Executive Engineer
Executive Engineer TLMD-III JKPTCL Udhampur
Construction of 132 KV D/C Transmission Line from Power Pooling Station Kishtwar to existing Grid Sub Station of Kishtwar
2025_PDD_285087_1
TLMD-III/udh/12 of 2025-26 dated 22-08-2025
Open Tender
Electrical Works
Turn-key
450 days
Kishtwar
Please refer Tender Document
3 documents required · 3 mandatory
₹10,000
Executive Engineer TLMD-III JKPTCL Udhampur
₹29.7 L
Superintending engineer OM circle I JKPTCL jammu
10 Nov 2025
23 Aug 2025
27 Oct 2025
23 Aug 2025
25 Oct 2025
23 Aug 2025
23 Aug 2025 - 3 Sept 2025
3 Sept 2025
Engineering design,supply of tower accessories ,lattice type tower structures line material & accessories for INSERTION OF 01 NO.TOWER IN 132 KV S/C UDHAMPUR-DHP Transmission LINE.
Danger Plate
Number Plate
Phase plate
Circuit Plate
Anti Climbing Device
Earthing Material
Nuts & Bolts with washers
Special Towers Type 2 normal with 3Mtr. Extension only-1 NO. TOWERS(Including stubs)
Leg extension for SPL 2+3 - 1 nos of height +3 mtr
Dismantling of insulator strings complete with necessary hardwares, conductor accessories, earth wire, including acessories for the line including manual carriage from site to loading site, loading into vehicle and right back to Divisional store Udhampur including unloading, sorting and stacking etc..
Mid span joints for conductor
Vibration Damper
Repair Sleeves
Galvanized strended steel ground wire of size 7/3.15 mm.
Mid span joints for ground wire
Vibration Damper for ground wire
Earthwire tension clamps
120 KN EM strength porcelain disc insulators
Double tension insulator fittings
Engineering, Design & Casting of foundations including all activities like stub setting, supply and installation of earthing device, reinforcement, concreting, excavation, back filling, shuttering, benching, dewatering etc
Special Towers Type 2 normal with 3Mtr. Extension only
Erection of various type of tower including leg extension complete with nuts and Bolts including tack welding and fixing of tower accessories.
Special Towers Type 2 normal with 3Mtr. Extension only-1 NO. TOWERS(Including stubs)
Leg extension for SPL 2+3 - 1 nos of height +3 mtr
Dismantling of earth wire complete with necessary hardwares, including acessories and manual carriage from site to loading site, loading into vehicle and right back to Divisional store Udhampur including unloading, sorting and stacking etc..
ACSR Panther conductor
SOIL TESTING,SURVEY AND CHECK SURVEY INCLUDING SOIL INVESTIGATION ,SOIL PROFILING,CLASSIFICATION,TOWER SPOTTING DATA ETC.
Installation of insulator strings complete with necessary hardwares, laying and stringing of ACSR panther conductor including fixing of conductor accessories and temporary anchoring of towers laying and stringing of earth wire including fixing of earthwire accessories for the S/C line.
Danger Plate
Number Plate
Phase plate
Circuit Plate
Anti Climbing Device
Earthing Material
Nuts & Bolts with washers
Special Towers Type 1 normal with 3Mtr. Extension only-2 NO. TOWERS
Special Towers Type 2 normal with 3Mtr. Extension only-2 NO. TOWERS
Special Towers Type 2 normal with 6Mtr. Extension only-1 NO. TOWER
Raised chimneys for SPL2 +6 - 1 nos of height +3 mtr each
Leg extension
SPL 1+3 - 1nos of height +3 mtr each
SPL 1+3 - 1nos of height +6 mtr each
SPL 2+3 - 2 nos of height +3 mtr each
SPL 2+6- 2 nos of height +6 mtr each
Dismantling of insulator strings complete with necessary hardwares, conductor accessories, earth wire, including acessories for the line including manual carriage from site to loading site, loading into vehicle and right back to Divisional store Udhampur including unloading, sorting and stacking etc..
Mid span joints for conductor
Vibration Damper
Repair Sleeves
24 FIBRE (DWSM) OPGW Fibre Optic Cable
Tension Assembly - Double Tension pass through Asssembly for 24 F OPGW
Tension Assembly - Dead End for 24 F OPGW
Vibration Damper for 24 F OPGW
Down Lead Clamp Assembly for 24 F OPGW
Joint Box for 24 F OPGW
OPGW Fibre Optic Distribution Panel (FODP) Indoor Type 96 F
24 F (DWSM) Approach Fibre Optic Cable including all installation hardware set
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected
Double Tension Fittings For Single Panther shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 120 KN.
Single Tension Fittings For Single Panther shall have minimum failing load of 100% ultimate strength of Bundle cnductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 120 KN.
Tag welding of towers for 5 no. tower
Engineering ,Design, Casting of foundations including all activities like stub setting, supply and installation of earthing device, reinforcement, concreting, excavation, back filling, shuttering, benching, dewatering etc
Special Towers Type 1 normal with 3 mtr. Extension
Special Towers Type 2 normal with 3 mtr. Extension
Special Towers Type 2+normal with 6 mtr. Extension
Raised chimney 3mtr for Special Towers Type 2+6
Erection of various type of tower including leg extension complete with nuts and Bolts including tack welding and fixing of tower accessories.
Special Towers Type 1 +3 - 2 NO. TOWERS
Special Towers Type 2 +3 -2 NO. TOWERS
Special Towers Type 2 +6 -1 NO. TOWERS with raised chimeny 3 mtr height
PART B:- Engineering design,supply of tower accessories ,lattice type tower structures line material & accessories for LAYING OF 132 KV D/C TAP LINE, CONNECTING 132 KV S/C DHP LINE FEEDING POWER TO GSS NHPC.(ACSR PANTHER)
SPL 1+3 -1 NO. OF HEIGHT +3 MTR EACH(LEG EXTENSION)
SPL 1+3 -1 NO. OF HEIGHT +6 MTR EACH(LEG EXTENSION)
Installation of insulator strings complete with necessary hardwares laying and stringing of ACSR panther conductor including fixing of conductor accessories and temporary anchoring of towers laying and stringing of earthwire including fixing of earth wire accessories for the linefor D/C Line
Installation of insulator strings complete with necessary hardwares laying and stringing of ACSR panther conductor including fixing of conductor accessories and temporary anchoring of towers laying and stringing of earthwire including fixing of earth wire accessories for the line for S/C Line
Installation of 24 F DWSM OPGW alongwith associated hardware fittings & vibration dampers
Installation of Joint box above ground including splicing and testing for 24 F
Installation of Fibre Optic Distribution Panel Indoor type: FC Coupling and mounted on ETSI 19'' rack or slimline rack Type 2 96 Fibre
Safety shoes knee height Pair
Earth work in bulk exacavation by manual means including disposal of the same, lead upto 50 mtrs and lift upto 1.5m for maintaining ground clearance as directed by Engineer-in-Charge
Dismantling of tower material including tower accessories, nuts & bolts and washers including manual carriage from site to loading site, loading into vehicle and right back to Divisional store Udhampur including unloading, sorting and stacking etc..
Installation of 24 F Fibre Optic Approach Cable including hardware like ties, clips, cleats, conduits, ducts, supports, fittings etc.
SOIL TESTING,SURVEY AND CHECK SURVEY INCLUDING SOIL INVESTIGATION ,SOIL PROFILING,CLASSIFICATION,TOWER SPOTTING DATA ETC.
SPL 2+3 -1 NO. OF HEIGHT +3 MTR EACH(LEG EXTENSION)
Danger Plate
Number Plate
Phase plate
Circuit Plate
Anti Climbing Device
Earthing Material
Nuts & Bolts with washers
Normal tower (DD+0-Type) With stubs - 1 NO TOWER
Special Towers Type 1 normal With stubs -1 NO. TOWERS
Special Towers Type 2 normal with stubs -4 No. towers
Normal tower (DD+3-Type) With stubs - 1 No. TOWER
Raised chimneys
SPL 1- 1nos of height +3 mtr each
SPL 2- 1nos of height +3 mtr each
Leg extensions
SPL 1- 1nos of height +3 mtr each
SPL2- 6 nos of height +3 mtr each
SPL 1- 1nos of height +6 mtr each
Design, Engineering, Supply,fabrication,galvanization of Multi Circuit tower, for the evacuation of power from Pooling station Kishtwar. The tower must be got vetted from CEA/other approved agencies expertised in Transmission lines dealing with multi circuit towers as well.
MCT With stubs - 2 no. tower
Leg extension of 1 nos of height +3 mtr each
Leg extension of 1 nos of height +6 mtr each
Dismantling of insulator strings complete with necessary hardwares, conductor accessories, earth wire, including acessories for the line including manual carriage from site to loading site, loading into vehicle and right back to Divisional store Udhampur including unloading, sorting and stacking etc..
Mid span joints for conductor
Vibration Damper
Repair Sleeves
24 FIBRE (DWSM) OPGW Fibre Optic Cable
Tension Assembly - Double Tension pass through Asssembly for 24 F OPGW
Tension Assembly - Dead End for 24 F OPGW
Vibration Damper for 24 F OPGW
Down Lead Clamp Assembly for 24 F OPGW
Joint Box for 24 F OPGW
OPGW Fibre Optic Distribution Panel (FODP) Indoor Type 96 F
24 F (DWSM) Approach Fibre Optic Cable including all installation hardware set
120 KN EM strength porcelain disc insulators
Double tension insulator fittings
single tension insulator fittings
Tag Welding of towers for 9 no. Towers
Erection of various type of tower including leg extension complete with Nuts & bolts including tag welding and fixing of tower accessories.
Normal tower (DD+0-Type)
Special Towers Type 1 normal
Special Towers Type 2 normal
MCT Normal With stubs - 2 no. tower
Normal tower (DD+3-Type)
SPL 1- 1nos of height +3 mtr each (Raised Chimney)
SPL 2- 1nos of height +3 mtr each (Raised Chimney)
SPL 1- 1nos of height +3 mtr each (leg extension)
SPL 2-6 nos of height +3 mtr each (leg extension)
SPL 1- 1nos of height +6 mtr each (leg extension)
LEG EXTENSION OF 1 NO. OF HEIGHT +3 MTR EACH for MCT
LEG EXTENSION OF 1 NO. OF HEIGHT +6 MTR EACH for MCT
SPL 2+6 -2 NO. OF HEIGHT +6 MTR EACH(LEG EXTENSION)
Installation of 24 F DWSM OPGW alongwith associated hardware fittings & vibration dampers
Installation of Joint box above ground including splicing and testing for 24 F
Installation of Fibre Optic Distribution Panel Indoor type: FC Coupling and mounted on ETSI 19'' rack or slimline rack Type 2 96 Fibre
Installation of 24 F Fibre Optic Approach Cable including hardware like ties, clips, cleats, conduits, ducts, supports, fittings etc.
Survey & Check survey including Soil investigation , Soil classification, Profiling tower spotting data etc.
Casting of foundation including all activities like stub setting, supply and installation of earthing device, reinforecement, concreting, excavation, Back filling, shuttering ,benching, dewatering etc.
Normal tower (D-Type)
Special Towers Type 1
Special Towers Type 2 normal
Raised chimneys of height +3mtr of special 1
Raised chimneys of height +3mtr of special 2
Preparing of foundation design, getting it vetted by the CEA/other approved agencies expertised in Transmission lines dealing with multi circuit towers as well and Casting of foundation including all activities like stub setting, supply and installation of earthing device, reinforecement, concreting, excavation, Back filling, shuttering ,benching, dewatering etc. in all respect.
snow shoes(Duck back)
Earth work in bulk exacavation by manual means including disposal of the same, lead upto 50 mtrs and lift upto 1.5m for maintaining ground clearance as directed by Engineer-in-Charge
Construction /expansion of exisiting control building /RCC Protection wall and Path at grid sub-station kishatwar
Earth work in bulk excavation by manual means over areas (exceeding 30 cm indepth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earthlead upto 50 meters and lift upto 1.5 m.
All kinds of soil
Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with:1:4:8
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with4.4.5 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay Modular bricks of class designation 7.5. in foundation and plinth including curing complete in :Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
Brick work with common burnt clay Modular bricks of class designation 7.5. in foundation and plinth including curing complete in : Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete above plinth level5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for:Columns, pillars, piers, abutments, posts and struts
Providing laminated veneer lumber conforming to IS. 14616 and TAD-15: 2001 (part B) in factory made frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length including hold fast lugs or with dash fasteners
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butthinges bright finished of required size with necessary screws).35mm Second class deodar wood
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 35mm Second class deodar wood
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Riveted and bolted
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. .60 mm thick with zinc coating not less than 350 gram/m2
Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde syntheticresin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminum primer on both sides & edges, including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodized aluminum (with 15 micron anodic coating) Tsections 35 x15x1.5 mm size main runners, cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer including aluminum frame work
12mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 4 ( 1 cement : 4 fine sand)
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 4.4.6 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.88.2 2 mm thick
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 13.93.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ liter
Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and includingbase coat of exterior primer applied @ 2.20kg/10s
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work
Painting on G.S sheets with synthetic enamel pa
int of approved band and manufacture of required colour to give an even shade on New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution.
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade on new work Two or more coats
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mmnominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Providing of protection to the tower footings in 1:6 R S masonary work including lean pad/PCC,DPC,Couping,back filling stone flush pointing in cement mortar 1:4 filter stone As required and also getting drawings approved from concerned authority
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead : in cement mortar
RCC Protection Work for 15 No. Of Towers
Earth work in excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m for All kinds of soil.
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6graded stone aggregate 40 mm nominal size) including supply and all type of carriages.
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 5.2.1 DELETED 5.2.2 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)) including providing and placing PVC pipes 100 mm dia for weep holes. including supply and all type of carriages
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. including supply and all type of carriages
Centring and shuttering including strutting, propping etc. and removal of form for 5.9.2 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc including supply and all type of carriages.
Filling good earth in trenches, plinth, sides of foundations making of required platform at the base of tower etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. including supply and all type of carriages.
RCC PROTECTION WALL/B/WALL ( BALANCE PORTION ) AT 132/33 KV GRID SUB STATION KISHATWAR in ratio 1:2:4 after approval of drawings from concerned authority.(EXCLUDING cost of steel)
PART-C :-Engineering Design, supply of Tower Accessories, lattice type tower structures line material & accessories for laying of 132kv D/C RKKTL TAP LINE, CONNECTING 132KV D/C RAMBAN KHELLANI KISHTWAR TX LINE FEEDING POWER TO GSS KISHTWAR(ACSR PANTHER)
Installation of insulator strings complete with necessary hardwares laying and stringing of ACSR panther conductor including fixing of conductor accessories and temporary anchoring of towers laying and stringing of earthwire including fixing of earth wire accessories for the D/C line.(CKT KM)
Earth work for construction of drain around control room
PCC for drain around control room M10
PCC for drain around control room M15
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering including supply and all type of carriages.
Material to be supplied to Divisional store
Single Tesnion fitting for single panther shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type tension clamps having slipping strength 95% of ultimate strength of conductors. The ball and socket designation must be 20mm. minimum ultimate strength ( Tensile strength) shall be 120KN
Single suspession fitting for single panther shall have minimum failing load of 50% ultimate strength of Bundle conductors with forged steel hanger free centre type without bolt only having slipping strength 15% of ultimate strength of conductors. The ball and socket designation must be 20mm. minimum ultimate strength ( Tensile strength) shall be 70KN/ 120KN
Double Tesnion fitting for single panther shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type tension clamps having slipping strength 95% of ultimate strength of conductors. The ball and socket designation must be 20mm. minimum ultimate strength ( Tensile strength) shall be 120KN
PG Clamps 0.4 made of Alminium Alloy and shall comply in all respect with IS: 5561-1970 (latest edition) for panther
T Clamps 0.4/0.4, made of alminium alloy and shall comply in all respects with IS: 5561-1970 (latest edition) for panther
Mid Span compression joint (panther)
G.I Nuts & Bolts of sorts ( 16mm dia) ( hot dipped )
Spring washers ( G.I hot dipped)
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
12 volt rechargable search light with inbuilt charger complete with dimmer & flasher of reputed make such as VKS etc
Insulated cutting pliers 12 inches size of reputed make
Insulated cutting pliers 8 inches size of reputed make
T & P Items
Hammer 8 Lbs.
Screw driver 18 inches size of reputed make
construction of under ground water tank in cement concrete 1:2:4 including excavation ,backfilling,shuttering and disposal of surplus soil etc.
Screw driver 12 inches size of reputed make
Die Set Hex 43 Aluminium for panther/ zebra Set (as per sample provided by the deptt.)
Die Set Hex 25.5 Steel for G wire Set as per sample(as per sample provided by the deptt.)
Automatic Clamp (Self Griping) 18-24 mm 132KV for casablance to Drake
Chain Block Lifting 5 Ton X 6 Mtr
Four Sheave Pulley 8 Ton
Single Sheave Pulley Open I Type 5 Ton
Single Sheave Pulley Close I Type 5 Ton
Single Sheave Pulley Open I Type 8 Ton
Steel Wire Rope 12mm Dia.
Chainsaw 22”, 2.4 hp of reputed make
Hand operated Hydraulic Compression 100 ton Press Machine Set with die set for Transmission Line ( as per sample provided by the deptt.)
D Shackle 6.5 Mt
D Shackle 8.5 Mt
bundle
PP Rope 20mm (100 m) Bundle
Bull dog Clamp 16mm
Dumping/filling of stone in Horizontal on level behind the retaining wall as filter stone including supply of stone, including supply of stone and all type of carriages.
Iron cutter 14”, 2300 W of reputed make
Safety belt, minimum 2 m rope length along with scaffold hook - Class-A material suitable for EHV TransmissionLine maintenance staff (PN56 & 351)(Double lanyard with padded straps and supports) hook - Class-A material suitable for EHV Transmission
Safety Gloves 33 kV Pair
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.46 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.64 MB
Tendernotice_2.pdf
PDF • 9.09 MB
BOQ_883154.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .