Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.8 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 BIDDER | |
| 2 | L2₹50.1 L+₹1.3 L (2.75%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L2 BIDDER | |
| 3 | L3₹53.2 L+₹4.4 L (9.09%)Rejected-Finance CAMP TENGA MARKET P O P S TENGA VALLEY DIST WEST KAMENG ARUNACHAL PRADESH PIN 790 116 | WEST KAMENG | ARUNACHAL PRADESH | 790116 | L3 | Rejected-Finance REJECTED DUE TO L3 BIDDER | |
| 4 | L4₹53.3 L+₹4.6 L (9.43%)Rejected-Finance | L4 | Rejected-Finance REJECTED DUE TO L4 BIDDER | |
| 5 | L5₹54.5 L+₹5.8 L (11.8%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO L5 BIDDER |
| Sl No | Description | Qty | Unit | M/S SM ANSARI L7 | M/S SUNRISE CONSTRUCTION AND CO L6 | M/S R P M CONSTRUCTION L3 | M/S EVERGREEN KAMENG VALLEY SYNDICATE L1 | M/S MURPHEW ENTERPRISES L4 | M/S ASHOK CONSTRUCTION L2 | M/S DKT CONSTRUCTION L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out hard & densile soil complete all as specified and as directed. | 420 | Cum | 800 ₹3,36,000 | 835 ₹3,50,700 | 780 ₹3,27,600 | 740 ₹3,10,800 Lowest | 780 ₹3,27,600 | 750 ₹3,15,000 | 805 ₹3,38,100 |
| 2.00 | Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. | 280 | Cum | 280 ₹78,400 | 280 ₹78,400 | 270 ₹75,600 | 230 ₹64,400 Lowest | 255 ₹71,400 | 230 ₹64,400 Lowest | 285 ₹79,800 |
| 3.00 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. | 140 | Cum | 400 ₹56,000 | 420 ₹58,800 | 400 ₹56,000 | 350 ₹49,000 | 400 ₹56,000 | 340 ₹47,600 Lowest | 410 ₹57,400 |
| 4.00 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed by E-in-C. Note:- The total thickness of sand shall be measured 18 cm after punning. | 120 | Cum | 1,800 ₹2,16,000 | 1,700 ₹2,04,000 Lowest | 1,800 ₹2,16,000 | 1,800 ₹2,16,000 | 1,800 ₹2,16,000 | 1,850 ₹2,22,000 | 1,800 ₹2,16,000 |
| 5.00 | Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm, factory made of specified make , complete all as specified and directed by E-in-C. | 4 | CUM | 16,000 ₹64,000 | 15,000 ₹60,000 | 16,000 ₹64,000 | 13,500 ₹54,000 | 15,200 ₹60,800 | 13,400 ₹53,600 Lowest | 16,000 ₹64,000 |
| 6.00 | Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following:- (a) Aluminium bus bar four Nos 500 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos, Incoming:- (b) MCCB, 04 Pole, 250 Amps with ultimate breaking capacity Icu- 50 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%), Outgoing:- (c) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 No (Ics=Icu=100%), (d) Spare way for MCCB 100 Amp 4 pole - 01 Nos, (e) Digital type volt meter 0-300 volt with selector switch with HRC fuses/ MCBs - 1Set. (f) Digital type ammeter meter 400 Amp with selector switch with HRC fuses/ MCBs - 1Set. (g) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set, (h) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU, (j) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel complete all as specified and directed by E-in-C | 5 | Each Job | 3,00,000 ₹15,00,000 | 3,00,000 ₹15,00,000 | 2,90,000 ₹14,50,000 | 2,63,000 ₹13,15,000 Lowest | 3,00,000 ₹15,00,000 | 2,88,000 ₹14,40,000 | 3,10,000 ₹15,50,000 |
| 7.00 | Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following :- (a) Aluminium bus bar four Nos 300 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos, Incoming:- (b) MCCB, 04 Pole, 160 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%), Outgoing:- (c) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 No (Ics=Icu=100%), (d) Spare way for MCCB 100 Amp 4 pole - 01 Nos, (e) Digital type volt meter 0-300 volt with selector switch with HRC fuses/ MCBs - 1Set, (f) Digital type ammeter meter 400 Amp with selector switch with HRC fuses/ MCBs - 1Set, (g) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set, (h) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU, (j) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel complete all as specified and directed by E-in-C | 2 | Each Job | 2,45,000 ₹4,90,000 | 2,30,000 ₹4,60,000 | 2,25,000 ₹4,50,000 | 1,81,000 ₹3,62,000 | 2,20,000 ₹4,40,000 | 1,80,000 ₹3,60,000 Lowest | 2,20,000 ₹4,40,000 |
| 8.00 | S&F & testing commissioning of outdoor type bus bar panel pedestal type weather proof CPRI approved MS cubical panel board outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of bus bar of 300 Amp capacity & MCCB 160 Amp capacity 4 pole (Ics = Icu = 100%) including one coat of red oxide and two coat of enamel paint powder coated, mounted on channels and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator complete all as specified and directed by E-in-C. The panel shall be fixed over Angle iron frame (50 x 50 mm) of minimum height 75 cm Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel | 2 | Each | 91,000 ₹1,82,000 | 91,000 ₹1,82,000 | 89,000 ₹1,78,000 | 84,000 ₹1,68,000 Lowest | 90,000 ₹1,80,000 | 85,000 ₹1,70,000 | 91,000 ₹1,82,000 |
| 9.00 | S & F in replacement of change over switch with advanced neutral, ON LOAD, 63 Amps, 4 pole, AC 415 Volt, manual Change over insheet metal enclosure including operating handle conforming to IS:13947 (Part-3) complete all as specified and directed by E-in-C. | 2 | Each | 13,000 ₹26,000 | 14,900 ₹29,800 | 13,000 ₹26,000 | 11,400 ₹22,800 | 12,600 ₹25,200 | 11,000 ₹22,000 Lowest | 14,200 ₹28,400 |
| 10.00 | Description all as per item No 09 here in above but of capacity 100 Amps and ditto- | 2 | Each | 16,000 ₹32,000 | 18,000 ₹36,000 | 16,000 ₹32,000 | 14,400 ₹28,800 | 15,400 ₹30,800 | 11,400 ₹22,800 Lowest | 17,000 ₹34,000 |
Tender Value
₹45.0 L
EMD Value
₹89,960
Closing Date
5 Nov 2025, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE TENGA
GE TENGA PIN-790116 C/O 99 APO
COMPREHENSIVE REPAIR/MAINT OF LT CABLES AND PANELS, UG CABLES, POLES AND CONNECTED LT WORKS AT PH- I MD AREA (RUPA, GACHHAM, BIRPUR, DP, BOMDILA) OF AGE E/M UNDER GE TENGA
2025_MES_728877_3
8040/E8
Open Tender
Civil Works
Item Rate
270 days
GE TENGA
PLS REF NIT
7 documents required · 7 mandatory
₹500
GE TENGA
₹89,960
Yes
13 Nov 2025
22 Oct 2025
6 Nov 2025
22 Oct 2025
5 Nov 2025
29 Oct 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.86 MB
Tender.pdf
Tender Documents • 6.42 MB
BOQ_824594.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .