Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.5 L+₹1.9 L (9.46%)Rejected-Finance | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹22.6 L+₹2.1 L (10.2%)Rejected-Finance | L3 | Rejected-Finance Not being lowest bidder | |
| 4 | L4₹23.4 L+₹2.8 L (13.9%)Rejected-Finance NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L4 | Rejected-Finance Not being lowest bidder | |
| 5 | L5₹27.9 L+₹7.4 L (35.9%)Rejected-Finance | L5 | Rejected-Finance Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
24 Jul 2021, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/REPLACEMENT OF INSTALLATION GATE LIGHT, INTERNAL WIRING, LIGHT FITTINGS, SECURITY LIGHTS AND OTHER RELATED WORKS AT VARIOUS PUMP HOUSE UNDER GE E/M LUCKNOW
2021_MES_455214_1
GE/EM/LKO/EXT(WS)/T-29 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Class D or above category b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹90,000
Yes
6 Aug 2021
28 Jun 2021
26 Jul 2021
28 Jun 2021
24 Jul 2021
12 Jul 2021
Amount
Repair/maint of LT Panel 3 phase AC 415V, 50 Hz A of any make including Taking out old /UNSV MCCBs & MCBs /incoming and outgoing laminated copper busbar , DMC/epoxy insulators of any size ,Volt meter, Amp. meter,phase indicator LED lamp,Change over switch of any capacity ,burnt out copper winding ,current coil ,potential coil and keeping aside for safe custody for re-use, opening the L.T. Panel, removing gasket, dismantling and taking out old parts carefully, disconnecting all conections, & re-assembling all serviceable parts to original position including cleaning , removing sludge, dirt, dust, cleaning of parts including removal of old paint with 02 coat synthetic enamel paint after 01 coat iron red oxide paint along with replacement of nuts, bolts, thimbles, gasket etc as per site requirement including complete testing as per site requirement. , complete all as specified and directed by Engineer-in- Charge. Note : All spare parts and rewiring work will be measured and paid seperately under respective item of Sch 'A'.
Supply only MCCB 160 Amps, 415 volts AC 50Hz, 3 pole, bracking capacity 36 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified and directed by Engineer-in- Charge
Supply only MCCB 200 Amps, 415 volts AC 50Hz, 4 pole, bracking capacity 36 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified and directed by Engineer-in- Charge
S & F in repairs MCCB 100 Amps, 415 volts AC 50Hz, 3 pole, bracking capacity 16 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified and directed by Engineer-in- Charge
S&F distribution box epoxy powder coated ,SPN 8 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed by Engineer-in- Charge
S&F distribution box epoxy powder coated ,SPN 4 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed by Engineer-in- Charge
S&F distribution box epoxy powder coated ,TPN 4 way, 440 V, with 200 amps rated bus bar, 440 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed by Engineer-in- Charge
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 32 amps , complete all as specified and directed by Engineer-in- Charge
Supply & fix in repair MCB TPN capacity 32 Amps, 415V, 50 c/s 16 KA, complete all as specified and directed by Engineer-in- Charge
Supply & fix in repair MCB SPN capacity 32 amp, 'C' series , complete all as specified and directed by Engineer-in- Charge
MCB SP 6 to 32 Amps, 240 Volts of 'B' series to be housed in DBs and suitable size cable lugs to be fixed with MCBs as in replacement, complete all as specified and directed by Engineer-in- Charge
Supply only Set of indicating lamp LED type, complete all as specified and directed by Engineer-in- Charge.
S&F in repairs electronic control timer type ET-100 of suitable capacity as required at site complete all as specified and directed by Engineer-in- Charge. Make : L&T/ABB/Legrand/AE
S&F in repairs under voltage relay, complete all as specified and directed by Engineer-in- Charge Make : PIC/EC/Wader
S&F in repairs 8/11 pin relay, complete all as specified and directed by Engineer-in- ChargeMake : PLA
S&F in repairs crocodile clip for battery chargers of required size complete all as specified and directed by Engineer-in- Charge
S&F In repairs three pole power contactor type MNX-185,complete all as specified and directed by Engineer-in- Charge Make : L&T
S&F In repairs four pole power contactor type ML-06, complete all as specified and directed by Engineer-in- Charge Make : L&T
Single phase preventor relay + timer 415 volt, complete all as specified and directed by Engineer-in- Charge Make : L&T
DIN type fuse link type HN suitable for upto 200 Amps, complete all as specified and directed by Engineer-in- Charge Make : L&T
Push button pendant 6 Amps, 415V, 50Hz with 02 push button complete all as specified and directed by Engineer-in- Charge Make : L&T
M & L Point wiring for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surface as existing same colour including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing including taking down old unserviceable point wiring, complete all as specified and directed by Engineer-in- Charge
All as per item No 25 above but for one socket outlet point 5 amps on independent board controlled by one, one way switch.
All as per item No 25 above but for one socket outlet point on the same baord with other switches.
M & L Point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and1.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing including taking down old unserviceable point wiring, complete all as specified and directed by Engineer-in- Charge
Sub main wiring (concealed type ) with two single core 6 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface in and including taking down old unservicable sub main wiring , complete all as specified and directed by Engineer-in- Charge Note : (i) 2 run of 6 Sqmm ,1 run of PVC conduit & 1 run of 4 Sqmm cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Sub main wiring (concealed type ) with two single core 4 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 2.5 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface in and including taking down old unservicable sub main wiring , complete all as specified and directed by Engineer-in- Charge Note : (i) 2 run of 4 Sqmm ,1 run of PVC conduit & 1 run of 2.5 Sqmm cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
S & F Switch piano flush type of sigle pole ,5/6 Amps, one way ,complete all as specified and directed by Engineer-in- Charge
S&F Switch piano flush type of single pole, 15 Amps, one way ,complete all as specified and directed by Engineer-in- Charge
S&F Socket out let 2 in 1 socket 3 pin 5 Amps, flush type controlled by one switch , complete all as specified and directed by Engineer-in- Charge..
Socket out let 2 in 1, 3 pin, 5 and 15 Amps flush type , complete all as specified and as directed by Engineer-in- Charge.
Ceiling rose, Pilot 3 Plate ceiling rose 6A ,complete all as specified and as directed by Engineer-in- Charge.
S&F Lamp Holder PVC/ polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in- Charge..
S&F in replacement LED bulb 14 watt complete all as specified and directed by Engineer-in- Charge, Make : Bajaj/Wipro/CG/Surya
Fixing only Gate light LED-40 WATT 215 V, 50 HZ, post top made in cast aluminium spigot housing with decorative clear acrylic diffuser and IP65 protection fix with GI Pipe 40 mm dia 30 cm long (15 cm under the pillar & 15 cm above the pillar ) with proper connecting with existing electric cable in and including taking out old unservicable light , complete all as specified and directed by Engineer-in- Charge. Note :- Gate light will be issued under Sch 'B'
Flourescent LED tube light fitting Surface mounting , 1X36 Watt ,energy efficient,ceiling /wall mounting box type fitting complete , with decorative serrated acrylic cover diffused illumination elegantly designed , spring loaded, rotary type lamp holder, connector block etc. and all accessories with 1 No 40/36 watt tube rod including provn of two core flexible copper cable of size 1.5 Sqmm from ceiling rose/connector in and including taking out old unservicable light , complete all as specified and directed by Engineer-in- Charge.
S&F PVC insulated & sheathed , heavy duty electric cable on RCC Piller /Dome of over head tank at hight of 26 meter approximatelly from normal ground level including fixing arrangement with Copper conductor, multi stranded 1100 volts grade flate 3 core 04 Sqmm and taking out of existing unserviceable cable complete all as specified and directed by Engineer-in- Charge.
Laying, fixing and testing only LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core laid in trenches/ under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing complete and taking out unserviceable cable, complete all as specified and directed by Engineer-in- Charge. Notes: 1. Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items. 2. Cable will be issued under Sch 'B'
All as per Item No 41 above but 25 Sqmm 3.5 core.
All as per Item No 41 above but 50 Sqmm 3.5 core.
All as per Item No 41 above but 70 Sqmm 3.5 core.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-charge.
Removing excavated material not exc 50 m and depositing where directed at a level not exc .5m above the starting point complete all as specified and directed by Engineer-in-charge.
Supply and spread fine dry sand locally available for cable cushioning complete all as specified and directed by Engineer-in-charge.
M&L for laying sub class 'B' brick in trenches as cable protection covers across the length of the cable complete all as specified and directed by Engineer-in-charge.
Supply & fixing on load Changeover switch in open execution 4 pole 415 V, 50 cycles-160 Amp complete all as specified and directed by Engineer-in-charge.
Supply & Fixing LED street/bldg light fitting luminaire 70 Watt IP65, 230 volts, new generation energy saving & enviormental friendly long life versatile pressure die cast aluminium roadway luminarie with high power LEDs as light source and electronic driver alongwith suitable bracket required as per site for fixing the light complete all as specified and directed by Engineer-in-charge.
Fixing only of star delta starter fully automatic oil cooled with auto transformer and first filling of transformer oil complete with suitable size cable for connection between starter to auto transformer suitable for 7.5 to 15 HP, 3 Phase, 415 V electric motor including necessary connection and fixed on stand made out of angle iron 40 X 40 X 4 mm size including dismantling and taking out old star delta starter , complete all as specified and directed by Engineer-in-charge. Note :- Star delta will be issued under Sch 'B'
Supply and fixing of star delta starter fully automatic oil cooled with auto transformer and first filling of transformer oil complete with suitable size cable for connection between starter to auto transformer suitable for 30 to 50 HP, 3 Phase, 415 V electric motor including necessary connection and fixed on stand made out of angle iron 40 X 40 X 4 mm size including dismantling and taking out old star delta starter , complete all as specified and directed by Engineer-in-charge.
Supply, installation, testing, commissioning & electrically connected feeder pillar outdoor type, single door compartmentized with locking arrangement canopy at top weather proof, vermin/dust proof of suitable size cubical type factory made of CRCA MS sheet 3.15 mm thick machine pressed of size 60x60x40 cm & angle iron frame 40x40x6 mm for legs and including grouted in PCC 1:2:4 type B1 (20 mm graded stone aggregate) suitable 440 volts AC 3 phase 4 wire bus bar 4 pole made out of suitable size copper strip capacity 200 Amps fully mounted on procelain insulator enclosed chamber with open able shutter both sides comprising with including taking out old Feeder pillar , complete all as specified and directed by Engineer-in-charge.
M&L for earthing complete for electrical equipments with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to earth lead of GI strip of size 32x6mm by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soilcomplete all other accessories as shown on electrical plate No 3 of MES SSR Part I including 40mm bore light grade GI pipe 1.8 mtr length with top end covered with plug or cap for watering and 30x30x30cm size PCC 1:3:6 block around watering pipe, excluding 20mm dia watering pipe, PCC, watering pit, funnel, pit cover complete all as specified and directed by Engineer-in-charge.
M&L for earthing complete for electrical equipments with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00mm by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soilcomplete all other accessories as shown on electrical plate No 3 of MES SSR Part I including 40mm bore light grade GI pipe 1.8 mtr length with top end covered with plug or cap for watering and 30x30x30cm size PCC 1:3:6 block around watering pipe, excluding 20mm dia watering pipe, PCC, watering pit, funnel, pit cover complete all as specified and directed by Engineer-in-charge.
Collecting sample of water in sample bottle and Testing of water samples of 1 bore wells located in different pockets of cantonment area Lucknow required to be tested for chemical and bacteriological. Necessary action may please be taken to get it tested from state public health laboratory or NABL Accredited Lab and to be tested as per IS 10500, complete all as specified and directed by Engineer-in-charge.
M/S AMARJIT SINGH
M/S Nav Jyoti Enterprises
NEXT POWER ENTERPRISES
Shree Kanth Technologies
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .