SETTING UP OF BIO INCUBATOR FACILITY IN FACULTY OF LIFE SCIENCE AND ENVIRONMENT AT FACULTY BLOCK E
2021_GU_851_1
GU/9/2021-2022/Engg and Tech Div/123
Open Tender
Civil Works - Buildings
Item Rate
270 days
Taleigao Plateau Goa
Please refer Tender documents.
14 documents required · 14 mandatory
₹8,000
₹3.9 L
6 Apr 2022
26 Oct 2021
27 Nov 2021
26 Oct 2021
25 Nov 2021
26 Oct 2021
Amount
CIVIL (A)
Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead.
Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead.
Dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50 meters lead for thickness of tiles 10mm to 25mm.
Dismantling doors, windows and clearestory windows (steel or wood) shutters including chowkhats architrave holdfast etc. complete and staking within 50 mt. Lead
b) Area beyond 3 sq.m.
Brick work using fly ash bricks in cement mortar 1:4 ( 1 cement : 4 coarse sand) with bricks of class designation 40 kg/ cm2 in superstructure up to floor five level
b) 230 x 110 x 80 mm
Providing and laying Autoclave Aerated cement blocks masonry (Light Weight Foam Concrete Blocks) with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Providing and laying cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded granitic or basaltic stone aggregate 20mm nominal size ) excluding cost of centering, shuttering and finishing in superstucture upto floor five level.
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing inn superstucture upto floor five level.
Centering and shuttering including strutting , propping & removal of forms for
iv) sides / soffits of beams, beam haunchings, cantilevers, girders, bressumers and lintels plinth beams not exceeding 1M in depth
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW TMT Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size)
c)In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level
Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in position.
c) first class matti wood
Providing and fixing 35 mm thick panelled glazed or panelled and glazed shutters for doors, windows and clerestory window including 04 no's black enamelled aluminium butt hinges with necessary screws:
b) Second class Indian teak wood
Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with two sliding shutters using 18 mm series shutters section.
(b) Plain glass
Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Adjustable louvered windows.
c)Figured glass
Extra for powder coating with pure polyester powder of shade of required colour on the aluminium section
Providing & fixing anodised aluminium sliding door bolt anidised transparent or dyed required colour and shade with bolts, nuts and screws etc. complete ( ISI mark, Heavy )
Providing and fixing anodized aluminium flat latch
Providing and fixing aluminium tower bolt (barrel type) anodised or dyed to required colour or shade with screws etc complete.
( ISI mark, Heavy )
Providing and fixing aluminium handle anodized or dyed to required colour or shade with screws etc. ( ISI mark, Round, Heavy)
Providing and fixing 150mm bright finished brass floor door stopper with rubber cushion screws etc. to suit shutter thickness complete
Providing and fixing first class Indian teak wood moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surfaces etc.
Providing and Fixing heavy duty flat type door closer
a) Hafele HS1100 MBC/ Godrej
12mm cement plaster 1:4 ( 1 cement : 4 coarse sand )
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1;5 ( 1cement : 5 coarse sand ) and top layer 6 mm thick with cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with sponge
Neat Cement punning
6mm cement plaster to ceiling 1:3 ( 1cement : 3 fine sand)
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coat with ready mixed primer of approved brand and manufacture on WOOD WORK complete
Painting two or more coats (excluding priming coat ) with superior quality ready mixed paint(satin finish) for WOOD WORK of approved brand & manufacture in all shades on NEW WORK to give an even shade
Painting three or more coats with acrylic exterior paint of approved brand and manufacture ( such as weather shield, Apex) including applying one coat of cement primer and one coat of surface treatment etc. complete
Applying one coat of cement primer of approved brand and manufacture on wall surface.
Wall painting ( two or more coats) with plastic emulsion paint of approved brand and manufacture including a priming coat on NEW WORK to give an even shade
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work
Painting two or more coats( excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
Waterproofing of sunken slabs, toilet blocks, terraces on slabs under brickbats, roofs, watertanks. Cleaning the surface and filling cracks (if any), applying EPCO ACR wherever necessary, Providing and Moistening the surface with water to render it saturated. Mix Cement and Monobond WF in the ratio of 1.25 kg to 1 by weight and stir continuously. Apply minimum 2 coats with an interval of 12 hours minimum between the coats. Fix fiber mesh while the first coat is still tacky. Cure with sprinkling of water 3-4 times a day. incl. cost of scaffolding transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent
Providing and fixing vitrified matt finished (600 X 600) and 10 mm thick tiles in floor, treads of steps, and landings on 25 mm thick cement mortar 1:3 and jointed with cement slurry complete(Johnson, somany ,kajaria, Orient bell).
Providing and fixing 1st quality ceramic glazed wall tiles (Johnson, Somany, Kajaria,Orient Bell )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete.
(b)Wall Ceramic Glazed Tiles : 300 x 450
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm
(a)Jet Black
Cuddappah stone slab machine cut flooring over 20mm (average) thickness of cement mortar 1:4 (1 cement : 4 coarse sand laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete - 25 mm thick.
Rounding of edges of granite slab to semi circular slope
Mirror floor polishing and rubbing of existing Kotah tiles including grouting of tiles joint etc. complete
Providing & Fixing of Aluminium Lay-in Perforated Tile Ceiling on 24 /14 mm ‘T’ Framework of module 600mm x 600mm. Tiles of size 575mm X 575mm / 584mm x584mm made out of 0.6mm thick Aluminium. Perforation of the tiles shall be 2.5mm dia 5.5mm c/c. The Tile shall be manufactured on advanced equipment, which includes several levelling. The tile end shall be raised upward by 38mm and bend outward to lay the tile in framework. The Tile shall be Polyester based, powder coated in white colour. Grid system for fixing ceiling tiles shall comprise of Tees. The 24 /14 mm main tee runners shall be suspended at an interval of 1200mm centre to centre. The 24 /14 mm cross tee runner shall be suspended at 600mm centre to centre and further supported with 24 /14 mm cross tee at 600mm centre to centre with interlocking arrangements to form grid of 600mm x 600mm. The main tee shall be supported by means of 4mm G.I. rod from slab/roof. The suspension shall be provided at 1200 to 1500mm centre to centre. Tee framework would be made of GI and Powder coated. Acoustic Felt: Non-woven felt made of glass-reinforced fibre glued over the perforation for sound absorption.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type (BWP), core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
a)35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. of make ASTRAL/ASHIRWAD/FINOLEX
b)20 mm dia nominal outer dia pipes.
c)25 mm dia nominal outer dia pipes.
d)32 mm dia nominal outer dia pipes.
Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement, trenching, refilling and testing of joints complete as per firectionof the Engineer in charge.(External work (heavy duty SDR 11 pipe) of make ASTRAL/ASHIRWAD/FINOLEX
c) 25 mm nominal outer dia pipes
e) 40 mm nominal outer dia pipes
d) 50 mm nominal outer dia pipes.
Making connection of G.I distribution branch with main 50mm to 80mm nominal bore by providing and fixing tee including treading the pipe etc complete.
Providing and fixing P.V.C. connection pipe with brass unions 15 mm nominal bore:
c) 18” (45 cm) length (ARK make)
Providing and fixing C.P concealed angle stop cock (heavy) with wall flange of (ARK SUPREME/JAQUAR) make 15 mm nominal bore
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality. ZOLOTO make
b) 20mm nominal bore
c) 25mm nominal bore
f) 32 mm nominal bore
Providing and fixing Nickel chrome plated copper alloy BIB cock (long body) JAQUAR make with wall flange or ARK SUPREME confirming to IS 8931; 1993
a) 15 mm nominal bore
Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door :
a) 110 mm dia
Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed:
b) 75 mm dia
Providing and fixing Nickel Chrome plated Copper alloy health faucet with 8mm dia 01metre long flexible tube and wall hook a) Jaquar make(JAQ-573)
Providing and fixing CP brass towel rail fixed in wooden clerats with CP brass screws. A) 24" size Jaquar make continental series(JAQ-1111N/continental 2101)
Providing & Fixing Urinal valve auto Closing system CP with built in control Cock with 8 mm dia 300mm long pipe, wall flange etc. complete.Jaquar make(JAQ-077)
Providing and fixing single tee of rigid PVC ( approved make) for SWR pipes including lubricating etc complete with door
b) 75mm dia
Providing and fixing single “Y”of rigid PVC S.W.R pipes (soil, waste & rain water drainage pipes of approved make including lubricant etc. complete ,with door
b) 75 mm dia
Providing and fixing rigid PVC bend ( approved make) for SWR pipes including lubricating etc complete, with door
b) 75mm dia
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 including cutting of stone and making good the walls wherever required : Kitchen sink with drain board with coupling & all accessories complete with choke stop strainer, Plain type having flat borders for correct sandwithing between the plaform top and bottom slabs complete
(a)Overall size 1040mmx510mm (41"x20") bowl size 460mmx410mmx200mm (18"x 16"x 8") depth 200 mm. Glossy. 1.0mm thk,
Steel work welded ( SAIL, TATA, VIZAG & using electrodes of AdOr make only) in built up sections trusses and framed work including cutting, hoisting, fixing in position with anchor fasteners ( Hilti HST) and applying zinc chromite primer
b) In tees, angles ,flats and channels as per the design
Providing and Fixing in position Double Skin Standing Seam MxSeam or equivalant Standing Seam Roofing Sheet in 0.55 mm thickness Color Coated Galvalume / Zincalume Steel Sheets with Galvanised Clips. The feed material is manufactured out of nominal 0.55 mm total coated thickness (TCT) & 0.50 mm base metal thickness (BMT), Hi-tensile steel having 245~300 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 43.5% Zinc & 1.5% Silicon) as per AS 1397 – ZincAl AZ 150 (min. 150 grams / sq. m. total on both sides) with Super Durable Polyester (SDP) Paint finish. The SDP paint will have a total coating thickness of 25 ~ 30 micron, comprising of nominal 20 micron exterior coat on top surface and nominal 5 micron reverse coat on back surface over nominal 5 micron primer coat on both surfaces of approved color shade by concern authority. The profile sheet will be of TATA BlueScope Steel (TBSL) or JSW SDP or Equivalent make, necessary Test Certifcate has to be provided. Top Skin elements to be supplied in single length with no laps with a sheet element cover width of 480 mm and a standing seam height of 45 mm. Sheets are to be laid to meet the requirements of the building geometry. The roof elements will be supported by and joined longitudinally with an electrically operated closure machine over concealed galvanised clips integrated into the longitudinal element flange thereby allowing for the possibility of transmitting reaction forces resulting from positive and/or negative loads and also accommodating unobstructed thermal movements resulting from the specific ambient temperature variation.The secret fix galvanised clips shall be capable of transmitting all reaction forces to the purlin without the aid of any other material, thus resulting in an overall “Self-supporting standing seam roof system”. Base Coil : TBSL or JSW SDP or Equivalant make. Rockwool Insulation layer of 50 mm thick, 48kg/m3 density to be laid between two sheets. "Z" Type GI Sub-girt of size 40 x 50 x 40 – 1.5 mm thick will be fixed on liner sheets at all along purlin, the height of 50 mm will cater the thickness of 50 mm thick insulation. Liner Sheets shall be of MxLine or equivalant Profile of having nominal 1050 mm effective cover width and 18 mm corrugation depth at 175 mm center to center spacing in Colour Coated Galvalume / Zincalume Steel materials. The feed material is manufactured out of nominal (0.42 mm BMT) 0.50 mm total coated thickness (TCT), Hi-tensile steel with minimum 550 MPa yield strength, metallic hot dipped coated with Aluminium Zinc alloy (55% Aluminium, 43.3% Zinc & 1.6% Silicon) as per AS 1397 - Zinc-Alu. AZ 150 (min. 150 grams/ sq. m. total on both sides) with Super Durable Polyester (SDP) Paint. The paint will have a total coating thickness of nominal 25 µm, comprising of nominal 20 µm exterior coat on top surface andnominal 5 µm reverse coat on back surface over nominal 5 µm primer coat on both surfaces of approved colour shade by concern authority. the steel sheet shall be fastened with nominal 40 micron zinc coated or nominal 25 micron zinc-tin allow coated , hex head, self drilling screw as per aAS 3566-2002 Class -3 fastners of approved make with EPDM washers as per the requirement considering the profile shape and design load. the fastnes size shall be calculated as per the design or manufacturers recommendations.
Add for providing and fixing Flashings- (corners,ridges,valleys, gable end and trims) ( Girth up to 610 mm ) including all the accessories complete as per the directions of the Engineer in Charge.
Providing and fixing M.S grill of required pattern in wooden frames of windows etc with M.S flats square or round bars with round headed bolts and nuts or by screws.
a) Plain grill
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Extra for providing vision panel not exceeding 0.1 sq.m. in all types of flush doors (cost of glass excluded).
a)Rectangular or square Unit: SQ.M. door area
ELECTRICAL WORKS (B)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
(f) Group C -- with Cat B Modular Accessories
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required.
(b) Cat B
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 15/16 A modular socket outlet and 15/16 A modular switch connection painting etc. as required.
(b) Cat B
Supplying and fixing 20 A 240 V SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top along with 20 A, C series SP MCB in sheet steel enclosure in surface or in recess with chained metal cover for the socket outlet and complete with connections testing and commissioning etc. as required" (b) Cat B
Supplying and fixing 20 A 415 V TPN industrial type socket outlet with4 pole and earth metal enclosed plug top along with 20 A, C series TP MCB in sheet steel enclosure in surface or in recess with chained metal cover for the socket outlet and complete with connections testing and commissioning etc. as required" (b) Cat B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit (heavy)of appropriate size as required.
(b)2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
(i) 4 x 4 sq.mm + 2 x 4 sq.mm earthwire (25mm Conduit )
(j) 4 x 6 sq.mm + 2 x 6 sq.mm earthwire (32mm Conduit )
(l) 4 x 16 sq.mm + 2 x 16 sq.mm earthwire (40mm Conduit )
(m) 4 x 25 sq.mm + 2 x 25 sq.mm earthwire (50mm Conduit )
Supply installation testing and commissioning of flush mounted 7 segment phase segregated type mcb db as per IS 8623-1&3 with hinged cover door with modular incomer suitable for 60A fourpole mcb , subincomers suitable for 40A/50A DP MCB + ELCB 30mA and insulated/shrouded bus bars for three phases and earth bars and each phase with following outgoings suitable for following mcbs suitable for connections to various circuits as shown complete with colour coded interconnecting wire set, cables ties, circuit identification labels etc
4 nos of SP outgoing 6/10/15A MCB per phase PDB3 as above
Supply installation testing and commissioning of flush mounted 7 segment phase segregated type mcb db as per IS 8623-1&3, IP54 with hinged cover door with modular incomer suitable for 60A fourpole mcb , subincomers suitable for 50/40A DP MCB+RCBO 30mA and insulated/shrouded bus bars for three phases and earth bars and each phase with following outgoings suitable for following mcbs suitable for connections to various circuits as shown complete with colour coded interconnecting wire set, cables ties, circuit identification labels etc
6 nos of SP outgoing 6/10/15A MCB per phase DB1
Supply installation testing and commissioning of flush mounted 7 segment phase segregated type mcb db as per IS 8623-1&3, IP54 with hinged cover door with modular incomer suitable for 60A fourpole mcb , subincomers suitable for 40A DP MCB+RCBO 30mA and insulated/shrouded bus bars for three phases and earth bars and each phase with following outgoings suitable for following mcbs suitable for connections to various circuits as shown complete with colour coded interconnecting wire set, cables ties, circuit identification labels etc
8 nos of SP outgoing 6/10/15A MCB per phase (PDB2 and PDB5)
Supply installation testing and commissioning of flush mounted 7 segment phase segregated type mcb db as per IS 8623-1&3, IP54 with hinged cover door with modular incomer suitable for 60A fourpole mcb , subincomers suitable for 40A DP MCB+RCBO 30mA and insulated/shrouded bus bars for three phases and earth bars and each phase with following outgoings suitable for following mcbs suitable for connections to various circuits as shown complete with colour coded interconnecting wire set, cables ties, circuit identification labels etc
12 nos of SP outgoing 6/10/15A MCB per phase PDB2 as above
Supplying and fixing following way TPN sheet steel, double door, Vertical type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphatized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)interconnection between incomer MCB and busbars of following ways (but without MCBs as required)
(a) 4 way (8+12), double door, Vertical type, Cat A
(b) 8 way (8+24), double door, Vertical type, Cat A
(c) 12 way (8+36), double door, Vertical type, Cat A
Supplying and fixing B series SP MCB 240V, suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required"
(c )5A TO 32A, Cat B
Supplying and fixing 40 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
(h) DP, Cat B
Supplying and fixing 50 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
(h) DP, Cat B
Supplying and fixing following rating four pole (triple pole and neutral) 415 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required
(e) 40 A, Cat B
Supplying and fixing 63 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
(j) TPN, Cat B
Supply installation testing and commissioning of cable end box of CRCA sheet, RAL 9003, powder coated, either top or bottom, suitable for cable shown on drawings for VTPN DBs etc
'Supply installation testing and commissioning of cable end box of CRCA sheet, RAL 9003, powder coated, either top or bottom, suitable for cable shown on drawings for Phase segregated db
4 way DB
Supply installation testing and commissioning of cable end box of CRCA sheet, RAL 9003, powder coated, either top or bottom, suitable for cable shown on drawings for Phase segregated 6 way DBs etc
Supply installation testing and commissioning of cable end box of CRCA sheet, RAL 9003, powder coated, either top or bottom, suitable for cable shown on drawings for Phase segregated 8 way DBs etc
Supply installation testing and commissioning of cable end box of CRCA sheet, RAL 9003, powder coated, either top or bottom, suitable for cable shown on drawings for Phase segregated 12 way DBs etc
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required
Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I),IS:7098(Part I) with latest amendments of following size.
(1) 3 1/2Core25 sq.mm
(3) 3 1/2Core50 sq.mm
(4) 3 1/2Core70 sq.mm
(5) 3 1/2Core95 sq.mm
(9) 3 1/2Core240 sq.mm
(10) 3 1/2Core300 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in existing RCC/HUME/Stoneware/Trench/Metal pipe etc complete as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25sq but not exceeding 400 sq.mm in existing RCC/HUME/Stoneware/Trench/Metal pipe etc complete as required.
Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.
(1) 3 1/2Core25 sq.mm
(4) 3 1/2Core50 sq.mm
(5) 3 1/2Core95 sq.mm
(10) 3 1/2Core240 sq.mm
(11) 3 1/2Core300 sq.mm
Supplying and Installing following size perforated type 14 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(a)450mm width x 50mm depth
(b)600mm width x 50mm depth
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(a)100mm width x 50mm depth
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(d)300mm width x 50mm depth
Supplying and Installing following size perforated type , M.S.cable tray bends of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(f)600mm width x 50mm depth (14 SWG)
Supplying and Installing following size perforated type , M.S.cable tray reducers of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(f)600mm width x 50mm depth (14 SWG)
Supplying and Installing following size perforated type , M.S.cable tray tees of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(f)600mm width x 50mm depth (14 SWG)
Supplying and Installing following size perforated type 16 SWG, M.S.cable tray bends of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(a)100mm width x 50mm depth
Supplying and Installing following size perforated type , M.S.cable tray reducers of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(e)450mm width x 50mm depth (14 SWG)
Supplying and Installing following size perforated type , M.S.cable tray tees of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(a)100mm width x 50mm depth (16 SWG)
Supplying and Installing following size perforated type , M.S.cable tray tees of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
450mm width x 50mm depth (14 SWG)
Providing and fixing following rating and breaking capacity adjustable 4 pole MCCB inside the existing cubicle panel board including drilling holes in cubicle panel making connections etc as required
(e) 250 A Adjustable 35/40 KA, CAT A
(f) 400 A Adjustable 35/40 KA, CAT A
(g) 630 A Adjustable 35/40 KA, CAT A
Supply, Installation, testing and commissioning of suitable enclosure for 250A/300A TPN MCCB suitable for incoming & outgoing 3 1/2 x 300 sqmm AYFY cable complete with wall mounted arrangement.
Supplying and Installing following size welded ladder type , 50mm depth, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(f)600 mm width X 50 mm depth with runner size 15x50x15mm, rung size 20x40x20mm with rungs at 250mm c/c.(12SWG)
Supplying and Installing following size welded ladder type , 50mm depth, M.S.cable tray bend of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
(f)600 mm width X 50 mm depth with runner size 15x50x15mm, rung size 20x40x20mm with rungs at 250mm c/c.(12SWG)
Design , supply ,installation testing and commissioning of LAB panel cubical type ,wall mounted , front access ,fully compartmentalised with cable entry at top/ bottom, all mccbs with rotary handles with thermal magnetic releases. Steel sheets used in the construction shall be 2 mm thick. All sheet steel work shall undergo a process of degreasing, pickling in acid, cold-rinsing, phosphating, passivating and then sprayed with a high corrosive resistant primer. The finishing treatment shall be by application of two coats of synthetic enamel paint or powder coating of RED colour. The panel shall be of adequate size with a provision of 25% spare space to accommodate possible future switch gear. The cable terminations shall be suitable for cable sizes as shown on the drawing as required etc and suitable for outgoing cable sizes as shown on the drawing as required with
Incomer 300A 4P 50KA mccb with thermal magnetic releases
1 sets of digital multifunction meter with Amps, Volts, Kwh, Hz,PF etc with scada connectivity with necessary cts and suitable RS485/232 port
800A 4P copper bus bars of 99.9% purity electrolytic copper
Outgoings
1 set of 63A , 25KA TPN MCCBs
3 set of 100A , 25KA TPN MCCBs
1 set of 200A , 25KA TPN MCCBs
LAB2 Raw Power panel as above
Design , supply ,installation testing and commissioning of LAB DG back up panel, cubical type ,wall mounted , front access ,fully compartmentalised with cable entry at top/ bottom, all mccbs with rotary handles with thermal magnetic releases. Steel sheets used in the construction shall be 2 mm thick. All sheet steel work shall undergo a process of degreasing, pickling in acid, cold-rinsing, phosphating, passivating and then sprayed with a high corrosive resistant primer. The finishing treatment shall be by application of two coats of synthetic enamel paint or powder coating of RED colour. The panel shall be of adequate size with a provision of 25% spare space to accommodate possible future switch gear. The cable terminations shall be suitable for cable sizes as shown on the drawing as required and suitable for outgoing cable sizes as shown on the drawing as required with
Incomer 100A 4P 50KA mccb with thermal magnetic releases
1 sets of digital multifunction meter with Amps, Volts, Kwh, Hz,PF etc with scada connectivity with necessary cts and suitable RS485/232 port
800A 4P copper bus bars of 99.9% purity electrolytic copper
Outgoings
4 set of 63A , 25KA TPN MCCBs
LAB DG back up panel as above
LAB2 DG back up panel as above
Design , supply ,installation testing and commissioning of 2nd Floor DG Back up Panel cubical type ,wall mounted , front access ,fully compartmentalised with cable entry at top/ bottom, all mccbs with rotary handles with thermal magnetic releases. Steel sheets used in the construction shall be 2 mm thick. All sheet steel work shall undergo a process of degreasing, pickling in acid, cold-rinsing, phosphating, passivating and then sprayed with a high corrosive resistant primer. The finishing treatment shall be by application of two coats of synthetic enamel paint or powder coating of RED colour. The panel shall be of adequate size with a provision of 25% spare space to accommodate possible future switch gear. The cable terminations shall be suitable for cable sizes as shown on the drawing as required etc suitable for outgoing cable sizes as shown on the drawing as required with
Incomer 300A 4P 50KA mccb with thermal magnetic releases
1 sets of digital multifunction meter with Amps, Volts, Kwh, Hz,PF etc with scada connectivity with necessary cts and suitable RS485/232 port
2000A 4P copper extensible bus bars of 99.9% purity electrolytic copper
Outgoings
1 set of 200A , 25KA TPN MCCBs
1 set of 125A , 25KA TPN MCCBs
2 set of 100A , 25KA TPN MCCBs
3 set of 63A , 25KA TPN MCCBs
Second Floor DG backup Power panel as above
Second Floor DG backup Power panel as above
Design , supply ,installation testing and commissioning of 2nd Floor Raw Power Panel cubical type ,wall mounted , front access ,fully compartmentalised with cable entry at top/ bottom, all mccbs with rotary handles and 25KA with thermal magnetic releases. Steel sheets used in the construction shall be 2 mm thick. All sheet steel work shall undergo a process of degreasing, pickling in acid, cold-rinsing, phosphating, passivating and then sprayed with a high corrosive resistant primer. The finishing treatment shall be by application of two coats of synthetic enamel paint or powder coating of RED colour. The panel shall be of adequate size with a provision of 25% spare space to accommodate possible future switch gear. The cable terminations shall be suitable for cable sizes as shown on the drawing as required etc suitable for outgoing cable sizes as shown on the drawing as required with
Incomer 800A 4P 50KA mccb with microprocessor release
1 sets of digital multifunction meter with Amps, Volts, Kwh, Hz,PF etc with scada connectivity with necessary cts and suitable RS485/232 port
2000A 4P copper extensible bus bars of 99.9% purity electrolytic copper
Outgoings
2 set of 320A , 36KA TPN MCCBs
2 set of 200A , 36KA TPN MCCBs
5 set of 63A , 25KA TPN MCCBs
Second Floor Raw Power panel as above
Design , supply ,installation testing and commissioning of LAB panel cubical type ,wall mounted , front access ,fully compartmentalised with cable entry at top/ bottom, all mccbs with rotary handles ,with thermal magnetic releases. Steel sheets used in the construction shall be 2 mm thick. All sheet steel work shall undergo a process of degreasing, pickling in acid, cold-rinsing, phosphating, passivating and then sprayed with a high corrosive resistant primer. The finishing treatment shall be by application of two coats of synthetic enamel paint or powder coating of RED colour for incomer door and RAL7032 for others. The panel shall be of adequate size with a provision of 25% spare space to accommodate possible future switch gear. The cable terminations shall be suitable for cable sizes as shown on the drawing as required etc suitable for outgoing cable sizes as shown on the drawing as required with
Incomer 200A 4P 25KA mccb with thermal magnetic releases
1 sets of digital multifunction meter with Amps, Volts, Kwh, Hz,PF etc with scada connectivity with necessary cts and suitable RS485/232 port
400A 4P copper bus bars of 99.9% purity electrolytic copper
Outgoings
1 set of 63A , 25KA TPN MCCBs
3 set of 100A , 25KA TPN MCCBs
1 set of160A , 25KA TPN MCCBs
LAB1 Raw Power panel as above
Design , supply ,installation testing and commissioning of TP Sockets panel ,cubical type, wall mounted , front access ,fully compartmentalised with cable entry at top/ bottom, all mccbs with rotary handles and 25KA with thermal magnetic releases.>> >>Steel sheets used in the construction shall be 2 mm thick. All sheet steel work shall undergo a process of degreasing, pickling in acid, cold-rinsing, phosphating, passivating and then sprayed with a high corrosive resistant primer. The finishing treatment shall be by application of two coats of synthetic enamel paint or powder coating of RAL7032. The panel shall be of adequate size with a provision of 25% spare space to accommodate possible future switch gear. The cable terminations shall be suitable for cable sizes as shown on the drawing as required>> <<
Incomer 63A TPN 25KA mccb with thermal magnetic releases
1 sets of digital multifunction meter with Amps, Volts, Kwh, Hz,PF etc with scada connectivity with necessary cts and suitable RS485/232 port
400A 4P copper bus bars of 99.9% purity electrolytic copper
Outgoings
5 set of 20A FP mcb and 30mA FP elcb
TP Sockets panel as above
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 25 W-32W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting of ceiling fan of 1200mm sweep , double ball bearing type,completewith all accessories
Supply and erecting S type Mild steel fan hook fabricated out of 12mm round bar complete with painting as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
(b)'Cat B
Supplying and fixing extra conduit down rod of 20 mm dia 2 X 10 cm length wiring with 2 X 1.5 sq. mm FR PVC insulated copper conductor single core cable including painting etc. as required.
Supply and erecting of 12 inch (300 mm sweep) exhaust fan, 1400 rpm, complete with all accessories.(a) Cat A
Supplying and fixing 3 pin 5A ceiling rose on the existing junction box/ wooden block including connections
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required
Supplying installing, testing and commissioning of suitable size modular plate and cover complete with RJ45 connector (modular LAN socket TX1000 CAT6) including concealed metal box/ surface GI/PVC box , modular plate punching, identifying complete as required
(b)'Cat B
Supplying and drawing of Cat-6 UTP, 4 pair annealed tinned copper conductor PVC insulated, PVS sheathed, unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection, etc. complete as required
Cat 6 Cable
Supplying, installing and Testing and Commissioning UTP connector (RJ45) as per specification No. WG-NAS/UTPC
Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.
C ( HVAC)
Supplying, installing, testing and commissioning of Outdoor type Air-cooled Condensing units of capacity not less than 11 tons of BLUE STAR / VOLTAS / DAIKIN make each having single scroll compressor, copper tube aluminium finned condenser coil with special weather protective coating, condenser fans, mounting frame epoxy coated/painted, Temperature controller for automatic ON-OFF of compressors with sensor, vibration isolators and first charge of environment friendly refrigerant and oil.
Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1 TR capacity having ISEER minimum 4.50 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no of air handling unit Hi-wall type complete with refrigerant R410 A/R32 and copper condensor at position. specification no.APAC/ SAC
Supplying, installing, testing and commissioning cassette type variable speed Inverter technology split room Air conditioning unit 2 TR capacity having ISEER minimum 3.50 to maximum 3.99 suitable to operate on 230/250V, 50 cycles, A.C. supply having 1 no of air handling unit false ceiling mounting type complete with refrigerant R410 A/R32 and copper condensor coil at position.
Supplying, installing, testing and commissioning cassette type variable speed Inverter technology split room Air conditioning unit 3 TR capacity having ISEER maximum 4.50, suitable to operate on 230/250V, 50 cycles, A.C. supply having 1 no of air handling unit false ceiling mounting type complete with refrigerant R410 A/R32 and copper condensor coil at position.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for suction line piping of suitable gauge (hard drawn copper pipe for liquid main line and for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with AC piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge (hard drawn copper pipe for liquid main line and for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with AC piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge (hard drawn copper pipe for liquid main line and for refrigerant) along with necessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with AC piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge (hard drawn copper pipe for liquid main line and for refrigerant) along with necessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with AC piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line piping of suitable gauge (hard drawn copper pipe for liquid main line and for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with AC piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of air conditioning system.
Supply, fabrication, installation and testing of machine made sheet metal ducts fabricated from 24 gauge (0.63 mm thickness) galvanized steel sheets of TATA/JINDAL make complete with joints, galvanized angle supports with full threaded rods, anchor fastners, 4 mm thick neoprene rubber gaskets, etc. as per the approved shop drawing and as required by BIS requirements. Scope shall include air balancing and submission of report. Payment shall be made for the surface area of installed ducts with measurements taken along the center line of ducts on a linear basis with no additional payment for bends/transitions.
Supply, fabrication, installation and testing of machine made sheet metal ducts fabricated from 22 gauge (0.8 mm thickness) galvanized steel sheets of TATA/JINDAL make complete with joints, galvanized angle supports with full threaded rods, anchor fastners, 4 mm thick neoprene rubber gaskets, etc. as per the approved shop drawing and as required by BIS requirements. Scope shall include air balancing and submission of report. Payment shall be made for the surface area of installed ducts with measurements taken along the center line of ducts on a linear basis with no additional payment for bends/transitions.
Supply, fabrication, installation and testing of machine made sheet metal ducts fabricated from 20 gauge (1.0 mm thickness) galvanized steel sheets of TATA/JINDAL make complete with joints, galvanized angle supports with full threaded rods, anchor fastners, 4 mm thick neoprene rubber gaskets, etc. as per the approved shop drawing and as required by BIS requirements. Scope shall include air balancing and submission of report. Payment shall be made for the surface area of installed ducts with measurements taken along the center line of ducts on a linear basis with no additional payment for bends/transitions.
Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction complete with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
Supply, installation testing and commissioning of fire dampers complete with fusible link, spring, etc. at locations shown in approved shop drawings and as per specifications
a)Fire Dampers
b)Fusible Links
Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete
Providing adhesive thermal insulation for supply / return air duct with Class 'O' grade 19 mm nitrile rubber insulation with plain finish having R-value as per the prevailing provisions in ECBC-2007.
Providing adhesive thermal insulation for supply / return air duct running outside the building with Class 'O' grade 25 mm nitrile rubber insulation with FC finish of ARMAFLEX / KFLEX make joints fully sealed with adhesive.
Supplying and erecting aluminium powder coated Supply air grilles of required rectangular size with volume control dampers suitable for deflection of 15/30/45 degree and complete with all installation hardware.
Supplying and erecting aluminium powder coated Return air grilles of required rectangular size without volume control dampers suitable for deflection of 15/30/45 degree and complete with all installation hardware.
Supplying and erecting aluminium powder coated Supply air Diffusers of required square size with removable core and volume control dampers and complete with all installation hardware.
Supplying and erecting aluminium powder coated Return air Diffusers of required square size without volume control dampers and complete with all installation hardware.
Providing & fixing in position condensate drain piping with heavy class UPVC pipes cut to required lengths and installed with all necessary elbows, adhesive, MS painted supports, etc. as per site requirement and finished with 9 mm thick nitrile rubber insulation having glass cloth protection.
a)50 mm dia Drain Piping
b)32 mm dia Drain Piping
c)25 mm dia Drain Piping
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. copper conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 3 core 2.5 sq. mm. copper conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 400 mm width & 75 mm height comprising all required standard accessories.
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height comprising all required standard accessories.
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height comprising all required standard accessories.
Supply, installation, testing and commissioning of Remote ON/OFF Push-Button stations inside each LAB for daily switching ON and OFF the AC system. Copper cable 3C x 2.5 sq mm is measured separately.
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I),IS:7098(Part I) with latest amendments of following size.
(5) 3 1/2cx95 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25sq but not exceeding 400 sq.mm in existing RCC/HUME/Stoneware/Trench/Metal pipe etc complete as required.
Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.
(5) 3 1/2cx95 sq.mm
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .