Loading…
Loading…
Tender Value
₹29.1 Cr
EMD Value
₹58.2 L
Closing Date
10 Jul 2026, 11:00 am
Hubballi Division: BAY - RDG section: Provision of Two additional loop lines with R&D facilities along with associated Civil, Track, Signal, TRD and Electrical (Genl) works at Obulapuram station (Phase II) (Composite tender).
H-GS-UBL-03-2026-27
H-GS-UBL-03-2026-27
Open
18 Months
Anantapur, Andhra Pradesh
₹0
₹58.2 L
16 Jun 2026
16 Jun 2026
26 Jun 2026
D-Concrete and other Bridge Items 19755958.48 Below/P
E-Supply of Reinforcement steel 26803744.80 Below/P
H-Collection and Supply of Ballast 6391554.40 Below/P
Item Breakup - A-DSR Items Civil
Item Breakup - B-Earth Work
Preparation Embankment by clearing, grubbing, stripping top soil (average 150 mm) and stacking beyond foundation area, thereafter ploughing and pulverizing 150 - 200 mm of top of soil with tractor trolley, mixing water to achieve OMC with water sprinkler or left for natural drying, as required, and compaction with vibratory roller of suitable capacity to achieve 98% MDD for laying first layer of soil for embankment construction.
Foundation preparation in cutting - 100 Sqm ploughing and pulverizing 15 cm of top of soil with tractor trolley, mixing water to achieve OMC with water sprinkler or allowing for natural drying, as required, and compaction with vibratory roller of suitable capacity to achieve 98% MDD for laying blanketing layer. Turfing / planting, including all lead & lift and watering as required until properly rooted with. Note: Initially payment of only 40% will be made. Balance 60% will be paid after 3 months of maintenance period, only if the turfing is properly rooted on entire turfed area. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Turfing with sods, 10cm thick and 100 Sqm 20cm square closely laid. Provision of barricading with contractor's bamboos / ballies vertical post of 100mm dia. planted at every 2m interval, projecting at least 1.5m above ground level and driven firmly (minimum 0.5m) inside ground and including painting verticals & horizontals with red luminous paints / strips at alternative bay on barricade. Barricades shall be maintained through out the execution of the w o r k and shall be removed in workman like manner on completion of the work only after instruction of Engineer in-Charge. Note: (1) 60% payment shall be made on provision of barricading at work-site and balance 40% payment after removal of barricades. (2) The released bamboos / ballies shall be the property of the Contractor.
With 3 horizontal bamboo / balli RM members of minimum 50mm dia. spaced equally
Shoring with 'Z' section MS sheet Sqm piles side by side in all kinds of soil mechanically or manually as per approved drawing with contractor's own arrangement complete in all respects and removal of sheet piles after completion of the work as directed by engineer in-charge Note: Payment will be made as per actual driven length of pile. Total 282671.71
Item Breakup - C-Supply of Cement
Ordinary Portland Cement 43 grade MT approved brands/makes Total 7326695.21
Item Breakup - D-Concrete and other Bridge Items
0m to 10m HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY Exploratory drilling of Boreholes down to required depth, drilling of 150mm diameter boreholes in all type of soils except hard rock and large boulders (boulder core more than 30cm), including refilling, reinstating surface and disposing off surplus material including use of mechanical rigs with power operated winches as well as percussion / chiselling tool for advancing through occasional seams of hard strata to be employed where necessary in River bed area including standing/flowing w a t e r with all necessary arrangements except making of platform under water which shall be paid under relevant item of SOR.
Extra for 150mm dia. bore in hard Metre Rock/large Boulder at all levels Drilling of NX size borehole (75mm dia.) in all types of hard rock and collection of rock core samples from boreholes and preserving in boxes.
Taking out 100mm dia. & 450mm Each long undisturbed samples of soil from bore holes, including provision of air tight containers for packing and, labeling incl. transporting the samples to laboratory. Piston sampler shall be used for extracting undisturbed samples where necessary. Samples shall be collected as per IS:2720.
Taking out 100mm dia. & 450mm Each long disturbed samples of soil from bore holes, including provision of air tight containers for packing, labeling and transporting the samples to laboratory. Samples shall be collected as per IS:2720.
Conducting standard penetration Each test as per IS:2131 at approximate1.5m intervals in bore holes, as directed by the Engineer in charge Conducting laboratory Tests on collected soil samples as per relevant IS code
Moisture Content/Dry Density
Atterberg Limits
Specific Gravity
Grain Hydrometer analysis
Direct Shear Test
Natural Density
Consolidation Test
Unconfined Compression Test
Tri-axial Test Conducting Laboratory tests on collected ROCK SAMPLES as per relevant IS code HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Water Absorption & Porosity
Unconfined Compression Test Earthwork in excavation by mechanical means (Hydraulic Excavator)/Manual Means for foundations and floors of the bridges, retaining walls etc. including setting out, dressing of sides, ramming of bottom, getting out the excavated material, back filling in layers with approved material and consolidation of the layers by ramming and watering etc. including all lift, disposal of surplus soil up to a lead of 300m, all types of shoring and strutting with all labour and material complete as per drawing and technical specification as directed by Engineer in charge. Note: This item will be used for excavation work in connection with other miscellaneous works also like side drains, foundation for OHE masts and other miscellaneous structures in connection with Gauge Conversion, Doubling, New lines.
All kinds of soils
Soft rock (not requiring blasting)
Hard rock (blasting prohibited ) Providing and laying in position Plain cement concrete of specified Nominal Mix f o r miscellaneous works like side drains, foundation for OHE masts and other miscellaneous structures excluding the cost of Cement, centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement : 3 coarse sand cum (zone-III) : 6 graded stone aggregate 20 mm nominal size) HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY Providing and laying in position machine batched, machine mixed and machine vibrated Cement Concrete of specified grade as per approved Design Mix (mixed in Mobile Concrete Batching/Mixing Plant at site or RMC from approved plants) using 20mm graded crushed stone aggregate and coarse sand of approved quality for the following Reinforced cement concrete structural elements up to height of 9.0 m from foundation top level, including finishing, using Plasticiser in approved proportions (as per IS:9103), to modify workability without impairing strength and durability complete as per specifications and direction of the Engineer in charge. N o t e : 1. Payment for cement, reinforcement and shuttering shall be made extra under relevant item. 2. Plasticiser shall invariably be used in approved proportion to increase workability with minimum possible quantity of cement for all grade of Design Mix Concrete unless it is specifically approved citing reasons for not using plasticiser at the stage of Mix Design and in that case deduction shall be made as per relevant item.
Abutment & Pier
Wing wall and Return wall
Abutment cap, Pier Cap, Inspection cum Platform & Pedestal over Pier cap, Fender wall, Diaphragm wall etc. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
P r o v i d i n g and casting machine cum batched, machine mixed and machine vibrated Cement Concrete of specified grade as per approved Design Mix, mixed in Mobile Concrete Batching/Mixing Plant at site or RMC from approved plants, (Cast in-Situ/Pre-cast) in bottom/top slab, side walls, toe wall and sumps haunch filling head walls, thrust bed or any other component using 20mm graded crushed stone aggregate and coarse sand of approved quality of RCC box of any size including finishing, Plasticiser in approved proportions (as per IS:9103), to modify workability without impairing strength and durability, complete as per drawings and technical specifications as directed by Engineer in charge. N o t e : 1. Payment for cement, reinforcement and shuttering shall be made extra under relevant item. 2. Plasticiser shall invariably be used in approved proportion to increase workability with minimum possible quantity of cement for all grade of Design Mix Concrete unless it is specifically approved citing reasons at the stage of Mix Design and in that case deduction shall be made as per relevant item.
Providing and laying in position cum machine batched, machine mixed and machine vibrated Design Mix Cement Concrete, mixed in Mobile Concrete Batching/Mixing Plant at site or RMC from approved plants, of specified grade (cast in-situ) using 20mm graded crushed stone aggregate and coarse sand of approved quality in Drop and curtain wall and alike structures below bed level, complete in all respect as per drawings and technical specifications to the satisfaction of Engineer-in-Charge. Note: Payment for cement, reinforcement and shuttering shall be made extra. Centering and shuttering including strutting, propping etc. and removal of form for :
All types of bridge sub-structures, Sqm e.g. pier, abutment, wing wall, retaining wall, RCC box type foundations, Abutment cap, Pier Cap, Inspection Platform & Pedestal over Pier cap, Fender wall, Diaphragm wall etc. up to 5m above ground level
All types of bridge super-structures, Sqm e.g. slabs, I-girders, T-girders, Box girders etc. up to 5m above ground level. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Providing, fabricating & fixing in MT position to exact design profiles, H.T.S. cables of all classification made from Low Relaxation strands conforming to IS:14268- latest version in Prestressed (Post- tensioned) Concrete girders/slabs etc. including supplying, cutting, making into cables with necessary spacers, colour coding, protecting with water soluble oil at all time, anchoring of cables, supplying and placing spiral corrugated type galvanized metal steel ducts sheathing made up of Cold Rolled Cold Annealed (CRCA) mild steel conforming to IS:513 of required diameter/ thickness, vent pipe, placing, bending, routing, fixing, stressing & grouting of cable ducts with cement grout, Anchorage sets in required number with provision for future prestressing if any including all lead and lift with contractor's own materials, labour, equipments etc. complete as per drawings & specifications. Rate also includes covering anchorage pads with epoxy mortar of approved quality to avoid corrosion. Cement for grouting to be paid separately. Payment shall be made in terms of weight of HTS cables as per drawing. Loading, transportation of Precast RCC Girders / Slabs / Ballast retainers / Steel Girders etc. from Casting Yard to Site of Work, unloading and stacking at site of work at prescribed location as directed by Engineer-in-Charge up to 60 kms.
Supplying weighing not less than 35 kg each at specified bridge locations.
Providing and laying Pitching with cum Stone Boulders, weighing not less than 35kg each with voids filled with cement sand mortar 1:4 on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical Specifications (filter media to be paid separately under the relevant item). Rate is excluding cost of cement which shall be paid extra under relevant item.
Providing and laying Filter Material cum as per RDSO Specifications underneath pitching in slopes complete as per drawing and Technical Specification. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Laying Boulder Apron on river bed cum for protection against scour with stone boulders supplied by Railway with voids filled with spalls complete as per drawings and Technical Specifications. Grouting of masonry/concrete by injection process duly Sealing of cracks, through nipples complete as per Technical Specification and procedure given in IRBM Para No 209 including necessary admixture. Payment shall be as per use of cement by weight in case of neat cement/cement mortar grouting and weight of Epoxy in case of Epoxy Grouting. (Cement will be paid extra).
Neat Cement Grout with 20% anti Kg shrinkage compound w.r.t. cement.
Providing weep holes by making Metre suitable opening or drilling in existing Brick Masonry / Plain / Reinforced Concrete abutment, wing wall/return wall with 110 mm dia UPVC pipe (working pressure 4kg/sqcm) extending through the full width of the structure complete and repairing the same with cement mortar 1:2 (1 cement : 2 coarse sand). Rate is excluding the cost of cement which shall be paid extra.
Providing cast in situ bridge number Each plaques as per Railway drawing in cement concrete 1:2:4 mix using 20mm hard stone aggregate embedded in 30mm notch in Bridge parapet coping duly engraving the letter and figures and an arrow indicating the direction of flow and finishing the top exposed surface with cement mortar 1:3, painting letters and figures with two coats of black enamel paint on two coats of white background with all labour, tools, cement, paint etc. with all leads and lifts. Providing & laying non pressure NP- 4 Class RCC pipe with collars, jointing with 1:2 cement and ordinary sand mortar including testing of joints, but excluding earthwork with all labour and material as a complete job. Cement for mortar will be paid separately. (Pipes of 600mm dia and above will be laid using crane/hydra).
300mm dia. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supplying, spreading and filling cum coarse sand (no cohesive materials to be used) of approved quality including watering and ramming in foundation, behind the abutment, wing wall, retaining wall in layers not exceeding 150mm thick including its compaction as per direction of Engineer-in-charge. The rate includes all lead, lift, ascent, descent, crossing of Railway line etc. complete with contractor's labour, materials, tools and plant.
Providing Boulder Backing behind cum wing wall, return wall, retaining wall with hand packed boulders & cobbles with smaller size boulders toward the back including all lead, lift, labour & other incidental charges as complete work in all respect. Payment for boulder/cobbles will be done extra.
Dewatering accumulated water from any location. Payment to be done for Horse power of pump multiplied by pumping hours. Total 19755958.48
Item Breakup - E-Supply of Reinforcement steel
Item Breakup - F-COE and blanketing Items
Using Soil Class SQ1
Using Soil Class SQ2 Earthwork in cutting in formation, trolley refuges, side drains, level crossing approaches, platforms, catch water drains, diversion of nallah & finishing to required dimension and slopes to obtain a neat appearance to standard profile inclusive of all labour, materials, plant & machinery, leading all cut spoils either to make spoil dumps or for filling in embankment with leads within 2 km on either side of edge of the cutting(s) including all lifts, ascent, descent, loading, unloading, bailing & pumping out water, if required, clearance of site and all other works incidental thereto for completing the work as per RDSO Specification No. RDSO/2020/GE: IRS-0004 with latest updated correction slips and to the satisfaction of the Engineer-in- Charge. Note: (i) All usable earth arising from cut spoils shall be led into bank formation and Unusable spoils shall be dumped / stacked away from toe of embankment. (ii) A l l hard rock /and boulders not fit for filling will be stacked by the contractor and will be property of the Railways. (iii)Cut trees shall be property of Railways and to be deposited in the railway godown unless specified otherwise in the Conditions of Contract.
In all conditions and classifications cum of soil except rock HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Soft rock not requiring blasting Total 17520854.00
Item Breakup - G-Superstructural steel
With Cement Grout. Cost of cement Kg shall be paid extra.
Supply & applying two coats of Sqm bitumen emulsion of Grade RS-1, conforming to IS:8887 on the top surface of concrete deck slab (New bridges) @ 1.70 kg/sqm after cleaning surface with all materials, labour, tools and plants, equipment etc. complete. Providing road crane of specified lifting capacity with specified jib length revolving type for material handling, assembly & erection of girders/slab/RCC Box etc.
250 MT capacity
Extra for increase in road crane Day capacity over Item 041209 for every additional 1 MT capacity or part there of Total 3467689.25
Item Breakup - H-Collection and Supply of Ballast
When distance of nearest quarry is cum more than 40 km and up to 50 km Total 6391554.40
Item Breakup - L-USSOR Track Items
Up to 40 m long rail panel Lubrication of fish plated rail joints under traffic, by using Grease Graphite Grade 'O' (IS:408) and Black oil supplied by contractor, for all types of rail sections as per procedure laid down in latest version of IRPWM and as directed by Engineer In charge. Note: Release U/S bolt & nuts is to be deposited back. If any fish bolts is jammed it should be cut with chisel and hammer and replaced with fresh fish bolt supplied.
For 1.00m long fishplates
Lubrication of Elastic Rail Clips on ERC PSC sleepers as per procedure prescribed in latest edition of IRPWM with Railway's grease. Gas cutting of rail of various sections with contractor's tools & plants, as directed by engineer in- charge :
Rail section of 52Kg and above Assembling and Laying of Improved Switch Expansion Joint (SEJ) on PSC sleepers of any rail section as per RDSO drawing including leading of SEJ rails, sleepers, fittings for a free lead of 250 metres, cutting of rails, drilling of holes as required and lubrication of SEJ, gauging, aligning rails, providing temporary connection with adequate welding gap with adjoining rails, providing reference posts at SEJ, first through packing of SEJ portion to make track geometry fit for 30 kmph speed and making ballast profile as per IRPWM. Note: (1) Rail cutting and hole drilling shall be paid separately.(2) One set comprise complete SEJ on both rails at SEJ.
Under Conditions Traffic Block HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY Assembling complete BG Turnout on staging, clear of infringements, to correct gauge and alignment as per standard drawings with all types of rail sections over PSC sleepers at specified locations, duly leading rails, special sleepers, switches, crossings with a maximum lead of 500m, all lift & crossing of track as required and testing points with S&T staff for throw of switch etc. at station yard after levelling surface complete including lubrication of all fastenings, complete in all respect. Note: 1.Rail cutting and Drilling shall be paid separately 2. Required P.Way fittings/fastenings shall be supplied at the SSE/P.Way stores.
1 in 12 Turnout Laying and linking of turnouts of all types including diamond crossings & Derailing switches with 52Kg / 60Kg rail section on PSC sleepers on prepared ballast bed for New lines or during total closure of section at indicated location as per standard drawing, duly leading sleepers, rails, switches, crossings, fastenings including rail cutting, drilling, fixing of all components, fittings with housing of tongue rails as per requirement of signaling, preparing ballast bed, filling and spreading of ballast as required, linking of turnout with track, attending track parameters including lifting, providing one round of packing to make track fit for 20 kmph speed including lubrication of fittings/fastenings, complete as directed by Engineer in-charge.
1 in 12 Turnouts Lifting for increase in ballast cushion of existing points & crossing layouts up to 75mm or part thereof including approach and exit sleepers including one round of through packing, correcting the disturbed sleeper spacing, tightening of fittings, boxing of ballast and ramping out on either side at slope not steeper than 1 in 1000 or as directed. Note: Item will be paid only when lifting is 50mm or more.
1 in 12 Points & Crossing HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY Lifting the newly inserted BG 60 Kg. / 52 Kg. turnouts/ trap switches to required level to provide full ballast cushion as per approved drawings after initial laying with Railway's stone ballast in convenient stages including one round of through packing after completion of final stage of lift, levelling, aligning, gauging and boxing to standard profile to make it fit for 20 kmph with all lead and lifts, complete in all respect and as directed by the Engineer-in-charge. Note: 1. The item shall be used only when UNIMAT is not available for the work before the turnout is opened for operation. 2. Leading and dumping of ballast will be paid separately under relevant item.
For 1 in 12 Points & Crossing Recoupment of ballast in running line with railway's stone ballast from existing stacks available along alignment either on top of cutting or on cess or at toe of bank by head leads or by any other means and spreading to make up deficiency in the required profile with contractor's labour, tools & plants, as directed by Engineer-in-charge. Note: Payment shall be made based on ballast stack measurement.
For average lead up to 50m and lift cum up to 5m
Extra over item no. 082011 for each Each additional average lead of 50m or part thereof when total average lead exceeds 50m, but up to 250m. Note: This item may be used only in exceptional circumstance under prior order on record.
Lifting and packing for regrading TRM the existing PSC sleeper track to required height / level in stages not exceeding 75mm or part thereof at a time, providing permissible ramp for the track, insertion of moorum / sand / stone ballast uniformly under the existing track and placing the same to safe approved gradient, gauge, cushion including levelling and one round of through packing to allow train movement at restricted speed of 30 kmph for a specified length with all leads & lifts and fixing, marking, painting rail level pegs at every 30m interval. Note: Lifting of track shall be done in stages as per procedure prescribed in latest edition of IRPWM to get the proposed final level as per approved working profile, as directed by Engineer in- charge.
Extra for additional lift over 75mm TRM for every 50mm lift or part thereof up to 275mm for item nos. 083010 for each TRM. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Boxing and profiling of ballast as TRM per procedure prescribed in latest edition of IRPWM including cess dressing on both sides of track. The work will include removing excess ballast from track and putting the same in crib and shoulder by leading to a maximum of 50m including crossing of track, deweeding on ballast section etc and as directed by Engineer-In charge.
Loading Railway's ballast, collected cum at yard / depot into Railway's BOB / BKH / any other type of open wagon, using Mechanical Loader or any other method with all lead and lifts, as directed by Engineer in- charge. Unloading of ballast from Railway's Hopper Wagons, quantity distribution as per pre-defined site requirement, clearing infringements/jammed ballast, distributing the unloaded ballast uniformly over the track, profiling and boxing following all prescribed safety norms.
Under Traffic Block Conditions:
Spreading of ballast, from existing cum stacks available along formation on top or at cess, in required uniform thickness, compaction of ballast layer laid on new formation at all the locations with smooth wheeled power roller of 8-10 tonne capacity to sufficient number of passes to form consolidated ballast bed of approximately 250mm thickness to a width of 4m symmetrical to centre line of proposed track in correct line & level with all ascents & descents, as directed by Engineer in-charge. Note: Item is inclusive of (a) providing ramp for taking roller to formation and removing the same & making good formation after completion of work; (b) redistribution & leveling of excess ballast while rolling to obtain uniform plane cambered surface. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY Linking of BG track (except at LC, Bridges and SEJs) with any type of rail section and sleeper of specified density, on ballast bed spread and compacted with suitable roller, over prepared formation including leading free rails/welded panels available along the alignment on to formation, leading and spreading all fittings and fastenings, spreading of sleepers at specified spacing, squaring, placing of rails over sleepers and fixing rails to sleepers with all types of fittings and fastenings to correct gauge & alignment, lubrication of fittings and fastenings with contractor's grease as per IRPWM standards with contractors labour, tools, consumables, with all lead, lifts etc. complete and raising, levelling and initial packing of track to make it fit for 30 kmph and meet other prerequisites prescribed in Indian Railway Track Machine Manual for deployment of Tamping Machine. Note: 1.Rail cutting and Hole drilling shall be paid separately. 2.Spreading of ballast and compaction shall be paid separately under relevant item.
For sleeper density of 1540 sleepers TRM per km Shifting / Slewing the existing or newly assembled track of any rail section with any type of sleepers and any density under line block to correct locations & alignment and attending to one round kutcha packing to run safely at 20KMPH speed with all contractors tools and consumables complete and as directed by Engineer in-charge.
Maximum Shifting / Slewing for TRM more than 1 metre & up to 2 metres First or Second Through Packing of track of all sleeper density including giving a general lift, as desired to eliminate sag after Deep Screening work, lifting of track, lowering of track and major realignment of curves and formation rehabilitation as per procedure prescribed in latest edition of IRPWM. Note: General lift is normally 25 mm and isolated lift may be up to 50 mm.
For PSC Sleeper Track with Sleeper TRM Density of 1540 HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY Through packing of points and crossings, derailing switches including gauging, fittings recoupment, ballasting as required, elimination of sag and to the required alignment after Deep Screening as per procedure prescribed in latest edition of IRPWM complete as per direction of Engineer-in-charge. Note: This work shall be operated in exceptional cases with written approval at DEN level when UNIMAT is not available and immediate packing is required to pass train over it.
1 in 12 PSC layout Maintenance of track on main line & loops, Points & crossings etc. including special attention to section for carrying out various maintenance works listed in Indian Railways P.Way Manual / Bridge Manual for safe running of goods and passenger trains with contractor's tools / labours etc. complete, as directed by Engineer in-charge. Note: Contractor shall arrange one gang at any point of time comprising of minimum specified labours with sufficient experience in P.Way working.
One mobile Gang comprising of 15 Gang Day physically fit labours plus 1 Mate. N o t e : (1) In case, contractor provides less no. of Labour/Mate or for non availability of vehicle, payment will be deducted for each such person or non-availability of vehicle @ 20% of the accepted item rate, separately for each shortfall. (2) The Contractor shall keep one pick up Truck of minimum 1.5T payload capacity with Driver all the time and all expenditures for running at an average of 80 kms per day shall be born by the Contractor. Anti-corrosive painting of rail outside track on rail bottom, web, foot and fishing plane with two coats of thickness of 100 microns each by bituminous black paint confirms to IS-9862 of reputed make including surface preparation, as a complete job as per procedure prescribed in latest edition of IRPWM.
For 60 Kg Rails HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY Carrying out pre-tamping, during tamping and post-tamping work for tamping track with all types of rails, sleepers & sleeper density by various Track Tamping machines, like CSM,DUO/3X Machines which include : (1) Re-adjustment of ballast, heaping-up of ballast, filling-up of cavities in tamping zone by picking ballast from stacks / shoulders / crib of adjoining track up to lead of 50 m to ensure effective packing; (2) Clearing of ballast on sleepers to make them visible to operator, (3) Clearing of ballast over rail foot to facilitate holding of rail by rollers of TTRM; (4) Digging, screening and replenishment of ballast at mud pumping / rounded ballast in sleeper crib location; (5) Tightening of loose fittings immediately before & after tamping; (6) Replacement of broken / missing fittings supplied by Railway; (7) Correcting displaced sleepers to position along with squaring; (8) Re-setting of worked- out / fallen fittings. (9) Removing and re-fixing joggled fish plates & wooden blocks, wherever necessary; (10) Manual consolidation of ballast in crib / shoulders; (11) Removing and refixing of traction bonds during the block in electrified sections (12) Dressing of ballast Note: 1. Tamping blocks are not identical & it may be given at any time either during day or night. 2. Stages of payment a) 30% of the rate will be paid on completion of pre tamping attention, b) Balance 70% of the rate will be paid on completion of post tamping. 3. Recovery at the rate of twice the above applicable rate will be effected in case contractor fails to carry out pre/during/post operation. 4.Payment shall be made only once in irrespective of numbers of TTRM packing round and after restoration of normal speed and restoration of complete ballast profile.
For day time block working
New Line Section, not opened for TRM traffic Carrying out pre-tamping, during tamping and post-tamping works prescribed in current version IRTMM/IRPWM for tamping of Turnouts of all types Under Conditions not requiring Traffic Block.
1 in 12 Turnouts HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Carrying required for UTV working under line block i.e., turning of rails/ Sleepers and keeping in position for fixing of UTV clamps to rail, keeping rails/PSC Sleepers in position while loading into BFR, removal of clamps on BFR for releasing loaded rail/Sleepers, adjusting of rails/Sleepers on BFR etc. by providing minimum of three men in a shift of 8 hours, with all contractor's tools, all lead, lift, crossing of tracks etc., complete and as directed by the engineer - in - charge. Note: In case, contractor provides less no. of Labour, payment will be deducted for each such person @ 2/3 rd of the accepted item rate. Quick cutting with abrasive rail cutter of all types of rail sections including wear resistant, head hardened rails up to 110 UTS, with contractors tools & plants, equipment, consumable with all lead & lift etc. complete as directed by Engineer in-charge. Abrasive Rail Cutter will be as per RDSO Specification No. TM/SM/1 (Rev. 01 of 2012) with latest status of RDSO; Rail Cutting Wheel Abrasive Disc will be as per RDSO Specification No.TM/SM/2 (Rev. 01 of 2020)
60 Kg - 110/90 UTS - Outside Track Each
60 Kg - 110/90 UTS - On Running Each Line Drilling holes of 16 mm to 32 mm dia. with Rail Drilling machine including chamfering with appropriate chamfering tools in all types of rail section with contractor's tools & plants, equipment, consumable with all lead & lift etc. complete, as directed by Engineer in-charge. Rail Drilling Machine will be as per RDSO Specification No. TM/SM/3, dated 24.04.1991.
On Running Line Loading of rails of any section and length up to 13 metres in Wagons / Truck / trailer including lead up to 50 metres and lift up to 5 metres.
I n Wagon handling is possible a n d traffic block is not required or in Truck/trailer. Loading of tongue rail, stock rail, switch assembly and crossings of any section and length, SEJ, Glued joint etc. with / without P.Way fittings and fastenings, in Wagon / Truck / trailer including lead up to 250 metre and lift up to 5 metre. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
I n Wagon handling is possible a n d traffic block is not required or in Truck/trailer. Loading, leading and unloading of 52Kg / 60Kg rail up to 13 metre length by Railway's Rail Dolly / Dip Lorry to the nominated location under traffic with line protection in case road carriage is not possible with different lead with a lift up to 5 metre during block period.
For lead up to 500 metre.
For lead beyond 500 metre and up MT to 1 Km. Unloading of rails of any section and length up to 13 metre, in neat manner for Railway usage from departmental material train (DMT) or contractor's / Railway's Truck/trailer including lead up to 50 m e t r e , lift up to 5 metre and stacking in prescribed manner.
From Wagon where mechanical MT handling is possible a n d traffic block is not required or in Truck / trailer. Unloading of all type of rails of length 130 metre and beyond from end unloading rake and keep the panels in head-up position at specified distance from centre of track clear from any infringement.. Note: Contractor has to keep Oxygen and Acetylene gas with cutter as standby during the period of work.
During period of traffic block Loading of 52kg / 60kg PSC normal line and special sleepers up to 2.75 metre length in Depot / Station / Mid-section between stations in a neat manner to departmental material train (DMT) or contractor's / Railway's Truck/Trailer with crane or any other means including crossing of one track with free lead up to 250 metre and lift up to 5 metre, if required with contractor's labour, tools & plants, machinery, consumables etc. Note: In case of any damage to sleeper during loading, penalty @ 50% of the all inclusive cost of sleeper shall be levied.
I n Wagon handling is possible a n d traffic block is not required or in Truck / trailer HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY Loading of 52kg / 60kg PSC line and special sleepers beyond 2.75 metre length including existing fittings and fastenings in Depot / Station / Mid-section between stations in a neat manner to departmental material train (DMT) or contractor's / Railway's Truck/trailer with crane or any other means including crossing of one track with free lead up to 250 metre and lift up to 5 metre, if required with contractor's labour, tools & plants, machinery, consumables etc. Note: In case of any damage to sleeper during loading, penalty @ 50% of the all inclusive cost of sleeper shall be levied.
I n Wagon/Truck / trailer where MT mechanical handling is possible and traffic block is not required. Loading, leading and unloading of PSC Sleepers of 52Kg / 60Kg by Railway's Rail Dolly/ Dip Lorry to the nominated location under traffic in case road carriage is not possible for different leads and lift up to 5 metres.
For lead up to 500 metres
For lead beyond 500 metre and up MT to 1 Km Loading, leading and unloading of all types of P.Way fittings and all other miscellaneous material except Rails, sleepers, switches, crossings, SEJs and Glued Joints by road vehicles for different leads. Note: Lead shall be the shortest motorable road length between the points of loading and unloading.
Lead up to 5 Km
Lead beyond 5 Km and up to 10 km MT
Lead beyond 10 Km and up to 20 MT km
Lead beyond 20 Km and up to 30 MT km
Lead beyond 30 Km and up to 50 MT km
Lead beyond 50 Km and up to 100 MT Km
Lead beyond 100 Km and up to 150 MT Km
Extra for every Km per MT beyond MT-Km 150 Km over item no. 172047 Transportation of Rails, sleepers, switches, crossings, SEJs and Glued Joints by road vehicles for different leads. Note: 1 . Lead shall be the shortest motorable road length between the points of loading and unloading. 2. Loading and unloading shall be paid extra under relevant items.
Lead up to 5 Km
Lead beyond 5 Km and up to 10 km MT
Lead beyond 10 Km and up to 20 MT km HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Lead beyond 20 Km and up to 30 MT km
Lead beyond 30 Km and up to 50 MT km
Lead beyond 50 Km and up to 100 MT Km
Lead beyond 100 Km and up to 150 MT Km
Extra for every Km per MT beyond MT-Km 150 Km over item no. 172057 Unloading of 52kg / 60kg PSC line and special sleepers up to 2.75 metre length in Depot / Station / Mid-section between stations in neat manner for Railway usage from departmental material train (DMT) or contractor's / Railway's Truck/Trailer with crane or any other means including crossing of one track and lead up to 250 metre & lift up to 5 metre with contractor's labour, tools & plants, machinery, consumables etc. Note: In case of any damage to sleeper during loading, penalty @ 50% of the all inclusive cost of sleeper shall be levied.
From Truck / Trailer Unloading of 52kg / 60kg PSC special sleepers beyond 2.75 metre length in Depot / Station / Mid- section between stations in neat manner for Railway usage from departmental material train (DMT) or contractor's / Railway's Truck/Trailer with crane or any other means including crossing of one track and lead up to 50 metre & lift up to 5 metre with contractor's labour, tools & plants, machinery, consumables etc. Note: In case of any damage to sleeper during loading, penalty @ 50% of the all inclusive cost of sleeper shall be levied.
From Truck / Trailer Unloading of Switches / Crossings / SEJ Rails / Glued Joints of any rail section and length with or without P.Way fittings & fastenings in neat manner for Railway usage from departmental material train (DMT) or contractor's / Railway's Truck/Trailer with lead up to 250 metre & lift up to 5 metres.
From Truck / Trailer Collection, segregation and stacking of various scattered P.Way materials at nominated stacking location with serviceable and un- serviceable ones separately within a lead up to 500 metre and lift up to 5 metre including crossing of track(s) wherever necessary as directed by Engineer-in-Charge.
Rails, switches, crossings, Glued Joints, Check Rails etc.
All type of PSC sleepers HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
P.Way fittings of all types and other MT similar loose items Manufacturing, fabricating and supplying retro-reflective Engineering Indicator boards, made of 2mm thick aluminium sheet or 3mm thick aluminium composite sheet, face to be fully covered with high intensity encapsulated type heat activated retro-reflective sheeting conforming to type-IV of ASTM-D4956-01 in yellow & black or other colour combination including subject matter, message, symbols, borders etc. as approved by Engineer In-charge or as per IRPWM guidelines, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back- support frame of M.S. angle iron of size 25mm x25mm x 3mmprovided all along the edges of board with theft resistant measures back side of board shall be with non-peelable weatherproof paint, consisting of one coat of zinc chromate primer and two coats of epoxy paint. Vertical post shall have black & white anti-corrosive paint or powder coating complete, as directed.
Caution Indicator Board of size Each 1400mmx400mm with back support frame fixed to vertical post of MS angle of size 50mmx50mmx6mm of 3650 mm long
Speed Indicator Board of equilateral Each triangular shape having each side of 1000mm with back support frame fixed to vertical post of MS angle of size 50mmx50mmx6mm of 3650 mm long
Termination Indicator Board of Each Circular shape having diameter of 1000mm with back support frame welded to vertical post of MS angle of size 50mmx50mmx6mm of 3950 mm long
Manufacturing, supplying and fixing Each Curve Indicator / Point Indicator / SEJ Boards to be provided at various locations on formation, made out of MS sheet 2mm thick of size 450mm x 300mm duly fixed with MS frame of 25mm x 25mm x 3mm angle welded to 50mm x 50mm x 3mm MS angle, 1000mm long post split and bent 100mm at bottom end with all lead & lift as per specification and including painting of details with enamel paint, as directed by Engineer in- charge (Earthwork & concreting will be paid separately) HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY Hiring of machinery for minor miscellaneous works for short duration including operator/driver, fuel, lubricants and consumable. The contractor shall arrange all statutory permits as required by rules and regulations prevailing in the area of work. Payment shall be made for actual working hours at site.
JCB Backhoe Loaders 3DX Plus or Hour similar with minimum 1.10 cum bucket capacity
Manufacturing and fixing buffer Each stop with Railway supplied rails, cutting, including bending of rails as per plan ,with all contractor's labour, materials, tools, plants etc. and all lead and lift including crossing of track where necessary a n d as directed by Engineer in charge at site. Note: Excavation, fixing rails in cement concrete, drilling of holes will be paid separately. Total 10229115.98
Item Breakup - M-NS Items Civil
Preparation of Site plan, GAD and Sqm designing foundation and other structural design, preparation of detailed structural drawing and submission of design calculation with check print for verification and corrections, carrying out correction as per corrected check print and submission of 4 copies of drawing with negative and floppy etc., as per general arrangement drawing a n d submission of completion drawing as per the execution in tracing paper/tracing film after completion of work duly incorporating any deviation/changes carried out during execution from original a p p r o v e d drawing without completion drawing final bill will not be finalized.
Float glass panes of nominal Sqm thickness 5 mm (weight not less than 12.50 kg/sqm)
Galvanised wire mesh of average Sqm width of aperture 1.4 mm and nominal dia of wire 0.63 mm
Weather Silicon Cartidge)
Hermetically sealed double glazed Sqm unit made with 6 mm thick clear float glass both side having 12 mm air gap
Toughened glass 12 mm thickness
Carriage of Materials : Mechanical cum Transport including loading ,unloading and stacking: Sand, stone aggregate below 40 mm nominal size-5-10km HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supplying and spreading of sand in cum lawn area, including watering, and dressing complete.
Hardening compound
Supplying and applying surface Sqm hardener for sqm concrete floors ready to use, specially graded, non metallic and mineral aggregate dry shake surface hardener free from oil and grease to be sprinkled at 9 kg/sqm of surface area. Complete with finishing
"Providing and laying Cement cum concrete or RCC M25/M30/M35/M40 in pre-cast for Platform wall, raft, abutment, dirt wall, return wall, wing wall, fly wing wall, retaining wall, approach slab for inspection steps, mslab for inspection path, coping slab for bridge, slab for bank slope, foott path slab, wearing course, ballast retainers, RCC railing, inspection paltform, pedestal, boxes and other miscellaneous works using well graded stone aggregatre of 20mm nominal size, Transportation to site from casting yard, launching, laying, aligning and jointing the pre- cast items including road movement upto the the nearest approachable point and short leading by rail lorry etc... Wherever required as directed by Engineer-in- charge. The rate is inclusive of cost of all men, machinery, materials and construction / repair of approach roads as per requirements for which no extra payment will be made. Payement to be released in two stages. 1. 50% on casting of precast components, 2. 45% on transportation and launching of precast components to the site, and 3. balance 5% on completion of balance works 4. Rate excluding cost of Cement & Steel work which will be paid under relavant items of Schedules."
Carriage of Materials : Mechanical cum Transport including loading ,unloading and stacking: Manure or sludge-2km
Supply of Insecticide/Pesticide : i. Kg Lindane dust
SUPPLY OF FERTILIZER/ORGANIC Kg MANURE : vi.Zinc Sulphate
Supply of Plants/Trees - supplying- Each Cassia fistula(4to5ft)
Supply of Plants/Trees - supplying- Each Jacaranda mimosaefolia (4to5ft)
Supply of Plants/Trees - supplying - Each Plumeria alba (4 to 5ft)
Supply of Plants/Trees - supplying- Each Plumeria rubra (4 to 5ft)
Supply of grease graphite (FWP Kg 2023-24) HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Carriage of Materials : Mechanical cum Transport including loading ,unloading and stacking: Earth-2 km Total 4449906.00
Item Breakup - N-General Electrical Items
Wiring for light point/ fan point/ Numbers exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable surface GI box / recessed PVC Box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supply and fixing of 50MM dia, Metre medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case ofrecessed conduit as required
Wiring for circuit/ submain wiring Metre alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring Metre alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring Metre alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing suitable size Numbers surface GI box / recessed PVC Box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supplying and fixing suitable size Numbers surface GI box / recessed PVC Box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supplying and fixing 3 pin, 5 A Numbers ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing PVC batten/ Each angle holder including connections etc. as required.
Supplying and fixing following way, Each single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) -6 way, Double door
Supplying and fixing following way, Each horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)-4 way (4+12) , Double door
Supplying and fixing 5 A to 32 A Numbers rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A Each rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A Numbers rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following Each rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required-25 A
Supplying and fixing 5 A to 32 A Each rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.-40A HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supply and fixing of 20 A, 240V, Each SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with the connections, testing and commissioning etcas required.
Earthing with GI earth pipe 4.5 Mtr Each long, 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc, with charcoal / coke and salt as required.
Laying of one number PVC insulated Metre and PVC sheathed / XLPE power cable of 1.1 KV grade of upto 35 sq. mm size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Laying of one number PVC insulated Metre and PVC sheathed / XLPE power cable of 1.1 KV grade of above 35 sq. mm and upto 95 sq. mm size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Supply and making end termination Metre with brass compression gland and aluminium lugs for 4 x 95 sqmm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade.
Supply and making end termination Metre with brass compression gland and aluminium lugs for 16 sqmm size, 4 core PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade all as per detailed specified and directed.
Supply and making end termination Metre with brass compression gland and aluminium lugs for 4 x 35 sqmm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade all as per detailed specification and as directed.
Providing and making steel pole cum collar with cement concrete (1:3:6) with stone aggregate 20mm nominal size in foundations of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)
Providing ,laying and fixing 100mm Metre dia G.I pipe (medium class) in ground complete with G.I fittings including trenching (75mm deep) and refilling etc as required HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supplying, installation, Testing & Each Commissioning of LED surface mounted Batten light 18- 22 watt of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency>85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 20% , P. F.0.9, IP20, CRI >75, life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >75 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness 1.20 mm). The fitting shall comply the CEE/SWR Specification enclosed in specification. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supplying, installation, Testing & Each Commissioning of Flood Light 50 W powder coated pressure die cast aluminum body (System lumen efficacy >75 lm/Watt) with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 20% as per IEC 61000-3-2 , P.F.0.95, IP-66,IK-10, CRI >75 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).The fitting shall comply the CEE/SWR Specification enclosed in specification HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supplying, installation, Testing & Each Commissioning of Flood Light 250 W powder coated pressure die cast aluminum body (System lumen efficacy >75 lm/Watt) with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 20% as per IEC 61000-3-2 , P.F.0.95, IP-66,IK-10, CRI >75 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).The fitting shall comply the CEE/SWR Specification enclosed in specification HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supplying, installation, Testing & Each Commissioning of 120 W Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver eciency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver effciency >85%,THD < 20% as per IEC 61000-3-2 , P. F.0.9, IP- 65,CRI >75, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >75 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)-120W.The fitting shall comply the CEE/SWR Specification enclosed in specification
Supply, Installation, Testing and Each Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374- 2019), THD (Total Harmonic Distortion) less than 5%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan 1200mm, service value 6.0 CM/Min/Watt, air delivery 220 CM/Min (Minimum) Supply, earthing etc. complete as req. The fan shall comply the CEE/SWR Specification enclosed in specification HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Fabricating, supplying and erection Each of 6ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for 6m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom 130 mm , top 70mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.
Fabrication, Supplying, Erection, Each Testing and Commissioning of 16 mts long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hotdip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supplying, and fixing of Hot dip Each Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Double Arm Bracket with 1000 mm Standard 40/50 mm dia
Supplying of 1440rpm heavy duty Numbers exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete-12" Sweep (300 mm)
Installation charges for split type air Numbers conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.
Supplying vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.
Supplying, erecting, testing and Each commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete.-3 kva
Supplying & fixing of retro fit type- Numbers LED bulb 12W, 6500K with OPAL acrylic diffuser comprising of LED source as per detailed specification
Supplying insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 standcopper wiring between indoor and outdoor unit Leak testing oiland gas charging for additional piping length of tube. split type HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Trenchless cutting to cross the Metre cable across the track / road,duly supply and provided with HDPE pipe of size 90.9 x76.5mm to pull LT/HT UG cable & Fixing/laying of HDPE pipe of size 90.9mm x 76.5mm as per instruction of Engr-in-charge (Scope includes cost for horizontal driIIing, cost of pipe and laying of pipe etc.b ut charge for laying of cable is not included)
Supply manufactured from special steel along with nuts, washers, anchor plate and common template.
Supply of outdoor stand mounted Set feeder pillar with 36A TPN MCB incomer, single dial time switch,25A TP contactors for the automatic switching of luminaries, power tool control with 2no 9A contactorsand raise lower push button,Incoming 35 sq.mm and out going16 & 2.5 sq. mm terminals.
Construction of shallow foundation Job with M20 grade concrete for the high mast considering the safe soil bearing capacity at site as10 T/sqmtr at 2metre depth with all materials and labour.
Installation of the mast feeder pillar Numbers by grouting the stand in concrete
"Supply, fixing, connecting, testing Each and commissioning of LT Control Panel, cubical indoor type, 200 A, 3 phase 4 wire system, insulated copper bus bars of size 20 mm x 6 m m , opening from both front and rear sides, separate compartments for each control gear, cable alley and provision of knock out type entry plates suitable up to 95 sqmm size cables, panel made out of 14 guage CRCA sheet, epoxy powder coated with grey matt finish ,including base frame made out of 50 x 50 x 6 mm angle iron sections, embedded in PCC 1:3:6 foundation, consisting of the following switchgears and metering devivces:- i) MCCB, 415 V AC, 200 4P, 36 KA, microprocessor based release - 2 No ii) MCCB, 415 V AC, 100 4P, 30 KA, microprocessor based release - 4 No iii) ONLINE CHANGE OVER SWITCH-1 No, 400 A (iv) 40 A 415 V, 4 pole isolator-10 Nos (v) Capacitor bank of 10 kVAR capacity with Multifunction meter, LED pilot lamps and phase selector switch with all concern materials and works as per detail specification." Total 4131375.00
Item Breakup - A1-Horticulture
Item Breakup - I1-Survey works NS
FLSD-16 : Minor Bridges / SUBWAYs Each / FOBs: Preparation of the General Arrangement Drawing for all Minor bridges / SUBWAYs / FOBs through MX Rail/ AutoCAD for railway standards / formats as per Check list of Dyce / planning / BNC based on finalized L - section for the proposed alignment, hydrological investigation & detailed geotechnical investigation carried out by the consultant at proposed bridge locations, on good quality tracing paper and submitting the same to Railway administration for approval and carrying out the corrections as instructed by railway with all consultants own men, material, tools & plants, Computer systems etc., as directed by Engineer in charge. Notes: 1) MINOR BRIDGE GAD should include incorporation of - a) Sub structure details with type of construction, type of foundation ( pile / open ), depth of foundations, footing details / pile founds details, foundation pressure, abutments / pier / Box details duly showing bore log details of sub soil along with SBC details of every soil strata at every abutment & piers / Box locations b) Span arrangements with details of Bed level, HFL, VC, Free board, Scour depth, Rail level, formation level, Clear span, effective span, catchment area, Q50 discharge c) Super structure details like type of structure (Steel / PSC / RCC), type girder / slab / Box details, depth of construction, bearing details, wearing coat, track structure with cushion details d) Approach details like parapets, approach slab, back fill material as per RDSO specifications, protective works such as wingwalls, bank toe walls, pitching, type of flooring / drop wall / curtain wall details as per scour depth & silt factor criteria. e) Modus operandi of entire bridge construction 2) SUBWAY GAD should include incorporation of - a) Sub structure details with type of construction, type of foundation, depth of foundations, foundation details, foundation pressure duly showing bore log details of sub soil along with SBC details of every soil strata b) Span arrangements of Subway (RCC Box) with details of carriage way of Box, footpath, total barrel length required to cater all existing tracks including future tracks, height of subway required as per standards. Total 26664.00
Item Breakup - I2-Survey works SOR
Completion drawing of building
Completion drawing of land plan
Completion drawing of way side Each station Total 19327.98
Item Breakup - SA-S&T SOR Items
24.00 Lighting Unit Red with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
26.00 Lighting Unit Yellow with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
15.00 Lighting Unit Green with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
20.00 LED Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest.
40.00 Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest.
3.00 Route indicator (LED Single digit) from 1 to 9 & G with white LED (with housing) as per the latest specification. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
22.00 140mm dia, 3.6m tall as per latest specification IRS:S 6-81 Rev.3 or latest
22.00 and Shoes to suit CLS pole 3.6m, as per latest specification.
22.00 Signal Pole 140mm dia as per latest specification.
2.00 made of cast iron with necessary inspection as per latest specification.
14.00 made of cast iron with necessary inspection as per latest specification.
12.00 unit assembly as per RDSO Spec. No. RDSO/SPN/194/2006 Rev .2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 08 Nos)
10.00 unit assembly as per RDSO Spec. No. RDSO/SPN/ 194/2006 Rev.2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 12 Nos)
22.00 foundation as per Drg.No.SG/SWR/052 using metallic templates, for erection of colour light signals up to 4 aspects. [Foundation bolts, cement, river sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
22.00 pole, mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament switching units, CLS transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of speed limit board wherever necessary,termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down. ['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Collar-rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor].
16.00 complete as per latest specification.
16.00 bolts and nuts, erection of Calling On Signals/ 'A' marker lights, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock, number plates/ marker boards and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Offset bracket from slipping down. (Supply of Calling On Signal/ 'A' marker light, LED aspects/holders & bulbs and Off set brackets is not covered in this item). ['U' bolts and nuts, through bolts with nut, wire PVC 3/0.75mm copper, EWS lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].
14.00 complete with hood etc., as per latest specification. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
16.00 bolts and nuts, erection of Post type shunt Signal, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock and painting of one coat of red oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down. (Supply of Post type Shunt Signals, LED aspects and Off set brackets is not covered in this item). ['U' bolts and nuts, through bolts with nut, wire PVC 3/0.75mm copper, EWS lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].
3.00 - complete with surface base, signal pole, hood etc., as per latest specification.
3.00 concrete foundation as per Drg, No.SG/SWR/053 using metallic templates, for erection of Ground type colour light Shunt Signal. [Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor].
3.00 signal complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing of lens guards, number plate, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint. (Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this item). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
4.00 arrangement for Signals in RE area as per standard practice. The work comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 SWG GI wires from the screening arrangement up to surface base as per the instructions of Railway representative at site. [All materials required for this work shall be supplied by the Contractor].
2.00 type Goods Warning Board as per practice & SEM (Angle/Rail is to be supplied by Railway).
6.00 type Calling- On/STOP/BSLB/Legend boards as per practice & SEM (Angle/Rail is to be supplied by Railway).
1.00 per required lengths for Various Boards like Goods warning/Calling on/Axle counter & etc (1 PER UNIT= 1 PER TON)
and Existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling.
4.00 shunt signals along with surface base, signal post etc carefully without any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also includes breaking and removal of concrete foundation and refilling of the resultant pit by ramming and levelling.
6.00 of STOP board/Warning board/ LEGEND boards along with rails, accounting and stacking them neatly at a place as instructed by Railway representative at site. Also, the resultant pits shall be resurfaced and consolidating by ramming and levelling. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
2.00 complete, termination of tail cables, wiring as per approved circuit diagram using wire PVC 3/0.75mm & 16/0.2mm copper, provision of EWS - required No's., and painting. (Supply of route indicators is not covered in this item) [Fixing bolts and nuts, EWS locks wires PVC 3/0.75mm & 16/0.2mm copper, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].
8.00 erection and painting of boards with LEGEND such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm, and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this item. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, river sand, cement, M.S.Flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor].
40.00 as per latest specification/drawing.
15.00 as per latest specification/ drawing.
1000.00 25 mm Centre, made up of PBT as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest.
300.00 centre as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest.
40.00 foundation and erection of Apparatus Case Full size as per Drg. No. SG/SWR/055 and fixing of 2 nos of "E" type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red oxide and two coats of aluminium paints, along with painting of termination and equipment particulars on the doors of apparatus cases as per instructions of railway representative at site. (Supply of apparatus case is not included in this item). [ Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the contractor]. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
15.00 foundation and erection of Apparatus Case Half size as per Drg, No.SG/SWR/056, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this item). [Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor] HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
3000.00 and power cables on25/60mm PBT terminals on phenolic sheet and internal wiring on terminal in new apparatus cases, cable termination boxes and in gate lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of phenolic synthetic industrial fiber base fine waves cotton fiber board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan painting of particulars on sleeves and also on the inner side of the doors of apparatus case. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and fuse blocks is not covered in this item). { cement, teakwood cable clamp 50mmX 50mm, base planks 100mm x 25mm, phenolic synthetic industrial fiber base fine weave cotton fiber sheet - 6mm thick to IS specification 2036 -1995 - type F5, PVC / Nylon sleeves , varnish, paints, bolts, nuts, and washers, non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm X 100mm X 60mm, copper bus bars, brass screw, river sand, wire PVC 3/0.75mm copper and other miscellaneous materials shall be supplied by the contractor) HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
300.00 and power cables on PBT fuse block on phenolic sheet and internal wiring on fuse blocks in new apparatus cases, cable termination boxes and in gate lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of phenolic synthetic industrial fiber base fine waves cotton fiber board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan painting of particulars on sleeves and also on the inner side of the doors of apparatus case. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and fuse blocks is not covered in this item). ( cement, teakwood cable clamp 50mmX 50mm, base planks 100mm x 25mm, phenolic synthetic industrial fiber base fine weave cotton fiber sheet - 6mm thick to IS specification 2036 -1995 - type F5, PVC / Nylon sleeves , varnish, paints, bolts, nuts, and washers, non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm X 100mm X 60mm, copper bus bars, brass screw, sand, wire PVC 3/0.75mm copper and other miscellaneous materials shall be supplied by the contractor) HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
4.00 Relay Frames of suitable size to Hold up to 4 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor].
8.00 Relay Frames of suitable size to Hold up to 8 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036-1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item ). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
16.00 Relay Frames of suitable size to Hold up to 12 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor].
40.00 Signals, Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, caring out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.
25.00 cases (Full/ Half/ Quartersize) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays of all types EKTs, Secondary Cells, power equipment's, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site.
30.00 GKP. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
30.00 providing foundation (a pit of size 400mm x 400mm x 1000mm is to be dig and cement concrete foundation in the pit in the ratio 1:3:6 to be casted) and fixing the frames/doors and E- type lock to the fencing with supplied material. The rail post/angular is to be erected up right in the foundation. All materials are to be arranged and used by the contractor (Rail post / angular /frames /Fencing/ E type locks will be supplied by railway). Cutting of rail post / angular / fencing to the required length, transportation to the site is to be done by the contractor.
earth boxes/signal foundations for a width of 0.5m on all sides, up to a level 150mm below the foundation top. This work includes consolidation of earth by watering and ramming. The earth shall be taken from Railway premises as instructed by Railway representative at site.
30.00 for the location boxes. The work involves erecting posts using GI pipes 25mm dia - 3m long near the location boxes at an interval of 2m and providing fencing using Barbed steel wires around the location boxes. The GI pipes shall be buried to a depth of 1m. The barbed wire shall be providing using 14 SWG GI wire (2 wires) barbed at 6" interval. The wires shall be provided from ground level to the top of post at an interval of 6". The work also includes erection of two rail posts, fabrication of a gate using MS angles 50x50x5mm and MS flats 50mmx3mm and fixing it on the rails and provision of locking facility as per the instructions of Railway representative at site. (Rails of different lengths will be supplied by Railways. The Contractor has to cut the rails to the required lengths as per the requirement). [GI pipes 25mm thick, barbed steel wire, MS angles 50mmx50mmx5mm and MS flats 50mmx5mm for fabrication of gate, and all other miscellaneous materials required for the work shall be supplied by the Contractor].
16.00 IRS type 220 mm throw with Lock and detector Slides, Cable termination box and clamp lock arrangement with Ground connection, Insulation's etc. for thick web switch ,confirming to RDSO Specification no IRS:S24- 2025 Revision 3.0 or latest. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
16.00 Connection, Made of Nylon for 220mm throw Point Machine as per latest specification No. IRS.S.40/84 Amdt No.01 or latest. One Set consisting of :- a) Insulating Washer Drg. No.-S-8640 = 12 Nos. b) Insulating Washer Drg. No.- S- 8640/1=04 Nos. c) Insulating Washer Drg. No.-S-8640/2=02 Nos. d) Insulating Bush Drg. No.-S- 23199=06 Nos. e) Insulating Bush D7Drg. No.-S-3463=01 No. f) Insulating Bush Drg. No.- S22179=02 Nos. g) Insulating Bush Drg. No.-S-8912=02 Nos. h) Insulating Plate Drg. No.-S- 3404=02 Nos. i) Insulating Bush Drg. No.-S-8813 = 04 Nos.
2.00 IRS type 143 mm throw with Lock and detector Slides, Cable termination box with suitable ground connections, Insulation's etc. confirming to RDSO Specification no IRS:S24-2025 Revision 3.0 or latest
2.00 switch extension bracket to suit to universal point machine as per RDSO Drawing supplied by the Railways. (One set consists of 'D' clamp insulation - 2 No. Nylon insulation bushes 4 No., Nylon insulation washers - 8 No.)
2.00 type 143 mm and connecting all ground connections including wiring and termination in point machine and inter connections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw bar lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways. [All types of insulations connected to point work, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor]. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
16.00 termination box, wiring, testing and commissioning of IRS High Thrust point Machine 220mm.This includes fixing of point machine on MS plate fixed on sleepers complete with fixing of anti-theft covers, MS termination boxes, ground connections, required insulation, crank handle ward (wherever required) etc. This also include necessary adjustment and smithy work, drilling of holes on tongue rails, supply of all miscellaneous material such as flat, angle, bolt, nuts, pins etc.
and existing Point machines (all types) including ground connections and other accessories available complete without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site.
16.00 termination boxes on rails/L-angle and concreting as per RDSO Drawing , drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mmlong at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawal of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of CT boxes is not covered in this item. Rails of different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.) [Cement, iver sand, stone jelly of size20/25mm, paint, varnish, GI Pipes 32mm dia - 300mm long - 2Nos and 150mm long - 1 No., clamp nuts - 12mm thick - 2 Nos. for each pipe, fixing bolts and nuts with washers, EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor].
6.00 the Existing cable termination boxes, after releasing the base plank, Terminal blocks, Fuse Blocks, Terminal Boards, cut rails, pipes, etc., closing the resultant pits and consolidating it by ramming and levelling. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
40.00 with stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site.
Transportation, Electrically operated Lifting Barrier set with Hand generator with operating voltage of 24VDC. Each set consisting of 2 Nos. of Lifting Barrier Pedestals, each with 8 contact circuit controllers with top roller type Limit Switches (as per Design given in specification & approved by RDSO) Hand Crank, Electric Motor 24V DC. 2 GI sheet Booms of 32 ft length (4 section of 8 Ft long each) with new Octagonal shape as per RDSO drg. No. RDSO/S 11600. - Version 2.0 or latest, without fringes, with 2 stop boards in Trilingual i.e Hindi, English & Regional language and MS Counter weights and 02 nos. of boom supports with Motorized / Solenoid boom locking along with 01 no. of hand Generator cum Control panel to operate 2 barriers of a set with 1 selector switch, 3 buttons and 5 indication lamps, contacts, MCB's and relays.
1.00 feet long as per RDSO Drawing No, RDSO/S 11600 in 4 section of 8 feet each.
2.00 900mmX 900mmX900mm for pedestal, 400mmX400mmX 600mm for meeting post, fixing of lifting barrier boom, contact makers, termination of cables, wiring and painting as per the instructions of Railway representative at site. (Supply of pedestals, meeting posts, contact maker, electric lifting barriers, rail posts, cranks and 'A' type foundation is not covered in this item). [Concreting materials, bolts and nuts, wire PVC 3/0.75mm copper and all other miscellaneous materials required for the work shall be supplied by the Contractor]. (Unit = Per Boom)
6.00 Rotary type of required ward Nos. with keys, as per specification/ No. IRS S.21/2001 Rev.1.0 or latest. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
2.00 Handle Box/Emergency Key Box at Interlocked LC Gates, made of Teak wood with Glass fronted door as per specification. Polishing on all exposed surface and for with EKT inside the box. Micro push switch of suitable make with 2NO+2NC contacts and veeder counter non- reset type and wire them as per the approved circuit diagram. The box should have hinges and pad locking arrangements with one Lock with duplicate keys and key chain with label. (All materials except EKT are to be supplied by the contractors.)
4.00 without crank handle or on suitable fixtures at station/apparatus case, provision of economiser push switch with locking facility, wiring with wire PVC 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting. (Supply of electric key transmitter and crank handles is not covered in this item). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility by using 25mm thick teakwood, bolts and nuts, paints, push switches, padlocks and other miscellaneous materials required for this work shall be supplied by the contractor].
1.00 Telephone system with Voice Logger facility as per RDSO Spec No.RDSO/SPN/TC/51/2021 (Rev 1.0) or latest. consist of one master Telephone, 06 slave Telephone with modified surge protection & Line connecting unit and 24 Volt DC power supply unit with MF battery compatible with existing electronic LC Gate Telephone system.
1.00 Unit consist of 2 nos Horn Speakers, 2 Nos of Hooters and Amplifier with Trilingual i.e Hindi, English & Regional language voice announcement
1.00 Electronic Gate Warning equipment for each level crossing gate, one on each road warning signal, amplifier in the apparatus case with wire PVC 3/0.75mm and 16/0.2mm copper, and painting. (Electronic Gate Warning Equipment and amplifier will be supplied by Railways). [All wiring, fixing and painting materials shall be supplied by Contractor]. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
1.00 LC gates like SM slide instruments, illuminated diagram board, block counter, termination box, telephones, emergency key box, dismantling of ground lever frame along with all connected lever locks, 'E' type locks, HP locks, breaking and removal of concrete foundation, lock rods with rod roller trestles, complete assembly, cranks, compensators, 'A' type concrete foundation on the rod run, transmission wires single wire/double wire accounting and stocking them neatly at a place as instructed by Railway representative at site. After releasing any holes on the walls/ floor are to be filled with cement mortar and plastered.
4000.00 kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this item).
2500.00 kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying of cables is not included in this item).
2500.00 Capping (RCC Duct) of size 700mm Length X 500mm Width X 260mm height & Suitable cover plate of 40mm thickness as per Drg.No.SDO/Cable laying/ 007 (Annexure-10) as detailed in document No. RDSO/SI/G/2010 Ver.1.1 or latest on 'Guidelines on signalling cable laying'.
200.00 Cable channel of size, Width 240/340 mm, Height 155/230 internal/external, length 1 m produced of polyolefin with Fire protection class k-1 in accordance with DIN-53438 Part II for laying Signalling/Telecom cables, channel attachable to each other with male- female swallow tail connectors and having suitable detachable cover
6.50 Tape colour Orange, width of 250mm (10") by printing with black letters 'Indian Railway Signal/Telecom/OF Cable' on both sides
4000.00 by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
2500.00 by 0.5m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling
of Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters as per latest specification No. IS 4984: 2016 with latest amendments and Material Grade: PE 80.
100.00 Dia, 10mm thickness along with collars in trenches at places of platform cutting etc and wherever required as per the instruction of site engineer.
200.00 of not less than 30CMs in rocky terrain, concreting the trench with 150mm thick concrete with 1 cement, 2 sand, 4 grade stone 20mm nominal size. (All the materials are to be supplied by the contractor).
200.00 trench or GI pipe/DWC/HDPE pipe in which cable is already laid to a size of 300x300mm with 1:3:6 mortar. (All the materials required for the work should be supplied by the contractor).
of Metre Signaling/Power/Telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this item).
500.00 and capping/PVC pipe of minimum 25 mm size or higher as per requirement at site on the wall/floor etc., using bends, coupler and T joints and flexible pipe wherever necessary with fixture in the OFC room from equipment rack to common termination and from OFC room to SM room/ Reservation office / Data logger/FOIS room etc. (All required material for fixing to be arranged by the contractor)
100.00 3.65mm thick as per latest specification.
100.00 4.5mm thick as per latest specification.
100.00 4.8mm thick as per latest specification. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
2000.00 of 120/103 mm dia, 2 meter long in already dug cable trenches. The unit of RMT means two split pipes of 1 Mtr each Material shall be supplied as per latest specification RDSO/SPN/204/2011 Ver.1.1 or latest.
of (50/100/150mm dia) for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, the work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor].
of (50/100/150mm dia) for cable laying with offset at both ends and with couplings over Girder bridges by fixing on suitable MS Clamps at an interval of 2 Mtrs. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [MS angles, flats, bolts and nuts for manufacturing fixing clamps, bricks, sand, cement and all other miscellaneous required for the work shall be supplied by the Contractor].
of (50/100/150mm dia) for cable laying in Hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
6.00 High Density Polyethylene Duct (PLB-HDPE), 40/33 mm Dia, along with End Cap, End Plug, Cable Sealing Plug and Couplers, as per RDSO/SPN/TC/45/2013 Rev.2 with Amd 3.0 or latest
6.00 mm Dia, in the trenches and in the protective works already provided including in HDD portion and supply pulling of Nylone rope through it at different places as per direction of engineer incharge or site engineer
6.00 Duct, 40/33 mm Dia, as per latest specification.
6.00 PLB HDPE Duct, 40/33mm Dia, by using Blowing machine, providing the sufficient loops in loop/joint chambers and other associated works.
500.00 without damage of surface road/track using Auger Machine (HDD machine). The bore shall be upto 200 mm dia& shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different dia DWC-HDPE pipe/GI pipes coupling etc. as per direction of Engineer Incharge. Note:- Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
100.00 Mtr. for track crossing of cables, laying of DWC/HDPE/RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this item. (Supply of DWC/HDPE/RCC pipes with couplers/ collars is not included in this item). HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
100.00 Mtr. for road crossing of cables, laying of DWC/HDPE/RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this item. (Supply of DWC/HDPE/RCC pipes with couplers/ collars is not included in this item).
100.00 in parallel at a separation of 8 cms each to a depth of 150 mm and width will be as per site requirement in the platform surfaced/tiled floor for laying cable
200.00 DRG.No.SG/SWR/067 or latest guidelines. The lettering on the Cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site.
200.00 of size 300mmX300mm, casting of Concrete foundation of size 300mmX500mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing.
50.00 of 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor].
100.00 depth of 1M or as per site requirement, for identifying the existing cable path without damaging the working cables.
of Metre Existing/Already laid Signalling/Telecom cables to facilitate engineering construction works.
1000.00 insulated flexible 3-core multi strand 2.5 sqmm as per latest specification No.IS:694:1990 HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
2.00 strand copper conductor 10 Sq.mm (size of 140/0.3) Each coil length of 100 mts as per RDSO specification IRS.S 76/89 or latest.
100.00 conductor 16/02mm to ATC IS:694 to RDSO specification no.IRS.S76/89 Amendment.3 or latest. Each coil of 100 mts length. (Per Unit=Coil)
30.00 conductor 28/03 mm Each coil length of 100 mts as per RDSO spec No.IRS.S 76/89.
100.00 copper conductor PVC insulated colour coded twisted pair switch board telephone cables PVC sheathed with nylon rip size 0.5 mm of reputed make.
100.00 copper conductor PVC insulated colour coded twisted pair switch board telephone cables PVC sheathed with nylon rip size 0.5 mm Each coil length of 100 mts of reputed make.
500.00 hook up cable for data logger wiring: as per IRS Specification No IRS: S-76/89 or latest.
1220.00 latest specification.
1000.00 Screened Cable, cotton braided or reputed make, suitable for Speakers
4.00 size 880mm x 2 Meters made out of 50mmx50mmx6mm thick MS angle with stainless steel nuts and bolts for fixing of the rack with POWDER COATED and drilling suitable holes to suit hylam sheet and relay frames complete as per standard practice with tripod bases and reel insulators (for K rack, P rack and power rack) and with cable ladder of width 400mm and length of 2 Mtr. The thickness of angle to be 5mm. two angles of 40mmX40mmX5mm to be supplied at both ends and supporting flats of 25mm X5mm.
4.00 suitably concreting tri-pod bases and reel insulators with "J" bolts and nuts. Tripod and other supporting are to be painted in 2 coats with enamel.
2.00 box for terminating the conductor size of 0.2 to 2.5 sq mm as per RDSO Specification No/SPN/189/2004 Ver.3 which consists as per following, 2 conductor disconnecting terminal unfused type, end plate and din rail. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
150.00 of not less than 6mm thick and with an insulation to with stand 650V AC, on the floor of relay room etc at places as indicated by railway representative at site.
2.00 glass fronted box of size 300mm x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall be supplied by the Contractor].
1800.00 and power cables and internal wiring on terminal/ fuse blocks in cable termination Rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Hylam sheet 10 mm thick for terminal board, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves. After terminations are over, cable entry at the bottom shall be closed with, cement plastered, the inter- space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. Cable armour to be soldered to earth. (Supply of cable termination racks is not included in this item). [All bolts and nuts with washers, Hylam Sheet 10 mm Thick, cement, sand, stone jelly, Teak wood base, paints and all other miscellaneous materials required for the work shall be supplied by Contractor HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
50.00 ways terminal blocks and wiring of additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall be provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board. (Supply of relays, plug boards, connectors and retaining clips and 50 way terminal boards is not covered in this item).[Wire PVC 16/0.2mm copper, 2BA terminals, teakwood plank 25mm thick for fixing resistors and condensers, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneous materials required for the work shall be supplied by the Contractor].
30.00 existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. The work includes painting alterations and releasing the unwanted wires carefully without disturbing the existing wiring. [Wire PVC 16/0.2mm copper, soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required for the work shall be supplied by the Contractor].
10.00 Cable termination racks along with all the terminals, fuse blocks, relays, with jacks, holding clips etc., 50-way boards, terminals, connecting wires, cables etc., carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing, the floor shall be levelled and cement plastered.
1.00 panel including base plank, and other gadgets connected very carefully without causing any damage to the panel, accounting and stacking them neatly at a place as instructed by Railway representative at site. The resultant pit in the flooring shall be removed of all cable bits, levelled and cement plastered. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
50.00 inside the relay room as instructed, removing the relay pin along with the wire, neatly and carefully removing the wire duly testing with buzzer, re-bunching & placing with standard-grade nylon lacing twine and PVC dotted with buttons where required.
5.00 contractor and giving test to the railway incharge in Making a simulation test board plywood 3mm approximately size 1.5x1meter. Painted according to layout, fixing 1 way / 2-way switches in approximate position for track circuit, point setting lamp holders and lamps. Carrying out testing using simulation board after energising of internal circuit Commissioning of indoor and outdoor equipment as laid down in technical specification (Per Unit =Per Road)
150.00 Sun boards of various sizes of various drawings of Power diagram, Relay index chart, Station Rule Diagram, FTOT Particulars, yard layout diagram board etc, with different colours as per instructions of Site In-Charge/Railway Representative.
1.00 Crank Handle Cum Key Lock Relay Box (of MS Sheet) along with LEDs, with approved type push buttons, Wago or similar Disconnecting type Terminal Blocks including DIN rail etc., as per approved drawing. Installation, fixing and wiring of boxes for Key Lock Relays to be carried by Contractor's wiring and fixing material. The work shall be carried as per the instructions of site engineer.
100.00 conductor disconnecting terminal block for 2.5 sqmm wire termination make: wago/elmex or similar with accessories & taxes. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
1.00 10036207.00 Interlocking System (Centralized/Distributed) excluding Panel Processor (Hot Standby) with Signalling functions up to 125 functions as per function table enclosed along with 10% spares for the cards/modules/PCB, connectors/couplers, fuses, all relays, crimp contact, convertors etc. used, tools, manuals and Instruments as per RDSO specification RDSO/SPN /192/2019 ver. 2.0 or RDSO/SPN/ 203/2011 ver. 1.0 or latest. This includes supply of Maintenance VDU 55" 4K Resolution and Maintenance PC (embedded PC) and all types of indoor relays along with point contactor relays (QBCA1) required for points/other indoor purposes. Note: Payment will be made for only vital bit as per function table attached by Railways, no payment will be made for non-Vital bits such as Counter bits, SM key Bits, Read back bits and any potential free contact bits of DC-DC converter or Modem of El.
170.00 functions in El SYSTEM over and above 125 functions under item No 09_001 along with spares for the cards/modules/PCB, connectors/couplers, fuses, all relays, crimp contact, convertors etc. to the extent of 10% of item no. 090100& 090200.
1.00 Items for end location (Goomty) for Goomty/IBH/ station/IBH/Auto Hut for distributed Auto Hut Architecture in connection with item No. 1 as per Function table enclosed along with 5% Spares, tools, manuals & instruments as per technical specification. (Per Unit= Per Goomty/IBH/ Auto Hut)
2.00 application logic and interface circuit as per the SIP & Table of Control supplied by railway for the station. This includes internal FAT testing prior to submission for approval of circuits.
1.00 commissioning of EI equipments supplied for the station, duly carrying out the required FAT & SAT, including transportation from consignee depot to site at station. This also includes splicing & termination of OFC cable supplied by railways for communication equipment of EI. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
of operator VDU of size 55" 4K resolution, with backlit LED, with HDMI/DVI port, Inbuilt Speaker, required HDMI/DVI cables for connectivity and other miscellaneous item required for installation.
2.00 industrial grade computer (Similar to Moxa V2406A or better) with all accessories such as key board, mouse, antivirus etc. of industrial grade as per approved Specification as recommended by RDSO (TAN No. STS/TAN/3007 Version 1.0 or latest).
installation commissioning of Class-A protection with lighting event counter as per RDSO spec No. RDSO/SPN/197/2016 Ver1.0 and as per details given in technical specification. This shall include all the misc. material required for installation of the class A lightening arrestor which shall be installed at a height more than height of VHF antenna.
1.00 fixing of panel operator consol with arrangement to fix 55" VDU's - Reset boxes, and other S&T gadgets. This shall be made of not less than 18mm thick plywood or better materials with storage facility of approved colours with contractors' materials, lead, lift and manpower as per the instructions of engineer in charge and as per the enclosed drawing.
10.00 installation, commissioning, testing, trouble shooting and in diagnosing faults using diagnostic tools/flow charts including supply of necessary documents
of arrangement for Operator/Maintenance VDU and Embedded PC. This consists of a) 110V DC/110V AC, 500VA Inverter - 2 Nos b) 110V DC/24V DC, 10A - 2 Nos. Make: Similar to Gallant, Wago, Phoenix or better.
100.00 Relays, Plug-In-Type, style QN1, 8F/8B Contacts, DC Neutral line Relay, working voltage 24V DC, metal to carbon, with plug board, retaining clip and connectors as per RDSO Specification No BRS:930, IRS: S: 34 & IRS: S: 23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABCDF HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
100.00 Plug-In-Type style QNA1, 8F/8B Contact, DC Neutral line Relay, working voltage 24V DC, metal to carbon with plug board, retaining clip and connectors as per RDSO Specification No BRS:931A, IRS: S@58<44@ IRS:S:34 & IRS:S:23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABDGH
10.00 11F/4B contacts, magnetically latched, neutral line Relay, working voltage 24V DC, Metal to Carbon with Plug board, retaining clips and connectors as per RDSO Specification No. BRS 935/A, IRS:S 34-68 Amdt. 6, IRS:S 23-88 Amdt.1 as applicable. The interlocking code for this unit shall be ABDEG
20.00 plug in type style QBCA-1, 2HF/4B contacts, DC Biased contractor Relay, Tractive armature, working voltage 24V DC with Heavy duty front contact, Metal to carbon complete with plug board, retaining clips and connectors as per RDSO specification No. BRS 943, IRS. S@46"44@ IRS.S.23
10.00 plug in type, style QNA1K, 6F/6B contacts. DC neutral line Relay, working voltage 24V DC 1000 ohms, metal to carbon with plug board, retaining clip and connectors as per RDSO Specification No. BRS:931A & STs/E/Relays/UEA/PI dtd 30.05.97 Annex II & IRS:S- 23@44"38<44@ STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be CDEKY.
100.00 plug in type, Style QECX, 4F-4B Contacts, working voltage 110 V AC, metal to carbon for LED aspects with plug boards, connectors and retaining clips as per RDSO specification No: BRS:941A, STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amdt1, IRS S-23 & 34, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be ABDHK.
30.00 Units (120/60 sec), Working Voltage 24V DC with plug boards, connectors and retaining clips as per RDSO specification No. IRS:S- 61/2000, STR: SIQ 422 Ver1.0 or latest. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
10.00 (KLCR) working on24V DC, AC Immunized with different ward combinations and contact configuration 4F/4Bwith 2 extra ward plates and with case, RDSO spec no. RDSO/SPN/219/2016 ver 1.0 with amendment or latest, confirming to IRS S-23, S-34 & S@45<44@ IRS S:46.
2.00 and commissioning of Datalogger as per RDSO IRS/99/2006 or latest with Power supply arrangement for data logger consists of 12V,42AH VRLA batteries-4 Nos and 10A charger 1 No, EI interface card (Digital interface cards)/ protocol converter, for 512 digital inputs and 32 analog inputs. This includes supply of all miscellaneous items and software for commissioning of datalogger with E1 networking. (including PC/laptop, printer, mounting table and revolving chair of reputed make).
2.00 1520000.00 commissioning of SMPS based Integrated Power Supply (IPS) up to 4 Lines in RE area confirming to RDSO Specification No. RDSO/SPN/ 165/2023 (Ver. 4.0) or latest along with B & C Class SPDs,63 Amps fuse, status monitoring panel. IPS should be supplied with (55+5@61<41@ Nos. of uncharged LMLA Secondary Cells 2V- 200AH/2V-300AH(For RE section 2V/200AH for non RE section 2V/300AH) as one set for one IPS confirming to QA IRS:S-88/2004 Low Maintenance Lead Acid Stationary Secondary Cells For S&T Installations along with 16/25 Sqmm cable for each IPS set is (50 Mtrs Red + 50 Mtrs Black + 50 Mtrs Green) = 150 Mtrs. SPECIAL CONDITIONS:1.Including supply of all the accessories required for installation. The supplier shall take up installation, wiring, testing and commissioning with minimum one- month prior notice period from Railways. 2.All the required cables/ Miscellaneous items like wooden plank, ladder etc. for installation and commissioning shall be supplied as part of the work. 3.Supply, installation, testing and commissioning of SPDs (class B&C) are covered in scope of this work. 4. Contractor should make the power supply arrangements if any required for charging the supplied cells at site. contractor should arrange the industrial grade diluted H2SO4 for the charging of cells. The cells should be charged as per latest specification. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
2.00 Distribution Panel for IPS using Hylam sheet 10 mm as per site requirement and erecting it using MS angle clamp 65mm X 65mm X 8mm, HRC fuse block, Mains control switch, ammeter by-pass switch, voltmeter, ammeter, PBT terminals 60mm and wiring the same using wire PVC 7/1.40mm as per approved power diagram. This also includes termination of power cables using teakwood clamp of size 25mm X 60mm X 150mm on a base plank of 25mm thick 150mm width. (MS angles 65mm X 65mm X 8mm, Hylam sheet of 10 mm Thickness, as per site requirement, bolt and nuts required for manufacture of power panel, HRC fuses, box and carriers, teak wood clamp, wire 7/1.40mm, PVC casing and capping and all other miscellaneous materials will be supplied by the contractor, Supply of PBT terminals 60mm is not included in the item).
2.00 of IPS to power distribution panel. This includes transportation of IPS batteries from stores to the site, Erection of IPS panels on teakwood planks, interconnection between panels and wiring the IPS to power distribution panel using 10 sqmm multi-strand copper cable. The wiring should be done neatly using Aluminium ladder with phenolic sheet (Aluminium ladder, phenolic sheet of thickness 6 mm, teak wood plank of width 150 mm and thickness 25mm, 10 sqmm multi- strand copper cable and all other miscellaneous materials to be supplied by the contractor).
1.00 Supply Change over arrangement at SM room. CLS panel of size 800x500x275mm powder coated of MS sheet thickness 1.6mm as per RDSO specification: TI/SPC/PSI/CLS/0025 or latest HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
1.00 diesel generator set, 20 KVA, 230VAC, Single phase - similar to KIRLOSKAR make with CPCB type approved Acoustic enclosure as per the instructions of Railway representative at site. This work includes supply of control panel, exhaust pipe, changeover switch, phase selection switch and provision of interconnections between the DG set, control panel, changeover switch, phase selection switch, and painting. [Diesel generator set with CPCB approved acoustic enclosure, iron clad changeover switches 4 pole 3 position - 100 amps capacity, phase selection switch 4 pole, 2 position - 100 amps capacity, exhaust pipe, asbestos rope, wire PVC 7/1.4mm copper, PVC pipes and bends, clamps and all other miscellaneous materials required for the work shall be supplied by the Contractor].
1.00 set, including all lifts and leads (Lift arid lead shall be done using suitable hydraulic crane/Fork Lift. The contractor will be responsible for the safe transshipment of the DG set without causing any damages during transportation). The transportation of the DG set over a distance of 80 to 150kms.
1.00 foundations as per Drg No.SG/Proj/SK/DG/01/08 for installation of DG set as per the direction of Site In-charge Railway Representative and Carry out 1st service of the DG set as per the Manufacturer's instructions
1.00 battery stands available in the battery room along with connecting strips, wires and terminal boxes carefully without causing any damage to the batteries, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing any holes in the walls/ flooring shall be filled with cement mortar and plastered.
1.00 including equipment stands, terminal boards, power panel etc., in the power room carefully without causing any damage to the equipment's after disconnecting all the supply wires. The released equipment's shall be accounted and stacked at a place as instructed by Railway representative at site. After releasing any holes in the walls/ flooring shall be filled with cement mortar and plastered. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
1.00 capacity input voltage 160V AC - 280 V AC, output voltage 230V AC, Operating Freq 47-63 Hz with back up time 30 minutes (APC, Emerson or similar make).
100.00 Fuse holders 20 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
50.00 Fuse links 16 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
100.00 Fuse links 6 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
200.00 fuse links 2 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
1.00 plant (Aqua-Ion Model No. ACAMB 4 Bed Type).
0.50 1486809.00 Interface (UFSBI) complete and Block panel for Single line operation as per RDSO Spec. No. IRS:S- 105/2012 or latest (Per Unit=Set Per Block Section)
testing commissioning of UFSBI complete and Block panel for Single line/Double line operation as per RDSO Spec. No. IRS:S-105/2012. [All misc items required for commissioning shall be supplied by contractor] (Per Unit=Set Per Block Section)
of changeover of modems working on redundant channels for data transmission on OFC/Quad.
2.00 existing UFSBI system (for use with secondary/backup media i.e. 4-wire OFC VF Channel form station Primary mux or UFSBI E1 modem)
2.00 with UFSBI (as per IRS:S-104/2012)
2.00 with UFSBI (as perIRS:S-104/2012)
2.00 work with UFSBI (as per IRS:S- 104/2012)
2.00 UFSBI (as per-IRS:S-104/2012)
2.00 Converter type Power Supply to work with UFSBI (as per IRS:S- 104/2012)
Numbers HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
1.00 Block Counter of Size 550 mm (L) X 350 mm (W) X 850 mm (H) made of Powder Coated MS Sheet of 1.6 mm thickness and two doors fitted with double lock arrangement on front and back side including necessary cable entry arrangements on top and bottom as per the tentative drawing enclosed. Installation to be carried out using Teak Wood Base and necessary grouting as per the instructions of site engineer.
1.00 1276272.00 Solid State Block Proving by Axle Counter (Digital) [SSBPAC(D)] complete for Single line operation as per RDSO Spec. No. RDSO/SPN/175/2005Ver.1 or latest including Station Master's Block Panel, Wired Relay Racks with Relays, necessary Lightening & Surge Protection Devices for Power Lines 24V DC & Data Lines and Block Telephone as per RDSO/SPN/191/2005 or latest (Per Unit = Set Per Block Section)
Testing commissioning of SSBPAC(D) complete including Station Master's Block panel and Automatic Media Changeover Card for Single line operation as per RDSO Spec. No. RDSO/SPN/175/2005 Ver.1 or latest. [All misc items required for commissioning shall be supplied by contractor (Per Unit = Set Per Block Section)
of changeover Card for SSBPAC(D) which includes One Voice Modem Circuit and One E1 Converter Circuit, for working on redundant channels for data transmission on OFC/Quad. Necessary Lightning & Surge protection devices for data lines need to be provided.
1.00 Panel (Eft-688M)
card Numbers Module (Eft-533MS)
Numbers HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
2.00 counters as per the sketch 700mmx950mmx800mm with application of patty and good quality painting and shall have the provision to fix the PBT terminals boards and cable inlet holes at bottom (4 Places) and dummied. (Plywood sheet of thickness 25 mm x 25 mm x 6 mm, pad locks, tower bolts, Decolam Sheet for top, sheet guage for front slit door with tower top and bottom bolts, paints, patty shall be supplied by the contractor.)
of Instruments (all types), Block counters, batteries, block filter, block bell equipment etc., carefully without any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site.
4.00 height, 19" rack mountable, 4*E1 uplink, with 4 slots and supporting 8*EM (2W/4W), FXO/FXS and Ethernet card and one slot free for future expansion. Management supporting Telnet as well as NMS. Potential Free contact support. Uplink E1 supporting 4 direction paths as well as 1+1 protection. Unit supports DC (18-72VDC) as well as AC power. Make: MROTEK /CISCO/ MAPLE or similar.
8.00 Suitable to be accommodated in Integrated Multiplexer 1U height of MROTEK make or similar.
70.00 RDSO Drawing No.SG/SWR/057 and Earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, ASM room for block and control, and earthing of all equipment's in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS of flat 35mm X 6mm or 19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, river sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
of construct Unit maintenance free earth as per RDSO spec. No. RDSO/SPN/197 Ver.1.0 or latest. consisting of a) copper bonded steel electrode of 3.0m long, 17.0 mm dia with copper bonding thickness mini 250 micron and UL listed and marked--1 no. b) Earth enhancement compound of RDSO approved brand supplied in sealed bags of min 10 Kgs-03 No. c) Copper strip of 150X25x6mm to terminate earth rod-1 No. d) Copper strip of 300X25x6mm (MEEB)-1 No. e) Copper strip of 150X25x6mm (SEEB)-1 nos
30.00 Free Earth Pit as per RDSO specification No.RDSO/SPN/197 Ver.1.0 or latest and as per Technical Specification
of construct a Maintenance Free Ring Earth with Four Pits (For Interlocked Station, LC Gates/IB Signalling Application) for achieving less than one Ohm as per as per RDSO Spec No. RDSO/SPN/197 Ver.1.0 or latest consisting of a) copper bonded steel electrode of 3.0m long, 17.0 mm dia with copper bonding thickness mini 250 micron and UL listed and marked--4 no. b)Earth enhancement compound of RDSO approved brand supplied in sealed bags of min 10 Kgs-12 No. c) Copper strip of 150X25x6mm to terminate earth rod-4 No. d) Copper strip of 300X25x6mm (MEEB)-4 No. e) Copper strip of 150X25x6mm (SEEB)-4 no's
2.00 Ring Earth with Four Pits (For Interlocked LC Gates/IB Signalling Application) as per RDSO specification No. RDSO/SPN/197 Ver.1.0 or latest and as per Technical Specification.
150.00 Single Core PVC insulated Copper Cable as per IS: 694 for connecting Main Earth Electrode to MEEB in equipment room. Color: Green.
150.00 Single Core PVC insulated Copper Cable as per IS: 694 for connecting MEEB to SEEB and SPDs to MEEB. Color: Green.
150.00 Single Core PVC insulated Copper Cable as per IS: 694 for connecting SEEB to all equipment's. Color: Green. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
150.00 Cu cable for connecting main earth electrode to equipment room (routing through GI pipe/DWC/HDPE/PVC conduit pipe of suitable size as per site requirement
300.00 sqmm Cu cable between BRC and racks. The work includes mechanical connection by providing two Cu lugs and two steel screws, drilling to two holes and removal of powder coating on rack body, thimbles ties, etc. and routing the same as per site requirements.
100.00 interconnecting earth electrodes.
100.00 interconnecting earth electrodes.
2.00 arrester of class B and C suitable for single phase supply in TT network as per RDSO spec.no. RDSO/Spn/165/2023 ver 4.0 amd.1 or latest.
2.00 Class B and C arresters as supplied. These din rail mountable devices along with 63 amps HRC input fuse and fuse base shall be fixed in a wall mountable cabinet of size 450 x 250x150 mm made as MS steel of 20 gauge or better with IP31 protection and power coating. All the internal power wiring shall be made by using 10sq.mm cu cable. the PF contract of the class C arrestor shall also be wired using cable thickness of 2,5 sq.mm and terminated on a suitable terminal block.
2.00 12 channel (4 Channels110V AC, 2 Channels- 110V DC, 6 Channels- 24V DC) as per RDSO Spec./256/2002 or latest with 6- digit counter.
2.00 of Earth Leakage Detector 8/12/16 channel.
25.00 commissioning of Heat and smoke multi sensor as per RDSO/SPN/217/2025 ver-3.1 or latest. along with its base, back-box and all accessories incompliance with IS:2175 and IS:11360 standard sand Under writers Laboratory (UL) listed.
200.00 commissioning of Analogue linear heat sensing (LHS) cable as per RDSO/SPN/217/2025 ver-3.1 or latest HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
2.00 commissioning of linear heat sensing interface Module as per RDSO/SPN/217/2025 ver-3.1 or latest in compliance with IS standards and Underwriters Laboratory (UL) listed.
300.00 sq.mm unarmoured as per RDSO/SPN/217/2025 ver-3.1 or latest
1.00 commissioning of Networkable single loop addressable Fire alarm Control panel expandable upto 4 loops with GSM interface as per RDSO/SPN/217/2025 ver-3.1 or latest. This work involves supply, fixing, installation and testing of control panel. The control panel shall be networkable to Zonal /Divisional headquarters preferably over TCP/lP and shall have clock synchronization facility. This includes Networking module (TCP/IP) for control panel along with power supply unit and battery set of required capacity for 24 hours backup as per RDSO specification. The panel should support degrade mode operation in compliance with IS: 2189, EN54 standards and Underwriters Laboratory (UL) listed.
2.00 commissioning of GSM module for Control panel with backbox and all other accessories as per RDSO/SPN/217/2025ver-3.1 or latest. with auto dialer function to SMS during failure or fire situation.
1.00 commissioning of Manual call point (resettable) with backbox and all other accessories as per RDSO/SPN/217/2025ver-3.1 or latest
1.00 commissioning of Relay module with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest
2.00 commissioning of Hooter and Visual strobe alarm units with backbox and all other accessories as per RDSO/SPN/217/2025 ver-.3.1 or latest along with its power supply unit.
2.00 commissioning of Control module with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
1.00 commissioning of Monitor module for 3rd party with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest
1500.00 cables on PVC pipe / capping casing, or cable trays, ladder, shelter etc. as instructed by Railway engineer at site. (Indoor cables to be drawn through pipe, outdoor cables if required to be clamped on wall /floor etc.
6.00 installation, testing and commissioning of CO2 fire extinguisher 6.5 kg capacity conforming to IS15683 with ISI mark provided with all fittings and accessories.
2.00 detector. Highly sensitive smoke aspiration system for monitoring of rooms and equipment for earliest possible fire detection For Relay rooms as per RDSO spec No.RDSO/SPN/217/2025 ver3.1or latest.
2.00 Sampling CPVC Pipes with all required accessories for the Aspiration System. (Per Unit = Per Relay Room)
Programming, Numbers Installation, Testing and Commissioning of Aspiration Smoke detection Supplied.
1.00 1092166.00 Section Digital Axle Counter (HA- SSDAC) with Dual Track sensor Devices as per RDSO specification No. RDSO/ SPN/ 177/ 2012 version 3.0 or latest (Phase reversal type) as per details given below) Configuration 2DP-1 section b) length of cable required with each track devices -15 mtrs.
testing commissioning of High Availability HASSDAC to be installed, wired, tested and commissioned by OEM as per the guidelines issued by RDSO wiring discipline should be as per RDSO TAN No. STS/ E/TAN/ 6001 Version 1.0 or latest. The pre- commissioning check list issued by RDSO for HASSDAC to be prepared by OEM and jointly signed by OEM & railway before commissioning of HASSDAC. OEM should submit site installation certificate. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
1.00 Section Digital Axle Counter as per latest specification No.RDSO/SPN/177/2012 (Version - 3) or latest, consisting of :- (i) Portable Data Analyser (Downloading Event Logger Data for analysis and report generation) - 1 No. (ii) Pure Sine Wave Digital Multi-meter Fluke Make (Model- 1871) or Rishab Make (Model-18S) - 1 No. (iii) Extender Card - 1 No.(iv) Dummy Wheel - 1 No. (v) Ring Spanner (17-19, 24-26) - 1 No. each (vi) Open End Spanner (17-19, 24- 26) - 1 No. each (vii) Socket Spanner with Handle - 1 No. (viii) Torque Wrench (Jaicom JPR or equivalent 88 NM_ - 1 No. (ix) Screw Driver No. 902 or as directed by Engineer-in- Charge - 1 No. (x) Screw Driver No. 935 or as directed by Engineer-in - Charge - 1 No. (xi) Marking Jig for Drilling - 1 No. (xii) Dummy Load to check Power Supply (Resistive) - 1 No. and any other additional specialized Tools suggested by RDSO Approved OEM required for Trouble Shooting and Maintenance of Equipment.
36.00 (MSDAC): Supply, Design, Detection Installation, Testing and Point (DP) Commissioning of Multi Section Digital Axle Counter (MSDAC) complete system as per RDSO Specification No. RDSO/SPN/176/2013 version.3 with latest amendments STR No. SIQ 0001 Ver.2.0 or latest. MSDAC Reset procedure shall be as per SWR MSDAC Reset policy. Tenderer shall design the scheme for provision of required number of evaluators, reset equipment's, trackside junction boxes, detection points and track clearance relays etc and shall be submitted along with the offer. Remote Diagnostic System shall be provided at station. Length of the cable required for each DP and Rail Type will be specified at the time of issuing call Letter. [This also includes supply of 10% all types of spare cards, LV Boxes, Wheel sensors and other essential modules as specified in RDSO Spec, it shall be rounded to nearest integer subjected minimum of one item. One set of Specialized Tool and Measuring equipment's as per RDSO specifications shall be supplied. (Per Detection Point = DP)
1.00 and maintenance of MSDAC consisting of torque wrench, ratchet, testing plate, measuring tape, screw driver, and gloves and multi meter fluke115 HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
1.00 field equipment (transmitters coils 2 No. receiver coils 2 No.) on the rails at the entry/exit track circuits without causing any damage. Excavating the under the track for removing track devices, connecting cables and duly covering the cable duct. Disconnecting and removing of Amplifier (electronic junction box and other associated equipment from the location box and transporting to a central location for accountal. Design of SIP in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re- submission for approval after incorporating the changes as required by Railways. After carrying out changes, three Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy.
Set Design of SWRD in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Railways. After carrying out changes, three Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy.
Set HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
100.00 based on the approved Signalling Plan as per RDSO Sig DATE Format. AutoCAD in A3 size. Initially, Contractor shall submit 2 set of documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by railways. The TOC & Preliminary Check and Certification to be done by the IRSE or IRSTE (license holder). After carrying out necessary changes, two set of 'Hardcopies' are submitted for administrative approval. The final corrected drawings shall be supplied to Railways on 80/90 GSM Tracing film and 2 copies of blue print properly bonded booklets and the soft copy in USB Pen drive.
2.00 & approval of Interface Circuits by IRSE/IRSTELO License holders for stations having up-to 25 routes.
2.00 & approval of Logic Circuits of stations of up-to 25 routes by IRSE/ IRSTELO License holders.
95.00 verifying and approval of Interface Circuits / Logic circuits having more than 25 routes by IRSE/ IRSTELO License holders. (Per Unit = Per Route Per Station ) HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
2.00 Cable Core Plan, Cable Termination Rack Particulars, Location Box Particulars, Power Supply Diagram, Track Circuit Bonding Diagram and/or any other drawing on Auto- CAD in A2/A3/ A4, etc. size (as per instructions of Engineer in-charge). Initially Contractor shall submit 2 sets of 'AS PLANNED' documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or fore-submission for approval after incorporating the changes as required by railways. After preliminary approval, execution of work shall be carried out at site. After Completion of work, 2 sets of AS MADE Check Prints are submitted for administrative approval. Railways will return one set to the contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respect along with its soft copies in USB Pen Drive and 6 sets of final completion drawings in properly bound booklets. [For Centralized Electronic Interlocking Stations/Small Stations] HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
30.00 'Asmades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back-to-back in one plastic cover) and handed over to Railways. Also, the contractor has to supply one set of As made in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incorporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. On approval 8 copies shall be made for As- made circuit diagrams also as mentioned above. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
100.00 following Registers with latest proforma given by in-charge officer each register of 100 pages. Station Asset Register/Deficiencies Book/Officer Inspection book/ Work site orientation classes note book /Station Message book/Infringement measure book fog signal gears/Route cancellation register/Relay room Key register/Cable testing summary/Signal maintenance record register/Power Systems Battery maintenance Register/Mechanical Signalling Register/Axle Counter Maintenance Register/Block instrument Maintenance Register/Track circuit maintenance Register/Lifting barriers maintenance Register/Electrically operated point maintenance Register/Electronic interlocking Maintenance Register/Location box maintenance Register/Earth Testing record Register/Relay room register/Joint Inspection of Points and Crossings register/Block Proving Axle Counter Register/Diesel generator /SoIar panel Register (Per Unit = Per Register)
1.00 meter Current measurement upto 200A AC/DC True RMS measurement for AC voltage & current. (Large jaw of size of 18mm) Model: FLUKE 362/Rishabh or higher as per specification.
of consisting of 1. 3/8" sq Dr Socket 6mm, 2. 1/2"sq Dr Socket 8mm 3. 1/2"sq Dr Socket 18mm, 4. 1/2"sq Dr Socket 19mm 5. 1/2"sq Dr Socket 20mm, 6. 1/2"sq Dr Socket 22mm 7. SP Spanners 10mm, 8. SP Spanners 12mm 9. adjustable Wrench 8" 10. adjustable Wrench 12" 11. 3/8" Sq Dr Ratchet handle 12. 1/2" Sq Dr Ratchet handle 13. T handle 1/2" 14. Short Extension Rod 1/2" 15. Stanley make Water-Proof Medium Nylon Tool Bag 16. Electricians TRMS digital multimeter FLUKE-117 17. MECO Clamp meter 3690 AC/DC 600A 18. Dummy Wheel-1 No Best Indian make electrical hand gloves suitable for 1000V. Make: Friedrich Germany, INSULA or similar.
12.00 unskilled staff round the clock to attend to teething trouble of the installation along with SSE/JE(Sig) after the installation has been brought into commissioning. The work includes routine maintenance, failure restoration as per the direction of the SSE/JE(Sig). HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
360.00 man power to carry out miscellaneous/sundry works in the office/field between 08.00 hrs and 20.00 hrs of the day and accompanying Railway staff with all expenses of transportation, accommodation, food, consumables etc., with all ascents/descents, taxes, octroi, cess, fess, duties, with contractors tools and plants, materials, consumables, labour, crew, machineries with all lead and lift etc., complete as per special conditions, specification, regulation and as directed by Railway Engineer-in-charge.
360.00 the clock in 12 hours shift beat from Up Home Signal to Down Home Signal to avoid theft of signalling assets. {Per Unit- Per 12 Hours shift}
1.00 panel with WAGO/ Pheonix/Elmex make or similar disconnecting Terminals blocks of size1500mm x 500mm x 200mm thickness 1.6mm (16 SWG) 150 numbers of disconnecting terminal block with accessories. (The box should be divided in to two compartments 500 mm from TOP with door arrangement including locking, and bottom 1000mm closed fully with screws WAGO/Pheonix/Elmex terminals suitable for cable dimensions maximum of 2.5 sq.mm. Provision of easy and ensuring aesthetics.
1.00 Panel' and termination of cables on Wago/krone connectors as per the instructions of the site Engineer.
4.00 Disconnecting terminals of Wago/Pheonix/Elmex make or similar.
4.00 disconnecting terminals of Wago/Phoenix//Elmex make or similar
2.00 Disconnecting terminals of Wago/Pheonix/Elmex make or similar
2.00 disconnecting terminals of wago/phonix/elmex make or similar and termination of cable at the station/LC gates etc. This includes fixing of Quad/PIJF cables and CT box on the wall.
10.00 conforming to RDSO specification No.IRS-TC 77/2012 Rev 3.0 or latest for quad cable. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
10.00 Shrinkable type complete for 6 quad cables. After the jointing the through cable has to be tested for insulation resistance and loop resistance in presents of Railway Engineer and in case of any defects the jointing has to be done at free of cost by the contractor. [Heat Shrinkable jointing kit conforming to RDSO specification No.IRS-TC 77/2012 Rev 3.0 covered in the supply portion has to be used for this purpose.] The Contractor should supply all other small items free of cost which are required for making a joint. Only gas blower to be used for blowing
2.00 damaging the fiber and provision of joint chamber of 1.2 mtr dia, 60 Cm height and 50 mm thickness with two-piece top cover and bottom cover. with holes for drainage and cable entry (The reinforcement drawing enclosed). This includes backfilling and ramming of the trench after placing the joint closure and cable loop in the chamber without causing any damage to the same and consolidation of soil as well as disposal of soil as per plan and as advised by RailTel Representative.
2.00 RCC joint chambers with dry sand mixed with ant termite chemical as required in specification up to 400mm height and the cover is refixed in position.
& Section/Derivation OFC Joint enclosure including Splicing (24 Fibre) inside already prepared jointing pit. This does not include provision of Joint chamber, top plate & back filling. The joint Enclosure shall be as recommended in the technical specification
4.00 cable inside service building by providing large G.I. Band at Bottom & vertical G.I Pipe of 75 mm dia. The vertical pipe shall be 75mm above the floor level & the mouth of the pipe shall be covered by Plastic Cap. The floor shall be restored to the original condition.
50.00 470:1120 ohms or 470:600 ohms or 470:470 ohms as per RDSO spec No. IRS-TC-76-2021 or latest. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
1.00 accessories, surge protection arrangement, FDF, racks, DDF, runway ladder etc. this includes connecting all pig tails and optical patch cards etc. to SDH and primary mux equipment with all interface cards to 48V bus including supply of wires and connectors, terminations of all E1s on DDF, termination of VF interface circuits to krone type MDF at both ends including taking PVC cable over runway or a wall, krone type DP with all surge and lighting protection complete for all the circuits derived from PD mux. This work includes wiring and connection of telephones in SM's room and extension of generator supply equipment. All miscellaneous materials like power wires conduit and accessories etc. shall be supplied by the contractor. Suitable link panel should be provided on this rack for testing and isolation of fault.
1.00 charger 230V AC 50Hz input and 48V DC/25 Amps output in (2+1 configuration) suitable for VRLA battery as per RDSO specs: RDSO/SPN/TL/23/99 ver.4 or latest.
and 48V,200AH VRLA battery bank as per latest specification No.IRS- S93/96A [One set battery bank contains 24 nos of 2v/200AH cells].
1.00 Rack complete with fittings for housing LER, LSR, SDH equipment, FDMS, DDF and other equipment like cable managers, completely wired using krone module and other equipment's like runaway ladders etc., as per technical specification below. It should be able to lock all the equipment with only order wire telephone outside the rack, the rack should of APW President/ Rittal make etc., The components of the rack are specified below. this includes transportation and installation of rack in prefab/building at specified stations. a. Rack S33 42U 600WX600D -1 no. b. fixed side panels 42U x 600 D - 2nos. c. Front glass door plain 2U/600W -1 no. d. Rear MS door plain 42 U/600W-1 no. e. Caster with brakes- 2nos. f. Fans directly mounted on the top 48v Dc 90CFM - 2NOS. g. Krone mounting bracket -01 No. h. MCB mounting panel with MCBS a)32 Amps MCBs (DP) - 2 nos. b) 6 Amps MCBs (DP) - 6 nos. i. Earth continuity kit -o1 nos j. Equipment trays-5 nos. k. channel with cable loops 42U-2 Nos HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
2.00 testing of Rack/Wall mountable FDMS and termination IN and OUT 24 fiber OFC cables (with all connecting materials) routing/dressing fiber as per direction of engineer/In charge. this work includes termination/splicing of fibers and testing of fibers in the section/block and report of fiber to be submitted in hard and soft copy.
100.00 for STP/UTP cable
2.00 station control telephone conforming to spec., No.IRS.TC82/2005 or latest
1.00 control telephone (4Wire/2Wire) as per RDSO specification IRS: TC- 78/2020 Ver. 1.1 or latest.
1.00 Way station equipment DTMF and control telephones. The work involves fixing the released way station equipment on the wall at an appropriate place in consultation with Railway representative at site, wiring and interconnecting the same with test panel, control telephones and batteries. (Supply of way station equipment, control telephones and batteries is not included in this item). [Wire PVC 3/0.75mm & 16/0.2mm copper, MS clamps for fixing arrangements, PVC tubes 25mm dia for interconnections and all other miscellaneous items required for the work shall be supplied by the Contractor].
5.00 Beetel or simlar.
2.00 modules & mount assembly wall mounting type powder coated with surge and lighting arrester and locking facility.
testing commissioning 0f 100 pair krone connector box, fitting the same wall as directed by Railway Representative
10.00 of FRP type, conforming to specification RDSO/SPN/TC/44/2002 Ver. 3.0 or latest.
10.00 RDSO Spec. No. IRS/TC/42/20 Ver. 1.0 with latest HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
of communication along the railway track. Fabrication of emergency post as per RDSO Drawing No. UBL/SG/CON/6/2004 and fixing of emergency socket post and burying the post to a depth of 1m after entry of cable. The post to be painted with red oxide before installation. This includes termination of derivation cables on termination strip inside the emergency socket, painting of emergency socket post with alternate black and white strips of 6'' width. The paint used should be of standard quality and two coats of paints should be applied. The EMC post should be painted with red oxide base before painting. (rails will be supplied by railways for the fabrication of emergency post)
1500.00 cable through PVC pipe/ Casing capping fixed on the walls, as directed by site InCharge. This work includes termination of cables in the krone connector and fixing of IPM and extending earthing to krone box
1.00 25 Watts synthesized configuration VM-04 of bandwidth 136-174 MHz with DTMF microphone, of Motorola make model GM338/XiRM- 3688 or kenwood TK7360 as per latest specification
testing commissioning of 25 Watt VHF set with GP antenna and antenna cable of length 30 M, power supply and battery of 12V 65AH. This includes supply and fixing of GI pipe of suitable dia to the required height as per the guidance of the field engineer, wiring of antenna cable through PVC conduit. All the materials required for installation to be supplied by the contractor. VHF equipment, SMPS power supply, Antenna &antenna cable will be supplied by the Railways.
Jim Numbers antenna for 25-Watt VHF set
1.00 RG 217U with silver tipped connectors on both ends, 30 meters length
2.00 Boost mode Power supply unit of 12V/15Amps. for HF/VHF/UHF Transceiver.
2.00 Battery 12v/100ah Similar to Amar Raja make or better. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
1.00 office clock with GPS synchronization (stand-alone mode) as per RDSOSpec.No. RDSO/SPN/TC@47>47@2008 Rev 4.1 or latest with RED LED with complete installation including all necessary accessories as directed by Railway Site Engineer.
2.00 Sided Clock with GPS synchronization as per RDSO Specification No RDSO/SPN/TC / 62 /2008 Rev 4.1 or latest. Including all the accessories required for the installations.
1.00 core i713th Gen with windows 11 pro (16GB) Make: Dell or equivalent as per latest technical specification
8.00 cards 5 Mtrs length as per site requirements. (LS-SC, SC-SC, LC-LC, FC-FC patch cards as per site requirement)
of materials by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. Transportation more than 100 Kms.
3.00 (Model: Godrej Store well/slimline 4S)
of Numbers Office/executive/computer support Revolving Chairs (Bravo high back and Cushioned) of Godrej or reputed firm for seating arrangement
4.00 plank with thickness of 18mm, teakwood beading with three draws of size 4' X 2' with heavy duty S type chair with hand rest. The above is of Godrej or similar make
10.00 or better with 2 keys.
2.00 made of BATHLA make or better of App 5 feet height
10.00 Aluminium ladder of size 25 X 25 X 5mm, 200mm width, arrangements for drawing various wires in the battery, equipment and relay rooms. Total 94809133.50
Item Breakup - SB-S&T NS Items
Supply of Final AS MADE documents Set of Obalapurma stations. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supply, Installation, Testing and Numbers Commissioning of Isolated DC-AC Inverter of 1KVA or higher. Input 48 V DC, Output:220V AC, with all required Protection Circuits.
Supply of CAT 6 UTP Patch Cord-2 Numbers meters [Detailed Specification in Technical Document]
Supply and Termination of 12 Fiber Numbers 12 SC Type Rack Mountable FDMS loaded withSC '0' DB & Adaptor SC SM Pigtail 1.5 meters with all the accessories required for installation[Detailed Specification in Technical Document]
Description:- Supply and Fixing of Metre PVC Trunking o f 5 0 X5 0 m m with cover of 2mm thick and 2mtrlength each. (This includes all materials like clamps, bends, couplers, fixing required forlaying). Inspection Consignee
"Supply and installation of Layer 2 Numbers Switch as per RDSO/SPN/TC/65/2021, Rev.6.0 orlatest. I'ninimum 8+2 Port Manageable with 8 Nos 10/100/1000 Mbps Ethernet port, POE+ & Single Fiber 2 Nos 1G SFP Port with BX SM SFP Optical Modules loaded including mounting kit and all the accessories. Inspection RDSO"
Supply and installation of SIP Based Numbers Basic IP Phone with 128x64 Pixel Graphical LCD as per Specification.
Supply & installation of Audio Numbers Amplifier of Make: AHUJA Model: SSA-250DP or similar, workable on 230V AC/12VDC supply with protection.
Cutting grooves on walls / floor for Metre fi x i n g PVC pipes 50mm d i a and d r a w i n g t h e c a b l e t h r o u g h it resurfacing to original conditions
Installation, Testing of LER & LSR IP MPLS Routers,switches,IP Phones,Gateways etc including supply & Installation of all the accessories like , Earthing Cable,Optical Patch Cords of 3 mtr- 4 Nos for LER & 8 Nos for LSR s, Cat 6 Patch Cords of 1 mtr -4 Nos ,one 6A MCB for each LSR and LSR ,wiring etc. as required for Routers
Releasing and Shifting of Telecom Lumpsum items like Routers,STM,PD Mux,VHF,Passenger amenties & VSS etc as per instruction of Work incharge
Supply and fixing of perforated Numbers cable tray 1.6mm x 250mm x 60 mm size with 3 Metres length each with all accessories like support Brackets, angles,bends and coupling etc for fixing as per site condition. Make OBO or similar equivalent or higher version HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
Supply of PVC Pipe 25mm dia, Metre round conduit as per Indian standard of reputed make confirming to IS:9537 (part) - 1983 (reaffirmed 2007) or latest
Fixing of PVC pipe or casing & Metre capping, using bends, couplers, T- joints & flexible pipe wherever necessary with fixtures. (All required materials for fixing like clamps, bends, couplers, T-joints & flexible pipe, etc are to be borne by the contractor
Supply and installation of 6U Mount Numbers Rack with one Number powers tip of 4 sockets, one Fan and required fixures for mounting rack and equipments
S u p p l y o f p o w e r s u p p l y u n i t for Numbers universal DTMF way station control p h o n e c o n f o r m i n g to spec.No.IRS:TC-72/97 Amdt 1 or latest with 12V/7AH MF battery.
"Disconnecting/shifting, Installation, Numbers configuration of Rack (42U/9U/6U/IPIS) along with PC, Switches, servers, TV etc including all the accessories required for installation"
"Releasing of PDCH / IP based Numbers Camera (CCTV)/ CGDB/ Speakers / GPS clocks handing over the released materials like cables etc to the section superviosor" Total 997362.00
Item Breakup - TA-TRD SOR Items
6.a Supply (excluding copper wires Kilometre &SPS) of over head equipment only
6.a Erection including copper wires Kilometre &SPS of over head equipment only manual
3.a.ii Supply only for fabricated MT mast K,B, S series etc.
3.b.i Supply of fabricated steel work MT other than masts
3.b.i Erection of fabricated steel MT work other than masts by manual
3.c Supply work(SPS).
3.c Erection work(SPS).
2.a.i For Foundation and Plinth - cum Concrete in hard soil
2.a.ii Concrete in rocky soil
2.b Concrete in other than hard soil cum and rock
1.a Preparation of designs and Track drawings for over head equipment Kilometre and verification of Purchasers Engineering Plan.
1.c preparation of station working Each rule diagram and working instruction HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
3.a.i Erection of traction masts and MT main masts of switching stations, booster stations and L.T supply Transformer stations by manual
3.e Supply of a Guy rod assembly
3.e Erection of a Guy rod assembly
4.ai.a Supply of a single bracket Each assembly
4.ai.a Erection of a single bracket Each assembly
5.a.i arrangements for span wire
5.a.i arrangements for span wire
5.ii Supply of a span wire
5.ii Erection of a span wire
8.a.v equipment(3 pulley type) with counter-weight assembly for conventional OHE.
8 . a . v Erection equipment(3 pulley type) with counter-weight assembly for conventional/composite OHE.
8.b.i Supply of materials for Each termination of Single conductor of overhead equipment or terminating wire.
8.b.i Erection of materials for Each termination of Single conductor of overhead equipment or terminating wire.
8.b.ii Supply of materials for Each termination of Double over head equipment conductor
8.b.ii Erection of materials for Each termination of Double over head equipment conductor
9.a Supply of anticreep galvanised steel wire
9 . a E r e c t i o n of anticreep galvanised steel wire
10.a Extra on item 6(a) for supply of Each additional fittings at a turnout, diamond crosssing or overlap.
10.a Extra on item 6(a) for supply of Each additional fittings at a turnout, diamond crosssing or overlap.
11.a.i Supply of a composite cut Each insulator
11.a.i erection of a composite cut Each insulator
11.b Supply of 25kV Post insulator
11.b erection of 25kV Post insulator Each
12.a.i Supply of a section insulator Each assembly
12.a.i Erection of a section insulator Each assembly
13.a.i Supply of a 25kV single pole Each isolator without earth contact assembly.
13.a.i Erection of a 25kV single pole Each isolator without earth contact assembly. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
13.d Extra for supply of an earth Each contact assembly in an isolator
13.d Erection of an earth contact Each assembly in an isolator
15.a Supply of a copper jumper
15.a Erection of a copper jumper
16.a Supply of a structure bond
16.a Erection of a structure bond
16.b Supply of longitudinal bond
16.b Erection of longitudinal bond
16.c Supply special bond
1 6 . c Erection of transverse and Each special bond
17.a Supply electrode
1 7 . a erection of a single earth Each electrode
31.a equipment -Transfer of equipment from one mast or support to another
31.d equipment - Dismantling of overhead equipment
31.f Splicing and extension of an Each anchhored over head equipment
31.g equipment - Dismantlinng of a section insulator
31.i equipment - Dismantling of an issolator
31.k equipment - Dismantlement of OHE mast/structure by cuttinng
31.o equipment - Erection of Temp, mast includinng cantilever assembly transfer of OHE to New mast and releasing the temp mast under power/non power block
31.p equipment - Releasing of portal Boom under power/non power block Total 24402571.40 Item- 17 TRD SOR POWER BLOCK S No. Item No Description of Item Unit Qty Rate Amount
6.a Erection including copper wires Kilometre &SPS of over head equipment only manual
3.b.i Erection of fabricated steel MT work other than masts by manual
3.c Erection work(SPS).
4.ai.a Erection of a single bracket Each assembly
5.a.i arrangements for span wire
8.b.i Erection of materials for Each termination of Single conductor of overhead equipment or terminating wire. HUBLI DIVISION-GATI SHAKTI/SOUTH WESTERN RLY
10.a Extra on item 6(a) for supply of Each additional fittings at a turnout, diamond crosssing or overlap.
12.a.i Erection of a section insulator Each assembly
31.a equipment -Transfer of equipment from one mast or support to another
31.d equipment - Dismantling of overhead equipment
31.f Splicing and extension of an Each anchhored over head equipment
31.k equipment - Dismantlement of OHE mast/structure by cuttinng Total 990357.70
Item Breakup - TB-TRD Non SOR Items
Loading/Unloading and handing over of all type of materials etc. other than contractor material
Hiring of 15T Crane Total 735152.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IRGCC2022.pdf
ATTACHMENT
GCCACS-1.pdf
ATTACHMENT
GCCACS-2.pdf
ATTACHMENT
GCCACS-3.pdf
ATTACHMENT
GCCACS-4.pdf
ATTACHMENT
GCCACS-5.pdf
ATTACHMENT
GCCACS-6.pdf
ATTACHMENT
GCCACS-7.pdf
ATTACHMENT
GCCACS-8.pdf
ATTACHMENT
GCCACS-9.pdf
ATTACHMENT
GCCACS-10.pdf
ATTACHMENT
GCCACS-11.pdf
ATTACHMENT
SCCGS2024v3.pdf
ATTACHMENT
Safety.pdf
ATTACHMENT
JPOforcablecut.pdf
ATTACHMENT
WebLinkforTechSpecUSSR_DSR.pdf
ATTACHMENT
TSTELE.pdf
ATTACHMENT
TSSIGANAL.pdf
ATTACHMENT
TechnicalSpecificationElectricalGeneralV2.pdf Technical Specification Electrical
ATTACHMENT
TechnicalSpecificationElectricalGeneralV2.pdf
ATTACHMENT
TSELETRACTION.pdf
ATTACHMENT
ST-26-GSU-UBL.pdf
ATTACHMENT
TenderformsOBM.pdf
ATTACHMENT
GADOBMStn.pdf
ATTACHMENT
ESPOBMphII.pdf
ATTACHMENT
ApendixtoTenderOBMR.pdf
ATTACHMENT
Download all tender documents and submit your bid