| Sl No | Description | Qty | Unit | M/S Ram Pravesh Singh L3 | M/S B D Enterprises L4 | M/S BHRIGU NATH SINGH L1 | M/s Maa Ugra Tara Construction L2 | JAGAT NARAYAN RAI L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. | 1,091.72 | CUM | 139.58 ₹1,52,382.84 | 300 ₹3,27,517.2 | 119 ₹1,29,915.16 Lowest | 220 ₹2,40,179.28 | 152.42 ₹1,66,400.57 |
| 2.00 | EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 871.66 | CUM | 50.82 ₹44,297.76 | 50.82 ₹44,297.76 | 43.52 ₹37,934.64 Lowest | 50 ₹43,583 | 55.5 ₹48,377.13 |
| 3.00 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode measurement compacted Volume). | 309.27 | CUM | 118.49 ₹36,645.4 | 118.49 ₹36,645.4 | 101.46 ₹31,378.53 Lowest | 150 ₹46,390.5 | 129.39 ₹40,016.45 |
| 4.00 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) | 208.26 | CUM | 415.58 ₹86,548.69 | 415.58 ₹86,548.69 | 355.86 ₹74,111.4 | 300 ₹62,478 Lowest | 453.81 ₹94,510.47 |
| 5.00 | Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge | 902.74 | SQM | 322.35 ₹2,90,998.24 | 322.35 ₹2,90,998.24 | 276.03 ₹2,49,183.32 Lowest | 300 ₹2,70,822 | 352.01 ₹3,17,773.51 |
| 6.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level:
1:2:4 (1 cement :2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size. | 89.55 | CUM | 4,465.38 ₹3,99,892.64 | 9,000 ₹8,05,986 | 3,823.7 ₹3,42,427.63 Lowest | 4,500 ₹4,02,993 | 4,876.19 ₹4,36,682.32 |
| 7.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- all work upto plinth level
1:1.5:3 (1 cement :1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size. | 213.75 | CUM | 5,094.36 ₹10,88,934.73 | 5,094.36 ₹10,88,934.73 | 4,362.3 ₹9,32,454.71 Lowest | 4,500 ₹9,61,888.5 | 5,563.04 ₹11,89,116.49 |
| 8.00 | Centering and shuttering including structting, Propping etc. and removal of form for:
Foundation, footings bases of columns , etc for mas concrete | 289.5 | SQM | 184.61 ₹53,444.6 | 184.61 ₹53,444.6 | 158.08 ₹45,764.16 Lowest | 170 ₹49,215 | 201.59 ₹58,360.31 |
| 9.00 | reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level, excluding the cost of centering, shuttering, finishinng and reinforcement:
1:1.5:3 (1 cement :1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size. | 92.98 | CUM | 5,891.97 ₹5,47,847.15 | 9,800 ₹9,11,223.6 | 5,045.29 ₹4,69,121.15 Lowest | 5,900 ₹5,48,593.8 | 6,434.03 ₹5,98,248.98 |
| 10.00 | Centering and shuttering including structting, Propping etc. and removal of form for :
Columns, Pillars,Piers,Abutments, Posts and Strusts | 731.9 | sqm | 436.56 ₹3,19,520.01 | 436.56 ₹3,19,520.01 | 373.83 ₹2,73,607.67 Lowest | 390 ₹2,85,442.56 | 476.72 ₹3,48,913.27 |
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
12 Jul 2022, 5:00 pmClosed
NODAL OFFICER
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Ranchi.
Construction of Ayush Drug Testing Laboratry in RCH Campus at Namkum, Ranchi District.
2022_JSBCC_59463_1
JSBCCL/36/2022-23
Open Tender
Civil Works - Buildings
Item Rate
330 days
Ranchi
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
Yes
JSBCCL
₹3.5 L
Yes
13 Oct 2022
20 Jun 2022
14 Jul 2022
20 Jun 2022
12 Jul 2022
20 Jun 2022
Amount
EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode measurement compacted Volume).
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 1:2:4 (1 cement :2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- all work upto plinth level 1:1.5:3 (1 cement :1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size.
Centering and shuttering including structting, Propping etc. and removal of form for: Foundation, footings bases of columns , etc for mas concrete
reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level, excluding the cost of centering, shuttering, finishinng and reinforcement: 1:1.5:3 (1 cement :1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size.
Centering and shuttering including structting, Propping etc. and removal of form for : Columns, Pillars,Piers,Abutments, Posts and Strusts
reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, chajja, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishinng and reinforcement: 1:1.5:3 (1 cement :1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size.
Centering and shuttering including structting, Propping etc. and removal of form for : Lintels, Beam, Plinth Bemas, Girders, bressumers and Cantilivers
Centering and shuttering including structting, Propping etc. and removal of form for : Stairs, (Excludings Landing) Excepts Spiral - staircases.
Centering and shuttering including structting, Propping etc. and removal of form for : Suspended Floors, Roofs, Landings, Balconies and access platform
Centering and shuttering including structting, Propping etc. and removal of form for : weather Shade, Chajjas, corbels etc. including edgess
Centering and shuttering including structting, Propping etc. and removal of form for : Shelves (cast in situ)
Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I.
Providing and laying damp-proof course 50mm thick with cement concrete 1:1.5:3 (1 cement :1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size.
Providing designation 75 B BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge.
Providing 125 mm thick REINFORCED DESIGNATION 75 A BRICK WORK in C.M. (1:4) in SUPERSTRUCTURE with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15 mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of Engineer Incharge .
Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 12 mm thick water proof CEMENT PLASTER (1:6)on outside wall with clean coarse sand of F.M.1.5 and 5% cico including cost of screening, curing making grooves with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I. (Cost of cico will be paid separately)
Providing tor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing including carriage of bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction and direction of E/I. (Only valid for TATA TISCON / SAIL).
TOR 8MMDIA. - 10 MM DIA.
TOR 12 MMDIA. - 32 MM DIA.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emul- sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1%concentration
Providing & fixing FAN HOOK of 16 mm dia M.S. bar, 1 M long bent to required size and shape, placed in position and fluid in the R.C.C. slab-beam at the time of casting all complete as per building specification and direction of E/I
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
Providing and laying VITRIFIED TILES in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades in skirting and over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. (Approved brand - Kajaria/ Asian/ Somany)
Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying 25mm thick white makrana marble tiles in risers of steps, skirting and pillar of approved quality over 12mm thick base of cement mortar (1:3) and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building speicification and direction of E/I.
Providing and fixinging 20 mm thick mirror polished, machine cut for kitchen platform and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 (1cement :4 coarse sand) laid and jointed with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade
Providing and laying 25mm thick white makrana marble stone slab flooring of approved quality over 19mm thick base of lime mortar (1:1:1) (Lime putty : surkhi : coarse sand) laid and jointed with white cement slurry including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building speicification and direction of E/I.
Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and1.8 cm thick fixed in Urinal Partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4(1cement :2 coarse sand : 4 stone chips)as per direction of E/I and finished smooth.
Supplying, fitting & fixing 35 mm th. Solid core type non-decorative single leaf FLUSH DOOR SHUTTERS in doors with block board core blended with high quality phenol formal dehydes synthetic resinboth side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts , handle,cleats aldrop, door stopper & sand blocks & taxes all complete as per detail drawing building specification & direction of the E/I.
suppling , fitting and fixing good quality well dressed and well seasoned sal wood work in chaukhat in doors window ,sky light ,fanlight and celevitial window opening including wedge over clmps all including application of two coats of wood preservative of approved quality on the surface , building walls and lintel all complete as per building specification and direction of El.
Providing and fixing factory made P.V.C. door frame manufactured by M/s Rajshri or equivalent of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers speci fication and direction of Engineer-in-Charge.-
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S.frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mmthick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. 30 mm thick pre laminated PVC door shutters
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i. e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium window, ventilator shutters etc. with EPDM / Neoprene gasket etc complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I. Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth copmlete .
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I
Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives "Snowcryl - XT" of M/S Snowcem India Ltd, or equivalent of required shade. New work (Two or more coats applied @1.43 ltr / 10sqm. Over and including base coat of water proofing cement paint Snowcem Plus or equivalent applied @ 2.20 kg./10 sq.m.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete.
Providing two coats of SYNTHETIC ENAMEL PAINT of approved shade and make over new WOODEN surface including cleaning the surface after removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification dirction of E/I.
Providing primer one coat of approved shade and make over new wooden surface including preparing the surface after cleaning, removing dirt, scales, smokes, grease and sand preparing, including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio).
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners, etc.)
Providing & fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
Providing & fixing on wall face unplasticised -P.V.C. moulde fittings / accessories for unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion .
Coupler 110mm
110mm Single tee without door
110 mm Plain Tee
Shoe 110mm
Providing 250 mm wide brick drain in cement mortar (1: 6) with av. 150 mm. clean depth and 250 mm apron including cost of earthwork involved with 75 mm, cement concrete (1: 4: 3) over one brick designation 75A, flat soling in proper grade and slope at the base, the drain duly plastered in C.M (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
CARRAIGE OF MATERIALS
Bricks (1K+ 7P = 8 KM.)
SAND , LEAD - 20 KM.
STONE CHIPS - 22 KM.
Filling Sand lead = 1km
Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. Group - C
Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required.
Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
2x2.5 sq mm+1x2.5 sq mm earth wire
2x10 sq mm+2x6 sq mm earth wire
4x10 sq mm+2x10 sq mm earth wire
4x16 sq mm+2x16 sq mm earth wire
Teliphone wiring existing conduit:- Supplying and drawing following pair 0.5 sq mmFR PVC insuleted copper conductor, unaramed teliphone cable in existing recessed PVC conduit as required 2 Pair
S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required . 25mm
S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
5/6 amps, one way switch
5/6 amps, 3 pin socket outlet
Teliphone socket with shutter outlet
S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. 1 or 2 module(78mm x 78mm x 45mm)
S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required.
S/F ceiling rose:- Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
S/F Batten holder:- Supplying and fixing batten/angle holder including connection etc, as required.
S/F Dingdong Call bell :- Supplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required.
ITC exhaust fan up to 450 mm, sweep:- Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.
S/F MCCB in cubical panel board:- Providing and fixing following rating and capacity four pole MCCB in existing panel bord,including drilling holes in cubical panel making connections etc as required. 100 amps, 16 KA fixed thermal seting
S/F Sheet metal ON/OFF-Load chenge over:- Providing and fixing following capacity 2 pole/ 4 pole ON/OFF-Load chenge over switches with side handle opreation, in sheet inclosure in existing panel board including drilling holes in metal board, making connection, earthing the body etc as required 100 amps, 4 pole
S/F VERTICAL TYPE T.P.MCB DB:- Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) Note:- Vertical type MCB TPDB is normally used where three phase outlets are required. 4 way (4+24),Double door, Vertical type
S/F S.P.MCB DB:- Supplying and fixing following way, Single pole and nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) 8way SPN MCB DB DOUBLE DOOR
S/F T.P.MCB DB:- Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) 4 way (4+12),Double door, Horizontal type
S/F 'B' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. 6/32 amps,single pole, "B" SERIES
S/F 'C' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
6/32 amps,single pole
40 amp DP MCB
40 amps,TPN (TO BE FIX IN VTPN DB)
40 amps,TPN (TO BE FIX IN TPN MCB DB)
P/F M.V. danger notice plate:- Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required.
G.I Earth pipe electrode with salt charcoal :- Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
Providing and fixing 25x5mm GI Strip
S/L 8 SWG copper wire ground :- Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
MV cable laying upto 95 sq.mm. in Wall Surface:- Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 95 sq.mm. on wall surface
MV cable laying upto 95 sq.mm. in ground:- Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 35 sq.mm. but not exceeding 95 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
S/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:1554, part-1)
50sq.mm. 3.5 core
Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Providing of 1200 mm sweep A.C ceiling fan
Providing & fixing of holder type LED -15 watt lamp
Providing of 300 mm sweep A.C Exhaust fan
Providing of surface mounted 15 /16 WATT LED Round downlighter
Providing of LED flood light 120 W
LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMING (1- sets ) each with following:
150 Amp, MCCB FP -01no, Ammeter, ASS, CTs, Voltmeter, VSS, Fuses, 1 Sets of Phase Indicating Lights with fuses , 250A changover FP (ON-LOAD)-1nos.& following accessories: -
BUS BARS
1 sets of 200 Amp, 415V, 3 phase, 50 Hz TPN copper bus bars.
OUTGOING
a)12 Nos of 32 Amp SPN MCB,
b)2Nos of 32 Amp TPN MCB,
c)3Nos of 50/ 63 Amp TPN MCB,
LT Panel (Normal) as above
150A MCCB FP
150A changover FP (ON-LOAD)
200 Amp, 415V, 3 phase, 50 Hz TPN copper bus bars.
32 amps.SPN MCB
32 amps.TPN MCB
63 amps. TPN MCB
DIGITAL VOLT METER 500V(3phase class 0.5)
DIGITAL A METER 500V(3phase class 0.5)
1.5 sq mm ISI marked FRLS PVC insulated single core copper conductor cable
6 sq mm ISI marked FRLS PVC insulated single core copper conductor cable
10sq mm ISI marked FRLS PVC insulated single core copper conductor cable
LED INDICATOR LAMP R/Y/B/G
CT coil of CT tatio 200/5 IS 2705 part 3
S/F wall floor mounted cubical panel board , fabricated with 14 gauge iron sheet suitable for panel mounted switch disconnector ,incliding busbar chamber,insulator and painting etc.as required .(but without busbar copper strip)
Panel Commissioning / Testing Charges and overhead charges 20%
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., "p" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l.
Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l .
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With "P" trap (a)12.5 lit. low level P.V.C cistern
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 gms
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.
25 mm nominal bore
40 mm nominal bore
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l.
125 mm nominal dia with 25 mm waste hole
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Single tee with door
110 mm bend
Coupler
110mm Place trape
Providing and fixing on wall face unplasticised Rigid PVC waste water and soil pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion, (I) Single socketed pipes. 12.41.1 75 mm diameter
Single tee with door75 mm
Bend 87.5° 75 mm
Shoe (Plain) 75 mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete75 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Providing and fixing C.P. brass swan neck sink cock for kitchen sink of approved quality 15mm nominal bore, approved brand C.P. fittings.
Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible Pipe
Provding and laying of 110mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.(SUPREME S.W.R.)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of two half stall urinals with 5 litre P.V.C. automatic : flushing cistern
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation and refilling all complete as per specification and direction of E/l.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 1:2:4 (1 cement :2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size.
Providing designation 75 A brick work in C.M. (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l.
Supplying & Fixing C.I. Cover without frame -do-do- all complete job 455mm x 610 mm Rectangular
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm Square Bar
Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm Dia
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation and refilling all complete as per specification and direction of E/l.
Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design building specification and direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 1:3:6 (1 cement :3 coarse sand (zone-III) : 6 graded stone aggregate 40 mm nominal size.
Providing tuck pointing [1:3] in cement on brick work clean coarse sand of F.M 1.5 FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 12mm cement plaster(1:3) with clean course sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing taxes and royalty all complete as per building specification and direction of E/I.
Supplying, assembling, lowering and fixing in vertical position in borewell unplasticized PVC medium well screen (RMS) pipes with ribs, confirming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of engineer-in-charge. 100 mm nominal size dia
Supplying,filling, spreading and levelling stone boulders of of size range 5cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.
Supplying,filling, spreading and levelling gravels of size range, 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
HYDT: Cost of Drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in Rural) area for Installation of pump set with Hydraulic DTH Ring machine, all complete including supplying all materials, tools, drilling, rig, Air Compressor and Equipments, as well as fuel, lubricants and cost of Transportation of Rig Machine and other Vehicle up to site.
From 0.0M to 50.0 M
From 51 M to 125.00 M
Supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6 mm wall thickness including welding charges, cost of Pipe etc. including all taxes, VAT, Excise duty, Fright charges with inspection charges etc. as applicable, etc. all complete Jobs.
Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Supplying all materials, labours, tools & equipments for fitting & fixing 200 mm dia M.S.Cap over Casing Pipe including all taxes, VAT, Excise duty, Fright charges with inspection charges etc. as applicable, etc. all complite Jobs.
Supplying 100 mm dia Submersible Pump Set Conforming to IS : 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and Polypropylene / Noryl impeller. Motor suitable for working on 415V+10%, 3PH, 50Hz, A.C. Supply with cable guard, thurst carbon / fiber bearing to with stand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall be suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single / double run shall be provided with each pump.
Submersible Pump set 100 mm dia ( with Polypropylene / Noryl impeller ) up to 20 stages. 2 HP
G.I.FITTINGS ( CONFORMING TO I.S. - 1979 (K) G.I. PIPES ( TATA MARK ) OR EQUIVALENT 40 mm Dia
Providing P.C.C/R.C.C. M-200with normal mix of (1:1.5:3) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in cement mixer and placing in position, vibrating, skirting, curing, tax and royalty all completejob as per building specification and direction of Engineer-in-charge.
Providing designation 75B one brick on edge soiling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Supplying fitting and fixing G.W.I wire mesh jali (2'-0"x2'-0") in position as per specification and direction of E/I.
Supplying complete pannel borard with all accessories (starter 1 no, volt meter 1 no, amp meter 1 no. 10amp kit kat) (male & female) all complete job.
Cost of 4 mm 2 flat copper cable 70.00 finolex make for lowering the pump & connection upto pannel bord with all complete job.
Add 18% GST
Add 1% Labour cess 1%
M/s Maa Ugra Tara Construction
M/S Ram Pravesh Singh
M/S B D Enterprises
JAGAT NARAYAN RAI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .