Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹34.4 L
EMD Value
₹68,800
Closing Date
30 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Jitender Singh, IDSE
GE (N) Bathinda PIN-151001
SPECIAL REPAIR TO JCO MARRIED ACCN BUILDING NO P-11/01 TO 04 AND P-12/01 TO 04 IN OLD SHIVAJI COLONY UNDER AGE B/R-III AND AGE E/M-V OF GE (NORTH) BATHINDA AT BATHINDA MIL STN
2025_MES_716962_1
8940/NIT-06/25-26/E8
Open Tender
Civil Works
Item Rate
180 days
Bathinda
Class D Category a(i)
8 documents required · 8 mandatory
₹500
Bathinda
₹68,800
Yes
19 Dec 2025
26 Jun 2025
1 Nov 2025
26 Jun 2025
30 Oct 2025
14 Jul 2025
26 Jun 2025 - 7 Jul 2025
Supply, fixing and testing electric water heater (Geyser) Auto restrat and safety measures type electrical operated 230/240 Volts 25 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, plug top, etc. required for proper functionality & including electric/earth connections including testing after installation complete complete all as specified & directed by Engineer-in- Charge.
Material and labour for Aerated Auto Claved concrete (AAC) blocks work according to Indian standard specification IS : 2185 (Part-3)-1985 and latest revision, built in cement sand mortar 1:6 with AAC blocks, straight or curved on plan exc 6.0 meter mean radius as in sunken floors complete all as specified and directed by Engineer-in-Charge.
Dismantling brick tiles / PCC terracing tiles single layer laid on roof and pointed with cement mortar complete all as specified and as directed by Engineer-in-charge.
Supply and fixing single Pole and Neutral enclosure with a two pin and earth plug and socket complete with and including one MCB single pole of capacity 25 Amps,'C' curve,10KA , 240 volts complete all as specified and directed by Engineer-in-Charge. Note: The rate of one MCB single pole of capacity 25 Amps,'C' curve, 10KA, 240 volts is included in this item and nothing shall be paid extra on this account.
Material and labour of Waterproofing treatment to sunken floor using acrylic based multipurpose polymer. The treatment shall be carried out as per manufacturer's specifications. The treatment shall include of the following elements also:- 1. Surface preparation of substrate by removing all traces of contaminates, loose and friable particles, cement la
Each Set of Two
itance oils and grease, water repellent coatings etc 2. Injection grouting using cementitious grout if required. The payment for injection grouting shall be deemed to be included in the unit rates quoted by the contractor. 3. Repair to the substrate, filling of blow holes/voids and surface leveling using appropriate products specified by the manufacturer. 4. All intersections of horizontal and vertical surface should be profiled with a mortar fillet of minimum 25mm x 25mm. 5. The moisture content of the substrate shall be checked before application of first coat at water proof coating at the rate of 200 g/m2 followed brush topping at 450g/m2 per mm. The second coat shall be reinforced with glass fabric between the first and second coat. 6. The treatment shall be protected by application of polymer modified cement mortar of thickness 10mm applied at the rate of 50g per mm. 7. Tech specification: Tensile adhesion strength 0.5N/Sqmm (as bonding slurry).
Material and labour for double charged, stain free Vitrified ceramic tiles, Premium (1st) quality straight edge, coloured tiles having size not less than 595x595 mm and 8 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 20 mm thick screed bed in cement mortar 1:4 and pointed in epoxy grout to match in floors including dismantling of old tiles and removal of rubbish material in low lying empty area (as per direction of AGE/JE) at a adistance upto 500 metre from the site complete all as specified and as directed.
Material and labour for double charged, stain free Vitrified ceramic tiles, Premium (1st) quality straight edge, coloured tiles 595x100 mm and not less than 8 mm thick on vertical surfaces such as skirtings, set & jointed in neat and pointed in epoxy grout to match the floor tiles, over & including 10 mm thick screed in cement mortar (1:4) including dismantling of old tiles and removal of rubbish material in low lying empty area (as per direction of AGE/JE) at a adistance upto 500 metre from the site complete all as specified and as directed.
Litre
Each Job
Material and labour for non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular ) in floors ,area of each tile exc 0.11 sqm but not exc. 0.18 sqm, set and jointed in neat cement slurry and pointed in white or colour cement to match, over and including 15 mm thick screed plaster in cement mortar 1:6 complete all as specified and directed
Material and labour for internal plaster 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces of walls and finishing the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in- charge.
Material and labour for applying three coats of white wash on newly plastered ceiling surfaces including preparation of surfaces, complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparing old plastered or unplastered surface on ceiling and applying one coats of white wash complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparation of new plastered surfaces of walls , with and including applying 1.0mm thick cement based wall care putty , with and including applying two coats of oil bound distemper complete all as specified and as directed by Engineer-in-charge.
Material and labour for complete removal of existing treatment on old plastered and unplastered external surface of walls , with and including applying 1.5mm thick cement based wall care putty , with and including applying two coat of Exterior acrylic emulsion paint over a coat of Exterior acrylic primer complete all as specified and directed by Engineer-in-charge.
Material and labour for complete removal of existing treatment on old plastered and unplastered surface applying two coats of oil bound distempering on old plastered surfaces of walls (internal surfaces), over a coat of 1.0 mm thick cement based wall care putty including preparing surface, complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of newly plastered external surfaces of walls with and including applying two coats of exterior acrylic emulsion paint over a coat of exterior acrylic primer complete all as specified and directed by Engineer-in-charge.
Supplying and laying of CPVC pipes SDR 11 of 16 mm outer dia & plain CPVC SDR 11 fittings in trenches with all the fixing arrangements including taking up or down old GI/PVC/steel tubing and connections complete all as specified and directed
Supply and fixed 110 mm dia/bore PVC (SWR) pipes type 'B' in any length fixed to wall with rubber ring joints including supply & fixing Stack clamps of 50mm x 5mm flat iron & 16mm dia round iron stays, including nuts & bolts & securing ends of stays to wall & roof including dismantling old Cast Iron/PVC pipes including all fittings complete all as specified and directed by Engineer-in Charge.
Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
Material and labour for framed bracket of angles or T with web and flanges cut to shape, drilled and counter shunk for screw including bending and welding angles as neccesary guesset plate, riveting etc for cooler stands, door angle frame, holdfast and brackets etc complete all as specified and as directed by Engineer-in-charge.
Supply & fixing 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including adhesive for pasting and screws for fixing to timber frame complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing LED building security light fitting 25 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete power factor > 0.95, 100 lumen/watt, CCT min 5700K complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters of PVC door ,wooden door shutter, wooden window shutter , Mild steel window and Mild steel ventilators (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each complete all as specified and as directed by Engineer-in- charge.
Material and Labour for Reinforced Cement concrete (Nominal mix), 1:2:4 , Type B-0 (using 12.5 mm graded stone aggregates) as in chajja complete all as specified and as directed by Engineer-in- charge.
Material and labour for mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips directed by Engineer-in-charge.(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges on rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
Returning filling including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in soft/loose soil complete all as specified and as directed by Engineer-in- charge.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregates) as in concrete bed of SGSW drain pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm.
Material and labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade colour and pattern as approved by GE with grey cement and no pigment complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for Internal dia of pipe in 150 mm complete all as specified and as directed by Engineer-in-charge.
Removing excavated material as in all kind of soils not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & directed.
Material and labour for 75 mm thick cement concrete 1:4:8 , type D-2 (using 40 mm
graded stone aggregate) as in sub base of floor. finished even and fair complete all as specified and as directed by Engineer-in-charge.
Material and labour for 25mm thick sand filling under interlocking tiles including watering and consolidation complete all as specified and as directed by the Engineer-in-Charge.Note: Sand shall be approved by GE before incorporation in the work.
Supply & fixing in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed by Engineer-in- charge.
Supply and Fixing switch piano flush type 5/6 Amp, single pole, one way complete all as specified and as directed by Engineer-in- charge.
Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curveshall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed by the Engineer-in-Charge
Material and labour for Welding in repair not exceeding 6mm thickness of metal and not exceeding 2.50 cm in length complete all as specified and as directed by Engineer-in- charge.
Taking down old unsv copper / aluminum point/ submain wiring concealed/ batten (light, fan, socket or power/ submain) complete, including fixture and fittings such as switches, switch-sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/ iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
Material and labour in replacement Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH with and including single core 4 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH for earth wire drawn through the existing PVC concealed conduit including cutting chases for conduits as required for sinking of terminal boxes, making good the same including taking down old unservicable sub main wiring (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and directed by Engineer-in-charge. Note:- Three single core 4 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable shall be measured as one length i.e. 1 RM.
Material and labour in replacement Sub main wiring complete with two single core 6 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH with and including single core 4 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH for earth wire drawn through the existing PVC concealed conduit (Colour code: Phase-Red, Neutral-black and Earth as Green) including taking down old unserviceable sub main wiring complete all as specified and directed by Engineer-in-charge. Note:- (a) Two single core 6 Sqmm and one 4 sqmm single core FRLSH PVC insulated unsheathed with multistranded copper conductor cable shall be measured as one length i.e. 1 RM.
All as per item No 111.00 here- in- before but for one socket outlet 5 pin, 5/6 Amp 230 volts flush type on same board complete all as specified and as directed by Engineer-in- charge.
All as per item No 111.00 here- in- before but for one socket outlet 5 pin, 5/6 Amp 230 volts flush type on independent board complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing in replacement self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 volt 6500K complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed by Engineer-in- charge.
All as per item No 111.00 here- in- before but for one light point controlled by two way switches as complete all as specified and as directed by Engineer-in- charge.
All as per item No 111.00 here -in -before but for one socket outlet 6 pin, 6/16 Amp 2 in 1 with cable 2.5 sqmm multistranded copper conductor FRLSH cable on the independent board including provn of 2.5 Sqmm PVC insulated copper conductor FRLSH cable continues as earth wire connected to earth dolly complete all as specified and as directed by Engineer-in- charge. Note for serial item no.111 to 116 : (i) Switches, sockets & fan regulator shall be measured and paid seperately under respective items of Schedule'A' BoQ. (ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface is included in this item and nothing shall be paid extra on this account. (iii) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clips as directed by Engineer-in- Charge.The rate of this element is included in this item and nothing shall be paid extra on this account.
Supply and fixing Socket outlet 3 pin, 5/6 Amp flush type complete all as specified and as directed by Engineer-in- charge.
Supply and fixing angle/ batten lamp holder on PVC square blocks with PVC insulated body complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement stepped type, electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Bell push switch, flush type, 5 Amp, complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement factory made DB (made out of CRCA sheet not less than 1.2mm thick) SPN, 12 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-54 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including making good disturbed surfaces of walls as necessary including taking down old unserviceable DBs complete all as specified and directed by Engineer-in-charge. Note: MCB & MCCB shall be measured and paid seperately in respective items of Schedule'A' BoQ.
Supply and Fixing ceiling rose surface bakelite 65 mm x 50 mm with three terminal complete all as specified and as directed by Engineer-in- charge.
Supply and fixing switch piano flush type , single pole, one way, 15/16 Amp complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing socket outlet multipurpose 2 in 1, 6 pin, 15/16 Amp 250 volts flush type complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement MCB ‘C’ curve suitable for 230 volts AC supply, 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-charge
Supply and f
Supply and Fixing 35mm thick, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), using 2nd class hard wood (Bonsum/ Hollock) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc , sizes of members of shutters as specified in SSR Part-I, Section 8, Clause 8.24 (a), supplied and fitted to chowkhats complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Wire gauze/ glass shall be measured and paid separately. (ii) The sutters shall be brought at site without primer and same shall be applyied at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply and fixing in replacement of MCCB of capacity 125 Amp, 4 Pole, 415 volt, short circuit breaking capacity not less than 25KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc complete all as specified and directed by Engineer-in-charge.
Material and labour for 15mm thick external cement plaster at any story or any height in cement mortar 1:4 and finishing the surface even & smooth without using extra cement complete all as specified and as directed.
Supply & fixing for steel window box type double shutter (glazed with wire gauge) with side hung shutters including hinges with steel handle and steel peg stay complete with glazing bar dovetailed or welded and including window guard bar, tower bolt,flat iron for fixing wire netting including one shop coat of zink chromate primer paint and making good to distrubed portion to match with existing surfaces complete all as specified.
Supply and fixing Electronic Bell, ding dong type 230 Volt AC supply, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in replacement Ceiling fan of 1200mm sweep complete with aluminium/ steel blades, down rods, and accessories, 230 Volts, single phase, 50 Hz, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current (BLDC) motor connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of suitable size from ceiling rose / connector, including extra GI / MS pipe down rod, as per site requirement , with and including writing serial number of fan as issued by Engineer-in-charge and GE office name with red colour permaent marker complete all as specified and directed by Engineer-in-Charge. Note: Old outdated celing fan shall be depostied in the store yard of AGE E/M (North) Bathinda Mil. Stn
ixing in replacement MCB ‘C’ curve suitable for 230 volts AC supply, 40-50 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement new generation energy saving ,wall mounted LED Tube light batten fittings , extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 20 Watt LED duly fitted on PVC square block 6500K (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz., including electric connection connecting with using flexible coopper wire twin core from ceiling rose to connector including taking down old unserviceable light fittings any type complete all as per manufacturer's instructions and as directed by Engr-in-charge.
Material and Labour for 4 Nos. rawl plug of suitable size (4"-6") with nuts & bolts and grouting in RCC / Brick wall, cutting of exisiting GI pipe line of size 15 mm dia in position for insertion of tee , elbow, niple, union, reducer, branch connection ,etc. with necessary GI fittngs i.e. Tee, elbow, niple, union ,reducer, branch connection etc. and plumbing work and connection jointing and making good as per existing surfaces complete all as specified and directed by Engineer-in-Charge .Note : The rate of 4 Nos. rawl plug of suitable size (4"-6") with nuts & bolts ,Tee, elbow, niple,union, reducer, branch connection etc. of galvanised iron is included in this item and nothing shall be paid extra on this account.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe including taking out old unserviceable pipe complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed for iron pipe of bore 15 mm complete all as specified and directed,all as specified & directed.
Supply & fixing PVC connection of size 15 mm dia with PTMT nuts of length 450 mm long (hot series braded, threaded and cold series) complete all as specified and directed by Engr-in-Charge.
Material and labour for making holes for 300 mm dia exhaust fan of suitable shape & size into or through brick walls at ground / First / Second floor including plastering for making good to the disturbed portion as per original surfaces of any description including painting /distemper matching with the existing colour complete all as specified and directed by Engr-in- Charge. Note : (i) Rates are deems to be including charges of any type of T&P, Insurance of staff deployed at site and nothing shall be paid extra on this account. (ii) Exhaust fan 300mm sweep shall be measured and paid seperately under appropriate item of Schedule 'A' BoQ.
Each Job
Supply & fixing Bib tap 15mm bore , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-Charge.
Material and labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness i.e. 18 cm shall be considered for payment purpose)
Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing GI tubing, light grade 40 mm bore complete with all fittings for cable protection, fixed along poles or laid under floor , under road and hardstanding etc. and making good after laying of cable complete all as specified and as directed by Engr - in- Charge.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.22 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.94 MB
tender06.pdf
Tender Documents • 1.09 MB
BOQ_802710.xls
BOQ • 2.55 MB
NIT06AMD.pdf
PDF • 0.48 MB
NIT06Amdt06.pdf
PDF • 0.47 MB
NIT06Amdt05.pdf
PDF • 0.48 MB
Nit06.pdf
PDF • 0.41 MB
Amendment3.pdf
PDF • 0.50 MB
NIT06.pdf
PDF • 0.08 MB
Amdt01.pdf
PDF • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .