| Sl No | Description | Qty | Unit | MAJOR REFREGERATION AND ELECTRICALS L1 | M. S. CONTRACTOR L2 |
|---|---|---|---|---|---|
| .01BOQ (Repair/Maint of Split ACs, Window ACs, Desert Coolers, water coolers, refrigerator, deep freezer and allied E/M works at AF Stn Suratgarh) | |||||
| 1.00 | Split AC/ Window AC/ Tower AC: M&L for servicing of the Split AC/Tower AC/Window AC 1.5/2.0/3.0/4.0 ton capacity of any make ,including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles, proper connections of wires etc and re-fixing the air conditioner at its origional position by the experienced ref mech all as directed by Engr-in-Charge (Note :- (i) Any u/s items other than specified above need to be replaced/gas charging etc shall be replaced & paid under seperately respective items.(ii) Servicing of split type AC of capacity 1.5/2.0 TR capacity of any make by washing the outdoor unit condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower, wipe and clean the unit with dry cloth, complete all as specified and directed by Engg-in charge. | 347 | Each Job | 600 ₹2,08,200 | 550 ₹1,90,850 Lowest |
| 2.00 | M & L for cleaning / flushing out the refrigeration system thoroughly with CTC, leak testing with CO2 / N2 locating and rectifying the leaks by brazing with silver / copper rod, pressure testing, vaccumising and charging with refrigerant gas and topping up compressor oil, testing and commissioning complete for split type ACs of 1.5 Ton capacity complete all as specified and as directed.
(Note : (i) The quoted rate shall deemed to be inclusive of refrigerant gas (R-32/R-22/R-410A/R-134A)
(ii) Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any)). | 212 | Each Job | 1,000 ₹2,12,000 Lowest | 1,200 ₹2,54,400 |
| 3.00 | All as per Serial item No. 2 above but for 2.0/3.0/4.0 Ton capacity Split Acs/Tower AC complete. | 54 | Each Job | 1,200 ₹64,800 Lowest | 1,500 ₹81,000 |
| 4.00 | Material & Labour for taking down defective split type AC unit, shifting to work shop, taking out any type of defective compressor of capacity 1.5 Ton replacing the compressor with new Non Inverter compressor as suitable for existing, refixing the compressor in the unit, cleaning refrigeration system with CTC thoroughly, leak testing with refrigerant gas, testing at workshop, shifting to location, reinstalling the same in its original position, connecting up all electrical connections, testing and commissioning all as specified and directed.
Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation. | 10 | Each Job | 8,500 ₹85,000 Lowest | 9,000 ₹90,000 |
| 5.00 | All as described in serial item No.04 and above, but 2 ton capacity compressor for AC unit. | 5 | Each Job | 10,000 ₹50,000 Lowest | 10,500 ₹52,500 |
| 6.00 | All as described in serial item No.04 and above, but 3/4 ton capacity compressor for Tower AC unit. | 1 | Each Job | 15,000 ₹15,000 Lowest | 15,000 ₹15,000 Lowest |
| 7.00 | Material & Labour for taking down defective split type AC unit, shifting to work shop, taking out any type of defective compressor of capacity 1.5 T capacity from unit, replacing the compressor with new Inverter compressor as suitable for existing, refixing the compressor in the unit, cleaning refrigeration system with CTC thoroughly, leak testing with refrigerant gas, testing at workshop, shifting to location, reinstalling the same in its original position, connecting up all electrical connections, testing and commissioning all as specified and directed.
Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation. | 4 | Each Job | 9,000 ₹36,000 Lowest | 10,200 ₹40,800 |
| 8.00 | All as described in serial item No.07 and above, but 2 ton capacity compressor for AC unit. | 2 | Each Job | 10,000 ₹20,000 Lowest | 11,000 ₹22,000 |
| 9.00 | S & F in repairs Air cooled Condenser assembly including pipes connections and brazing to the units for 1.5/2.0 Ton capacity Split ACs complete all as per existing make and specifications and as directed. | 5 | Each Job | 3,000 ₹15,000 Lowest | 4,500 ₹22,500 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Jul 2025, 6:00 pmClosed
GE AF SURATGARH
GE AF SURATGARH
REPAIR/MAINT OF SPLIT ACS, WINDOW ACS, DESERT COOLERS, WATER COOLERS, REFRIGERATOR, DEEP FREEZER AND ALLIED E/M WORKS AT AF STN SURATGARH
2025_MES_713736_1
8241/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF SURATGARH
As per Tender Documents
10 documents required · 10 mandatory
₹500
GE AF SURATGARH
₹50,000
Yes
11 Aug 2025
11 Jun 2025
14 Jul 2025
11 Jun 2025
11 Jul 2025
26 Jun 2025
Amount
BOQ (Repair/Maint of Split ACs, Window ACs, Desert Coolers, water coolers, refrigerator, deep freezer and allied E/M works at AF Stn Suratgarh)
Split AC/ Window AC/ Tower AC: M&L for servicing of the Split AC/Tower AC/Window AC 1.5/2.0/3.0/4.0 ton capacity of any make ,including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles, proper connections of wires etc and re-fixing the air conditioner at its origional position by the experienced ref mech all as directed by Engr-in-Charge (Note :- (i) Any u/s items other than specified above need to be replaced/gas charging etc shall be replaced & paid under seperately respective items.(ii) Servicing of split type AC of capacity 1.5/2.0 TR capacity of any make by washing the outdoor unit condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower, wipe and clean the unit with dry cloth, complete all as specified and directed by Engg-in charge.
M & L for cleaning / flushing out the refrigeration system thoroughly with CTC, leak testing with CO2 / N2 locating and rectifying the leaks by brazing with silver / copper rod, pressure testing, vaccumising and charging with refrigerant gas and topping up compressor oil, testing and commissioning complete for split type ACs of 1.5 Ton capacity complete all as specified and as directed. (Note : (i) The quoted rate shall deemed to be inclusive of refrigerant gas (R-32/R-22/R-410A/R-134A) (ii) Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any)).
All as per Serial item No. 2 above but for 2.0/3.0/4.0 Ton capacity Split Acs/Tower AC complete.
Material & Labour for taking down defective split type AC unit, shifting to work shop, taking out any type of defective compressor of capacity 1.5 Ton replacing the compressor with new Non Inverter compressor as suitable for existing, refixing the compressor in the unit, cleaning refrigeration system with CTC thoroughly, leak testing with refrigerant gas, testing at workshop, shifting to location, reinstalling the same in its original position, connecting up all electrical connections, testing and commissioning all as specified and directed. Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation.
All as described in serial item No.04 and above, but 2 ton capacity compressor for AC unit.
All as described in serial item No.04 and above, but 3/4 ton capacity compressor for Tower AC unit.
Material & Labour for taking down defective split type AC unit, shifting to work shop, taking out any type of defective compressor of capacity 1.5 T capacity from unit, replacing the compressor with new Inverter compressor as suitable for existing, refixing the compressor in the unit, cleaning refrigeration system with CTC thoroughly, leak testing with refrigerant gas, testing at workshop, shifting to location, reinstalling the same in its original position, connecting up all electrical connections, testing and commissioning all as specified and directed. Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation.
All as described in serial item No.07 and above, but 2 ton capacity compressor for AC unit.
S & F in repairs Air cooled Condenser assembly including pipes connections and brazing to the units for 1.5/2.0 Ton capacity Split ACs complete all as per existing make and specifications and as directed.
S & F in repairs condenser fan blades of 1.5/2.0/3.0 Ton capapcity split Acs, balancing for smooth rotation in the casing and testing complete all as per existing make and specifications and as directed. (Make: Carrier/Voltas/Amtrex/Blue Star/LG/Carrier)
S&F in replacement 3 Phase power contactor for tower AC 4 TR capacity suitable for particular make of AC and making proper connection and testing, complete all as speciifed and directed.
S&F in replacement phase preventer for tower AC 4 TR capacity suitable for particular make of AC and making proper connection and testing, complete all as speciifed and directed.
S & F in repairs Temperature sensor probe in the main circuit suitable for 1.5/2.0/3.0/4.0 Ton capacity split Acs/Tower AC complete as per the existing make and specifications and as directed.
S & F in repairs PCB Card suitable for 1.5/2.0/3.0/4.0 Ton capacity split ACs/tower ACs, non Inverter type complete as per the existing make and specifications and as directed.
S & F in replacement PCB Card suitable for 1.5/2.0/3.0/4.0 Ton capacity split ACs/tower ACs, Inverter type complete as per the existing make and specifications and as directed.
S & F in replacement PCB card with new suitable for all split type Acs/Tower ACs of 1.5 / 2.0/3.0 Ton capacity Non inverter type complete as per the existing make and specifications and as directed.
S & F in replacement PCB card with new suitable for all split type Acs/Tower Acs of 1.5 / 2.0/3.0 Ton capacity complete indoor and outdoor of Inverter type complete as per the existing make and specifications and as directed.
S & F in replacement of u/s Remote controller suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs, complete as per the existing make and specifications and as directed.
Taking down indoor unit fan motor of evaporator unit air conditioner of any make/type of 1.5/2.0/3.0 Ton capacity and replacing the same with new motor of same rating, with copper winding, single phase, 200/230 volt, 50 Hz, in the same position and testing etc complete all as specified and as directed.
All as per Serial item No. 19 above but for indoor unit of 3.0/4.0 Ton tower ACs complete ditto.
Taking down out door unit fan blower motor from air conditioner of any make/type of 1.5/2.0/3.0 Ton capacity and replacing the same with new motor of same rating, with copper winding, single phase, 200/230 volt, 50 Hz, in the same position and testing etc complete all as specified and as directed.
All as per Serial item No. 21 above but for indoor unit of 3.0/4.0 Ton tower ACs complete.
S & F in repairs thermal Starting relay suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs all as per the existing make and specifications and as directed.
S & F in repairs Running capacitor of 45 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed.
S & F in repairs Running capacitor of 50 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed.
S & F in repairs Running capacitor of 80/100 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed.
S & F in repairs indoor/outdoor unit fan motor capacitor of 4/6 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed.
S & F in repairs fine filter suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs all as per the existing make and specifications and as directed.
S & F in repairs Drain connection with drain trap suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs all as per the existing make and specifications and as directed.
S & F in repairs PVC pipe, 25mm dia as in drain pipe for each split AC including necessary fittings such as elbow/bends/clamps etc of suitable size fixed to wall or ceiling complete all as specified and as directed.
Taking down the unserviceable service valve of suction and liquid line and supply and fix new service valve suitable for 1.5 / 2.0/3.0 Ton capacity split type ACs including necessary nut & bolts, gaskets and brazing to the respective line with silver / copper rod and checking for the leakage complete all as per existing make and specifications and as directed.
S & F in repairs delivery/discharge valve suitable for 1.5/2.0/3.0 Ton capacity Split ACs all as per the existing make and specifications and as directed.
S & F in repairs capillary tube set suitable for 1.5/2.0/3.0 Ton capacity Split ACs all as per the existing make and specifications and as directed.
S & F in replacement of MS stand for mounting outdoor unit of Split Acs of capacity 1.5/2.0/3.0 Ton complete all as per the existing make and specifications and as directed.
S & F in replacement of copper tubing of 5/8" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in replacement of copper tubing of 3/8" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in replacement of copper tubing of 1/4" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in replacement of copper tubing of 1/2" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in replacement of Insulation for copper tubing of 5/8" dia of Split ACs complete all as per the existing make specification and as directed
S & F in replacement of Insulation for copper tubing of 3/8" dia of Split ACs complete all as per the existing make specification and as directed.
S & F in replacement of Insulation for copper tubing of 1/4" dia of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs Insulation for copper tubing of 1/2" dia of Split ACs complete all as per the existing make specification and as directed.
S & F in replacement of Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 2.5 sqmm complete all as specified and as directed.
S & F in replacement of Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 4 sqmm complete all as specified and as directed.
S & F in replacement of Four core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 2.5 sqmm complete all as specified and as directed.
M & L for Repairs to voltage stabiliser of any make / phase with input voltage 135-190V and output voltage 200-240 Volts, capacity upto 5 KVA by dismantling and taking our burnt main transformer and rewinding with suitable guage super enamelled copper wire, varnishing, etc., complete including replacement of unserviceable/defective voltmeter, 0-300 volts complete all as specified and as directed. (Note: Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any))
S & F in replacement u/s voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 180 V to 270 V with output of 230V with accuracy of +/- 2.5% variation of capacity of 5 KVA complete all as specified and directed.
Supply and filling R134A/R32/R410A/R600/R-22 Gas for all types of AC Units complete all as specified and as directed.
Taking down /shifting of Split type ACs of any capacity/type after disconnecting all connections etc and re-fixing in the same position or any other specified position as directed by the Engr-in-Charge after carry out minor repairs works, filling the suitable of gas etc complete all as specified and as directed. (Note: Unit quoted rate shall deemed to be inclusive of transportation cost & Gas filling charges)
Attending complaints related to Air Conditioning including replacement & minor repairs like reconnections,Stabilizer reconnections, Water leakage from AC, Wire fault rectification, replacement of Supply only items, replacement of screw/washers any type & size, insulation tape replacement etc and obtaining completion of user on complaint slip, complete all as specified and as directed by engineer-in-charge.
Window Type AC s : Taking down the defective compressor from the unit and supply and fix new and factory sealed compressor of same make (including cleaning refrigeration circuit with ,cleaning agents flushing through with CO2/N2,complete removal of dirt,oil and carbon etc pressure testing dehydrating, vaccuming, replacment of copper pipe,copper stainer,topping up com pressor oil ) testing and commissioning of window type AC units 1.5/2.0 Ton capacity.Note:- Charging of R-32/R-22 gas will be measured and paid under relevent item of schedule
Supply and fix in repairs air cooled condenser assembly including pipe connections and brazing to the units for 1 Ton/1.5 Ton capacity window type AC complete all as specified and as directed.
Supply and fix in replacement of running capacitor suitable for 1 Ton/1.5 Ton/2 Ton capacity window type AC complete all as specified and as directed.
Suplly and fix in replacement of starting relay suitable for 1 Ton/1.5 Ton/2 Ton capacity window type AC complete all as specified and as directed.
Supply and fix in replacement of fan motor capacitor suitable for 1 Ton/1.5 Ton/2 Ton capacity window type AC complete all as specified and as directed.
Supply and fix in repairs new fan blades suitable for 1 Ton/1.5 Ton/2.0 Ton capacity window type AC complete all as specified and as directed.
Supply and fix in replacement of new fan motor suitable for existing 1 Ton/1.5 Ton/2.0 Ton capacity window type AC complete all as specified and as directed.
Supply and fix in repairs new air filter of PVC type suitable for 1 Ton/1.5 Ton/2.0 Ton capacity window type AC complete all as specified and as directed.
Supply and fix in repairs new thermostatic switch for window type AC s complete all as specified and as directed. Make: Indfoss/Ranutrol.
Supply and fix in repairs oscillation motor assembly with louvers for window type AC complete all as specified and as directed.
Supply and fix in replacement of air cooled cooling coil for window type AC s complete all as specified and as directed.
Supply and fix in repairs front grill assembly for 1.5 ton/2.0 ton capacity window AC complete all as specified and as directed.
Removal of the unserviceable temperature sensor probes and supply and fix new temperature sensor probes in the main circuit of split type AC complete all as specified and as directed.
S & F in replacement PCB card suitable for window type AC s of 1.5 / 2 Ton capacity complete all as specified and as directed.
M&L for replacement of sub-main wiring (concealed) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massinory including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. Note:- The disturbed surfaces of wall for concealing the wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate for point wiring shall be deemed to include the cost of making good.
M&L for replacement of sub-main wiring (existing concealed PVC/steel conduit) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massinory including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge.
S/F sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amps , 240 Volts, Make :-Havelles/ Legrand/L&T.
Supply & Fixing in replacement of 3 core 6 sqmm PVC insulated PVC sheathed weather proof multistranded aluminium conductor cable 1100 volts grade laid in trenches/wall drawn through in PVC Conduit all as specified and directed.
Supply & Fixing in replacement of PVC conduit (25mmdia) inclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc.
Desert Coolers:- Dismantling and taking out water pump, fan motor and water distribution pipes from the desert cooler, carrying out minor repairs to set the damaged/bent up parts by means of hammering/welding/riveting as required, removing existing paint/treatment completely preparing the surface and fixing the pads to shutters rearranging the pads and refixing motor pump, PVC pipe, distributor and shutters in existing position, complete all as specified and directed.
Dismantling and rewinding Fan motor of desert cooler with suitable size of super enameled copper wire including replacement of bush, insulating material, greasing, testing and refixing, complete all as specified and directed.
Taking down old unserviceable PVC flexible tubing, distributor and elbows and providing PVC flexible tubing distributor and elbows for desert cooler, complete all as specified and directed.
S&F in replacement Fan motor with suitable capacity of desert cooler, AC, single phase, 230V, 50 Hz, three speed complete with capacitor, blades and brackets including necessary wiring complete all as specified and directed.
S&F in replacement capacitor of 3.15/4.00 MFD suitable for fan motor of desert cooler complete all as specified and directed.
S&F in replacement submersible pump of desert cooler single phase AC, 230 Volts, 50 Hz including necessary connection and testing, complete all as specified and directed.
S&F in replacement side shutter with handle made of galvanised MS sheet 26 Gauge as per existing size complete with wood wool pad and wire mesh, complete all as specified and directed.
S&F in replacement front grill of desert cooler made out of GI sheet 22 Gauge complete with air diversion control fins of existing size, complete all as specified and directed.
S&F in replacement bottom tank, top corner and 04 corner pieces made out of galvanised MS sheet 22 Gauge for desert cooler of any capacity (capacity of 50 liter approx) including dismantling and refixing of the accessories in the new unit, complete all as specified and directed.
S&F in replacement PVC fan blade of desert Cooler suitable for any make and capacity, complete all as specified and directed.
S&F in replacement PVC sheathed 3 core cable with copper conductor size 23/.0076 for water cooler/ Desert cooler/refrigerator, complete all as specified and directed.
S&F in replacement new wooden wool pad of minimum size (45cmx60cm ) of best quality as approved by GE for desert cooler, complete all as specified and directed.
S&F in replacement bush shaft of blower motor of Desert cooler suitable for any make and capacity including necessary connection and testing, complete all as specified and directed.
S&F in replacement push cock, of brass chromium plated, 15mm bore, including taking over old push cock, complete all as specified and directed.
S&F in replacement 15mm bore PTMT float valve assembly with PVC float for water cooler, complete all as specified and directed.
M&L for preparation of old painted surfaces and applying one coat spray painting of synthetic enamel paint (colour as approved ) outside and two coats of black bituminous paint inside of desert cooler of any make after removal of all dust and all foreign matter with the help of sand paper and rubbing with cleaning compound, complete all as specified and directed.
M&L for replacement of point wiring complete with 1.5 Sqmm (nominal area) FRLS PVC insulated, multi stranded, copper conductor cable unsheathed in existing concealed PVC/Steel conduit and FRLS PVC insulated copper conductor cable of size 1.5 sq mm as earth wire , connected to common earth dolly and replacement of aminated sheet cover of 3 mm thick for mounting swiches,socket,regulator suitable for mounting switches all as specified and as directed by Engr-in-charge for the following :- (a) One 3 pin socket outlet 5 amps on independent board. Water Cooler, Deepfreezer and Refrigirator:
Water Cooler: Disconnecting old defective burnt sealed compressor unit of water cooler of any capacity and replacement of same with new sealed compressor unit including soldering of copper pipes, foundation rubber bushes, nut bolts cleaning the refrigerant system, charging of compressor oil and refrigerant and testing, complete all as specified and directed.
Testing of water cooler, cleaning the gas system with CTC of nitrogen vacuumising properly and charging the refrigerant R-134A including the cost of gas filters/ rectification of leakage in entire system and making the gas system leak proof to the entire satisfaction of Engineer-in-Charge, complete all as specified and directed.
S&F in replacement condenser fan motor 1/5 HP complete with blades suitable for water cooler any, complete all as specified and directed.
S&F in replacement combination relay unit complete suitable for water cooler any capacity, complete all as specified and directed.
S&F in replacement of starting capacitor for 40/80, 150 ltr water cooler complete all as specified and as directed.
S&F in replacement running capacitor 60 to 80 MFD suitable for water cooler, complete all as specified and directed.
S&F in replacement of fan motor capacitor 4 to 6 MFD suitable for water cooler, complete all as specified and directed.
S&F in replacement over load protector including clips suitable for water cooler, complete all as specified and directed.
S&F MS chromium plated drip tray assembly of water cooler complete with elbow complete all as specified and as directed.
S & F in Replacement of unserviceable float valve with new polythene ball suitable for 15mm dia GI pipe complete all as specified and as directed.
Taking old unserviceable water tap 15mm bore and S&F new self closing chromium plated push cock 15mm bore heavy duty complete all as specified and as directed.
M&L for cleaning of water cooler complete internally and externally including scraping and removing all scales and dirt etc. applying two coats of synthetic enamel hammer tone paint over one coat red oxide of primer and writing of SM/MES No in 3 cm high complete all as specified and as directed. Make of paint :M/s. Asian Paints [Apcolite], M/s. Berger Paints [Luxol], Jenson & Nicholson [Brolac] all are 1st quality.
S&F in replacement PVC fan blade of blower motor of water cooler suitable for any make and capacity, complete all as specified and directed.
Refrigerator:- Disconnecting old defective burnt sealed compressor unit of Refrigerator 190/215/310 ltr capacity of any make and replacement of same with new sealed compressor unit including soldering of copper pipes, foundation rubber bushes, nuts bolts, cleaning the refrigerant system and charging of refrigerant and testing, complete all as specified and directed.
All as per Srl item No-101 here-in-before but capacity 165/180 ltr, complete all as specified and directed.
Replacement of pgmy lamp (bulb) as per the existing complete all as specified and as directed.
Replacement of unserviceable over load protection with new Over load relay (OLR) for refrigerator 310/286/165 ltr capacity complete all as specified and as directed. Make : Renutral/Shriram.
Cleaning the gas system with CTC vacuum pump and charging the refrigerant R-134A with antimoist substance and filter along with rectification of leakage in the system of 165/286/310 ltr capacity refrigerator, complete all as specified and directed.
S&F in replacement thermostat switch with defrosting arrangement suitable for Refrigerator 286/310/165 ltr capacity including knob plate and screw, complete all as specified and directed.
Deep freezer:- Disconnecting old defective burnt sealed compressor unit of deep freezer 425/500 ltr capacity of any make and replacement of same with new sealed compressor unit including soldering of copper pipes, foundation rubber bushes, nuts bolts, cleaning the refrigerant system and charging of refrigerant and testing, complete all as specified and directed.
Cleaning the gas system with CTC vacuum pump and charging the refrigerant R-134A with antimoist substance and filter along with rectification of leakage in the system of 285/425/500 ltr capacity deep Freezer, complete all as specified and directed.
S&F in replacement thermostat switch with defrosting arrangement suitable for deep freezer 425/500 ltr capacity including knob plate and screw, complete all as specified and directed.
S & F in Replacement of unserviceable over load protection with new Over load relay (OLR) for refrigerator 310/286/165 ltr capacity complete all as specified and as directed. Make : Renutral/Shriram.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
M. S. CONTRACTOR (BID ID -3353396)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .