Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-2₹28.7 L+₹49,590 (1.76%)Accepted-Finance | L-2 | Accepted-Finance Qualified | |
| 2 | L-3₹29.9 L+₹1.7 L (5.87%)Accepted-Finance HOUSING COLONY UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-3 | Accepted-Finance Qualified | |
| 3 | L-4₹32.9 L+₹4.7 L (16.8%)Accepted-Finance | L-4 | Accepted-Finance Qualified | |
| 4 | L-5₹33.3 L+₹5.1 L (18.2%)Accepted-Finance | L-5 | Accepted-Finance Qualified | |
| 5 | L-1₹28.2 LRejected-Finance | L-1 | Rejected-Finance insufficient Experience |
Tender Value
Refer Docs
EMD Value
₹75,600
Closing Date
6 Sept 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Electric Division JPDCL Udhampur
(i)Installation of PCC Poles in Jaganoo (ii) HT.LT Poles (iii) Electric Poles Majalta (iv) Electric Poles at Different Pyts. DDC Udh I Constituency (v) 63 KVA Sub Stn. Urban Turban Dhaba Pyt. Battal (vi) 25 KVA Sub Stn.Pyt Sulghar under DDC Grants
2024_PDD_257813_1
Ed/Udh/17 of 2024-25 dt. 16-08-2024
Open Tender
Electrical Works
Turn-key
120 days
District Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric DivisionJPDCL
₹75,600
17 Oct 2024
16 Aug 2024
7 Sept 2024
16 Aug 2024
6 Sept 2024
16 Aug 2024
16 Aug 2024 - 23 Aug 2024
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. PCC poles, 30 mm sq. ACSR Weasel Conductor for installation of PCC poles with fuse conductor (Complete accessories) in Block Jaganoo under DDC Grants
8 mtr. Long PCC poles (PCC-WL-200kg)
GI U Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. PCC & ST poles, 30 mm sq. ACSR Weasel Conductor for HT/LT poles alongwith allied material under DDC Grants.
8 mtr. Long PCC poles (PCC-WL-200kg)
8 mtr. Long ST Pole (ST-410 SP-15)
GI Mukki Clamps for shackle insulator
GI U Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with one coat of Red Oxide.
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. PCC & ST poles, 30 mm sq. ACSR Weasel Conductor for Provision of Electric Poles in Block Majalta under DDC Grants.
8 mtr. Long PCC poles (PCC-WL-200kg)
8 mtr. Long ST Pole (ST-410 SP-15)
GI Mukki Clamps for shackle insulator
GI U Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with one coat of Red Oxide.
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. PCC poles, 30 mm sq. ACSR Weasel Conductor for Electric Poles at different Panchayats of DDC Udh I Constituency under DDC Grants
8 mtr. Long PCC poles (PCC-WL-200kg)
GI U Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Installation of 63 KVA transformer near Urban Turban Dhaba, Pyt. Battal, DDC Udh-II under DDC Grants
11/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
120mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long ST pole (ST-410 SP-33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
GI Channel /Angle/flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Poloymer composite pin insulator, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
LT Fuse Switch made of angle Iron 50X50X6, with aluminium Bus Bar strip 50X6mm fixed on Bus Bar Insualtor including clamps for fixing of switch
Danger Plates with Clamps
GI Barbed wire for Anticlimbing
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. Long with 2 coat of Al. paint
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. PCC poles, 30 mm sq. ACSR Weasel Conductor for Installation of 63 KVA transformer near Urban Turban Dhaba, Pyt. Battal, DDC Udh-II under DDC Grants.
8 mtr. Long PCC poles (PCC-WL-200kg)
GI U Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 11 KV line on 9 mtr long ST poles, 30 mm sq. ACSR Weasel Conductor forInstallation of 25KVA transformer along with poles Pyt sulghar Block Ghordi under DDC Grants
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
30mm² ACSR Weasel Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Installation of 25KVA transformer along with poles Pyt sulghar Block Ghordi under DDC Grants
11/0.433 KV, 3-phase distribution Transformer 25 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
70mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long ST pole (ST-410 SP-33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
GI Channel /Angle/flat of sizes including clamps
Galvanized Nuts and Bolts.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
LT Fuse Switch made of angle Iron 50X50X6, with aluminium Bus Bar strip 50X6mm fixed on Bus Bar Insualtor including clamps for fixing of switch
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. ST poles, 30 mm sq. ACSR Weasel Conductor for Installation of 25KVA transformer along with poles Pyt sulghar Block Ghordi under DDC Grants
8 mtr. Long ST Pole (ST-410 SP-15)
GI Mukki Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
VEENA CONSTRUCTION CO.
KULDEEP KUMAR SUDAN
M/S D.K TRADERS
JAI CHANDI MAA ENTERPRISES
SWASTIK ELECTRICAL AND CONSTRUCTION WORKS
SATYAM CONSTRUCTION & TRADING COMPANY
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .