Cottonbee Agro Producer Company Limited
Gat No.65 Mouja Shekapur Tq.Warud Distt Amravati
Proposed Construction of Cotton Ginning and Pressing Factory Shed 644.74 Sqm. Cotton Godown Shed Cotton Bale Shed 515.65 Sqm.
2024_DOAWB_1088416_2
SMART/AMRAVATI/COTTONB/WORKS-2
Open Tender
Civil Works
Item Rate
365 days
Gat No.65 Mouja Shekapur Tq.Warud Distt Amravati
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Exempted
3 Jan 2025
8 Oct 2024
15 Oct 2024
8 Oct 2024
14 Oct 2024
8 Oct 2024
Amount
Sub-Work-1 Civil Construction Work
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Spec.No. : Bd.A.1/Page No.259 (SSR Sr No.721, Item No.21.02)
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No. : As directed by Engineer in charge. (SSR Sr.No.754, Item No.21.40)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. : Bd. E. 1/Page No. 287 (SSR Sr.No.827, Item No.24.01)
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec.No: Bd.F.3 Page No. 298 and B.7,/Page No.38 (SSR Sr. No.836, Item No.25.11)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) spec.No.: Bd.F.5/Page No. 300/I.S. 456(2000)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec.No.: Bd.F.6 Page No. 300 and B.7, Page No.38 (SSR Sr.No.846, Item No.25.50)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. Spec.No.: Bd.F.8 Page No. 302 and B.7, Page No.38 (SSR Sr.No.851, Item No.25.70)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec.No.: Bd.F.17, Page No. 306 (SSR Sr. No.871, Item No.26.33)
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No. : Bd.A.11 Page No. 263 (SSR Sr.No.749, Item No.21.37)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Spec.No.: Bd.G. 1 Page No. 313 (SSR Sr.No.889, Item No.27.01)
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. : Bd.E. 3/Page No. 288/I.S. 456 (2000) (SSR Sr.No.835, Item No.24.16)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec.No.: Bd.L.7/Page NO.369 (SSR Sr.No.963, Item No.32.11)
Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. Spec. No. : As directed by Engineer in charge (SSR Sr.No.1017, Item No.33.30)
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) Spec.No.: BD-T-55 Page No. 510 (SSR Sr.No.1218, Item No.39.25)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. Spec.No.: As directed by Engineer in charge. (SSR Sr.No.737, Item No.21.22)
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Spec.No.: As directed by Engineer in charge. (SSR Sr.No.1090, Item No.35.21)
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. Spec.No.: As directed by Engineer in charge. (SSR Sr.No.1095, Item No.35.26)
Sub-Work-2 Structural Steel Work (PEB) Structural Steel Structural Steel E-350 (JSW make)
Supplying, fabricating,erecting and fixing in position steel structures at all elevations using welding quality steel E-350 (Fe490) confirming to IS: 2062-2006. Rate shall include cost of cutting, welding, slice plates and packing plates, transporting, straighteing, cleaning, fabricating and erecting in position welded/bolted Structural steel work in columns, beams, trusses, purlins, platforms, ladders, monorails, staircases, supports, straighteing of steel members etc. at site to line and level, supply of approved bolts/nuts/washers etc. completed as per drawing including painting, as per G4/G5/G6 before erection and all materials and labour charges etc. completed and including sand blasting & painted with 1 coat of enamel paint (Berger EPILUX SG-HHI 664002) of 35-50 micron each coat with air less spray gun over a coat of zinc chromate primer - 35-50 micron etc. completed as shown in drawing as per specifications and as directed by Engineer in charge/Construction Manager. (The Rate Shall Include cost of bolts,nuts,Washers,welding and electrodes, required for complete work) Spec.No.: As directed by Engineer in charge. (Item No.SST01) Structural Steel - Cold Formed Light gauged (Essar Make)
Supplying,fabricating,erecting Cold Formed Light gauge Structural steel members confirming to IS: 4759- 96 including cutting, welding or bolting, splice plates and packing plates, transporting, straighteing, cleaning, fabricating and erecting in position Spec.No.: As directed by Engineer in charge. (Item No.SST02)
Supplying & fixing of PPGL sheets of 0.5mm thick as shown in drawing or as directed by Engineer in charge with all necessary accessories (Essar Make) Spec.No.: As directed by Engineer in charge.
Supplying & fixing of PPGL sheets of 0.5mm thick PPGL roof accessories as per drawing or as directed by Engineer in charge. Spec.No.: As directed byE ngineer inc harge.
Corner Flashing
Center Ridge
Gable flashing
Supplying, fabricating,erecting in position PPGL Eaves Gutter of required size with stop ends all fixing accessories, drop ends etc. at all elevations levels & heights including aligning, leveling, providing and fixing bolts, nuts, washer etc. confirming to latest specifications including straighteing, cutting, welding, bending to shape, bolting etc. completed and ad directed as per Engineer in charge. Spec.No.: As directed byE ngineer inc harge.
Downtake Pipe Providing and fixing of the rain water down take pipes of PPGL the sectional area of rain water down pipes provided shall be generally at the rate of 1 square cm per 70 to 80 square decimeter of roof area drained. No spout shall be less than 80mm in diameter. The spacing of spouts shall be arranged to suit the position of openings in the wall including necessary accessories for fixing the pipe and including all materials and labour charges etc. completed as shown in drawings as per specifications and as directed by Engineer in charge. Spec.No.: As directed by Engineer inc harge.
Polycarbonate Sheet Supply & Fixing of 2mm. Thk. Polycarbonate sheets as per drawing & as directed by enginner-in-charge. Spec.No.: As directed byE ngineer inc harge.
Turbo Ventilators Supply & Fixing of turbo ventilators with 610mm throat having base ring & top plate in stainless steel of 0.8mm thick, rotated using twin bearings of SKF - 600122 & 600322 permanently lubricated & sealed. Fixed in FRP base plate of 2mm. Thk, clear 1.020mtr. wide & 1.7mtr long Spec.No.: As directed byE ngineer inc harge.
Sub-Work-3 Electrification Work
Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WGMA/ CC. Spec.No.: WG-MA/CC. (Item No.1-1-7, Page No.3)
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. Spec.No.: WG-MA/CC. (Item No.1-1-9, Page No.3)
Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW Spec.No.: WGMA/BW (Item No.1-3-1, Page No.5)
Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WGMA/BW Spec.No.: WGMA/BW (Item No.1-3-2, Page No.5)
Supplying & erecting mains with 2x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW Spec.No.: WGMA/BW (Item No.1-3-4, Page No.5)
Supplying and erecting mains with ISI mark WP 2 x 6 sq. mm.1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. Spec.No.: (Item No.1-4-3, Page No.6)
Supplying and erecting ISI mark modular type switch 6A /10A duly erected on provided plate and box with wiring connections complete. Spec.No.: (Item No.1-6-1, Page No.8)
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. Spec.No.: (Item No.1-6-2, Page No.8)
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. Spec.No.: (Item No.1-6-10, Page No.9)
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. Spec.No.: (Item No.1-6-11, Page No.9)
Supplying and erecting ISI mark modular type switch 16 / 20A with indicator, duly erected on provided plate and box with wiring connections complete. Spec.No.: (Item No.1-6-6, Page No.8)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background Spec.No.: (Item No.1-6-35, Page No.10)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background Spec.No.: (Item No.1-6-36, Page No.10)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background Spec.No.: (Item No.1-6-37, Page No.10)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. Spec.No.: (Item No.1-6-38, Page No.10)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. Spec.No.: (Item No.1-6-39, Page No.10)
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW Spec.No.: (Item No.1-7-26, Page No.13)
Supplying, erecting & marking SPMCB 6A to 32A, Cseries with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Spec.No.: (Item No.5-3-2, Page No.90)
Supplying, erecting & marking SPMCB 6A to 32A, Bseries with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Spec.No.: (Item No.5-3-3, Page No.90)
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SWSWR/ MCB Spec.No.: (Item No.5-3-10, Page No.90)
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SWSWR/ MCB Spec.No.: (Item No.5-3-11, Page No.90)
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent,rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SWRCCB/ RCBO Spec.No.: (Item No.5-6-13, Page No.95)
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB Spec.No.: (Item No.5-4-1, Page No.91)
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 Spec.No.: (Item No.5-4-15, Page No.93)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Spec.No.: (Item No.7-1-26, Page No.127)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Spec.No.: (Item No.7-1-27, Page No.127)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Spec.No.: (Item No.7-1-29, Page No.127)
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI Spec.No.: (Item No.9-1-5, Page No.160)
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. Spec.No.: (Item No.2-1-22, Page No.25)
Royalty
Murum
Soling 80mm
Carrying out various quality control tests as per As per statement attached
MIX DESIGN M-20 Concrete Concrete Mix Design (With all Tests on basic materials)
CONCRETE CUBE TEST
M20 CONCRETE: Concrete Mix Design (With all Tests on basic materials)
M20 CONCRETE: Compressive Strength OF C.C. Cube (Set of 3
M10 CONCRETE: Compressive Strength OF C.C. Cube (Set of 3 cubes).
BRICKS : Water Absorption (Set of 5 Bricks), Compressive strength (Set of 5 Bricks), Efflorescence (Set of 5 Bricks)
TMT STEEL : (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
Sand :- i) Fineness Modulus, II) Silt content
Murum :- ii) Atterberg Limit iii) Density of compacted layeriv) Proctor Test
Crushing Value/Compressive Strength, Water Absorption & Specific Gravity,
Cement Test i) Comprecive strengh ii) Intital and final setting time iii)Spcific Gravity iv) Spicific Gravity v) soundness vi) Finess
METAL Gr I & Gr II Agrregates AIV Test, Gradation,Water Absorpation Test,Crushing Value
Management Strategies and implementation plan (MSIP) to manage the Environmental Social Health and safety (ESHS) risks and ESHS Code of Conduct
S B PACHODE (BID ID -6293361)
SHAHEDKHAN RAJAKHAN PATHAN (BID ID -6295133)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .