| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹44.3 L Quoted ₹46.5 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹49.7 L+₹3.2 L (6.98%)Rejected-Finance | ₹49.7 L+₹3.2 L (6.98%) | L2 | Rejected-Finance HIGHER |
| 3 | L3₹51.5 L+₹5.0 L (10.7%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹51.5 L+₹5.0 L (10.7%) | L3 | Rejected-Finance HIGHER |
| 4 | Rejected-Technical | - | - | Rejected-Technical NO IN WLR QE SEP 2022 CEWC |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
9 Jan 2023, 6:00 pmClosed
GE Amritsar
GE Amritsar Pin 143001
REPAIR/REPLACEMENT OF LT OH LINE/UG CABLE AND CONNECTED ITEMS OF ELECTRIC SUPPLY UNDER GE AMRITSAR
2022_MES_568057_1
GE/ASR-72/2022-23
Open Tender
Civil Works
Works
150 days
GE Amritsar
Class D category b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹96,000
29 Oct 2024
8 Dec 2022
10 Jan 2023
8 Dec 2022
9 Jan 2023
26 Dec 2022
Amount
Material and Labour for prunning of tree branches touching to electric over head lines and wild growth around LT / HT over head lines and around pole and stay complete to make clear span of 2 Mtr from tree branches both side of the OH line with JCB/Cutter and all tools, plants etc ; Complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take upmost care to avoid damage to existing lines/structures if any breakdown of line caused during punning shall be made good without any extra cost by the contractor. (iii) Prunning of tree to be done twice a year (before & after rainy season) (iv) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures the contractor will be solely responsible for it and nothing extra on this account will be paid to the contractor
Excavating in trenches not exceeding 1.5metre wide and not exceeding 1.5metre in depth ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, sewage lines , laying of cable, poles foundation etc. not exceeding 10 sq m on plan and not exceeding 1.5m in depth and getting out in soft/ loose soil ; Complete all as specified and as directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5metre wide and exceeding 1.5metre but not exceeding 3 metres in depth ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, sewage lines , laying of cable, poles foundation etc. not exceeding 10 sq m on plan and not exceeding 1.5m in depth and getting out in soft/ loose soil ; Complete all as specified and as directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5metre wide and not exceeding 1.5metre in depth ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, sewage lines , laying of cable, poles foundation etc. not exceeding 10 sq m on plan and not exceeding 1.5m in depth and getting out in Hard/Dence soil ; Complete all as specified and as directed by Engineer-in-charge.
Returning,filling in,spreading,levelling,watering and well ramming in layers not exc 25cm thick each as in any type of soil, ; Complete all as specified and as directed by Engineer-in-charge.
Removing excavated material not exceeding 100 metres and depositing where directed at level not exc 1.5mt above the starting point ; Complete all as specified and as directed by Engineer-in-charge.
Supply & laying in repairs DWC HDPE pipe 75 mm bore ISI marked suitable for drawing LT Cables etc complete with all accessores ; Complete all as specified and as directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 10 Sqmm 04 core (heavy duty) 1100 Volts grade with stranded Aluminim conductor , in trenches or drawn through pipe or fixed on wall / poles , , including disconnecting and taking down/out the old unserviceable cable ; complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 16 Sqmm 04 core (heavy duty) 1100 Volts grade with stranded Aluminim conductor , in trenches or drawn through pipe or fixed on wall / poles , , including disconnecting and taking down/out the old unserviceable cable ; complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 25 Sqmm 04 core (heavy duty) 1100 Volts grade with stranded Aluminim conductor , in trenches or drawn through pipe or fixed on wall / poles , , including disconnecting and taking down/out the old unserviceable cable ; complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 35 Sqmm 3½ core (heavy duty) 1100 Volts grade with stranded Aluminim conductor , in trenches or drawn through pipe or fixed on wall / poles , , including disconnecting and taking down/out the old unserviceable cable ; complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 50 Sqmm 3½ core (heavy duty) 1100 Volts grade with stranded Aluminim conductor , in trenches or drawn through pipe or fixed on wall / poles , , including disconnecting and taking down/out the old unserviceable cable ; complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 70 Sqmm 3½ core (heavy duty) 1100 Volts grade with stranded Aluminim conductor , in trenches or drawn through pipe or fixed on wall / poles , , including disconnecting and taking down/out the old unserviceable cable ; complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 95 Sqmm 3½ core (heavy duty) 1100 Volts grade with stranded Aluminim conductor , in trenches or drawn through pipe or fixed on wall / poles , , including disconnecting and taking down/out the old unserviceable cable ; complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 120 Sqmm 3½ core (heavy duty) 1100 Volts grade with stranded Aluminim conductor , in trenches or drawn through pipe or fixed on wall / poles , , including disconnecting and taking down/out the old unserviceable cable ; complete all as specified by Engineer-in-Charge.
Material and Labour for making good the damaged Road surfaces by using additional stone metal, PCC etc and making good disturbed surfaces ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for repairs of LT Panel board of any size with replacing the unserviceable MCCB,MCB,switch fuse unit , change over ,Busbar,etc jointing cable with proper lugs ,nut , bolt and washers, cleaning the panel by using of CRC Soluation and repairing the panel door by using hinges and repairing the lock system, welding etc painting the LT Panel with one coat of primer & two coat of synthetic enamel paint after scraping the extg paint surfaces ; Complete all as specified and as directed by Engineer-in-Charge. Note:(i) MCCB,MCB,Switch fuse unit and change over switch will be measured and paid separately under relevant items . (ii)Rate of new lugs,CRC Solution,nut,bolts, and added additional 1.5 m or part thereof in depth beyond the first 1.5 mtr. and washers etc is deemed to be included in quoted rates.
Supply and fixing in repairs of MCB 4 Pole 63 Amps with breaking capacity 10 KA and connecting ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs of MCB 4 Pole 40 Amps with breaking capacity 10 KA and connecting ; Complete all as specified and as directed by Engineer-in-Charge.
Supply only MCCB, 4 Pole, 400 Amps , with breaking capacity 36 KA ,with thermal magnetic setting adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II with suitable spraeders ; Complete all as specified and as directed by Engineer-in-Charge.
Supply only MCCB, 4 Pole, 200 Amps , with breaking capacity 36 KA ,with thermal magnetic setting adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II with suitable spraeders ; Complete all as specified and as directed by Engineer-in-Charge.
Supply only MCCB, 4 Pole, 100 Amps , with breaking capacity 36 KA ,with thermal magnetic setting adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II with suitable spraeders ; Complete all as specified and as directed by Engineer-in-Charge.
Supply only MCCB, 4 Pole, 63 Amps , with breaking capacity 36 KA ,with thermal magnetic setting adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II with suitable spraeders ; Complete all as specified and as directed by Engineer-in-Charge.
Supply only digital Amp meter (0-300Amp) along with CTs from existing LT Panel of any size ; Complete all as specified and as directed by Engineer-in-Charge.
Supply only digital Volt meter 0 to 600 volt , digital type from existing LT Panel of any size, ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for painting up to full height of LT Steel tubular pole 9 mtr long with two coats of aluminium paint and yellow and black paint in alternate of width 15 com from pole bottom upto 1.5 mtrs including prepartion of surfaces,Scraping the old paint and writing pole Number in Black letter under yellow circle ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for painting up to full height of LT Steel tubular pole 11 mtr long with two coats of aluminium paint including prepartion of surfaces,Scraping the old paint and writing pole No in Black letter under yellow circle ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below noRunning Metreal ground level with top edge of plate not less than 1.50 M below noRunning Metreal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion ; Complete all as specified and as directed by Engineer-in-Charge. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia upto 7.5 mtrs is deemmed to be included in rate quote ii) Excavation and returning filling of Soil any type is deemed to be included in the quoted rates.
Supply, installation, commissioning and testing of switch Air break, Gang operated with 12 insulator polymer type type switch Triple pole mechanicaly operated, mounted on insulator and steel frame, with mechanism worked from ground level, for current rating 400 Amp operating Voltage 11 KV out door type vertical mounted type complete with locking arrengement,assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity as per site requirement and as specified by Engr Incharge , complete with DO fuses assembly with channel and one No. operating Rod of 25 mm dia bore medium grade GI pipe of suitable length worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD incl nut,bolt, washers including taking down existing set ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in replacement of HT 11 KV out door non-linear type lightening arrestor with mountings, accessories complete fixed on cross aRunning Metres of two pole structure / GI flat strip and connect with same size of ACSR conductor encashed in PVC alkathine pipe with all fittings connected to earth strip with nuts, bolts and washers, transmission class having discharge capacity of 65 KA and rupturing capacity 5 KVA and suitable for working pressure 9 KV Running MetreS compelete including taking down old lightning arrestor all as specified and as directed including dismantling existing one ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for tracing faults in HT UG 11 KV XLPE with HT UG cable fault locating testing machine, rectifing the fault, putting the jointing kit and charging the cable as ; Complete all as specified and as directed by Engineer-in-Charge. Approx length 500 Running Metre for each Job. (The rate for excavation, removing of old cable, laying after repairs provn of new staright/ end joint is deemed to be included in the rate quoted by the contractor).
Supply and fixing LT line seperator 3/4 lines made of high quantity PVC material to provide 300 mm distance between phase to phase and neutal or as per sit reuirement ; Complete all as specified and as directed by Engineer-in-Charge.
Supply ,Installing, testing and commissioning in replacement LT panel board, factory made, out door, cubical type , veRunning Metrein proof, dust proof , water proof powder coated made out of 3.15 mm thick CRCA sheet and inner sheet of 2.0 mm thick and angle iron frame of size 50x50x5mm inside depth not less than 50 cm below and 0.4 mtr above ground level and size suitable to accommodate the following accessories, with insulated aluminium busbar 600camps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable dulypowder coated with minimum 7 tank porcess connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories ; Complete all as specified and as directed by Engineer-in-Charge. (a )MCCB 400 Amp four pole thermal magnetic setting 36 KA-01 No (Incoming) MAKE: Havells/ L & T / ABB (b) MCCB TPN 200 Amps Four Pole with breaking cap 36 KA - 03 Nos (For Out Going) Make:- Havells/ L & T / ABB . (c) MCCB 100 Amps 4 pole with breaking capacity 25 KA -03Nos (For Out Going) Make:- Havells/ L & T / ABB . (d) Volt Meter (digital Type (0 T0 500 Volts)-01 No (e) Ammeter (digital type) with CTs 0-400Amps)-01 No (f) Phase indication lamps LED type with holder-01 Set(Set of Three)Notes:- 1. The Panel Should be approved by CPRI. 2. The rates Quoted shall include for earth work and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
Supply and fixing in repairs cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts washers welding bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat on under coat and one finishing coat of paint ; Complete all as specified and as directed by Engineer-in-Charge.
Supply, erecting and fixing in repairs of true vertical position of steel tubular swaged pole, 9 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-31, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion up to 1.5 mtr length all as specified and directed. (Rate quoted shall be inclusive of Excavation and earth work , foundation concrete and PCC coping ; Complete all as specified and as directed by Engineer-in-Charge.
Supply, erecting and fixing in repairs of true vertical position of steel tubular swaged pole 11 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-55, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion up to 1.5 mtr length all as specified and directed. (Rate quoted shall be inclusive of Excavation and earth work , foundation concrete and PCC coping ; Complete all as specified and as directed by Engineer-in-Charge.
Supply, fixing and stringing ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size ; Complete all as specified and as directed by Engineer-in-Charge. (Note :- (a)jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumpers materials & tree branch cutting to make a safe distance from over head line.)
Material and Labour for repairs of Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for replacement of shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator bolts, washers and nuts, 100mm height and 115mm dia including two nos of galvanised steel strap of size 31x5mm fitted with 14mm dia bolts and nuts ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm ; Complete all as specified and as directed by Engineer-in-Charge. (loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately
Supply only insulating mat as per IS-15652, 2.5 mm thick suitable for 11 KV supply , ISI marked ( The Contractor will submit the test certificate for the mat) ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs silica gel with new one for transformer breatres ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs transformer breather made of transparent body and oil cup and unbreakkable UV portetced polycarbonate plastic suitable for transformer of capacity 100-200 KVA ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs transformer breather made of transparent body and oil cup and unbreakkable UV portetced polycarbonate plastic suitable for transformer of capacity 250-400 KVA ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs transformer breather made of transparent body and oil cup and unbreakkable UV portetced polycarbonate plastic suitable for transformer of capacity 500-630 KVA ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for LT cable end joint for cable of size 10sqmm 4 core to 25 sqmm 3.5 core ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for LT cable end joint for cable of size 35 sqmm 3.5 core to 70 sqmm 3.5 core ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for LT cable end joint for cable of size 95 sqmm 3.5 core to 120 sqmm 3.5 core ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for LT cable straight through joint for cable of size 10 sqmm 4 core to 25 sqmm 3.5 core ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for LT cable straight through joint for cable of size 35 sqmm 3.5 core to 70 sqmm 3.5 core ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for LT cable straight through joint for cable of size 95 sqmm 3.5 core to 120 sqmm 3.5 core ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for HT cable 11 KV end joint for cable of size 95 sqmm 3.0 core to 150 sqmm 3.0 core ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for HT cable 11 KV end joint for cable of size 185 sqmm 3.0 core to 300 sqmm 3.0 core ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for HT cable 11 KV straight through joint for cable of size 95 sqmm 3.0 core to 150 sqmm 3.0 core ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for repairs to transformer by replacement of LT/HT studs and their gaskets complete all as specified and directed after taking proper shut down , using all saftey equipments such as gloves safety belts short rods etc , by draing the transformer oil in clean transforer oil container upto bottom of bushing studs and replacing the worn out / burnt stud with same dia and same material incl all nuts bolts washers incl packing material and pouring the transformer oil removed for carrying out work incl topping up of oil if required ( oil will be measured and paid separatlety,) (Stud with nut washers gasket insulator thimble etc is deemed to be included in the rate quoted) ; Complete all as specified and as directed by Engineer-in-Charge for transformer of capacity 100 to 250 KVA
Material and Labour for repairs to transformer by replacement of LT/HT studs and their gaskets complete all as specified and directed after taking proper shut down , using all saftey equipments such as gloves safety belts short rods etc , by draing the transformer oil in clean transforer oil container upto bottom of bushing studs and replacing the worn out / burnt stud with same dia and same material incl all nuts bolts washers incl packing material and pouring the transformer oil removed for carrying out work incl topping up of oil if required ( oil will be measured and paid separatlety,) (Stud with nut washers gasket insulator thimble etc is deemed to be included in the rate quoted) ; Complete all as specified and as directed by Engineer-in-Charge for transformer of capacity 315 to 500 KVA
Supply only transformer oil of Die electric strenght not less than 60 KV Running Metres ; Complete all as specified and as directed by Engineer-in-Charge.
Supply ,Installing, testing and commissioning in replacement LT panel board, factory made, out door, cubical type , vermin proof, dust proof , water proof powder coated made out of 3.15 mm thick CRCA sheet and inner sheet of 2.0 mm thick and angle iron frame of size 50x50x5mm inside depth not less than 50 cm below and 0.4 mtr above ground level and size suitable to accommodate the following accessories, with insulated aluminium busbar 400camps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable dulypowder coated with minimum 7 tank porcess connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories ; Complete all as specified and as directed by Engineer-in-Charge. (a )MCCB 250 Amp four pole Thermal magnetic setting 36 KA-01 No (Incoming) MAKE: Havells/ L & T / ABB (b) MCCB TPN 100 Amps Four Pole with breaking cap 36 KA - 06 Nos (For Out Going) Make:- Havells/ L & T / ABB . (c) MCCB 63 Amps 4 pole with breaking capacity 25 KA -02 Nos (For Out Going) Make:- Havells/ L & T / ABB . (d) Volt Meter (digital Type (0 T0 500 Volts)-01 No (e) Ammeter (digital type) with CTs 0-400Amps)-01 No (f) Phase indication lamps LED type with holder-01 Set(Set of Three)
Bharat Builder
UNITED ENGINEERING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .