Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.7 L+₹89,822 (2.58%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹37.1 L+₹2.3 L (6.57%)Rejected-AOC | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹37.4 L+₹2.7 L (7.64%)Rejected-AOC B 68 MOTIKUNJ MATHURA 281001 UP | MATHURA | UTTAR PRADESH | 281001 | L4 | Rejected-AOC Other than L1 | |
| 5 | L5₹38.1 L+₹3.3 L (9.60%)Rejected-AOC | L5 | Rejected-AOC Other than L1 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
14 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri TKM Rambhal, EE
GE (West) Mathura
SPECIAL REPAIR TO BLDG NO P-148 (OR LIVING LINE) UNDER GE (W) MATHURA
2021_MES_468298_1
8300/1013/E8
Open Tender
Civil Works
Item Rate
180 days
Mathura Cantt
As per tender documents
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹82,000
Yes
30 Sept 2021
17 Aug 2021
15 Sept 2021
17 Aug 2021
14 Sept 2021
1 Sept 2021
60 days
Amount
Taking down cement plaster on brick or stone walls ,ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick on fair faces of brick work or concrete surfaces of ceiling in cement mortar (1:3) complete all as specified and directed.
M&L for rendering dubbing coat over irregular surfaces of chajjas roof projections /ceiling /facia etc average 15mm thick in CM (1:4) over cement slurry coat @ 3Kg/Sqm making the surface even followed by 5mm thick rendering in CM (1:3) furnished even & smooth including making of drip course as required complete including roughening surface of old concrete by picking sweeping clean and washing with water complete all as specified and directed.
Demolition of reinforced cement concrete not exc. 15cm thick below or above ground level complete all as specified and directed.
M&L for preparation of new surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coat of apex paint on walls complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coat of distemper oil emulsion over a coat of alkali resistant primer on wall etc complete all as specified and directed.
M&L for preparartion of new plastered surfaces of walls and applying three coats of white wash on wall complete all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for complete removal of existing treatment on walls and applying two coat of white wash including preparation of surface complete all as specified and directed..
M&L for preparation of old distempered surfaces of walls and applying one coat of disemper oil emulsion white or tinted complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces and applying one coat of cement base paint on walls complete all as specified and directed.
Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down chowkhats with shutter (without taking off shutters from the frame) area exc. 1.50 Sqm but n.exc 4.00 sqm each complete all as specified and directed.
Taking down shutter only of any description exc 1 sqm but n. exc 2 sqm each complete all as specified and directed.
Taking down shutter only of any description exc 2 sqm each complete all as specified and directed.
S&F 125x60mm pressed steel frames for doors with one or more rebates including necessary lugs, hinges lock, strike plate etc complete all as specified and as directed.
S&F 105x60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges lock, strike plate etc complete all as specified and as directed.
S&F Factory Made Solid PVC Moulded Door Shutters 35 mm thick (stile:), with particle board core and 2,4 or 6 raised panel design with 5mm thick Moulded colour PVC Sheet on the front Face & 5mm Plain colour PVC sheet on back face, fixing in frame at site complete specification & drawing as per SSR.
S&F 35mm thick factory made glazed and skeleton shutters of 2nd class HW with partially panel shutter open rebated and prepared to receive glass / gauze etc edges or framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc as specified in SSR pt-1 section 8.24 (a) complete all as specified and directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed.
M&L for cement concrete type C-1, (1:3:6) using 20mm graded aggregate as in bed block or filling of chowkhats including form work complete all as specified and directed.
S&F mild steel framed work as grills, gratings etc with end of bars shouldred and / or rivited or forged into spikes, framed guard bar barred iron door ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290, Gde-E-165, complete all as specified and directed.
S&F 3 mm thick sheet glass,ordinary quality and glazing with oil putty in squares not exceeding 0.50 sq.m. in each pane complete all as specified and directed.
S&F for stainles steel wire cloth 0.36 mm nominal dia of wire and avg width of aperture 1.14 mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty/wooden beading in panes n.exc. 0.5 sqm each pane including hacking out old glass panes, complete all as specified and directed.
S&F in repair stainles steel wire cloth 0.36 mm nominal dia of wire and avg width of aperture 1.14 mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F Factory made PVC single door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as per specification and drawing of SSR Part-I and the door frame to be fixed to the wall using MS screw 75mm long with PVC fastener as per manufacturer's, instruction complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with particle board core and 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plain colour PVC sheet on back face, fixing in frame at site complete specification & drawing as per SSR complete all as specified and as directed..
S&Fstainless steel butt hinges 100mm complete all as specified and directed.
S&F 150mm powder coated Anodised aluminium anodised barrel tower bolt of extrude section and fixed complete all as specified and directed.
S&F 250 mm aluminium alloy, anodised sliding door bolts with hasp, staple and fixing clips of sheet, cast or extructed section and fixing bollts and sliding bolts of extruded section or cast aluminium ally and fixed complete all as specified and directed.
S&F powder coated Anodised aluminium 125mm handles, cast type complete all as specified and directed.
S&F 300mm mild steel (Helical door spring) ordinary rat tail rod pattrern spring including roller and roller plate complete with necessary welding work complete all as specified and directed.
S&F for aluminum anodized 25mm dia as in curtain rod fixed to brackets complete all as specified and as directed.
M&L for Preparing new wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying a coat of pink primer and two coats of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of new steel surface of any description not otherwise described exc 10cm width or girth and applying two coats of synthetic enamels paints over a coat of red oxide primer complete all as specified & directed.
M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of old steel surfaces of any description or girth over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and emoving rubbish off premises complete all as specified and directed.
M&L Non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match with and including 15mm thick screed bed in cement mortar (1:4) for laying floor finishes complete all as specified and as directed.
M&L for glazed ceramic tiles 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to the match tiles on vertical surface over 10mm thick plastering in CM (1:3) complete all as specified and as directed
M&L for 16-18mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including 20mm screed bedding in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with pigment to match the shade of the slab including rubbing and polishing including screed bed and bedding layer of mortar 20 mm thick in CM (1:4) for laying floor finishes size complete all as specified and directed.
M&L for machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over and including cement plaster 15 mm thick in CM (1:3) laid and jointed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
M&L for grinding, cutting and polishing to old surface of kota stone as in floor, skirting, dado, steps in three grinding with marble stone and cleaning of floor and disposal of rubbish outside complete all as specified and directed.
M&L for providing precast cement concrete (1:2:4) type B-2 using 20 mm graded stone aggregate as in landings, cover slabs (for man holes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces.complete all as specified and directed.
Demolition of brick work or stone/boulders masonary, built in cement mortor including all quoins, arches pillars, etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for brick work with fly ash old size brick straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) (1:1½:3) type A1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors roofs landings canopies deck slab and in snelves and the like complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished of flat surface complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Taking up or down steel tubing and connection or removal to store 15mm bore pipe. complete all as specified and as directed.
Taking up or down steel tubing and connection or removal to store 20mm bore pipe. complete all as specified and as directed.
Taking up or down steel tubing and connection or removal to store 25mm bore pipe. complete all as specified and as directed.
M&L 15mm bore GI tubing medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and directed.
M&L 20mm bore GI tubing medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and directed.
M&L for cutting chases, pining in making good to facing where required and pointed in CM (1:3) to ends or edges of landing , steps cills, sun shade, shelves etc and cutting chases for concealed conduit wiring etc and making good , match with existing surfaces by applying white/colour wash cutting not exc 10cm girth complete all as specified and directed.
S&F in repair 15mm bore chromium plated bib tap cast copper alloy fancy type (min weight 400 gm) screwed down, screwed for iron pipe or for brass ferrule and fix complete all as specified and directed.
S&F in repair CP stop cock fancy type chromium plated 15 mm bore screwed down, high pressure screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair chromium plated stop cock cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipe with long shank and cup (concealed type) 15mm bore complete all as specified and directed.
S&F in repair for swiveling shower 15 mm with shower arm 195 mm long of CP of any colour and fixed complete all as specified and directed.
S&F PVC connection 15 mm size of lenght PTMT nuts 450mm long complete all as specified and directed.
S&F Pillar taps cast copper alloy, fancy type with capstan head, CP, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nut, screwed for iron pipe 15 mm bore, supplied and fixed in repairs, complete all as specified and directed.
S&F in repairs vitreous china urinal, half stall type, white incl 15mm bore push tap any colour of PTMT screwed for iron pipe and fixed complete including providing and fixing plugs with and including 60mm long brass screws, pointed around urinal back in cement; fixin discharge pipe, flush pipe, grating and union for discharge complete all as specified and directed.
S&F in repair Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including setting the trap and pan in concrete and including 10 ltr capacity PVC valveless syphonic action type low level flushing cistern and 32mm dia PVC flush pipe complete including jointing to socket of flushing rim, complete all as specified and directed.
S&F in repair vitreous china wash down, water closet pan (pedestal pattern), white including fixing bolts and connection to flush pipe and drain out going pipe and closet seat cover black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, CP jet including PVC connection including 10 ltr capacity PVC valveless symphonic action low level flushing cistern complete all as specified and directed.
S&F in repair Vitreous china wash basin white flat back size 550 x 400mm size, including cutting for and pinning in ends of brackets or erecting stand but inclusive of fixing of supply and waste fitting & waste pipe 32mm bore complete fixed complete all as specified and directed.
S&F towel rail chromium plated 20mm dia ‘D’ type, 600mm long, complete all as specified and directed.
S&F low density poly ethylene waste pipes (LDPE) of 32mm bore not less than 750mm long complete suitable for wash basins, complete all as specified and directed.
S&F in repair Stainless steel gratings 100mm bore size fixed with white cement, complete all as specified and directed.
Dismantling of cast iron pipes any size of bore as in soil waste or vent pipe including removal of cement joints fixed to wall or laid in floor complete all as specified and directed.
S&F 110mm CI pipes soil, waste and vent pipe (spun pipes) in any length with or without ears, with cement joints fixed to wall including applying a coat of black japaned paint on outer surface of pipes complete all as specified and directed.
S&F 110mm bore pipe cast iron soil and waste and vent pipes (spun pipes) in any length with or without ears with cement joints laid in trenches or in floors including necessery earth work complete all as specified and directed.
S&F 75mm bore pipe cast iron soil and waste and vent pipes (spun pipes) in any length with or without ears with cement joints laid in trenches or in floors including necessery earth work complete all as specified and directed.
S&F 75mm CI pipes soil, waste and vent pipe (spun pipes) in any length with or without ears, with cement joints fixed to wall including applying a coat of black japaned paint on outer surface of pipes complete all as specified and directed.
S&F 100mm CI Bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and as directed.
S&F 75mm CI Bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and as directed.
S&F 100mm CI Branch pieces, single T (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified & directed.
S&F 100mm CI Branch pieces, single T (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified & directed.
S&F 75mm CI Branch pieces, single T (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified & directed.
S&F 75mm CI Branch pieces, single T (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified & directed.
S&F cast iron cowl 75mm dia as required complete all as specified & directed.
S&F 75mm cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank triple layer white colour (cylindrical vertical with closed top) hoisted and fixed in position to make up of 1000 Ltr capacity including taking down old unserviceable tank complete all as specified and directed.
S&F stack clamps mode out of 50x5mm flat iron including bolts and nuts and securing ends of stays to wall or roof, for 110mm bore pipes, complete all as specified and directed.
S&F stack clamps mode out of 50x5mm flat iron including bolts and nuts and securing ends of stays to wall or roof, for 75mm bore pipes, complete all as specified and directed.
S&F float valve of 25 mm dia ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F 32mm Waste fittings, brass, chromium plated for basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
S&F GI tubes light grade, laid on sunken floor as on spout pipe 50mm bore complete all as specified and directed.
S&F SGSW gully trap 150 x 150mm square or round mouthed, type P incl jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified & directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished and reforming benching as required for 150 mm bore pipe complete all as specified and directed.
M&L precast cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in landings, cover slabs (for manholes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set in cement mortar (1:4) complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C1 using 20mm graded stone agg as in plinth protection etc, finished even & fair without using extra cement including mastic filling to joints complete all as specified and directed.
M&L for Keyed pointing in CM (1:4) to brick-tile fecing, with tiles laid flat in stretcher course complete all as specified and as directed.
M&L for 25 mm nominal bore Mild steel galvanised water tubing, medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
M&L for 50mm thick PCC (1:2:4) type B-1using 20mm graded stone aggregate ) as in floor finishes surface even and fair without using extra cement complete all as specified and directed.
Wornout existing treatment from sunken portion of WC /Bath/Kitchen/Passage including taking down floor tiles, plaster, lime/cement concrete, WC trap complete empty of existing sunk complete all as specified and directed. Note :Taking down of plumbing & sanitary fixing & fixture shall be measured under relevant items
M&L for cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate in coping, coving, roof padding, padding in sunken slab as directed mixed with liquid water proofing compound wherever if required complete all as specified and directed. Note:- Liquid WPC shall be measured and paid saperately.
M&L for PCC (1:5:10) type E-2 using 40mm graded stone aggregate as in Sub base of ground floors or in sunken portion complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces finished fair and even in CM (1:3) mixed with liquid water proofing compound complete all as specified and directed.
Supply only Liquid water proofing compound of approved complete all as specified and directed.
Removing / taking down of old water proofing treatment from roof/concrete surface and removed the debris to distance exc 250m and n.exc 500m from the site and cleaning of the roof surface with wire bursh to make it free from dust , dirt etc complete all as specified and directed.
M&L for applying protective coating with bituminous based aluminium paint @ 0.2 Kg/sqm in two coats complete all as specified and directed.
M&L for water proofing treatment with APP modified bituminous membrane 3mm thick consisting of the following for RCC roof :- (a) Cleaning palstered roof surfaces and applying a coat of oxidised bitumen based solvented primer a@ 0.3Kg /Sqm of approved make on top of dry surface of RCC roof complete all as specified and directed. (b) M&L for APP modified polymeric water proofing membrance 3mm thick weight not less than 3.0 Kg/Sqm with non woven polyster core of approved make applied by heating one surface of membrane with LPG torch with lap of 100mm and the overlap shall be sealed by flame complete all as specified and directed.
S&F coloured Non Skid ceramic tiles 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.18 sqm n.exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including and over 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for 25mm thick sand filling under floors or in foundation complete all as specified and directed.
M&L for Machine pressed precast conctete interlocking paver block with grey cement & pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
Removing excavated soil/material to a distance n.exc 50m and depositing where directed at a level not exc 1.5m above starting point complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.50 mtr depth for foundation etc or for shafts, wells, cesspits, main holes, pier holes etc complete in soft/loose soil complete all as specified and directed.
Taking down surface / concealed copper / aluminium point wiring (light,bell,fan,socket or power) complete, including fixtures and fittings such as switches,ceiling roses,lamp holders,pendants,sockets, regulators,tubelight fittings etc and making good disturbed surfaces with plaster on walls, floors etc complete all as specified and directed.
M&L for point wiring with PVC insulated, unsheathed 1.5 sqmm FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC concealed conduit medium grade not less than 20 mm dia ISI marked ivory colour with and including all conduit fittings and fixing accessories including not less than 1.20mm thick sunken anodised pressed steel terminal boxes/modular boxes suitable for fixing of modular face plates, 3.0 mm thick hylam sheet cover/modular plate cover for mounting switches, sockets, fan regulators etc incuding 1.5 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete for the following:- (a) one light point controlled by one switch
All as per item No 118.00 (here-in-before) but for one fan/exhaust point controlled by one switch.
All as per item No 118.00 (here-in-before) but for one light point controlled by two way switch.
All as per item No 118.00 (here-in-before) but for one 3 pin socket outlet 5amps point controlled by one switch on the same board with other switches.
All as per item No 118.00 (here-in-before) but for one 3 pin socket outlet 5amps point controlled by one switch on independent board.
M&L for point wiring with 4.0 sqmm PVC insulated, unsheathed FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all and including conduit fittings and fixing accessories 1.20mm thick sunken anodised pressed steel terminal boxes with 3.0 mm thick hylam sheet cover for mounting switches, socket etc including 4.0 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete for one socket 16 Amp socket outlet controlled by one switch on independent board.
S&F switch piano flush button single pole, one way 5 Amp 240 Volt complete all as specified and directed.
S&F switch piano flush button single pole, two way 5 Amp 240 Volt complete all as specified and directed.
S&F socket outlet 5 pin 5/6 Amps flush type complete all as specified and directed.
S&F switch piano flush button single pole, one way 16 Amp 240 Volt complete all as specified and directed.
S&F socket out let ,6 pin 5 and 16 Amps multi purpose 2 in 01 flush type 230 volt complete all as specified and directed.
S&F fan regulator electronic, 5 step type hum free suitable control speed of fan from 0 to 100 % and connecting electrically all as required complete all as specified and directed.
S&F Angle/ battan holder polycorbonate type body suitable for batten fitting complete all as specified and directed.
S&F ceiling rose of 65x50mm PVC/polycarbonate three terminal surface bakelite complete all as specifiend and directed.
S&F in replacement sheet metal enclosure Single pole & neutral with 2 pin and earth plug capacity and socket 20A 240 Volt complete with one single pole MCB of 20 A complete all as specified and directed.
S&F in repair decorative Ultra Slim Linear LED lighting fixture extruded aluminium housing for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, environmental friendly, energy efficient for 20 watts LED 6000K with batten including conecting up with suitable flexible wire from ceiling rose/ connector complete all as specified and directed.
S&F 10W integrated LED bulk head luminaire environment friendly, ultra modern, energy saving, surface mounted decorative oval bulk head with LED light, complete all as specified and directed.
S&F in repair LED bulb base B22 of capacity 10 watts not less than 700 lumens output at 6500K colour temp, complete all as specified and directed.
S&F in replacement factory made sheet metal enclosers distributed board double door three phase 415 volts 6 way for MCCB 250 Amp, 4P as incoming and MCB (TP/SP) as outgoing comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed. Note : (i) The DB shall be VTPN of specified makes listed in Appendix 'B'. (ii) The DB Shall be flush fixed and making good the distrubed surface matching with existing specification shall be part of job at no extra cost. (iii) Connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin / bottle type thimble-properly crimped. (iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size.
S&F in repair building security light of 30 Watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver including housing suitable brackets, nuts & bolts and GI pipe complete all as specified and directed. .
M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
S&F in replacement sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with minimum capacity 200 Amp bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board single pole & neutral 240 volts 4 way with IP-43 IK-09 protection double door complete with minimum capacity 200 Amp bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F MCB SPN 240 volts, 40-63 Amps, 10KA, 'C' Curve complete all as specified and directed.
S&F MCB SPN 240 volts, 32 Amps, 10KA, 'C' Curve complete all as specified and directed.
S&F MCB SP 240 volts, 40-63 Amps 10KA, 'C' Curve complete all as specified and directed.
S&F MCB SP 240 volts, 6-32 Amps 10KA, 'B' Curve complete all as specified and directed.
S&F Exhaust fan 300mm sweep, metallic body heavy duty, four blade, double ball bearing, 1400 RPM, minimum air delivery dishcarge 1710 CMH suitable for SP 230/250V, 50 Hz AC Supply with protective bird guard with louver shutters including grouting of frame in wall and connecting with and including 3 run 0.5 Sqmm single core, PVC insulated but sheathed FRLSH multistranded copper conductors cable from ceiling rose to exhaust fan complete all as specified and directed.
S&F ceiling fans 1200mm sweep white in colour of Aluminium blades (three numbers) and body, double ball bearing, down rod, fan motor, pair of canopy shackle, assembly kit, electronic regulator with minimum air delivery 210 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) etc suitable for SP 230 to 250 volts, 50 Hz, AC supply complete all as specified and directed.
M&L for making of hole in brick wall including removal of dismantled materials, making good disturbed surface, platering, making holes fixing bolts suitable for fixing 12" exhaust fan frame, complete all as specified and directed.
M&L for in replacement Earthing complete with galvanised steel earth plate electrode 600x600x 6mm thick , directly in the ground vertically to depth not less than 2.25 mtr below the ground level with top edge of earth plate surrounded by 15cm thick layer of chorcoal dust and common salt. connected to galvanised iron earthing wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel , GI pipe light grade 40mm bore for protection of earth lead and GI watering pipe 20mm bore light grade with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C1, 80mm thick pre cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric 50mm mesh size and 3.0 mm dia of wire each way, earth plate surrounded by alternate layres of packed chorcoal salt packed which shall be not less than 15 cm in all sides of earth plate all as shown in electricale Plate No-3 MES Sch Part-I, complete all as specified and directed.
M&L for sand cushioning and covering clean and dry sand to underground electric cable with 8 cm before laying and 10 cm over the cable including ramming complete all as specified and directed.
M&L for bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and directed.
S&F GI tubing light grade 50 mm dia along the wall/ in trenches/in duct/ in culvert/ road crossing and including provisioning of suitable mild steel flat iron clams and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles all as specified and directed.
Taking down carefully existing ceilling fan any type, sweep and removing fan blade including cleaning all dust particle and filling cavities with filler material, oiling ,greasing including painting fan with blade complete one coat of synthetic enamel white paint by spraying and assemble the same along with all fixing connecting accessories and fixing the same position along with all new electrical wire connection complete all as specified and directed.
Supply & laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with ''XLPE'' insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 35 Sqmm x 3.5 core size including taking out old unserviceable cable complete all as specified and directed. Note: Earth work and other connected work shall be measured & paid sperately.
SHYAMA CONSTRUCTION
DIKSHA CONSTRUCTION CO
M/s Hoti Lal Contractor
Shakashi Construction Co.
M/S JAGVIR SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .