughly the complete system and connections and replacing the defective insulation paper by applying Dr Beck varnish baking / heating and bringing back to installation and refixing and assembling the same Connecting electrically , mechanically and testing on completion of work complete all as directed at site.
S&F in replacement of maintenance free lead acid battery 12 Volt,180AH capacity complete with brass terminals including testing on load complete all as specified and directed
S&F in replacement maintenance free lead acid battery 12 volt 150 AH capacity all complete with brass terminals including testing on load complete all as specified and directed
S&F in replacement maintenance free lead acid battery 12 volt 130 AH capacity complete with brass terminals including testing on load complete all as specified and directed
Supply and fill distilled water for batteries 12 volt 180 / 150 AH / 130 AH all as specified and directed by Engr-in-Charge.
S&F in replacement of Automatic battery charging unit with indication of automatic charge, float with charge indication and cut off 220 V input AC and output 12/24 V DC, 10 Amps and testing with DG sets complete all as specified and direceted.
S&F in replacment of alternator terminal connector in 62.5 to 320 KVA by taking out the burnt connector from alternator, checking cable lugs including testing complete all as specified and directed at site.
S&F in replacement of PT fuel pump by dismantling, transporting, repairing and calibration, testing and commissioning of PT fuel pump for 160 / 200 KVA/250/320KVA DG set including the replacement of all service kits, pulsvation damper, tacho drive shaft and seal, gear drive shaft , bearing, weight carriers, etc all as specified and directed by Engineer-in-charge
S&F in replacement of PT fuel pump by dismantling, transporting, repairing and calibration, testing and commissioning of PT fuel pump for 25/62.5/82.5/100/125 KVA DG set including the replacement of all service kits, pulsvation damper, tacho drive shaft and seal, gear drive shaft , bearing, weight carriers, etc all as specified and directed by Engineer-in-charge
M&L for for taking down stator assembly of alternator of DG set of capacity 25/62.5/82.5/100/ 125 KVA by disconnecting electrically and mechanically taking to work shop for rewinding incl removing burnt coils, insulating material complete cleaning with CTC and rewinding with same gauge ISI marked winding wire complete with ISI marked insulating paper and Dr Beck varnish baking / heating and bringing back to installation refixing , connecting electrically and mechanically and testing on completion of work complete all as specified and directed.
All as per item No 70 above but alternator for DG set of capacity 160/ 200 KVA/250/320KVA
S&F in replacement and commissioning 24 V DC heavy duty starter motor as per existing make and model suitable for 160 / 200/250 KVA Cummins / Kirloskar DG set all as directed by Engineer-in-Charge
S&F in replacement and commissioning 12 V DC heavy duty self starter motor as per existing make and model suitable for 125/82.5/ 62.5 KVA Cummins / Kirloskar DG set all as directed by Engineer-in-Charge
M&L for fixing in replacement of DG Set door Hinges & accessaries for 25 to 320KVA DG Sets complete all as directed
M&L for fixing in replacement of DG Set door Hinges & accessaries for 160/ 200 / 250/320 KVA DG Sets complete all as directed
S&F in replacement DG set control panel into Digital electronic control panel with mounting bracket with vibration isolating pads -3 nos of 25 to 320 KVA DG Sets as per existing make and model complete all as directed.
S&F in replacement DG set control panel into Digital electronic control panel with mounting bracket with vibration isolating pads -3 nos of 25/62.5/82.5/100/125KVA DG Sets as per existing make and model complete all as directed at Site.
S&F in replacement of Push button ( 2 nos ) as per existing make and model for ON / Off 25 to 320 KVA AMF panel connecting with control circuit including connection and testing complete all as specified and directed
S & F in replacement Electronic Governor controller under Cummins in 25/62.5/82.5/125/160/200/250/320 KVA DG set and testing all as specified and dicrected by Engineer-in-charge
Supply, installation and commissioning of radiator for 200/250/320 KVA Cummins DG set under Cummins including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed by Engineer-in-Charge.
M & L for supply, installation and commissioning of radiator for 160 KVA/100/125 KVA Cummins DG set under Cummins including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed by Engineer-in-Charge.
M & L for supply, installation and commissioning of radiator for 25/62.5/82.5 KVA Cummins DG set under Cummins including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed by Engineer-in-Charge.
S&F in replacement of AMF Logic conttroller (Microprocessor based type) by taking out the defective unit from 25 / 62.5/ 82.5/100/125 KVA capacity DG set as per existing make and model complete checking the panel and its connection circuit in the panel board, providing prper interlink connection with DG set including all required items, starting and testing all as specified and directed by Engineer-in-charge.
All as per item No 85 above but 160/ 200/250/320 KVA DG sets.
S&F in replacement start and stop relay 12 V/24 V DC suitable for AMF Panel capacity of 25 to 320 KVA all as specified and directed.
S & F in replacement of high bay light 150 W luminaries with high power (integral) with system lumen out put 220 volts,50 Hz, with suitable capacity drives in side housing complete all as specified and directed
S & F in replacement of heavy duty Exhaust fan 600mm Sweep 240 volt , Opal White / brown including bracket nut bolts , and making hole for fitting fan on wall including all accessories complete all as specified and as directed
S&F in replacement of wall mounted fan (Air cerculators) Turbo Force 600mm sweep compplete all as specified and as directed
Dismantling iron sections as in chequred plate and frame work to plates in any size and position all as specified and directed.
S&F Mild steel plates (plain or chequred) plate channels squre cut or notched forming holes , without any attachement incl necessary welding as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide, Zinc chrome primer on steel surfaces of any descrption , over 10cm width or girth, including preparing on new steel surfaces complete all as specified and directed.
M&L for writing MES NO of DG set in white / black colour, minimum 15 letters complete all as specified and directed by Engineer -in - Charge Note : Min of 15 letters shall be considered as one job
M&L for cleaning of fuel tank made of MS sheet up to 320KVA DG Sets by draining out fuel in a separate container, taking out all silt / dirt deposition inside the tank, cleaning it completely by manual and necessary T&P and refitting and connecting with fuel pipes complete all as specified and as directed
S&F of battery lead with stranded copper conductor of size 70 sqmm single core PVC insulated flexible 0.6 M long along with battery terminal for positive and stator terminal duly soldered all as directed.
S&F in replacement of battery lead with stranded copper conductor of size 70 sqmm single core PVC insulated flexible 0.6M long along with battery terminal for negative and stator terminal duly soldered all as directed.
S&F in replacement of sheet metal enclosure with socket plug top , five pin and neutral enclosure with three pin earth plug and socket complete with one MCB TPN of capacity 32 Amps complete all as specified and directed by Engr-in-Charge.
Supply only Rubber insulation Mat 1mx2mx10mm for 62.5/82.5/100 KVA DG Sets for protection same shape and size all as specified and directed by engr-in-charge.
Supply only Rubber insulation Mat 1mx2mx19mm for 125/160/200/250/320 KVA DG Sets for protection same shape and size all as specified and directed by engr-in-charge.
S&F for Submersible water proof cable 3 core 35 Sqmm copper cable flat type complete all as specified and as directed.
S&F in replacement cable PVC insulated sheathed, unarmoured, round water proof with stranded copper conductor 1100 V grade of size 4 core 10 Sq mm for hanger motor up to 25 Mtr height and necessary clamp to move the round cable all as directed at site.
S&F in replacement cable PVC insulated sheathed, unarmoured, round water proof with stranded copper conductor 1100 V grade of size 4 core 16 Sq mm for hanger motor up to 25 Mtr height and necessary clamp to move the round cable all as directed at site.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 100 Amps.as per existing make and model complete all as directed.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 125 Amps. as per existing make and model complete all as directed.
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 160 Amps as per existing make and model complete all as directed.
M&L for disconnecting electrically and mechanically induction electric motor from hanger door of capacity of 5 HP electrically operated three phase 415 volt, opening gear box assembly for inspection and servicing of gearbox assembly with steel truck channel , cleaning the slots and greasing , oiling the gear box assembly complete all as directed.
M&L for disconnecting electrically and mechanically defective induction electric motor from hanger door of capacity of 5 HP electrically operated three phase 415 volt, shifting to civil workshop for repair, strip opening for inspection, cutting of unserviceable burnt winding, taking out, cleaning of slots, rewinding with new super enameled ,copper conductor winding wire and replacement of u/s burnt insulating materials, sleeves etc,varnishing and other connected works,re-assembling,re-fixing at site, electrical connection fixing with pump set with nuts,bolts,washers as per original position and testing complete all as directed by the Engineer-in- Charge at site
M&L for disconnecting electrically and mechanically defective gear box assembly from hanger motor of capacity of 5 HP electrically operated three phase 415 volt,shifting to civil workshop for repair,strip opening for inspection, taking out unserviceable bearing, cleaning of slots, and replacement u/s gear pinion, back axile and filling with gear oil ,re-assembling,re-fixing at site as per original position and testing complete all as directed by the Engineer-in- Charge at site
S&F in replacement on load change over switch 415 V, 4 pole,200 A open execution as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement on load change over switch 415 V, 4 pole, 250 A open execution as per existing make and model suitable equivalent make as per list of make at PScomplete all as specified and directed.
S&F in replacement on load change over switch 415 V, 4 pole, 320 A open execution as per existing make and model suitable equivalent make as per list of make at PScomplete all as specified and directed.
S&F in replacement on load change over switch 415 V, 4 pole, 400 A open execution as per existing make and model suitable equivalent make as per list of make at PScomplete all as specified and directed.
Supply only Electric pump 1HP Single Phase for fuel filling tank complete all as specified and directed.
Taking out and serviceing automatic electrically operated boom barrier complete assembly cleaning,gressing oiling,de-carbonising of all parts barrier box , automatic barrier gates,straight arm folding/fencing type,traffic mirror, nurse call bell system,photo sensor,control card and boom rest stand in workshop, refitting including replacement all connected accessories complete testing all as specified and directed. Note : (i) The cost of cleaning materials like kerocine oil, cotton waste etc. and lubricating item like mobile oil, greese etc. required for this job are deemed inclusive in the rates. (ii) All parts of barrier box , automatic barrier gates,straight arm folding/fencing type,traffic mirror, nurse call bell system,photo sensor control card and boom rest stand are to be measured and paid separately in the relevant item of this schedule as " Supply only" Items below.
Supply and Fixing boom rest stand as per same shape and size all as specified and directed by Engr-in-charge.
Supply and Fixing photo sensor control card as per same shape and size complete all as specified and directed by Engr-in-charge.
Supply and fixing nurse call bell set as per same shape and size complete all as specified and directed by Engr-in-charge.
Supply only automatic barrier gates,straight arm as per same shape and size complete all as specified and directed by Engr-in-charge.
Earthing complete with copper earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper wire 4.0mm dia by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No. 3 connected to earthing test point all as specified 20×3mm copper strip as earthing lead
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
technical_842118.pdf
techsummary_842118.pdf
finance_842118.pdf
BOQ Comparative Chart
xlsx
finsummary_842118.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_842118.xls
BOQ • 0.33 MB
8708TENDER.pdf
Tender Documents • 0.89 MB
Download all tender documents and submit your bid