Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC NO 1 1ST MAIN ANANDNAGAR ATRIA INSTITUTE OF TECHNOLOGY CAMPUS HEBBAL BANGALURU 560 024 | BENGALURU URBAN | KARNATAKA | 560024 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹49.4 L+₹2.4 L (5.12%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L2 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
27 Nov 2021, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
DOOR TO DOOR MAINTENANCE FOR ROUTINE B R AND E M COMPLAINTS CLEANING OF OVER HEAD TANKS PERIODICAL SERVICES CLEANING AND REMOVAL OF BLOCKAGES IN KITCHEN TOILETS AND REPAIRS TO INTERNAL ELECTRIFICATION TO MARRIED OTM ACCN BUILDINGS OF DGQA IN THE
2021_MES_474890_2
8260
Open Tender
Civil Works
Item Rate
270 days
Bangalore
Class D category a(i) b(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹86,000
Yes
7 Dec 2021
9 Nov 2021
29 Nov 2021
9 Nov 2021
27 Nov 2021
15 Nov 2021
9 Nov 2021 - 14 Nov 2021
Amount
B/R WORKS
Extruded alloy handles fabricated type anodised of size 100 mm fixed in repairs complete all as specified and as directed.
Extruded alloy handles fabricated type anodised of size 150 mm fixed in repairs complete all as specified and as directed.
100 mm size hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws,fixed in repairs complete all as specified and as directed.
40 mm dia cupboard knobs fixed with nuts, screws and washers of brass, polished complete fixed in repairs complete all as specified and as directed.
Aluminium anodised barrel towel bolts of extruded section of length 150 mm fixed in repairs complete all as specified and as directed.
Aluminium anodised barrel towel bolts of extruded section of length 200 mm fixed in repairs complete all as specified and as directed.
Aluminium anodised barrel towel bolts of extruded section of length 75 mm fixed in repairs complete all as specified and as directed.
300mm long Aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed in repairs complete all as specified and as directed.
150 mm long floor door stopper of aluminium alloy powder coated, with hard down steel spring complete fixed in repairs all as specified and as directed.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with MS screw and bolts in repairs all as specified and as directed.
Door closer hydraulically regulated designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg of aluminium (Die cast body) fixed in repairs complete all as specified and as directed.
Mild steel 300mm long, ordinary rat tail rod pattern springs,including roller and roller plate complete fixed in repairs all as specifed and as directed.
Mild steel,chromium plated curtain rod 20mm dia with fixing brackets complete fixed in repairs all as specified and as directed.
Drapery rods, 25 mm dia, having corrugated PVC extrusion on electric resistance welded MS pipe with fancy type 02 Nos knob and 02 Nos brackets for each door/windows etc complete all as specified directed. Make : soffio II of Vista or equivalent.
4 mm thick figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sqm in each pane including hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
3 mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in wooden frames in squares not exceeding 0.5 sqm in each pane all as directed.
Resecuring or easing and adjusting without taking down shutters of any description area exc. 1 sqm but n.exc. 2 sqm each all as specified and as directed.
Repairs to steel windows/ventilators by necessary cutting, welding, greasing/oiling to hinges, replacing the projecting type hinges with box type hinges etc and make the window smoothly functionable all as specified and directed. NOTE:- Glass pane, wire mesh if provided will be measured and paid separately.
Kitchen sink made of stainless steel 1mm thick kitchen with plugs, washers and wastes: including bedding in cement mortar to dwarf wall or including fixing cantilever brackets or fixing in granite slab and connecting union to pipe overall size 495mm x 420mm bowl size 410mmx 330mm x 160mm complete fixed in reoairs all as specified and as directed.
Vitreous china wash down water closet pan (pedestal pattern) white excluding flushing cistern and flush pipe) , including connection to drain & or out going pipe and to flushing pipe, anti syphonage pipe ,including seat and cover complete all as specified and as directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC(SWR) 'P' or 'S' trap connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor fixed in repairs complete all as specified and directed.
Vitreous china wash basin white flat back of size 630 x 450 mm excl taps,chain and plug and porcelain stopper but incl CI bracket. etc complete fixed in repairs all as specified and as directed.
PVC valveless, syphonic action type, flushing cistern, 10ltr capacity,low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed.
Plastic water closet seat cover, coloured, for pedestal pan closed pattern with flat bottom,and cover with mild steel chromimium plated or aluminised hinging device complete fixed inrepairs all as specified and directed.
Taking up or down steel tubing 15mm dia and connections including cleaning for refixing or removal to store all as directed.
Taking up or down steel tubing 20mm dia and connections including cleaning for refixing or removal to store all as directed.
Taking up or down steel tubing 25mm dia and connections including cleaning for refixing or removal to store all as directed.
20mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
25mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
Brass CP wall mixer for mixing hot and cold water screwed down for iron pipe and fixed in repairs complete all as specified and directed.
Brass chromium plated overhead shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union fixed in repairs complete all as specified and as directed.
Bib taps 15mm dia, fancy type, chromium plated, screwed down, screwed for iron pipe fixed in repairs complete all as specified and as directed.
Pillar taps, fancy type, 15mm dia cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe fixed in repairs complete all as specified and as directed.
Stop valves 15mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, fixed in repairs complete all as specified and as directed.
Stop cock 15mm dia, chromium plated, concealed, fancy type with long shank and cup fixed in repairs complete all as specified and as directed.
Angle valves 15mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and as directed.
15mm dia Bib tap long body all as per Cat No. 7808 of Prayag or techno commercially equivalent of Hindware /Parryware/Cera fixed in repairs complete all as specified and as directed
Health faucet of fancy type, chromium plated including two way chromium plated bib cock and PVC connecting pipe of length 90 to 120 cm length all as per Cat No. BEA-41 & 7812 of Paryag or equivalent of Hindware/Parryware/Cera fixed in repairs complete all as specified and as directed.
Taking down existing bib taps, Pillar taps, stop cock or angle valve of any size and re fixing in old or new position including replacing one nylon washer complete all as specified and as directed.
All as per Sl Item No. 1.039 here-in-before but replacing brass spindle.
Brass chromium plated fancy type towel rail 600mm long of CERA, Model no: CA303 or equivalent in other makes specified as fixed in repairs with brackets complete all as specified and directed.
Bib taps standard of PTMT, any colour screwed for iron pipe suitable for 15mm dia fixed in repairs all as directed.
15mm dia Pillar tap PTMT fancy type any colour screwed, for iron pipe and fixed in repairs complete all as specified and as directed.
15mm dia angle stop valve of PTMT any colour pressed screwed, for iron pipe and fixed in repairs complete all as specified and as directed.
PVC connections 15mm dia with PTMT nuts of length of 600 mm long fixed in repairs complete all as specfied and as directed.
PVC connections 15mm dia with PTMT nuts of length of 450 mm long fixed in repairs complete all as specfied and as directed.
PTMT waste coupling of 32 mm dia (half or full threaded) including taking down old coupling of any description complete all as specified and directed.[Minimum weight for 32 mm – 45 gms].
PTMT waste coupling of 40mm dia (half or full threaded) including taking down old coupling of any description complete all as specified and directed [Minimum weight for 40 mm – 60 gms].
32 mm dia waste fittings, brass, chromium plated for sinks, basins, etc., with long screwed shanks and flynuts, flange end fixed in repairs complete all as specified and as directed.
40 mm dia waste fittings, brass, chromium plated for sinks, basins, etc with long screwed shanks and flynuts, flange end fixed in repairs complete all as specified and as directed.
PVC corrugated waste pipe 40mm dia, 800mm long fixed in repairs complete all as specified and as directed.
PVC corrugated waste pipe 32mm dia, 800mm long fixed in repairs complete all as specified and as directed.
PVC sintex tank cover suitable for circular tanks including hinges and locking arrangements fixed in repairs complete all as specfied and as directed.
75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement. complete all as specified and as directed.
Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
75 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings fixed in repairs complete all as specified and as directed.
110 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings fixed in repairs complete all as specified and as directed.
75mm bore PVC (SWR) bends, type 'B' with access door complete all as specified and as directed.
110mm bore PVC (SWR) bends, type 'B' with access door complete all as specified and as directed.
20mm dia Ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed(Min weight 20mm-210 gms) all as specified and as directed.
Gun metal gate or globe valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Gun metal gate or globe valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the the premises complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.06 sqm but n.exc . 0.11 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.11 sqm but n.exc . 0.18 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Glazed coloured ceramic tiles as in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including backing coat 10mm thick in CM (1:4) on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Taking down cement plaster of any description including racking out joints, hacking for key and disposing of debris to out side MD land all as specified and as directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:4) and finishing the surface with even and smooth without using extra cement all as specified and as directed.
15 mm thick rendering in CM (1:6) on fair faces of brickwork or concrete surfaces and finished even and smooth without using extra cement all as specified and as directed.
Rendering 5 mm thick on ceiling / RCC surfaces in cement mortar (1:3), finished plastered surface even and smooth without using extra cement all as specified and as directed.
Preparation of new plaster surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of oil bound emulsion distemper of approved tint over a coat of alkali reistant primer on wall complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer all as specified and as directed.
Prepartation of new or previously un treated wall surfaces of any description and applying three coats white wash complete all as specified and as directed.
Clearing of sewage line blockage from nahani trap/ gully trap to first manhole, cleaning eye of down take pipe and removing all debris, sludge and solid material from the traps/ cleaning eyes and removal from site and well flushing with water after clearing the blockage of pipes in any dia at any position all as specified and as directed by Engineer-in-Charge.
110mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement. complete all as specified and as directed.
PVC (SWR) multi floor trap 110mm dia type 'B' with grating including joint with solvent cement complete all as specified and directed.
Supply only Integral liquid water proofing compound all as specified and as directed.
Providing and laying water proofing treatment to sunken portion of WCs, bathroom and kitchen etc by applying cement slurry mixed with two component elastomeric acrylic based polymer modified cementitious composite compound coating of make as approved in TI 5/2003 including demolition and removal of existing treatment of any type with the following procedure in sequence all as specified and as directed:- (i) Demolition of existing treatment of any type including cleaning and removal of debris from site. (ii) First layer of cement slurry @ 0.488 kg/sqm of cement mixed with acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm, the layer will be allowed to air cure for 4 hours. (iii) Second layer of cement slurry @ 0.242 kg/sqm of cement mixed with with acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm, the layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (iv) 20mm thick screed in cement mortar (1:3) mixed with including supply of liquid water proofing compound as per manufacturers instructions. Contd.. 1.80
Contd.. 1.79 (v) Ponding the treated portion atleast 48 hours, if any leakage / seepage observed the entire procedures will be repeated without any extra cost. (vi) Provide 40mm dia light grade GI spout at the lowest point with 30cm projection beyond the out face of the wall. (vii) Sunken portion shall be filled with lean cement concrete(1:5:10), type E-2 using 40mm graded stone aggregate. NOTE :- (i) The sunken slab sloped towards outer face to drain the water in to GI spout pipe. (ii) Coving shall be provided at the junction of slab with the wall. (iii) Nahni trap shall be 10mm below finished floor level and drain pipe dia is larger than the nahni trap size. (iv) The outer end of the spout should be chamfered. (v) mode of measurement : plan/floor area will be measured.
PVC (SWR) branch piece, type 'B' double (double Y) equal or unequal 75mm dia, type 'B' with access door fixed in repairs complete all as specified and as directed.
PVC (SWR) branch piece, type 'B' double (double Y) equal or unequal 110mm dia, type 'B' with access door fixed in repairs complete all as specified and as directed.
Material and labour for spraying antiweed / non toxic solution / chemicals containing Glyphosate as per manufacture instructions and removing the weed including the roots after ensuring complete de-germification of palnt/weed and cutting down the plant/trees off from roof/top sides of external walls of bldgs, in chajjas, wall junctions, junctions of GI/CI/AC/PVC pipes and taking out roots entered in wall/slabs, including making good the surface using PCC 1:2:4 type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered with CM(1:4) to match with existing surface and repairing the pipes and joints which was affected by cutting down/taking out process all as specified and as directed for plants / trees located in the buildings upto four storey high, complete all as specified and directed by Engineer-in-charge. NOTE:- Contractor has to execute the work of de-generated plant/weeds as per the prior approval and directions of Engineer-in-charge.
Material and labour for cleaning of PVC/RCC over head water tanks at any height (on accessable / inaccessable roofs) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus and any other bacterial material from sides/bottom of tank, cleaning shall be done by draining / pumping out water / sludge from bottom, by high pressure water jet of pressure rating not less than 120 PSI for removing clogged mud/scales etc and cleaning the same again with self priming pumped fresh water and disinfecting the water tank by using UV radiator and approved chemical (chlorite), after cleaning writing letters / figures (Date of cleaning and next Date of cleaning) on black back ground with white synthetic enamel paint including removing the existing letters/ figures complete all as specified and as directed for capacity of water tank exc. 250 litre and n.exc. 500 ltr capacity complete all as specified and as directed. NOTE FOR SL ITEM NO. 1.01 to 1.03:- (i) Contractor has to ensure that there is no damage / leakage in tank after cleaning . (ii) Any air lock /blockage of water flow after cleaning will be made good immediately.
All as per Sl Item No. 1.083 above but capacity exc. 500 litre and n..exc. 1000 litre.
All as per Sl Item No. 1.084 above but capacity exc. 1000 litre and n..exc. 2000 litre.
Taking up or down steel tubing 15mm dia and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down steel tubing 20mm dia and connections including cleaning for refixing or removal to store complete all as specified and as directed.
CPVC pipes 20mm outer dia, SDR-11 and plain CPVC SDR-11 fittings fixed on walls, ceilings or laid in floors etc.,complete all as specified and as directed.
CPVC pipes 25mm outer dia, SDR-11 and plain CPVC SDR-11 fittings fixed on walls, ceilings or laid in floors etc.,complete all as specified and as directed.
Dismantling water tanks and removing to store (exc 250 and not exc 500 ltr capacity) complete all as specified and as directed.
Dismantling water tanks and removing to store (exc 500 and not exc 1000 ltr capacity) complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs capacity complete complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 1000 ltrs capacity complete all as specified and as directed.
20mm bore dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed in repairs complete all as specified and as directed.
PVC sintex tank covers of suitable size for existing water tanks fixed with bolts and screws as in repairs complete all as specified and as directed.
25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed both ends or for unions etc fixed in repairs complete all as specified and as directed.
Disconnecting existing water tanks, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (cleaning repairing etc. measured separately) capacity of tank in litres exc 250 and nexc. 500 complete all as specified and as directed.
Disconnecting existing water tanks, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (cleaning repairing etc. measured separately)capacity of tank in litres exc 500 and n.exc. 1000 complete all as specified and as directed.
Cleaning of inaccessable roof of buildings and removal of debris upto dust dumping yard/ low laying area of the MD land as directed by Engr-in-charge.
Demolition of cement concrete of any description and in any position and other wise specifically provided for and disposal of debris out side of MD land complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B-1 using 20mm graded stone aggregate as in floors, 40mm thick finished even and smooth with out using extra cement complete all as specified and as directed.
Rendering 10 mm thick in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and fair all as specified and as directed.
Roof treatment by applying bitumen primer @ 0.27kg/sqm, providing 3mm thick APP modified water proofing membrane weighing not less than 3.8 kg/sqm reinforced with non woven polyester matt weighing not less than 180gm/sqm, having softening point not less than 140 centigrade, having tensile strength of 650 N/sq.cm in longitudinal and transverse directions, the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap applying a coat of blown grade hot bitumen VG-10 over the membrane @ 1.2kg/sqm, top of membrane shall than be finished with solar reflective bituminous aluminium paint @0.10kg/sqm all as specified and as directed.
Preparation of old decorated surfaces and applying one coat of white wash on walls including in narrow widths/ bands etc complete all specified and as directed.
Preparation of old decorated surfaces and applying two coats of white wash on walls including in narrow widths/ bands etc complete all specified and as directed.
Preparation of old decorated surfaces and applying one coat of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed.
Preparation of old painted surface and applying one coat of synthetic enamel paint on steel and iron surfaces over 10cm width or girth all as specified and as directed.
Preparation of old painted surfaces and applying one coat of synthetic enamel paint on wood and wood based surfaces over 10cm width or girth all as specified and as directed.
Preparation of old decorated surfaces including washing, rubbing down and stopping and applying one coat of oil emulsion distemper on walls all as specified and directed.
Preparation of old decorated surfaces including washing, rubbing down and stopping and applying two coats of oil emulsion distemper on walls including necessary putty all as specified and directed.
Preparation of old decorated surfaces including washing, rubbing down and stopping and applying one coat of oil emulsion distemper on ceiling all as specified and directed.
Preparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, treating oil and greasy spots etc and applying one coat of cement base paint at any position all as specified and directed.
Preparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, treating oil and greasy spots etc and applying two coats of cement base paint at any position.
Preparation of old plastered surfaces of any description over 10cm girth or width and applying one coat of plastic emulsion paint of approved tint complete all as specified and as directed. MAKE : Royale luxury emulsion of Asian paint /silk luxury emulsion of Berger Paints / Satin stay bright of ICI Dulux
Complete removal of existing treatment on wall surfaces of any description including brooming down with steel wire brushing, scrapping down smoke soot's , moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) over a coat of weather proof primer including filling the cracks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed.
French polishing on old polished wooden surfaces of any description, width or girth exc 10cm including cleaning and preparing the surfaces with two or more coats including a coat of wood filler all as specified and as directed.
Preparation of new plastered surfaces and applying three coats of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed.
Part II (Internal Electrification works)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan,call bell socket or power circuits) including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., complete and making good the disturbed surface of walls, ceiling etc., including painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete concealed with 1.5 sq.mm single core PVC insulated unsheathed 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked including accessories concealed in walls including MS terminal boxes fabricated with 1.6 mm thick MS sheet, concealed on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for one light point controlled by one switch.
All as per Sl Item No. 2.002 here in before but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.002 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.002 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.002 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.002 here in before but for one 3 pin socket out let 5 Amps on same board.
Point wiring complete concealed for modular type switch & sockets with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concelaed type wiring includign GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 2.008 here in before but for one fan point controlled by one switch/regulator
All as per Sl Item No. 2.008 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.008 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.008 here in before but for one bell / buzzer point controlled by bell push.
All as per Sl Item No. 2.008 here in before but for one 3 pin socket out let 5 A on same board.
Point wiring complete surface type with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including PVC Casing & Caping ISI marked with accessories surface type wiring including 1.6 mm thick MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed one light point controlled by one switch.
All as per Sl Item No. 2.014 here in before but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.014 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.014 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.014 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.014 here in before but for one 3 pin socket out let 5 A on same board.
Point wiring concealed complete with 2.5 sq.mm single core PVC insulated unsheathed 1100 volts grade multi stranded FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium density ISI marked with accessories concealed type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet, concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring (modular) complete concealed with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete surface type with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and incl non-metalicPVC casing caping ISI marked with accessories concealed wiring incl GI/ MS branded sunken boxes of suitable moodule concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. NOTE FOR Sl ITEM NO. 2.002 to 2.022 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
LED batten suitable for indoor applications 18/20 Watts,4 feet with polycarbonate housing and integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No.830192 18W CDL/ Havells Cat No: LHEXAPP7IN1W020 / C&S Cat no: LTTB4F20W LED EW BATTEN complete all as specified and as directed.
LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No.830206 10W CDL/ Havells Cat No: LHEXACP5IN1W010 of Havells / C&S Cat No:LTTB2F 10WLEDW BATEN all as specified and as directed.
2' x 2' Recess mounted LED luminaire suitable for Gypsum/ grid type false ceiling of capacity 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings all as per Bajaj Cat No : BZRSQL 36W GZI WH / C& S Cat No. LTCRSLM36WATT2X2 or techno commercially equivalent makes specified in PS complete all as specified and as directed.
1' x 1' Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission arcylic cover complete with all accessories all including taking out old fittings all as per Bajaj, Cat No : BZSSQL 24W LED WHI or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Bulk head fittings of 10 watt, IP -65 type luminaries complete with all accessories including taking out old fittings all as per Bajaj Cat No: BIPWP 10 W LED of BAJAJ or or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Modular switch 1 way, 6 Amps, one module complete all as specified and as directed.
Modular switch 1 way 16 Amps, one module complete all as specified and as directed.
Modular switch 2 way, 6 Amps, one module complete all as specified and as directed.
Modular bell push, 1 way, 6 Amps, one module complete all as specified and as directed.
Modular socket, 6 Amps, 2/3 pin combined, two module complete all as specified and as directed.
Modular socket, 6 Amps / 16 Amps, 2/3 pin combined, two module complete all as specified and as directed.
Modular fan regulator, five stepped, 120 Watt, 2 Module complete all as specified and as directed.
Switch piano flush button single pole two way 5 Amps with ISI marked complete all as specified and as directed.
Angle holder PVC/polycarbonate type all as specified and as directed.
Switch Piano, flush type, 5 Amps, 240 Volts single pole with ISI marked complete all as specified and as directed.
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch all as specified and as directed.
Switch socket combination 2 in 1, 3 pin and 2 pin, 5 and 15 Amps flush type, universal complete all as specified and as directed
Socket outlet 2 in 1, 3 & 2 pin 5 Amps all as specified and as directed
Bell push flush type, one way 5 Amps all as specified and as directed.
MCB single pole and neutral 240 Volts, 40 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB single pole 240 Volts, 6 to 32 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB TPN 415 volts 32 to 63 Amps including taking down the existing complete as specified and as directed.
MCB DB SPN 4 way 240 volts, double door, with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
MCB DB SPN 8 way 240 volts, double door, with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
Stepped type electronic fan regulator flush switch type including taking down the existing complete as specified and as directed.
Ding dong bell AC 230 volts single pole including taking down the existing complete as specified and as directed.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 6 sq.mm, earth continuity conductor of size 6 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade concealed in walls/roof/floors complete all as directed. NOTE:- Two wires of 6 sq.mm and one wire of 6 sq.mm and one run of PVC conduit shall be measured as one unit.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 4 sq.mm, earth continuity conductor of size 4 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade concealed in walls/roof/floors complete all as directed. NOTE:- Two wires of 4 sq.mm and one wire of 4 sq.mm and one run of PVC conduit shall be measured as one unit.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing, heat resistant complete with driver, lamp bracket with impact and corrosion resistant, thermal management in multiple optics including taking out old fittings all asper Bajaj, Cat No.:- BREP 25 W LED WH C&S Cat No. LTESS36WlED/LS or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Brackets made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc., applying two coats of aluminum paint over a coat of red oxide primer before fixing including removing the old existing GI bracket from building complete all as specified and as directed.
Sheet metal enclosure single pole and neutral with a two pin earth plug and socket with one single pole MCB 32 Amps, 230 Volts AC complete all as specifeid and directed.
S S BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .