Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.1 LAccepted-AOC 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹31.5 L+₹94,690.45 (3.10%)Rejected-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹36.9 L+₹6.3 L (20.6%)Rejected-Finance 70 SUBHASH ROAD HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | Rejected-Technical 361 D SHAKTI NAGAR NEAR KHAN DAIRY INDIRA NAGAR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | - | Rejected-Technical Cat not enlisted in a(i) cat | |
| 5 | Rejected-Technical | - | Rejected-Technical Cat not enlisted in b(i) cat |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
19 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST LUCKNOW
GE EAST LUCKNOW
REPAIR/MAINT OF INTERNAL ELECTRICAL FITTING/FIXTURE, MISC WIRKS AND COMPREHENSIVE B/R MAINT OF OTM/MD ACCN AND MES INSTALLATION AT MIL STN BARABANKI UNDER GE (EAST) LUCKNOW
2022_MES_571366_1
GE/E/LKO/T-44 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BARABANKI
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE EAST LUCKNOW
₹98,000
Yes
24 Feb 2023
27 Dec 2022
21 Jan 2023
27 Dec 2022
19 Jan 2023
7 Jan 2023
Amount
Dismantling of asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings including ridges, hips, valleys and flashings complete all as specified and directed.
S&F for 6mm thick asbestos cement corrugated or semi corrugated sheet as in roofing fixed with 'L' or 'J' type or cranked hook bolts complete all as specified and directed.
S&F for 6mm thick asbestos cement two piece serrated ridges for corrugated or semi-corrugated sheet fixed with 'L' or 'J' type or cranked hook bolts including dismantaling unserviceable complete all as specified and directed.
S&F for pre-laminated galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for prelaminated galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Excavating in post holes (or similar holes) each not exc 0.5 cum getting out and removing surplus soil to a distance not exc 50 m and making good surface in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches exc 1.5m but not exc 3.0m depth for foundation etc or for shafts, wells, cesspits, manholes, etc not exc 10 sqm on plan and not exc 1.5 m depth & getting out in soft/loose soil complete all as specified and directed.
Returning filling in trenches including spreading leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing of excavated materials to a distance 1.5 km and depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4, type B-1 smooth finished, and reforming benching complete all as specified and directed.
Dismantlibng wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling fencing wire mesh of any type complete all as specified and directed.
S&F for mild steel work in posts and struts in fencing including cutting tops to shape as directed including drilling holes, notching for wire etc , flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed .
All as per item No 14 above but except angle
S&F for rolled section as in main & cross beams, hip & jack rafters , purlins where connecting to common rafters & running rails & guides for sliding doors fixed with angles , cleats or other connecting plates confirming to Fe-410W (Gde-E-250) complete all as specified and directed.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) including cleaning washing down etc complete all as specified and directed.
M&L for brushing neat cement slurry with 3 Kg of cement per sqm complete all as specified and directed.
M&L for PCC 1:2:4, type B-0 (using 12.50 mm graded stone aggregate) as in padding to maintain the slope complete all as specified and directed.
M&L for cleaning of all loose dirt and dust from roof surfaces and applying roof treatment as under :- (a) M&L for 15mm thick plastering in CM 1:4 using 100% course sand on roof including mixing of WPC @ 3% by weight of cement. (b) Applying a coat of bitumen primer @ 0.50 ltr/sqm on prepared and allow to dry. (c) Applying a coat of hot blown type bitumen grade 85/25 @ 1.20 Kg/Sqm over primer. (d) Supplying and laying min 3mm thick APP modified polymeric membrane thick polymeric water proofing membrane weight not less than 3 Kg/Sqm. (e) Applying two coats of bituminous aluminium paint 200 gram/Sqm (minimum). Note: WPC shall be measured and paid seperately under this BOQ.
Supply only integral water proofing compound ISI marked complete all as specified and directed.
Dismantling of timber scantling 40 sqcm and over in section in any position as in unframed work complete all as specified and directed.
S&F of second class hardwood scantling clean swan as in purlins rafters including wooden cleats etc complete all as specified and directed.
Dismantling of wall & ceiling boards (fiber, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M&L of anodized aluminium snap grid size 605x605mm of frame work for false ceiling as per clause 10.38 of SSR Part I - Specifications (2009) complete all as specified and directed.
S&F 12 mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
S&F for mild steel work as in small articles of required size as in hold fasts, angle cleats, MS grating, clamps, hooks, straps, support or stays for rain water pipes including bolts required and similar small articles conforming Gde Fe 410-0 complete all as specified and directed.
Taking down chowkhat or farme with shutter (without taking off shutter from the frame) area not exc 1.50 sqm each and removing from site complete all as specified and directed.
Taking down chowkhat or farme with shutter (without taking off shutter from the frame) area exc 1.50 sqm but not exc. 4 sqm each and removing from site complete all as specified and directed.
Taking down shutter of any description area not exc 1 sqm each and removing from site complete all as specified and directed.
Taking down shutter of any description area exc 1 sqm but not exc 2 sqm each and removing from site complete all as specified and directed.
Taking down shutters of any description area not exc 1 sqm each resecuring or easing & adjusting of shutter and refixing in same opening complete all as specified and directed.
Taking down shutters of any description area exc 1 sqm but not exc 2 sqm each rescuring or easing & adjusting of shutter and refixing in same opening complete all as specified and directed.
S&F 2nd class hard wood plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F 35mm thick second class hard wood galzed & skeleton shutters open rebated, prepared to receive glass, guaze etc. divided into square with plain chamfered or rounded, mitred and rebated sash bar any numbers and sizes of members of shutters as specified in SSR Part-I (2009) section 8 of clause 8.23 (a) complete all as specified and directed.
S&F for 30mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality & glazing with oil putty or wooden beads in square area not exc 0.5 sqm in each pane glazed with putty or wooden beads complete all as specified and directed.
S&F for stainless steel wire cloth of 0.36mm nominal dia of wire & average width of aperture 1.40mm complete all as specified and directed.
M&L for preparation of previously untreated surfaces of wood or wooden based materials of any description over 10cm width or girth and applying two coats of synthetc enamel paint over a coat of pink primer complete all as specified and directed.
S&F of stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed, including taking down old wiremesh complete all as specified and directed.
M&L for preparation of old painted surface of wood and wood based materials of any description over 10cm in width or girth and applying two coat of synthetic enamel paint complete all as specified and directed.
S&F solid PVC door frame of size 50 x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube etc complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting frame made out of MS tube for top and bottom rail MS frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for style and plain colour PVC sheet for top rail lock and bottom rail on either side and as gap insert for top rail and bottom rail plain colour PVC sheet tape fixed in MS frame welding sealed to the style and rail with suitable PVC sheet bearing and jointing together with solvent cement etc complete all as specified and directed.
S&F in repair 19/20 mm thick prelaminated particle board, exterior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work complete all as specified and directed.
S&F continuous (piano) hinges, mild steel, bright finish or electro galvanized width of flaps 30mm (when open) fixed with CP steel screws, complete all as specified and directed.
S&F for 40mm dia cupboard knobs fixed with nut, screw & washer of mild steel, bright finished complete all as specified and directed.
S&F of mild steel work as in guard brass, grills, gratings and similar work confirming to Fe 290 Gde-E-165 etc complete all as specified and directed.
M&L framed work as in doors or gates of angle or other section with gusset plates , rails braces etc complete drilling for fixing of steel sheeting or other covering materials or welding complete all as specified and directed .
S&F steel window with side hung shutter ( glazed) including box type hinges, steel handle, peg stay, lugs complete with glazing bars and painted with one coat of red oxide primer complete all as specified and directed.
S&F for steel window with side hung shutter (mosquito proof) with box type hinge , peg stay, lugs, handles, without glazing bars complete including one coat of red oxide primer complete all as specifed and directed.
S&F 30 mm thick IInd class hard wood locally fabricated glazed and skeleton window or ventilator shutter open rebated and prepared to receive glass etc divited into square with plain chamfered or rounded, mitred beads for securing glass/gauge in SSR Part-I, 2009 section 8 clause 8.20 (b) complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specifed and directed.
M&L for preparation of old painted surface of steel or iron work of any description over 10cm in width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
S&F for stainless steel butt hinges medium weight 100mm size complete all as specified and directed.
S&F for stainless steel butt hinges medium weight 75mm size complete all as specified and directed.
S&F 150 mm size alumium alloy handle, fabricated type extruded section complete all as specified and directed.
S&F 100mm size alumium alloy handle, fabricated type extruded section complete all as specified and directed.
S&F 200mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed.
S&F 150mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed.
S&F 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and directed.
S&F in repair mild steel 150mm, ordinary rat tail rod pattern springs including roller & roller plate complete all as specified and directed.
S&F in repair harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc curtain rods 22-25 mm dia including knobs and brackets complete all as specified and directed.
Taking down of cement plaster in any description on brick or stone wall etc, including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or on concrete surfaces in CM 1:4 finished fair and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on other than fair faces of brick work or on concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:4 on ceiling of concrete surfaces and finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new plastered surface of wall including cornices etc and applying two coats of cement base paint (any colour as approved) complete all as specified and directed.
Complete removal of existing treatment from walls, preparing the surface of wall including cornices plasters etc and applying two coats of cement base paint (any colour as approved) complete all as specified and directed.
M&L for preparation of new plaster surface of wall and applying two coats of oil bound distemper on old surface of wall complete all as specified and directed.
Complete removal of existing treatment from walls, preparing the surface of wall including cornices plasters etc and applying two coats of oil bound distemper ( any shade as approved )complete all as specified and directed.
M&L for complete removal of existing treatment of wall and wash down etc and applying three coat of white wash including preparation of surfaces complete all as specified and directed.
M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of white wash on ceiling complete all as specified & directed.
M&L for applying 3mm thick wall care putty on wall complete all as specified and directed.
M&L for preparation of old painted surface of wood and wood based materials of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted surface of steel or iron work of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of cement base paint complete all as specified & directed.
M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of oil emulison distemper (OBD), complete all as specified & directed.
S&F in repair vitreous china squatting pan "Orissa" pattern size 580mmx440mm white with integral foot rests including connection to trap and to flushing pipe, anti syphonage pipe, etc complete making good to floor complete all as specified and directed.
S&F in repair for plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair PVC valveless, syphonic action type flushing cistern 10 lit capacity, low level white with inlet, ball valve, float and handle including brackets and flush pipe fixed etc complete all as specified and directed.
S&F in repair vitreous china urinal, bowl type (back or corner wall type) size of 465x355x265mm white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, complete all as specified and directed.
S&F in repair viterous china wash hand basin white flat back type of size 550x400mm including cutting for and pinning in ends of brackets and fixing in walls including 32mm dia chromium plated waste coupling , PVC waste pipe and MS brackets complete all as specified and directed.
S&F GI tubing 15mm bore medium grade with all fittings fixed to wall, ceiling or laid in floor including taking up or down of existing steel tubing and connections complete all as specified and directed.
S&F GI tubing 20mm bore medium grade with all fittings fixed to wall, ceiling or laid in floor including taking up or down of existing steel tubing and connections complete all as specified and directed.
S&F in repair bib tap 15mm dia, chromium plated cast copper alloy with fancy type handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair stop/angle valves 15mm bore chromium plated, cast copper alloy with fancy type handles screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly-nuts, screwed for iron pipes & fixed complete all as specified and directed.
S&F in repair brass chromium plated wall mixer with hot and cold arrangement, long shank suitable for 15mm bore of pipe of approved quality without telephonic shower complete all as specified and directed.
S&F in repair chromium plated single hole basin mixer with hot and cold arrangement, long shank suitable for 15mm bore of pipe of approved quality complete all as specified and directed.
S&F 32mm bore brass chromium plated bottle trap for wash basin with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified and directed.
S&F in repair aluminium tubular towel rail of superior quality 'D' type 20mm dia 60cm long between flanges complete all as specified and directed.
S&F in repair CP Shower rose with arms 15mm dia complete all as specified and directed.
S&F in repair 40mm bore waste coupling of PTMT (half or full thread) for sink complete all as specified and directed.
S&F in repair of 20 mm bore ball brass valve high pressure with polyethylene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair of 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F PVC connection 15mm dia, with PTMT nuts of length 600mm complete all as specified and directed.
S&F PVC waste pipe of standard quality suitable for 32 mm bore waste coupling for WHB/ urinal complete all as specified and directed.
S&F for glass shelves for looking mirror of size 450x125mm with chromium plated guard, fixed with brass screws and wooden/plastic cleats complete all as specified and directed.
S&F for corner glass shelf 300mm with chromium plated guard, fixed with brass screws and wooden/plastic cleats complete all as specified and directed.
S&F for PVC corner shelf 300 mm with chromium plated guard, fixed with brass screws and wooden/plastic cleats complete all as specified and directed.
S&F CP health faucet with 1000 mm long flexible mild steel tube with wall hook complete all as specified and directed.
S&F in repair CP brass toilet paper holder fixed to wall with chromium plated brass screws of approved quality complete all as specified and directed.
S&F PVC cabinet with mirror and door of size 560X410mm complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L glazed ceramic joint free coloured tiles in vertical surfaces 450x300x7mm thick, set and joiunted in neat cement slurry and pointed in coloured cement to match over and including 10mm thick screed bed in cement mortar 1:3 complete all as specified and directed.
M&L coloured non skid ceramic jointless tiles 7 to 8mm thick (square/rectangular) are of each tile exc 0.11 sqm but not exc 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer with CM 1:4 complete all as specified and directed.
All as per item No 108, but as on dado/ skirting over and including 10 mm thick rendering in CM 1:4.
M&L for non skid ceramic (coloured) jointless tiles of 7 to 8mm (square or rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15mm thick screed CM 1:4 complete all as specified and directed.
M&L for vitrified ceramic tiles 10 mm thick (square/rectangular), polished, coloured (dark shade as approved), area of each tile not exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15mm thick screed CM 1:4 complete all as specified and directed.
Dismantling existing water tanks of capacity exc 500 Ltr but not exc 1000 Ltr including removing from site complete all as specified and directed.
S&F for 1000 Ltr capacity rotational moulded polyethylene, three layer, PVC water storage tanks (cylindrical or vertical with closed top) hoisted and fixed in position complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks and mouths of circulating pipes, etc. of capacity of tanks exc. 250 ltrs and not exc. 500 ltrs cleaning with wire brush complete and metioning the date of cleaning with paint complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. of capacity of tanks exc. 500 ltrs and not exc. 1000 ltrs cleaning with wire brush complete and metioning the date of cleaning with paint complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving not exc 15cm thick above or below ground level complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4, type B-1 (using 20mm graded stone aggragate) as in floor finished cement concrete surface even and smooth with using extra cement complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection finished even and smooth using extra cement complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, fillings and mass concrete and embedding of fencing post etc complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintel up to 1.5m clear span, cills, steps, bands, coping including weathering, slightly rounded or chamfered, angle and throating as directed and other similar work including necessary form work complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in man hole, surface channel and drain complete including finished surface complete all as specified and directed.
M&L for precast RCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in cover slab, shelves and similar articles set in CM 1:4 complete all as specified and directed. (Note:- Reinforcement shall be measured & paid separately only)
M&L for TMT bar 10mm dia and over cut to length, bent to shape required including cranking and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bar 6 to 8 mm dia and over cut to length, bent to shape required including cranking and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floor, aprons etc complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver blocks any tiles any size and shape factory casted with grey cement and pigment and conforming to IS 15658-2006 of M-35 Grade and joints filled including dismantling of old unserviceable complete all as specified and directed.
M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick over and including 20mm thick screed bed in CM 1:6 laid and jointed with grey cement clurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
All as per Item No 129 above but as in skirting, dado over and including 10mm thick rendering in CM (1:4).
M&L for 18-20 mm thick granite work (table rubbed & polished) in steps, jambs, pillars, window-cills cooking platforms & like over and including 15 mm thick cement mortar (1:4) including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite complete all as specified and directed.
S&F in repair viterous china wash down water closed pan (Pedestal pattern) with 'P' or 'S' trap white fixed in repair including connection to trap and cistern, flush pipe including plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device and making good disturbed surface of floor complete all as specified and directed.
S&F PVC connection 15mm dia, with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repair CP Jet spray with flexible tube complete all as specified and directed.
S&F in repair aluminium anodised peg set of 6 legs fancy type, complete all as specified and directed.
Taking down rain water pipes ( any size or pattern) including all fittings, shoes, bends, swan neck etc complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall including MS holding clamps complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall including MS holding clamps complete all as specified and directed.
S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F of 110mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed.
S&F of 75mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed.
M&L for PVC (SWR) Gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal of 110mm bore single socketed in any length with rubber ring joints, laid in trenchs or in floor complete all as specified and directed.
S&F PVC (SWR) Junction double, (Double T) equal or unequal of 110mm bore single socketed in any length with rubber ring joints, laid in trenchs or in floor complete all as specified and directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal of 75mm bore single socketed in any length with rubber ring joints, laid in trenchs or in floor complete all as specified and directed.
S&F PVC (SWR) Junction double, (Double T) equal or unequal of 75mm bore single socketed in any length with rubber ring joints, laid in trenchs or in floor complete all as specified and directed.
S&F for 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F for 110mm bore PVC (SWR) ‘P’ trap complete all as specified and directed.
S&F 30mm thick 2nd class hard wood plain framed panelled shutter any number of panels with panels of timber flat on both side not less than 12mm thick complete all as specified and directed.
S&F floor door stopper of aluminum alloy body & tongue, anodized, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F anodised aluminium door seal of standard aluminium section fixed with screws complete all as specified and directed.
S&F in repair kitchen Plate rack size 900 x 600 mm with average depth including necessary racking system and fixed in positon with rawal plug including taking down old fitment complete all as specified and directed.
Taking out existing aluminium shutter any type and refixing of aluminium shutter fixed with glazed/ particle board in panels including all necessary repair and replacing the aluminium snap beading, rubber packing, glazing clip etc complete all as specified and directed.
S&F of 5.50 mm thick sheet glass, ordinary quality and glazing with oil putty or aluminium beading in square exc 0.5 sqm in each pane including hacking out old broken glass (any thickness, size, quality or description) from iron frames glazed with putty or wooden beads complete all as specified and directed.
S&F aluminium (Extruded section body) door closer hydraulically regulated, designation No.3, universal type,suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work with fly ash bricks old size, straight or curved on plan exc. 6.0 meter mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L brick work except bricks (using old bricks recieved from demolition), straight or curved on plan exc. 6.0 meter mean radius, built in cement mortar 1:6 complete all as specified and directed.
S&F exterior tiles superior quality 25 mm thick of approved size/design/shade set & jointed in neat cement slurry & pointed in white or coloured cement to match as in floor over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for ATT, treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for providing and injecting chemical emulsion for post constructional antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sqm of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc complete all as specified and directed.
M&L for ATT, at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
S&F in repair galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts including securing or type at crossings with and provision of galvanised mild steel wire staples or steel pins, etc complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply only chain link MS galvanised chain link fencing 75x75 mm mesh size complete all as specified and directed.
M&L chequered cement concrete tiles 20 cm x 20 cm x 25 cm thick set and jointed and pointed in neat cement slurry with grey cement and pigment in floors including 20 mm screed bed in CM 1:6 complete all as specified and directed.
M&L for salt glazed stoneware drain pipes 150mm grade ‘A’internal dia laid in trenches and jointed complete all as specified and directed
M&L for factory made RCC man hole cover /drain cover with cover frame comprising of 75mm thick cover, including provision of hot dip galvanized lifting hook for lifting overall cover with suitable size angle iron frame, RCC cover of M-30 grade concrete by vibro compression process, medium duty confirming to IS-12592 including fixing on manhole, demolition of existing coverwith cover frame and removal of debris from site complete all as specified and directed. Note : The factory made RCC cover shall be ISI marked and as approved.
Demolition and breaking up drain pipes 150mm dia salt glazed stone ware AC or rein forced concrete pipe incl PCC haunching etc set in cement mortar including removal from site complete all as specified and directed
M&L for cement concrete 1:4:8, type D-2 for 150mm bore of pipe as concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed .
Dewatering of soak well , septic tanks by using mechanical pump diesel driven with fuel operator and crew of water etc at site complete all as specified and directed.
Cleaning of soak well, septic tanks by way of desludging foreign material manually/mechanically and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off outside of MOD premises (at the location notified by the local Municipal Corporation/ Cantt board as per rules of public health), including digging required nos of pits for depositing sludge and future capping the pit with the 25 cm thick layer of soil and sprinkling bleaching powder (including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
Cleaning of blockage of 150mm bore sewer lines (i.e. branch sewer line, main sewer line) by way of cleaning desludging foreign material as well as roding of sewer line between successive manholes manually/mechanically or pumping out sewage from blocked line including desludging where required and ordered by Engineer-in-Charge and keeping sewer line functional from Ist manhole upto final drop as septic tank, soakage well complete all as specified and directed . Note for item No-172 to 174 1.The cleaning shall be carried out with mechanized operation by means of diesel / electric operated vehicle mounted hydraulic operated high pressure suction -cum -jetting machines fitted with pump of required capacity and the sludge sucked out with Super Succer Machine of required capacity and sent to storage tanks for further disposal to the authorised disposal site land at any distance and without any additional cost. 2. The sludge deposited in sewage line shall be fully cleaned and disposed off the same outside the MOD land at any distance and without any additional cost , on the same day when it was taken out.The job shall be carried out with safety precaution equipment and with strict supervision . 3. During the mechaized operation , the service provider /Contractor shall be equiped with Gas monitor , nylon rope ladder , torch light and compressor blower etc along with the sewage cleaning truck mounted suction / jetting machine . 4. The unit rate quoted by the contractor shall interalia deemed into the cost of providing skilled driver and operator and supervising engineer including provision of water for jetting & removal of sludge /silt /liquid /mud & sand (in foul position )etc. 5. The contractor shall engage the above mentioned T & P and intimate to Enginner - In -Charge in writing with Machine No./ Vehicle No. etc for their record and prior approval . 6. A Register shall be maintained showing the Machine No /Vehicle No. and their deployment at site mentioning time and date duly sighned by concern JE , Engr -in- charge and contractor and the same register shall be produced while claiming the payment by the tenderer .
Cleaning of all manholes upto 1.5 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soil and sprinkling powder (including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
Cleaning of all manholes upto 3.00 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soil and sprinkling powder ( including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
Cleaning of all blockages of Nahni traps/floor traps/bottle traps, blockages of WC's, upto 1st manhole/Gully Trap in shafts, vertical CI soil/waste pipe stacks, CI Tee/door bends etc & cleaning of drain pipes of any dia by rodding and removal of sludge/silt/liquid mud sand (in foul conditions) etc, out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board). To Maintain of internal & external sewage system in functional state at all the time by engaging/deploying minimum One Safaiwala alongwith one Helper from 0900 hours to 1700 hours at Complaint cell of AGE B/R-II area mentioned in the contract on daily basis, with manual/ pressure cleaning pump and flexible rods and other necessary equipments (as per rules of public health), complete all as specified and directed. Note :- For item No- 176 to 177 1. The Nos of person indicated in above items as assumed by the department, shall remain present at the complaint cell of SDO Barabanki area mentioned in CA. Contractor may have to deploy more manpower in the particular area and deploy adequate sewage cleaning machinary/ equipments to clean the line and open blockages. Rates quoted shall be deemed to have considered in the items all such contingencies. 2. In case of non availability/ absence of any of minimum required man power, the recovery for the same shall be effected @ Rs 500.00 per day for the absence period proportionaly. 3. If necessiated by the Engr-in-charge/GE for work on Sunday/ holidays, the contractor shall provide tradesmen with helpers. 4. Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produced for verification at the time of payment of each RAR/Bill.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified & directed.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including concealed PVC Conduit medium grade, ISI marked not less than 19.5 mm / 20 mm dia (Make: Caps/Polypack/Seiko) along with conduit fixing accessories and with pressed steel terminal box for fixing switches etc. complete with continuous PVC insulated unsheathed green colour copper earth wire of size 1.50 Sqmm(FRLS) and connected to common earth dolly, complete, all as specified and directed. Note:- After rewiring cutting chasing portion should be matched with existing finishes of walls.
All as per item No 179 above but 5 Amp socket outlet independent.
All as per item No 179 above but on the same board.
All as per item No 179 above but for one bell/Buzzer point controlled by one push button on the same board with other switches or independent with 1.50 sqmm size cable.
All as per item No 179 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly.
S&F in repair switch piano 5 Amp one way, single pole, 240 volts complete all as specified and directed.
S&F in repair socket outlet 5 Amp, 5 Pin, 240 volt, complete all as specified and directed.
S&F in repair bell push, single pole 1 way 240 volt, complete all as specified and directed.
S&F in repair call bell , multi tune, single phase, 230 volts, complete all as specified and directed.
S&F in repair switch socket outlet, two in one 5 & 15 Amp, 6 pin, multipurpose combination, complete all as specified and directed.
S&F in repair ceiling rose, 3 phase/PVC/polycarbonate, isolated body three terminals complete all as specified and directed.
S&F in repair ceiling fan regulator electronic 5 step for 1200/1400 mm sweep complete all as specified and directed.
S&F in repair of modular ceiling fan regulator electronic 5 step for 1200/1400 mm sweep for 2 Module complete all as specified and directed.
S&F LED post top lantern fitting for 360 degree indirect light 35W IP 65 protection complete all as specified and directed.
S&F LED Flood Light 100W equiped with IP 66 protection or above complete all as specified and directed.
S&F in replacement of surface mounted LED tube light fitting four feet long, 18-22 Watt, 2000 lumen, Polycarbonate diffuser having 3000K warm day light with IP 20 protection comprises of aluminium extruded channel, frosted diffuser, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all as specified and directed. Make : Havells Cat Part No ENDURALINEARNEOBS20WLED830SPCWH or equivalent in Crompton / Philips as approved by GE.
S&F in replacement of LED mirror light fitting, 14 Watt, 2 feet long with IP 20 protection comprises of aluminium extruded channel, frosted diffuser, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all as specified and directed. Make : Crompton Cat Part NO LCL-14-CDL or equivalent in Havells / Philips as approved by GE.
S&F in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed.
S&F in repair LED lighting fixture with extruded alluminium heat sink, environmental friendly, energy efficient ready to use suitable for 4’ LED tube complete all as specified and directed.
S&F LED T8 IP 20 linear tubular lamp 20 watt(4') single end with PC diffuser complete with inbuilt driver complete all as specified and directed.
S&F LED T8 IP 20 linear tubular lamp 20 watt(4') double end with and PC diffuser complete with inbuilt driver complete all as specified and directed.
S&F PVC casing caping ISI marked of size 20/25 mm complete all as specified and directed.
Supply only LED 10 W B22 WW/CDL Ball lamp, 3 star rating complete all as specified and directed.
All as per item No 201 above but 15 W LED Ball lamp.
All as per item No 201 above but 20 W LED Ball lamp.
Taking down Ceiling fan/Exhaust fan any size any make, sealing cable ends including dismantling blades in case of ceiling fan and removing fan and blades to E/M store and refixing after necessary repairs and connecting up complete all as specified and directed.
Repair and overhauling of Ceiling fan/ Exhaust fan/ Cabin fan/ Wall mounting fan/ Table fan/ Pedastal fan of any size by oiling/ greasing and reassembling the fan with new split pin, check nut, locking nut, washer, holder clip & connector. Note:- Testing and refixing of same fan shall be made to the entire satisfaction of Engineer-in-charge. Note: Repair work will be carried out at MES workshop/at site/ Users Residence as directed. Material required (Ball bearing and Condenser) for replacement of items will be measured and paid separately.
M&L in replacement of ball bearing of size 6201/6202/6203 or as required complete all as specified and directed.
S&F capacitor 2.5m Fd, ISI marked for ceiling fan of any size and exhaust fan of size 300/450mm cabin fan sweep complete all as specified and directed.
Petty Repair of ceiling/ exhaust/ Pedestal/ cabin fan electric line from Switch Board to ceiling rose, replacing minor parts, like Split pin, bolts, nuts, oiling of bearing/bush from out side etc complete all as specified and directed.
Rewinding of Ceiling/ Exhaust/ Cabin fans and pedestal fans comprising of followings: a) Rewinding of stator with supper enameled copper wire (gauge of wire shall be same as provided by the manufacturer) including varnishing the new winding wire with quick dry varnish properly. b) Replacement of defective worn out bush where required, (ball bearing, capacitor will be measured and paid separately). c) Oiling/greasing and reassembling the fans with new split pin, check nut, locking bolt, washer, holder clip and connector including providing new ISI mark three core flexible copper wire of size 1.5sqmm of 1 Mtr length. d) Testing of repaired fan shall be carried out in the yard of SDO (MES) BBK to the entire satisfaction of the complete all as specified and directed. For ceiling fan of 1200 /1400 mm Sweep
All as per item No 209, For exhaust fan 450 mm (18") Sweep
All as per item No 209, For exhaust fan 230 mm sweep or Cabin Fan 300 mm sweep
All as per item No 209, For cabin/wall fan 450 mm Sweep
S&F blade set (set of three) for any type/make of ceiling fan 1200 mm sweep complete all as specified and directed. (Note:- OEM spares only)
S&F blade set with frame & four legs of fan with coupling for 300 mm (12") sweep exhaust fan complete all as specified and directed. (Note:- OEM spares only)
S&F blade set with frame & four legs of fan with coupling for 450 mm (18") sweep exhaust fan complete all as specified and directed. (Note:- OEM spares only)
S&F louvers for 300 mm sweep exhaust fan complete all as specified and directed.
S&F louvers for 450 mm sweep exhaust fan complete all as specified and directed.
S&F flexble wire ISI mark copper of size 1.5 sqmm complete all as specified and directed.
M&L in replacement of unserviceable hanging clamp for ceiling fan of any type complete with rubber reel, split pin, bolts, nut and washer all as specified and directed.
S&F of GI Tubing 40 mm bore, light grade with all fittings fixed to wall, floor, ceiling or laid in floors complete all as specified and directed.
S&F anchor fasteners having 12mm dia hook bolt for hanging ceiling fans or similar items complete all as specifed and directed.
M&L spray painting of fan with one coat of super enamel white paint after cleaning of body and blades, down rods, with detergent powder and writing MES Nos with black paint at given site under SDO (MES) Barabanki area complete all as specified and directed. (Note:- The work shall be carried out at site)
M&L for replacement of worn out/defective roter shaft for ceiling fan, exhaust, fan, cabin fan of any make and size complete all as specified and directed.
Taking down the geyser of any make and size horizontal or vertical from site for repairs/overhauling/replacement of unserviceable parts (Repairs/replacement of parts Shall be measured and paid separately) including replacement of old nuts and bolts with washers heavy duty including disconnection of electric supply, water supply lines and refixing the the geyser in the serviceable condition after assembling, testing and reconnecting the electric/ water supply line complete all as specified and directed. (Note:- Replacement of unserviceable parts of old Geyser shall be measured and paid separately under respective item here in after except bolt, nuts and washers)
S&F in replacement of heating element 1.5 KW of Geyser (ISI marked) for any make and type complete all as specified and directed. (Note:- OEM spares only)
S&F in replacement of heating element 2 KW of Geyser (ISI marked) for any make and type complete all as specified and directed. (Note:- OEM spares only)
S&F in replacement Thermostat (ISI Marked) suitable for any type, make and capacity of geyser complete all as specified and directed. (Note:- OEM spares only)
S&F in replacement of unserviceable indicating lamps red and green colour for Geysers any make complete all as specified and directed. (Note:- OEM spares only)
Supply and replacement of unserviceable door assembly ISI marked comprising of inlet and outlet thermostate, housing with gasket complete with bolts, nuts, washers, screws of packing suitable for any type and make of geyser complete all as specified and directed
M&L for repairing of leakage of inner copper/steel tank of any type /capacity and make of geyser by brazing complete including necessary denting, machinery charges etc complete all as specified and directed.
S&F in repair stainless steel inner tank 25 Ltrs capacity, ISI mark of as per existing gauge for geysers complete all as specified and directed
S&F in replacement of brass safety valve heavy duty ISI marked for any type and make of geyser suitable for 15 mm bore of pipe complete all as specified and directed.
S&F for 450mm thick PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity geyser complete all as specified and directed.
S&F for 600mm thick PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity geyser complete all as specified and directed.
S&F in replacement of recesses mounted 2'x2' LED ceiling light fitting 37 Watt, 3650 lumen, 6500K, with IP 20 protection comprises of CRCA housing, high efficiency diffuser cover, electronic driver, etc and all accessories pre-wired including connecting up complete ass as directed. Make : Philips, Cat No : RC383B LED 36S-6500 PSU OD WH PIR or equivalent in Crompton/Havells as approved by GE
Taking down the old U/S street light fittings, complete all as specified and directed.
Refixing the old serrviceable street light along with fitting removed from above item complete after minor repair complete all as specified and directed.
Refixing after repair including replacement of suitable LED driver 40 watts serviceable complete all as specified and ditrected .
Refixing after repair including replacement of suitable LED driver 90 watts serviceable complete all as specified and ditrected .
S&F in repalcement of street light fitting Pressure die cast aluminium housing (LM6 Alloy), Minium 9000-10000 Lumens with maximum system wattage 90 W-100 W, with PMMA lenses,External built proper heat shinks and toughtened glass/PC ensuring IP66 & IK>05 protection, LED used shall be SMD type and fixture should have minium efficiency at system level (Not chip level) 100 Lumens/Watt, Life of system should 50000 Hrs all including necessary wire for fitting light to pole all as specified and directed. Make: Philips Cat Part No BRP410 LED 094 CW HE MR FG S2 PSU GR, CG Cat Part No LSTN-100-CDL-A or equivalent in Havells.
S&F in replacement bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5 m long including necessary GI clamps, nuts bolts and washers and connecting with thee core flexible wire of 1.5 sqmm copper conductor to the pole junction box complete all as specified & directed
S&F in replacement of LED security light fitting 40 watt, 3500 lumen, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 sqmm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
S&F in repair danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws, nut bolts with adequate size clamps on HT/LT pole of 25x20 cm size complete all as specified and directed.
M&L in replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion”.
All as per Item No 244 above but using galvanised earth lead wire 4.0mm dia.
S&F in replacement of earth continuity conductor with adequate size saddles fixed to wall on batten or recess or any other indicated situation for loop earthing etc. as required 32mm x 6mm GI strip complete all as specified and directed.
S&F for FRP smart meter box for single phase electric meters -06 Nos will be accomediated with single unit along with weather proof outside cover complete all as specified and directed.
Labour only for 'B' check maintenance/servicing of DG set including replacing of defective wornout parts by new spares such as filters, V belt, engine oil, rubber hoses etc for 62.5 KVA DG set. Note: Fixture/spares Shall be measured & paid seperately under repective items as suuply only.
Supply only diesel filter element with 'O' ring as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only oil filter element with 'O' ring as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only air filter element with 'O' ring as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only fan belt as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only alternator belt as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only rubber hose pipe set complete with clamps as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only engine oil multigrade 20 W 40 complete all as specified and directed.
Supply only inhiibitor corrosion (coolant for radiator) complete all as specified and directed.
S&F in replacement battery lead set PVC insulated multistranded copper conductor 50 Sqmm, 1.25 m long each fixed with brass cladded copper clamps suitable for DG set 62.5 KVA complete all as specified and directed.
Cleaning of fuel tank both internally and externally by removing all the dust/sediments etc, complete all as specified and directed.
Taking down and cleaning the radiator both internally and externally by removing all the dust/sediments and cleaning of capillary tube by pressure and refixing complete all as specified and directed.
Supply only MNX power contactor 415 Volt, 50 Hz, AC of capacity 110 Amps as per sample all as specified and directed
S&F copper wire three core multistrand FRLS 1.5 sqmm complete all as specified and directed.
S&F MCB, SP 5 to 30 Amps, 240 volts bracking capacity 10 KA, ISI marked complete all as specified and directed.
Supply only 10 SQMM 2 Core Aluminium unarmoured, flame resistant PVC flat cable, ISI marked complete all as specified and directed.
S&F PVC/SMC weather proof, hinged door, junction box, size 300mm x 200mm x 100mm with 30A Aluminium bus bar 04 Nos, 240V, Neutral link and 1No MCB SP of 06 Amps, alongwith necessary fixing arrangement such as clamps, nut, bolts, etc complete all as specified and directed.
Material and labour for cleaning and preparation for painting surface of street light steel tubular pole 9mtr long and painting with two coat of aluminum paint including brackets including applying two coats of cement base paint to coping,strip painting up to 1mtr from coping with blue and white colour paint of strips, writing Pole No complete all as specified and directed.
Supply in replacement of unserviceable PVC insulated sheathed cable with stranded Copper conductor of size 2.5 sqmm 3 core from light fitting to junction box complete all as specified and directed
R K CONTRACTOR AND SUPPLIERS
M/S SHIVA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .