Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC PO CHANDL PS BISHNUPUR DIST SOUTH 24 PGS PIN 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹52.1 L+₹6.2 L (13.5%)Rejected-Finance TIORKHALI MAHESHGANJ NADIA | NADIA | NADIA | WEST BENGAL | 790804 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹52.2 L+₹6.3 L (13.6%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹53.0 L+₹7.1 L (15.5%)Rejected-Finance 8 28 BIJOYGARH P O JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹54.8 L+₹8.9 L (19.4%)Rejected-Finance 38 BAGUIATI ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Oct 2022, 6:00 pmClosed
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ REPLACEMENT OF JOINERY, WALL PANELLING, FLASE CEILING INCLUDING SURFACE FINISHES AND OTHER MISC WORKS TO VARIOUS TECHNICAL BUILDING/ ADM BUILDING INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2022_MES_555170_1
8908/FW/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹80,000
21 Nov 2022
29 Sept 2022
28 Oct 2022
29 Sept 2022
27 Oct 2022
13 Oct 2022
Amount
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area not exc. 1.5 Sqm each and removing from the site all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm but not exc. 4.00 Sqm each and removing from the site all as specified and directed.
Taking down Shutters of any description not exc 1.00 sqm each and removing from the site all as specified and directed.
Taking down Shutters of any description exc 1.00 sqm but not exc 2.00 Sqm each and removing from the site all as specified and directed.
Taking down Shutters of any description exc 2.00 Sqm each and removing from the site all as specified and directed.
Supply and fixing 2nd class hard wood plain solid straight chowkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F factory made 35 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. with edges of sash bars and framing moulded plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR PartI, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
all as per item No. 7.00 but 30 mm thick for window/vantilators etc, are provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b)
all as per item No. 7.00 but 30 mm thick for window/vantilators etc, are provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b) without sash bars
S&F 2nd class hardwood factory made 35 mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Supply & fixing factory made 35 mm thick 2nd class hard wood panelled shutters (any Nos of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density wood particle board with commercial face veneers, fitted to chowkhats complete all as specified and directed.
M&L 30 mm thick flush shutters solid core construction with black board core and plywood face panels commercial type on both side complete all as specified and as directed.
Providing and fixing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S&F Factory made solid PVC door frame (chowkhat) of size 50mm x 47mm made out of 5mm plain colour wood grain PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced with MS square tube, S&F in opening as per specification & drg as per manufacturer instructions complete all as specified and directed.
M&L for Factory made solid PVC moulded door shutter, 28 to 30 m thick(stiles) with 2,4 or 6 raised panel design with 2 mm thick moulded prelaminated PVC sheet on the front face & 2 mm plain colour prelaminated PVC sheet on back face with particle board core complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
Supply and fixing rectangular and curved factory made uPVC fixed windows with frame dimension of 58mm x 52mm x 33mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2mm . The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should have extrusion facility in India and the windows to be assembled and installed by an authorised local fabrication partner . The windows must be installed complete with all kinds of iron mongery in Ist quality (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside and Outside of Dowcorning / GE or equivalent. The profiles have a warranty of 20 years. The profiles shall conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and also scaffolding if required for fixing is deemed to include in the rate quoted complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.)
S&F factory made uPVC- Sliding windows/doors having three tracks and three sashes (shutters) with frame dimension of 104mm x 49mm and sash dimension of 61mm x 47mm x 37mm each with middle sash fixed ,fixing of powder coated grill with and including upvc beading of required size, with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of iron mongery in 1st quality (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside and Outside of Dowcorning / GE or equivalent. The profiles having a warranty of 20 years. The profiles shall conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and cost of scaffolding if required for fixing shall deemed to be included in the quoted rate complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and poweder coated aluminium grill and includes all other connected accessories. Net opening will be measured for payment purpose.Glass and poweder coated aluminium grill will be measured and paid separately under respective items)
S&F factory made uPVC- Sliding windows/doors having two tracks and two sashes (shutters) with frame dimension of 58mm x 49mm and sash dimension of 61mm x 47mm x 37mm with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm.The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards.The profile manufacturer shall have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of iron mongery in Ist quality (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. The profiles shall have a warranty of 20 years. The profiles shall conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and cost of scaffolding if required for fixing shall deemed to be included in the quoted rate complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.)
S&F in repair Steel windows or ventilators, fixed type, with glazing barsincluding necessary scaffolding of any height complete all as specified and directed. (NOTE: Sheet glass will be measured and paid seperately)
S&F in repair steel window with side hung shutter including necessary hinges with steel handle and steel peg stay complete with glazing bars devotailed or welded including necessary scaffolding of any height complete all as specified and directed. (NOTE: Sheet glass will be measured and paid seperately)
S&F 100mm butt hinges stainless steel medium weight complete all as specified and directed.
All as per item No. 22.00 here-in-before, but 75mm.
S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
All as per item No. 24.00 here-in-before, but 200mm long all as directed complete all as specified and directed.
S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as directed complete all as specified and directed.
S&F aluminium handle, cast type anodised 125mm size complete all as specified and directed.
All as per item No. 27.00 here-in-before, but 150mm.
S&F stainless steel butt hinges of 100mm size complete all as specified and directed. (Make: Prayag Cat No. HG2414 or equivalent make as approved by GE).
S&F stainless steel handles of 150 mm size complete all as specified and directed. (Make: Prayag Cat No. DHL2150 or equivalent make as approved by GE).
S&F stainless steel handles of 200 mm size complete all as specified and directed. (Make: Prayag Cat No. DHL2200 or equivalent make as approved by GE).
S&F stainless steel tower bolt of 150 mm size complete all as specified and directed. (Make: Prayag Cat No. TBR 2150 or equivalent make as approved by GE).
S&F stainless steel tower bolt of 200 mm size complete all as specified and directed. (Make: Prayag Cat No. TBR 2200 or equivalent make as approved by GE).
S&F stainless steel Aldrop bolt of 200 mm size complete all as specified and directed. (Make: Prayag Cat No. LD-1208 or equivalent make as approved by GE).
S&F stainless steel Aldrop bolt of 300 mm size complete all as specified and directed. (Make: Prayag Cat No. LD-1212 or equivalent make as approved by GE).
S&F 75mm length hasp and staplemild steel, wire type, stove enemalled balck, including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F in repair Floor door stopper of brass body and tongue, anodised with hard drawn steel spring (overall length of cover plate 150mm) complete all as specified and directed.
S&F in repair Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring (overall length of cover plate 150mm) complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating, pipes, including bolts, if required hooks(stays) heavy for large gates hook and pintle hinges large hasps and staples, chains hand made sliding bolts, clamps, hold fasts, plain angle cleats for securing purlins to wood trusses or rafters knee piece inserts two way and three way straps plate washers and similar small articles conforming to fe-290 Gde E-165 complete all as specified and directed.
Cutting holes in to brick wall for inserting bold fast & making good dismantled portion in cm (1:3) or PCC (1:2:4) type B1, depth exceeding half brick but not exceeding 1 brick complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.00mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.00mm and fixed with stainless steel wire staplescomplete all as specified and directed.
M&L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and directed.
M&L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works with one or more coats complete all as specified and directed.
Taking down, easing and adjusting aluminum shutters/partitions including rubber neoprene packing complete of any description n.exc 1 sqm each and refixing in same opening, all as specified and as directed. (Note :- Replacement of door closer, glass, lock, handle, tower bolt etc shall be measured and paid separately)
-ditto- all as per item no. 45.00 but shutter/partition of area exc 1.00 sqm but not exc 2.00 sqm each
Taking down aluminium frames with shutters of any description area not exc. 1.5 Sqm each and removing from the site all as specified and directed.
Taking down aluminium frames with shutters of any description area exc. 1.5 Sqm but not exc 2.00 sqm each and removing from the site all as specified and directed.
Taking down aluminium Shutters of any description exc 1.00 sqm but not exc 2.00 Sqm each and removing from the site all as specified and directed.
S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F powder coated (medium thickness of powder coating 50 micron) aluminium frame for door, windows, partitions and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F anodised aluminium doors shutters, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips rubber packing handle 2 Nos in each door, hinges, Mortise lock vertical type size 100 mm 4 levers of brass in each door, anodised aluminium snap beading screws etc as per manufactures instruction complete all as specified and directed. (NOTE: Quoted rate is deemed to be inclusive of the cost of include for anodised aluminium hard ware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames, handle, mortise lock etc as described in item. Sheet glass shall be measured seperately)
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium doors shutters, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips rubber neoprene packing, handles 2 Nos in each door, hinges, Mortice lock vertical type size 100 mm 4 levers of brass in each door, anodised aluminium snap beading screws etc as per manufactures instruction complete all as specified. (NOTE:: Quoted rate is deemed to be inclusive of the cost of include for anodised aluminium hard ware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames, handle, mortise lock etc as described in item. Sheet glass shall be measured seperately)
M&L for anodised aluminium window and ventilator shutters, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinges types B-21 100 mm long (2No) suitable handle (1No) complete all as specified. (NOTE: Quoted rate is deemed to be inclusive of the cost of include for anodised aluminium hard ware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames, handle, mortise lock etc as described in item. Sheet glass shall be measured seperately)
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, anodised aluminum fittings such as suitable 150 mm long peg stays (01 No), hinges type B-21 100 mm long (02 Nos), suitable handle-01No each shutter etc as per manufactures instruction complete all as specified and directed. (NOTE: Quoted rate is deemed to be inclusive of the cost of include for anodised aluminium hard ware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames, handle etc as described in item. Sheet glass shall be measured seperately)
S&F in repair anodised aluminium grill (anodised transparent or dyed to required IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard design/pattern, with approved standard section and fixed to the existing window frame with chromium plated brass screws/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as per requirement and as specified and directed.
S&F in repair Aluminium body (extruded section) door closer hydraulically regulated, designation No 3, universal type suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg complete all as specified and directed. (Make : Godrej, Cat No. 1938 or equivalent make as approved by GE).
S&F in repair for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass, other part made of mild steel heavy duty complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, steel window or stone concrete or brick surrounds glazed with putty or fixed with beads complete all as specified and directed.
S&F Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 4.8mm thick plain sheet glass, ordinary quality, frosted on one side, area in squares exc 0.5 sqm in each pane and glazing in aluminium framework/ snap beading complete all as specified and directed.
-ditto- all as per item no. 61.00 but 4.8 mm thik sheet glass, frosted on one side
S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
S&F in repair 5mm thick toughened glass, fixed in hinged doors, partitions, automatic doors and similar works including cutting to shape, drilling holes required, alongwith decorative brass handles complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 12mm thick toughened glass, fixed in hinged doors, partitions, automatic doors and similar works including cutting to shape, drilling holes required, alongwith decorative brass handles complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work all as specified and as directed.
S&F in repair 12mm thick plywood grade BWR type B-B fixed with screws to timber frame works complete all as specified and directed.
S&F in repair 6mm thick plywood grade BWR type B-B fixed with screws to timber frame works complete all as specified and directed.
S&F in repair 19mm thick commercial faced plywood grade BWR type B-B fixed with screws to timber frame work as in pelmet boxes, cup board etc complete all as specified and directed.
M&L in repairs 0.9mm thick decorative laminate type-1 of surface finish colour and pattern as approved fixed with approved adhesive as per manufacturer's instruction complete all as specified and directed.
S&F in repair 6 lever brass type Mortice lock vertical type size 100mm complete all as specified and directed. (Make : Godrej Model No. 8194 or equivalent make as approved by GE).
S&F in repair Ultra Mortice lock with Universal brass (2H) Handle set, size 200mm complete all as specified and directed. (Make : Godrej Model No. 7660 or equivalent make as approved by GE).
S&F in repairs Chromium Plated 25mm dia brass chromium plated curtain rod with fixing brackets, stops, rollers etc complete all as specified and directed.
S&F in repairs fancy type metal finish curtain bracket fixed to walls complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets
M&L for snap grid system with powder coated aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and powder coated aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with supporting 6 mm dia. G.I hangers (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. (NOTE: Ceiling board shall be measured seperately)
Re-fixing of aluminium snap grid sytem using serviceable grid sections obtained from taking down of false ceiling, fixed to ceiling with supporting 6 mm dia. G.I hangers (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. (NOTE: Ceiling board shall be measured seperately)
S&F 'E' board "Classic", reinforced, designer series, ceiling board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium snap grid system complete all as specified and as directed.
M&L for applying two coats of oil bound distemper on new ceiling boards complete all as specified and directed.
Supply and Fixing PVC solid wall lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturer’s specification and instruction and as directed.
Supply and Fixing 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
S&F 5 mm thick PVC decorative beading, moulded/ designed for PVC wall panneling inclusinve of fixing complete all as specified and directed.
Dismantling of Asbestos cement corrugated, semi-corrugated sheet in roof covering complete all as a specified and as directed
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
All as per Item No. 84.00 above but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
S&F in repair 0.80mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed)
S&F in repairs 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap as in roof, wall fixed with L-type or J- type or crancked hook bolts in lieu screw complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description in rafters, purlins and wind ties wtc complete all as specified and directed.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed.
S&F for Framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, and for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.all as specified and directed.
Supply and fixing mild steel wind ties for roof including securing bolts complete all as specified. (NOTE: Measurement shall be taken for the ms flat only. Quoted rate is deemed to include for the cost of securing bolts etc)
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
M&L for welded steel wire fabric, weight not exc 4.00 kg per square, supplied and fixed complete to wood or steel members
M&L in repair for Mild steel, plain, 1.00 mm thick black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L preparation of new or previously untreated wooden or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of wood primer complete all as specified and directed.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris out from MD land complete all as specified and as directed. Note:- Dismantling and refixing of the lightening strip is deemed to include the rate quoted if any.
M&L for brushing cement slurry @ 3 Kg/sqm over cleaned roof surface prior to application of concrete complete all as directed by Engineer - in - charge .
M&L for Providing Cement Concrete, Type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding, finished even and fair complete all as directed by Engineer - in - charge .
M&L 15 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.10 litre per sqm over APP membrane.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ fly-ash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ fly-ash Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed.
M&L Providing cement concrete type B1 (1:2:4) using 20 mm graded aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) with joints to match complete all as specified and as directed.
Taking down cement plaster on brick or concrete surfaces incl racking out joints, hacking for key, scrubbing down with water etc. all as specified and directed.
M&L for dubbing out cement plaster (1:4), average 10 mm thick on irregular faces of walls (when specially ordered in writing) complete all as a specified and as directed
M&L Rendering 15mm thick, on fair faces of brick or concrete surfaces of walls in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
M&L 10 mm thick rendering on ceiling surfaces in cement mortar 1:3, finishing even and smooth without using extra cement including necessary scaffolding complete all as a specified and as directed
M&L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only"
Supply only liquid water proofing compound complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls by cleaning, brooming, rubbing and scrapping as required using broom, emery paper, putty blade/scraper as applicable to make the surface free from protrutions, loose particles, dust etc including necessary safety & protective measures such as safety belt, headgear etc, finishing the surface with 1.5 mm thick wall putty for smooth finish and finishing with two coats of acrylic distemper, finished with rollers over a coat of alkali resistant primer and necessary scaffolding for any building height complete all as specified and directed.
All as per Item No. 112.00 but on ceiling
M&L Preparing new Surfaces of walls and applying Three coats of white wash complete all as specified and as directed.
M&L for complete removal of existing treatment on old painted surfaces of walls and soffit of chajja, roof slab etc. by scrapping and removing treated surfaces with mechanical wall sander (having vacuum mechanism for suction) having minimum 1500 RPM, sanding pad of 80 grit size having 7"- 9" dia (as required) including cleaning, watering to make the surface clean and free from dust, for upto 4 storey building height including necessary scaffolding, safety and protective measures complete all as specified and directed.
M&L for applying 2mm thick wall care putty (in two layers) on old cleaned surfaces of walls, soffits of chajja, roof slab etc, for smooth finish and finishing with two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make using airless spray technology capable of operating single spray gun with hose of adequate length for upto 4 storey building height including necessary scaffolding, safety and protective measures complete all as specified and directed.
M&L for preparation of new surfaces of walls and soffit of chajja, roof slab etc., by cleaning, brooming, rubbing and scrapping as required using broom, emery paper, putty blade/scraper as applicable to make the surface free from protrutions, loose particles, dust etc including necessary safety & protective measures such as safety belt, headgear etc, finishing the surface with 2 mm thick exterior wall putty (in two layers) for smooth finish and finishing with two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 storey building height complete all as specified and directed.
M&L for preparation of old treated/painted surfaces of walls and soffit of chajja, roof slab etc., by cleaning, brooming, rubbing and scrapping as required using broom, emery paper, putty blade/scraper as applicable to make the surface free from loose paint, algae formation, dust etc including necessary safety & protective measures such as safety belt, headgear etc including filling cracks upto 5mm with and including suitable elastomeric crackfill paste and applying one coat of weather proof exterior emulsion paint of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 storey building height complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls by cleaning, brooming, rubbing and scrapping as required using broom, emery paper, putty blade/scraper as applicable to make the surface free from protrutions, loose particles, dust etc including necessary safety & protective measures such as safety belt, headgear etc, finishing the surface with 1.00 mm thick wall putty for smooth finish and finishing with two coats of acrylic distemper, finished with rollers over a coat of alkali resistant primer and necessary scaffolding for any building height complete all as specified and directed.
All as per Item No. 119.00 but on ceiling
M&L for complete removal of existing treatment on walls and applying texture finish paint with rollers, of approved colour & design, applied over a coat of alkali resistant primer over and including 2 mm thick wall putty complete all as specified and as directed.
M&L for preparation of surface and pasting of wall paper of any design/ pattern/ Shade complete all as per specified and directed. (Make :- Asian/ Nerolac/ Berger/ Dulax)
M&L for preparation of old surface and applying two coats of plastic/acrylic emulsion paint, finished with rollers over a coat of suitable primer applied over 1.0 mm thick wall putty complete all as specified and directed.
M&L for preparation of old painted brick, concrete, stone, asbestos cement or plastered surfaces of any description over 10 cm width or girth and applying one coat of acrylic emulsion/plastic emulsion paint, finished with rollers complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted brick, concrete, stone, asbestos cement or plastered surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, finished with rollers complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer after complete removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth all as specified and directed.
M&L for applying one coat of white wash to old decorated (white washed) surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L for applying one coat of white wash to old decorated (white washed) surfaces of ceiling including preparation of surface complete all as specified and directed.
M&L for applying one coat of acrylic distemper, finished with rollers to old decorated surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed.
All as per Item No. 129.00 but on ceiling
M&L for applying one coat of synthetic enamel paint to old painted steel surfaces of any description over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint to old painted wooden surfaces of any description over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M&L for applying one coat of cement base paint using brush to old decorated surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed.
M&L for repair to chajja/projected portion, area exc 2 sqm but not exc 4 sqm each by removing all broken, loose materials and repairing with cement mortar 1:3 or PCC 1:2:4 type B0 (uing 12.5 mm graded stone aggregates) on top mixed with liquid WPC as per manufacturer's instruction including benching, haunching, repair to broken plaster with dubbing coat with cement mortar 1:4 including necessary formwork complete all as specified and directed.
M&L for repair to chajja/projected portion, area exc 1 sqm but not exc 2 sqm each by removing all broken, loose materials and repairing with cement mortar 1:3 or PCC 1:2:4 type B0 (uing 12.5 mm graded stone aggregates) on top mixed with liquid WPC as per manufacturer's instruction including benching, haunching, repair to broken plaster with dubbing coat with cement mortar 1:4 including necessary formwork complete all as specified and directed.
M&L for uprooting of plants or vegetation growth from wall up to roof level, applying two coats of tartaric acid and repair to broken/chipped off plastered surfaces with cement mortar 1:3 mixed with liquid water proofing compound as per manufacturer's instruction and sealed with 85/25 grade hot blown bitumen in patch not exc 2.0 sqm and removal of debris outside MOD land and disposed off complete all as specified and directed by Engineer -in charge.
M&L for repairing of damaged portion of mouth at terrace/roof surface of rain water pipe by cleaning and repairing of mouth of RWP by using cement mortar (1:3) mixed with liquid water proofing compound and sealed with 85/25 grade hot blown bitumen to mke joint of rain water pipe and roof surface fully leak proof complete all as specified and directed.
S&F in repair circulator/ ventilator wind driven turbine with FRP base of size 32" x 24" to match roof sheet with polyster resin powder caoted, top of ventilator made out from aluminium with integrated and reinforced main bearing housing the shaft of stainless steel and varpitch from aluminium, rotation bearing will be twin ZZ ball bearing encased in single integrated bearing housing etc complete all as specified and directed. (Make : SVS, Model : Hurricane 600 or equivalent model in Shirjee/ Golden Engineers/ Airier)
S&F Suspended metal grid Ceiling System with mineral fibre acoustic tiles as per following specifications:- a) Ceiling Tiles:- Mineral fibre acoustic tile of 16mm thickness having sand textured finish with acoustical punchers, bevelled tegular edge and 8mm drop in module size of 600 x 600mm. Tiles shall have humidity reistance (RH) of 99%, NRC 0.50 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 33db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84.
b) Metal Grid:- The grid system shall be 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. The ceiling grid sections shall be fixed to ceiling with 6 mm dia GI hangers upto required length by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5mm dia 40 mm long. (MAKE OF CEILING GRID : ARMSTRONG, Model: SUPRAFINE 38 or equivalent in GYPROC / USG BORAL / UNISTEEL MAKE OF CEILING TILES: ARMSTRONG, Model: DUNE or equivalent item in GYPROC / USG BORAL / U TONE).
SHEIKH ENTERPRISE
dutta and dutta
DEB AND COMPANY
MODERN AGENCY
M/S SRINIVASA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .