| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAdmitted-Finance | ₹4.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.3 Cr+₹14.1 L (3.37%)Admitted-Finance | ₹4.3 Cr+₹14.1 L (3.37%) | L2 | Admitted-Finance |
| 3 | L3₹4.4 Cr+₹22.5 L (5.36%)Admitted-Finance 2 1433 D 6 KAMAL COLONY SAHARANPUR UP PIN 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | ₹4.4 Cr+₹22.5 L (5.36%) | L3 | Admitted-Finance |
| 4 | L4₹4.7 Cr+₹53.5 L (12.7%)Admitted-Finance | ₹4.7 Cr+₹53.5 L (12.7%) | L4 | Admitted-Finance |
| 5 | L5₹5.2 Cr+₹95.7 L (22.8%)Admitted-Finance 248 1 CHHEDIPURWA STATION ROAD BEHIND GURU NANAK SCHOOL GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | ₹5.2 Cr+₹95.7 L (22.8%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | S.T.Electricals Pvt Ltd L4 | AMIT ENGINEERING CORPORATION L2 | M/S SMM INFRATECH PVT Ltd L5 | M/S Sushil Kumar L3 | M/S AARADHYA AND ADHYATM ASSOCIATES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00Supply Work | ||||||||
| 1.01 | ACSR DOG CONDUCTOR | 11 | KM | 1,20,000 ₹13,20,000 | 1,09,000 ₹11,99,000 | 1,20,000 ₹13,20,000 | 96,100 ₹10,57,100 Lowest | 1,00,000 ₹11,00,000 |
| 1.02 | 33KV 3X300 SQ MM XLPE CABLE | 12,000 | Mtr | 2,675 ₹3,21,00,000 | 2,450 ₹2,94,00,000 | 2,600 ₹3,12,00,000 | 2,480 ₹2,97,60,000 | 2,400 ₹2,88,00,000 Lowest |
| 1.03 | HDPE PIPE 160 MM Dia. | 50 | Mtr | 600 ₹30,000 Lowest | 650 ₹32,500 | 1,650 ₹82,500 | 950 ₹47,500 | 1,500 ₹75,000 |
| 1.04 | GI Pipe 200 MM Dia | 28 | Mtr | 1,900 ₹53,200 | 2,250 ₹63,000 | 1,650 ₹46,200 | 1,400 ₹39,200 Lowest | 1,500 ₹42,000 |
| 1.05 | 33 KV X -ARM | 172 | Nos | 2,000 ₹3,44,000 | 1,550 ₹2,66,600 Lowest | 1,950 ₹3,35,400 | 2,050 ₹3,52,600 | 1,600 ₹2,75,200 |
| 1.06 | STP 11 M long | 172 | No | 24,000 ₹41,28,000 | 19,900 ₹34,22,800 Lowest | 25,250 ₹43,43,000 | 20,150 ₹34,65,800 | 21,000 ₹36,12,000 |
| 1.07 | 33 KV pin insulator | 666 | No | 300 ₹1,99,800 | 325 ₹2,16,450 | 650 ₹4,32,900 | 280 ₹1,86,480 Lowest | 500 ₹3,33,000 |
| 1.08 | Top chanel 100X50 MM 10 kg / mtr | 35 | Nos. | 2,000 ₹70,000 | 2,350 ₹82,250 | 1,850 ₹64,750 Lowest | 3,150 ₹1,10,250 | 2,000 ₹70,000 |
| 1.09 | MS angle 65x65x6MM 5.8 kg / mtr | 600 | kg. | 87 ₹52,200 | 90 ₹54,000 | 120 ₹72,000 | 80 ₹48,000 Lowest | 100 ₹60,000 |
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
19 Apr 2025, 12:00 pmClosed
S.E., EDC-Lucknow Rural, Amousi Zone, Lucknow
S.E., EDC-Lucknow Rural, Amousi Zone, Lucknow
Construction of additional 33 KV Overhead and Underground Line work Bijnour to Mohanlalganj Under jurisdiction of EDD, Mohanlalganj, Amousi Zone, Lesa, Lucknow
2025_MVVNL_1027816_1
01/EDC-(Lucknow Rural)/25-26
Open Tender
Electrical Works
Item Rate
180 days
Lucknow
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹5,900
E.E., EDD, CESS-Ist, Ciss Gomti, Lesa, Lucknow
₹5 L
22 Apr 2025
12 Apr 2025
19 Apr 2025
12 Apr 2025
19 Apr 2025
12 Apr 2025
Amount
Supply Work
ACSR DOG CONDUCTOR
33KV 3X300 SQ MM XLPE CABLE
HDPE PIPE 160 MM Dia.
GI Pipe 200 MM Dia
33 KV X -ARM
STP 11 M long
33 KV pin insulator
Top chanel 100X50 MM 10 kg / mtr
MS angle 65x65x6MM 5.8 kg / mtr
33 KV pin with nut
M S Earthing Rod 20x2500 mm
LT XLPE Cable AL.1X400 Sq.mm.
33 KV ST/TH C/J KIT 3X300 SQ MM
33KV END TERMINATION O/DOOR 3X300 SQ MM
33 KV FEEDER CONTROL PANEL
33 KV VCB 800 AMP
33 KV CT 400/200/1 A
33 KV BUS ISOLATOR 800 AMP
33 KV LINE ISOLATOR 800 AMP
MS channel 100x50 mm
MS Channel 125x65mm 3.5m long 4 Nos Pieces [email protected] Kg. Mtr. With wastage
MS Angle 75x75x6, 2.6M 2 Nos Total [email protected] Kg./M with wastage
MS Angle 50x50x6 mm
33 KV LINE WORK/ ERECTION WORK .
Laying of double CKT 33 KV 3x300 sq mm XLPE cable in digging of trench 1100 mm, deep, 650 mm wide its boxing with brick,sand,stone slab after laying of cable filling and proper levelling& ramming.
Laying of double CKT 33 KV 3x300 sq mm XLPE cable in by HDD method as per Norms.
Laying of Single CKT 33 KV 3x300 sq mm XLPE By dirll method with MS/ GI Pipe 160 mm dia
Laying of double CKT 33 KV 3x300 sq mm XLPE By dirll method with HDPE Pipe 160 mm dia
Fabrication & erection of single pole for 33 KV line on 11 M long ST Pole with fixing of necessary clamp & other acessories like 1 no. Channel cross arm, Danger board, No Plate, barbed wire etc. contractor shall provide, necessary clamps, F‐Bracket etc. as per RESPO norms.
Fabrication, erection, grouting, plinthing & painting of double pole for 33 KV cable exposure on ST. Pole 11 Mtr long with fixing of necessary clamp channel ,angle 33 KV Pin & pin insulator making double ckt 3 phase 3 wire bus bar for separate cable with single core cable including electrode earthing , danger boared,barbed wire complete in all repect as per
Fabrication, erection, grouting, plinthing & painting of double pole for 33 KV END type Double Pole on ST. Pole 11 Mtr long with fixing of necessary clamp channel ,angle 33 KV Pin & pin insulator making double ckt 3 phase 3 wire bus bar for separate cable with single core cable including electrode earthing , danger boared,barbed wire complete in all repect as per
Fabrication, erection, grouting, plinthing & painting of TRI pole for 33 KV TRI Pole on ST. Pole 11 Mtr long with fixing of necessary clamp channel ,angle 33 KV Pin & pin insulator making double ckt 3 phase 3 wire bus bar for separate cable with single core cable including electrode earthing , danger boared,barbed wire complete in all repect as per
Fabrication, erection, grouting, plinthing & painting of Four pole for 33 KV Four Pole on ST. Pole 11 Mtr long with fixing of necessary clamp channel ,angle 33 KV Pin & pin insulator making double ckt 3 phase 3 wire bus bar for separate cable with single core cable including electrode earthing , danger boared,barbed wire complete in all repect as per
Stringing & Sagging of three phase 33 kv line on ACSR dog conductor as per RESPO Norms.
Guarding of 33 kv line as per RESPO Norms.
Hoisting of 3x300 sq mm sizes of 33 KV single cable on existing/erected double pole including GI pipe 3 mtr long 6'' dia including jumpering,dressing of cable with required all necessary clamps and nut, bolts.
Digging of Pit in kachcha/Pakka land in 1.2 mtr deep 3 mtr long and 2 mtr wide for 33 KV ST/TH 3x300 sq mm and boxing with brick sand and stone slab as per
High Pressure Testing of 33 KV cables/line as per norm
Supply And Fixing of cable marker
Plotting of cable layout rute on graph paper (i.e. depth underneath and distance from either side from prominent reference fixed point ) the reference point must not be more than 100 mtr.
Switch yard work
Earthing of Equipment
Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure for earthing (two nos Riser for each structure equipment individually GI strip shall be provided contractor )
Earthing of Indoor Equipment as per norms.(all material shall be provided by contractor)
Pipe Boring type earthing complete upto water level/ minimum 20 mtr deep from ground level complete Job with connection of quipment by 50x6 mm GI Strip
Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel)
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation Bolts for erection of 33KV VCB.
Isolator Structure‐Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by
Lightning Arrestor/ CT structure : ‐ Fabrication of lightning arrestor/CT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all
Painting of all structures equipment.
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .
33 KV VCB
33 KV lightning Arrestors
Bus/Line Isolator
Jumpering complete 33 KV bay with ACSR DOG Cond. and required clamp with nut & Bolts from 33KV cable stand to existing 33KV Busbar complete work.(01 no. 33 KV Bay)
Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per
Supply & Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system.
Copper Control Cable 2x2.5 Sq. mm.
Copper Control Cable 4x2.5 Sq. mm.
Dragging of 33 KV Control panel single feeder from unloading place upto control room and placement erection, earthing and grouting, commissioning & testing of the same as per RESPO Norms
Provide NOC from Electrical safety directorate before energizing erected 33 KV line
Tree branches cutting and chopping where required
GST Extra as per Rules
AMIT ENGINEERING CORPORATION (BID ID -5130989)
M/S Sushil Kumar (BID ID -5131798)
S.T.Electricals Pvt Ltd (BID ID -5130880)
M/S SMM INFRATECH PVT Ltd (BID ID -5131126)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .