Amount
pH Meter (Digital)
Purpose For analysis of pH and Redox potential of water samples in the laboratory Specifications Functions Measurement of pH, mV Display 4 digit LCD/LED pH Meter
• Range: 0-14
• Accuracy: 0.01 pH unit
• Resolution: 0.01 pH unit
• Multipoint calibration (5 points) mV Meter
• Range: 0-1000
• Resolution: 0.01 mV
• Accuracy 0.05 mV Temperature Compensation
• 0 to 100°C, manual and automatic Calibration
• 220 VAC ±10%, 47 to 53 Hz • Dual power (battery/AC Power) Accessories
• Two electrodes with silicon body (one spare)
• Electrode stand
• Carrying case for transportation in field • Operation manual
• Three buffer solutions for calibration i.e. pH 4, pH 7, pH 9 and dust cover
TURBIDITY METER (NEPHELOMETER)
Purpose
For direct measurement of suspended matter, e.g. turbidity of water samples and analysis for sulphate
Specifications
range 0 to 1000 NTU, in at least 2 ranges
accuracy ±2% Full Scale deflection
power supply 220 VAC ±25%, 47 to 53 Hz
Accessories
ambient light shield
spare tubes (6 Nos)
stand for sensor
voltage stabiliser
instruction manual
dust cover
BALANCE, ANALYTICAL (ELECTRONIC)
Purpose
For preparation of standard solutions used in chemical analysis.
Specifications
Type electronic, single pan
capacity up to 200 g
resolution 0.1 mg
pan size approximately 80 mm diameter
display LCD
power supply 220 V ±25%, 47 to 53 Hz AC Power
Features
auto zero tare function
removable stainless steel tray
overload protection
auto calibration facility
Accessories
set of certified calibration weights (0 to 200 gm. Full range)
voltage stabiliser
dust proof cover
necessary tools
operation manual
CONDUCTIVITY/TDS METER(DIGITAL)
Purpose
For laboratory measurements of electrical conductivity
Specifications
conductivity cell glass body with platinum electrodes
cell constant approx. 1
resolution 0.1 mS/cm, lowest scale
accuracy 1% of range
temp. compensation 0 to 50°C, automatic / manual
display LCD
reading conductivity and temperature
power supply 220 VAC ±25%, 50 Hz
Accessories
voltage stabilizer
clamp and stand
operation manual
dust cover
FILTRATION ASSEMBLY FOR MEMBRANE FILTERS
Purpose
For quantitative analysis of coliform bacteria.
Specifications
type filtration assembly consisting of funnel, filter support and filtrate flask
size for 47 mm diameter filters
filtrate flask capacity 1 litre
vacuum connection 6 mm o.d.
funnel 300 ml, 76 mm
material glass or stainless steel or porcelain or autoclavable plastic
Features
detachable filter seat (porous plate)
funnel and filter support should make air and water tight joint
Accessories
MF stainless steel forceps
Consumables
500 membrane filters (0.45 mm , 47 mm)
500 absorbent pads (47 mm)
INCUBATOR, BACTERIOLOGICAL
Purpose
For incubation in bacteriological analysis
Specifications
inner size approx. 0.5 x 0.5 x 0.5 m (h x w x d)
material inside stainless steel chamber
hot enameled outside
range 35 to 60 °C, thermostatically controlled
accuracy ±1.0 °C
power supply 220 VAC ± 25%, 47 to 53 Hz, approx. 400 Watt
display digital display
Features
3 shelves
high quality insulation between inner chamber and outer wall
full length inner glass door with roller type latch for monitoring without disturbing inside temperature
thermometer access hole to display inside temperature
Accessories
suitable thermometer having 0.1 °C graduation
Operation Manual
HOT AIR OVEN
Purpose
For drying, heating and evaporating different kinds of glassware, samples and chemicals in a laboratory
Specifications
inner size approx. 0.6 x 0.5 x 0.5 m (h x w x d)
material stainless steel inside stove enameled outside
temperature range ambient to 250°C
temperature setting thermostatically controlled
up to 80°C; ±2oC accuracy;
80 to 250°C; ±1°C accuracy
temperature reading built in digital display thermometer
timer up to at least 2 hours and adjustable in multiples of 15 mins. or less
power supply 220 VAC ±25%, 47 to 53 Hz, single phase, approx. 2000 Watt
Features
double walled, highly insulated
pilot lamp for thermostat operation
3 shelves at adjustable height
ventilation
door with high quality hinges
roller type latch
Operation manual
REFRIGERATOR
Purpose
For cooling and storage of (standard) solutions in a laboratory.
Specifications
type vertical double door
capacity approx. 280 litre
power supply starting automatic frost free voltage 160 to 260 VAC, 47 to 53 z
running voltage 140 to 280 VAC, 47 to 53 Hz
temperature continuous constant temperature at 4°C
Features
built in voltage stabiliser
2 doors and 3 trays
self draining defrosting
PUF insulation
locking system
Operation manual
UV- Visible Spectrophotometer
Purpose
To carry out spectrophotometric measurements in Laboratory in UV range Specifications: Brief Description
• Computer controlled spectrophotometer which can be used with, rectangular cells of up to at least 10 mm thickness, and sipper flow through cell, having following specifications, dual display system Optical System
• Double beam grating based single detector or dual display system Wave Range
• 190 to 1100 nm Wave length readability
• Better than or equal to 0.2 nm Accuracy
• Better than or equal to ± 0.5 nm Scan speed
• 1-3800 nm/min Wavelength repeatability
• Better than or equal to ± 0.2 nm Photometric readout
• Provisions should include at least 2.0 nm SBW (slit band width) Scan speed • Should be wide range 1 to 3800 nm/minute (variable) Photometric Range
• Should cover -0.500 A to + 3.0 A range Photometric Accuracy
• Better than 0.5% T or 0.005 A Noise
• Better than 0.0002 A at 500 nm Data interval • 0.2, 0.5, 1.0, 2.0, 4.0, 10.0 nm Drift • 0.0002 A/hour after warm up Cell Holder
• For holding upto 50 nm pathlength rectangular cuvette Interface • RS-232 C/USB Power Supply
• 220 VAC ±10%, 47 to 53 Hz AC Quality Certificate
• Installation qualification, operational qualification and performance qualification certificate from NABL Accredited Laboratory or US-EPA certificate of performance Accessories
• Two pairs of square glass cuvettes (10 mm pathlength), Operation and maintenance manual (English), Dust cover, Power cable with plug to suit Indian socket
• Computer (Pentium I3, at least 2 GB RAM, 360 GB HDD with necessary softwares
• Printer (internal) Laserjet suitable for graphs/data printing
• Rectangular cuvettes (50 mm & 25 mm pathlength) • Other accessories needed for calibration Consumables
• For two years of operation, printer ribbons etc considering the expiry dates Additional Features
• The system should provide facility for the storage of spectra/methods, multi wavelength mode, baseline correction, peak area and other statistical calculations. Software should be provided for water & environmental analysis along with user friendly programme softwares.
HOT PLATE
Purpose
For heating of solutions in a laboratory
Specifications
size approx. 0.3 x 0.45 m (l x w)
temperature range ambient to 300 °C, thermostatically controlled
top plate material cast iron, body hot enameled mild steel
power supply 220 VAC ±25%, 47 to 53 Hz
Features
2000 Watt spiral heaters of best quality with porcelain beads insulation, embedded in top plate
power indicator light
AUTOCLAVE
Purpose
For sterilization of glasswares and culture media for bacteriological analysis
Specifications
size 0.3 x 0.5 m (diameter x height)
material stainless steel inside and lid
hot enameled outside
working pressure adjustable to 1 bar
max. pressure 1.5 bar
power supply 220 VAC ±25%, 47 to 53 Hz, single phase, approx. 2500 Watt
Accessories
pressure gauge
steam release cock
safety valve
aluminium perforated basket
water level indicator
lifting arrangement
Operation manual
STIRRER, MAGNETIC (WITH HOT PLATE)
Purpose
For general use in a laboratory
Specifications
rotation speed 0 to 1200 rpm, electronically controlled
heating element 300 Watt, thermostatically controlled
power supply 220 VAC ±25%, 47 to 53 Hz
Features
stainless steel top
Accessories
PTFE (Teflon) coated magnets, size 10 mm to 50 mm, increasing with 5 mm, two of each
Operation manual
VACUUM PUMP
Purpose
For general use in a laboratory
Specifications
type single stage
capacity 50 l/min free air displacement
final vacuum (no ballast) 0.05 mm Hg (6.66 Pa)
final vacuum with ballast 2 mm Hg (267 Pa)
motor rating 200 W (0.25 HP)
power supply 220 VAC ±25%, 47 to 53 Hz
Accessories
moisture and oil filter
vacuum regulator
vacuum gauge
10 m hose pipe of standard size
non-return valve
Features
noise free operation
Operation Manual
WATER BATH, BACTERIOLOGICAL
Purpose
For incubation of culture tubes in coliform analysis
Specifications
inner size approximately 0.4 x 0.3 x 0.15 m (l x w x d)
material stainless steel inside, stove enameled outside
temperature range ambient to 50°C, thermostatically controlled
accuracy ±0.1°C
power supply 220 VAC ±25%, 47 to 53 Hz
Accessories
mercury filled thermometer having 0.1oC graduation
Features
double wall, highly insulated
dome lid to accommodate test tubes in vertical position
pilot lamp for thermostat operation
thermometer access hole to display inside water temperature
Operation manual
DOUBLE DISTILLATION UNIT
Purpose
For generation of reagent water type II, for routine analysis
Conditions and requirements
The conductivity after distillation shall be equal or less than 1.0 mS/cm at 25°C
Specifications
material quartz glass, thermal shock resistant
capacity 1.5 litres/h
power supply 220 VAC ±25%, 47 to 53 Hz, approx. 1 kW
Accessories
sturdy metallic stand with supporting ring clamp for condenser
operation manual
Features
glass embedded heating element with over-heating protection
switch and neon indicator light for power
THERMOMETERS
Purpose
For measuring temperature of solutions and water samples in a laboratory
Specifications
type mercury filled glass made
range three ranges: 0-80oC, 10-150oC, 20-250oC
accuracy ±0.5oC
Accessories
Storage box
Laminar Air Flow
Purpose
Laminar flow in a bench used in microbiological inoculation. It keeps sterile atmosphere to carry out microbiological inoculations.
Conditions & Requirements: The bench shall be compatible with the climatic and other environmental conditions of Indian laboratories Specifications:
Description • Horizontal laminar flow conforming to class 100 conditions of the U.S. Federal Standards 290 B Work area
• Bench of 120 cm X 60 cm X 60 cm, with white sunmica top Principle
• Double filtration of air and provision for UV light to make work area microbe free Filters • Filters with at least 98% efficiency for particles of 0.3 µM or larger size Housing
• Wood or melamine or equivalent
• Blower: 220 VAC ±10%, 47 to 53 Hz
• UV Lamp and other fluoroscent light: 220 VAC ±10%, 47 to 53 Hz with certification
• Provision for a UV tube light and a fluorescent tube light • Tested for leaks and certified • Blower: Dynamically balanced, and with at least 0.25 Horse Power electric motor operating on 220 VAC ±10%, 47 to 53 Hz AC power supply
• Static pressure manometer to measure the air flow rate Method
• To avoid contamination during microbial inoculation, filtered air is blown on work bench from opposite side to make the working environment microbe free.
• The filtration of air is performed through filters having pore size < 0.3 µM Operation and Performance
• The filtration of air is performed through filters having • Pore size < 0.3 µM • Air flow: 3 m3 per minute
• Noise: Less than 65 db at work area • Vibration free work table • Light level: More than 100 feet candle in work area
• Filtration with 98% removal of suspended particles of 0.3 µM size or bigger
• Installation qualification, operational qualification and performance qualification certificate from NABL Accredited Laboratory or US-EPA certificate of performance Accessories
• Spare UV tube light
• Static pressure inclined manometer
Operation manual
STABILISER
Purpose
For protection of sensitive instruments as per instruments requirement
Specifications
type ferro magnetic resonance type constant voltage transformer
capacity approx. 1 to 3 kVA, depending on capacity of instrument or group of instruments supported
input voltage 170 to 270 VAC, 50 Hz ± 5%
output 220 VAC ± 2%, 50 Hz
efficiency > 85%
Features
Meters for reading of input and output voltage
WATER GEYSER (HEATER)
Purpose
· For heating water for general use in a laboratory
Specifications
capacity 120 litres
temperature 90°C, thermostatically controlled
power supply 220 VAC ±25%, 47 to 53 Hz
FIRE EXTINGUISHER, CO2
Purpose
· For rapid extinguishing of small fire
Specifications
type CO2
capacity to be defined in relationship to the work, the work area and abundance and type of flammable material
Operation manual
Glass ware Borosil recommended Ist grade as under:-
(i)Burette (50ml) Straight bore stopcock= 3 Nos.
(ii)Conical flask.
(a)100ml.= 10 Nos.
(b) 250ml.= 10Nos.
(C) 500ml.= 2 Nos.
(d)1000ml= 1 Nos.
(iii)Graduated pipette.
(a)10ml.capacity.= 5 Nos.
(b) 5ml.capacity. = 5 Nos.
© 2 ml.capacity.= 5Nos.
(d)1ml. Capacity.= 5 Nos.
(iv)Volumetric Flask:
(a)100ml.= 8Nos.
(b) 500ml.= 2 Nos.
( c)1000ml= 1 Nos.
(v)Beaker.
(a)100ml.= 6 Nos.
(b) 250ml.= 6 Nos.
© 500ml.= 5 Nos.
(d)1000ml= 2 Nos.
(vi)Measuring Cylinder graduated with flat bottom.
(a)50ml. = 3 Nos.
(b)100ml. . = 3 Nos.
© 250ml. = 2Nos.
(d)500ml. 2Nos.
(e)1000ml. 1 Nos.
(vii).Wide mouth screw capped autoclavable Reagent Bottle 500ml = 6 Nos.
(viii)Flat bottomed Flask.
(a) 100ml.=6 Nos.
(b) 250ml= 6 Nos.
© 500ml= 6 Nos.
(ix)Test tube without rim.
(a) 18mm dia 200mm long= 100Nos.
(b) 18mm dia 150mm long= 200Nos.
(x) Durhams tubes.= 500 no.
(a) 6mmx 35mm = 100 Nos.
(b) Mild Dilution glass bottom.
(150ml)-50 Nos. screw capped marked for 50ml and 100ml volumes.
© test tube for placing inverted in 150ml bottle to collect gas 12x 75ml= 50Nos.
(d)Loop holder with nichrome wire loop 60mm length 3mm diameter of loop= 3 Nos.
(xi) Aspiratory bottle 5 liter capacity. = 2 Nos.
(xii)Wide mouth laboratory bottle (250ml) with PP screw cap.and PP pouring mouth
autoclavable upto 190O C-250O C to be used for collection of water samples for = 30 no.
bacteriological analysis. = 20 Nos.
(xiii)Culture tubes flat bottom screw capped 30ml.= 100 Nos.
(xiv) BOD bottles 300ml= 20 Nos.
(xv)Washing plastic bottles 500ml.= 6 nos.
(xvi)Funnel glass 4"dia = 3 nos.
6" dia= 3 Nos.
(xvii)Burette stand= 2 Nos.
(xviii)Pipette stand= 2 nos.
(xix) Tube rack for 30ml culture tube= 2 Nos.
(xx) Spatula= 6 nos.
(xxi) Test Tube rack= 5 Nos.
(xxii)Glass rods= 20 Nos.
(xxiii)Glass beads =250gms.
Desiccators= 1 No.
Crucibles= 6 No.
Nessler Cylinders= 20No.
Petri Dishes= 30 No.
North Land Enterprises
Jyoti Trading Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .