| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-₹97.1 LAccepted-AOC | L- | Accepted-AOC Being L-1 | |
| 2 | L-2₹97.3 LRejected-Finance | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹98.7 LRejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹1.0 CrRejected-Finance | L-4 | Rejected-Finance other than L-1 | |
| 5 | L-5₹1.1 CrRejected-Finance | L-5 | Rejected-Finance other than L-1 |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
12 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
Provn of 1.5 MVA power supply and external services for regional network center at Udhampur
2020_MES_373186_2
CWE/U(U)-67/2020-21
Open Tender
Electrical and Maintenance Works
Lump-sum
240 days
Udhampur
AS PER TENDER
8 documents required · 8 mandatory
₹1,000
GE (Utility) Udhampur
₹2.1 L
Yes
13 Jan 2021
7 Nov 2020
14 Dec 2020
7 Nov 2020
12 Dec 2020
30 Nov 2020
60 days
Amount
BUILDING WORK (SCHEDULE 'A' PART-I) Lump sum price worked out by the Contractor for “Building Work” as listed in Schedule ‘A’ Part- I.
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-II) (SEC-I) Lump sum price worked out by the Contractor for “Internal Electrification” as listed in Schedule ‘A’ Part- II (Sec-I)
INTERNAL ELECTRIFICATION SCHEDULE `A' PART-III, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply & hanging ceiling fan AC single phase 230/240 volts of size 1200 mm sweep , having service value > 4.0 including making connection with and including suitable flexible copper wire, complete all as specified and as directed by Engineer-in-Charge.
Exhaust fan AC single phase 230/240 V of size 300mm sweep, metal body,speed 1400 RPM power input 50-55 W, Heavy duty with louver having aliminium / sheet metal flap with thickness not less than 1.00 mm and mounting assembly including fixing exhaust fan with grouting of nut & bolts , complete all as specified and as directed by Engr-in-Charge.
Slim linear LED lighting fixture/batten type 18/20 watt LED Batten T5, with full base of extruded aluminium section acting as a heat sink with closed back, complete making all connection using 1.5 sqmm copper conductor multi starnd PVC insulated 3 core flexible cable from ceiling rose to fitting complete all as per the direction of Engineer-in-Charge.
LED bulk head luminaire, 10 watt and connecting up with flexible copper conductor cable of suitable size complete all as specified and directed.
MCB SPN 6 to 40 Amps 50 C/S 10 KA 'C' sereis complete all as specified.
MCB SP 5 to 32 Amps ( ISI Marked) 50 C/S 10 KA 'C' sereis complete all as specified.
Sub Total
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-III) (SEC-I) Lump sum price worked out by the Contractor for “External Electrification” as listed in Schedule ‘A’ Part- III (Sec-I)
EXTERNAL ELECTRIFICATION SCHEDULE `A' PART-III, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply, laying & testing cable XLPE cable earthed system insulated heavy duty screened PVC bedded, galvanised strip or wire armoured electric power cable with stranded aluminium conductor 11000 volts grade (with earth system) as per IS, cross sectional area 150 sqmm 3 core complete all as specified and directed. NOTE :- (i) Cable shall be provided with different colours for different feeders as directed by Engineer-in-charge. (ii) The cable shall be brought in 500 m length of 02 drums of different colour and remaining cable in 02 drum of different colour as approved.
Description all as per srl item No 5.01 above but size of cable 95 Sqmm 3 core and except note (ii), complete all as specified .
Road cutting for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified by Engr-in-Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete, all as specified and directed by Engineer-in-Charge.
Description all as per srl item No 5.04 above but indoor type , complete all as specified .
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete, all as specified and directed by Engineer-in-Charge.
Description all as per srl item No 5.06 above but indoor type , complete all as specified .
Steel tubular swaged pole erected to truly vertical or planted as strut complete with 6 mm thick MS Base plate,welded to pole,finial taper cap, bolts, nuts, screws,11 Mtr long, type 410 SP - 55,including drilling of holes of required size for fixing of cross arms,painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the portion embedded in concrete, and marking pole no. with black paint at suitable height all as specified and directed by Engineer-in-Charge.Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’
Switch Air break gang operated tripple pole structure mechanically operated from ground level mounted on and including 12 No insulators and steel frame, out door type, suitable for vertical installation, single break, provided with locking arrangement consisting of MS channel, HT post type insulator copper alloy high pressure assembly with drop out fuse assembly with fuse carrier fuse element 5-20 amp mounted on insulator and operating rod of 25mm dia medium grade GI pipe complete conforming to IS-1018 of 1972 with continuous current rating upto 400 amps and voltage 11 KV including testing and commissioning all as specified.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (g) Testing of earthing.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including GI strips of size 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of GI strips from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (g) Testing of earthing.
Stay assembly comprising of 300 mm x 300mmx6mm thick galvanized mild steel stay plate galvanized stay rod of 20mm dia 1800mm long galvanized thimble stay, rod along with and fixed with 7/3.15mm stranded stay nuts and washers as shown on electrical plate No 1 or SSR Part-I including stay wire galvanised stranded 7/3.15mm as required at site complete all as specified and directed by the Engineer-in-Charge.
Route indicator made out of PCC 1:2:4 and MS bar 8mm of size 90cmx35cmx50mm complete dully marked as( HT 11KV U/G CABLE),dully fixed in ground incl. Excavation,PCC for fixing along the cable all as specified and directed by Engr-in-Charge.
Supply,Installation,Testing and Commisioning of HT 12KV, 3Phase 50Hz, totally metal clad withdraw able type Vacuum Circuit Breaker INCOMER panel with Copper bus bar of suitable rating, horizontal isolation type VCB of capacity 800 Amps rated current, as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof. The offered panels shall be tested for IAC level of 25kA/1 Sec, 350 MVA. No. of operation of Vacuum Interrupter Bottles for better performance: (i) Mechanical life -30,000 Nos , (ii) Rated Current – 10,000 Nos (iii) Rated Short Circuit Current – 100 nos.- All the main components like VI/ VCB/ Relays/ Meters shall be of same make. Panel and VCB parameters are as below: (i) Rated Voltage level/ PF withstand voltage/ Impulse level:12KV/ 28kV/ 75 kVp (ii) Continuous current rating: minimum 800 A (iii) Short circuit withstand current: minimum 25KA for 3sec. (iv) One no. minimum 800 Amps horizontal draw out type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following:-
Srl item No 5.14 Contd.... (a) Manually & Motor operated(230V,AC,50Hz) spring charged type, manually and electrically open (electrical – 110 VDC) operation type, incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position. (b) Cast resin Current transformer 11KV, 150-200/5-5A, Core1: class1, 15VA for 3 phase , Core2: 5P10, 15VA, (c) Cast resin potential transformer 11KV/V3/110V/V3/110V/3, 50VA, Cl 1.0, Cl 3P and HT Fuse at the primary end and 04 pole MCB at the secondary end of the PT (Confirming related IS specifications). A) Protection arrangements for the breaker shall comprise of the following: i) E/F, O/C, S/C, TCS with MODBUS protocol - Numerical Type ii) Relay should have mimic display iii) Complete with Master Trip/ Anti pumping relay.All the Relays shall belong to a common platform and shall be of single make (B) The following meters, indications and accessories are to be provided with the panel:
Supply,Installation,Testing and Commisioning of HT 12KV, 3Phase 50Hz, totally metal clad withdraw able type Vacuum Circuit Breaker OUTGOING panel with Copper bus bar of suitable rating, horizontal isolation type VCB of capacity 630 Amps rated current, as per IEC 62271-100-200.The switchgear panel shall be of sheet steel construction with ALUZINC with not less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof.The offered panels shall be tested for IAC level of 25kA/1 Sec, 350 MVA. No. of operation of Vacuum Interrupter Bottles for better performance: (i) Mechanical life -30,000 Nos , (ii) Rated Current – 10,000 Nos & (iii) Rated Short Circuit Current – 100 nos. - All the main components like VI/ VCB/ Relays/ Meters shall be of same make. Panel and VCB parameters are as below: (i) Rated Voltage level/ PF withstand voltage/ Impulse level:12KV/ 28kV/ 75 kVp (ii) Continuous current rating: minimum 630A (iii) Short circuit withstand current: minimum 25KA for 3sec. (iv) One no. minimum 630 Amps horizontal draw out type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following:-
Supply, installation, testing and commissioning of 11KV, 800 Amps, 25 KA for 1 Sec, 350 MVA HT vacuum circuit breaker panel for Bus coupler confirming to IEC 62271-200, IAC-AFLR-25KA for 1 Sec, LSC2B-PM class front accessed including comprising of following material: a) 800 Amp continuous rated electrolytic copper bus bars, droppers and bus bars should be insulated with full system voltage sleeves of Reychem or equivalent make. b) Cassette mounted vacuum circuit breaker as per IEC 62271-100. Vacuum circuit breaker should have three no. resin encapsulated vacuum bottles of the same manufacturer as of circuit breaker. c) Motorized spring charging mechanism with integral spring charging handle for manual spring charge. d) Interpanel epoxy barrier to restrict arc propagation from one panel to other. e) Accessories like local remote switch, breaker control switch(T-N-C), space heater with thermostat, DC & AC control circuit through f) MCB, indicating Lamps for RYB, Spring charge, DC supply healthy, breaker ON/OFF, breaker in SERVICE/TEST g) Master trip Relay and anti pumping relay. h) Electrical Interlock to prevent double sourcing.
Srl item No 5.20 Contd.... j) Panel should also have including additional facility like:1. Continuous rated closing and tripping coil of 24V DC. 2. Fully internal arc type tested (25 KA for 1 Sec) as per latest IEC 62271-200. 3. Vacuum bottles should be epoxy encapsulated. 4. Racking in/out, manual closing/tripping of CB with compartment door closed. 5. Breaker shall be provided with following contacts a. Auxiliary switch with 6NO+6NC mounted on the draw out portion of the switchgear. b. Position switches with 3 NO+1NC contacts for each position in SERVICE and TEST. Make : ABB/Siemens/ Schneider . NOTE FOR SL NO 5.14 TO 5.21 :- (i) 3 Sets of Literature,Maintenance Manual,Operatig tools required for the operations shall be supplied alongwith VCB's (ii) 8 Window Annunciated,hooter, suitable capacity of space heaters in VCB's to be provided and rates are included in above items.
Supply, Install, commissioning and testing of battery charger and DC Board as under: A) BATTERY CHARGER Automatic Float & Manual boost charger housed in one common panel/enclosures powder coated. The panel shall be rigid self supporting structure reassembled totally enclosed cubical constructed out of sheet metal of 2 mm thick. The panel shall have hinged door with adequate cross ventilation on both sides as well as on the top to avoid the unique rise of temperature. The panel shall be duly cleaned with chemical finish of synthetic enameled light grey paint internally as well externally. The charger equipment shall employee static semi conductor full wave silicon rectifier suitable for operation in conjuction with air cooled transformer single phase 230 volts 50 cycles supply. The charger shall consist of one automatic/manual float charger alongwith associated components for interlocking between the trickle charger and boost charger. The specification of the battery charger shall be as under :-
Srl item No 5.22 Contd.... 1. Type of Rectifier : Air cooled type 2. AC input : 230 volts 50 cycle 3. Type of charger : Servo control 4. Voltage variation : 230 V 5. Frequency : 50 C/Sc 6.Frequancy variation Plus minus 2 % 7. Boost Charger (i) Power output KW (ii) Voltage 36-43 volts 8. Float charger ; (i) Power output 0.43 KW (ii) Voltage 36-43 volts (iii) Current 10 Amps 9. DC output voltage regulation step less regulation from No load to full load 10. Maximum temperature : 35 degree to 40 degree C rise over and ambient temperature of 50 degree C. 10. Load limiting feature : Dropping characteristic beyond the starting cap of the charger. 11. Short time rating in amps and time : 10% over load for one hour. 12. Rated DC output voltage : (A) Float charger output voltage adjustable continuously 0-40 volts. DC when operated manually : (B) Boost charger voltage adjustable continously 0-50 volts DC. 13.Sealed Maintenance free Batteries of 2 volts and 100 AH each : 15 Nos
Srl item No 5.22 Contd.... B. DC BOARD 30 Volt DC distribution board in sheet steel cabinet made out of CRC sheet of 2mm thick, powder coated floor mounting hinged door on the back for easy access to the components installed inside. The board will be completed with wiring of copper conductor bus bar links crimping terminal block and labels together with support frame work including consisting of the following components with :- (a) Incoming Panels:- (i) Moulded case circuit breaker suitable for 30 volt DC 32 Amps 02 Nos single pole with over load and in short circuit released as incoming circuit - 01 No (ii) Moving coil volt meter digital type 96x96 mm range 0-50 V with fuse protection. (iii) Moving coil Ammeter digital 96x96 mm 0-30 Amp with LED indicating lamp. (iv) Indicating LED lamp on the incoming side. (b) Outgoing panel :- (i) Double pole MCB to work on DC Supply 30 volts of 10 A rating and provided with indicating lamps.
Supply installation, testing and commissioning HT 12V, 3Phase 50Hz, totally metal clad withdrawable type Vacuum Circuit Breaker OUTGOING panel with Copper bus of suitable rating, horizontal isolation type VCB of capacity 800 Amps rated current, as per IEC 62271-100 200. The switchgear panel shall be of sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing section and no less than 2mm thickness for non load bearing and shall be totally dust and vermin proof. The panel shall be tested for IAC level of 25kA/1 Second. No of operation of Vacuum Interrupter Bottles for better performance : (i) Mechanical life - 30000 (ii) Rated Current -10000 (iii) Rated Short Circuit Current - 100 Nos All the main components like VI / VCB / Relays/ Meters shall be of same make. VCB parameters are as below (i) Rated Voltage level/ PF withstand voltage/ Impulse level :12kV / 28 kV / 75kVp (ii) Continuous current rating minimum 800A
Srl item No 5.25 Contd.... (iii) Short circut withstand current :minimum 25KA for 3sec (iv) One No minimum 800 Amps horizontal draw out type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following: (a) Manually & Motor operated (230V AC 50HZ spring charged type, manually and electrically open (electrical -110 VDC ) operation type, incorporating mechanical as well as electrical ON / OFF indication "OFF push button, test service position limit switches with minimum 6NO + 6NC breaker auxiliary contacts in service position (b) Cast resin current transformer 11KV, 50-100-200 / 5-5A, Core1 :class1, 15VA for 3 phase, Core 2: 5P10, 15VA, (A) Protection arrangements for the breaker shall comprise of the following: i) E / F, OIC, SC, TCS with MODBUS protocol - Numerical Type ii) Relay should have mimic display iii) Complete with Master Trip/ Anti pumping relay iv) Auxiliary Relay Alarm / Trip, OTI/WTI, Bucholz etc. All the Relays shall belong to a common platform and shall be of single make
Supply only insulating rubber mat of size 1 meter x 2 meter x 19 mm, ISI marked suitable for 11 KV
Supply only Electric rubber hand gloves 15 KV, ISI marked of 355 mm length
Carbon dioxide (CO2) type fire extingushers ISI Marked of 4.5 Kg capacity and cylinders fully charged with mounting brackets supported on steel channel, first filling etc. complete all as specified.
Foam fire extingushers, ISI marked Portable type 9 Kg capacity hanged on wall with bracket complete all as directed.
Supply and fixing shock treatment chart of size 3'x 2' duly mounted on a wooden frame with 5mm thick sheet glass complete all as specified and directed by Engr -in charge.
M&L for Galvanized Iron fire bucket 9.5 ltrs capacity painted post office red colour over a coat of red-oxide primer and written with white paint 'FIRE' complete all as specified and directed by Engr -in charge.
Padestal type fire stand suitable for 4 Nos Fire buckets of capacity 10 litre of size 1M height and breath made out of 50mm dia bore light grade GI pipe incl mounted on 0.60x0.45m long legs made out of 50 mm GI pipe light grade and top shed of size 1.5M long and 0.6M each half made out of 50x50x6mm angle iron incl red colour superior quality paint and write on top sheet " FIRE" and 3.15mm thick sheet and provision of 'J' hook for hanging of fire bucket incl PCC work complete as specified and directed and directed by Engr -in charge. Note: Drg No CEUZ/TD/1234/06 sheet-1/1 shall be followed.
Supply and placing First - aid box made of metal of size 200mm x 300mm x 150 mm deep complete with stapple hinges and painting with two coats of synthetic enameled paint over a coat of primer complete with one set of First Aid medicines all as directed by Engr-in-charge.
XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 16 sq mm 2 core, laid in trenches/ducts/through pipe complete all as specified and directed.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
40 mm bore tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed
Sub Total
EARTH WORK AND SITE CLEARANCE (SCHEDULE 'A' PART-IV) Lump sum price worked out by the Contractor for “Earth work and site clearance” as listed in Schedule ‘A’ Part- IV .
SHIV CHARAN GUPTA AND SONS
MOHAN LAL AND SONS
M/S N.K BUILDERS
proach associates
V K Sales and Construction Co
vijay builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .