| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.0 L+₹1.1 L (5.39%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹22.6 L+₹2.6 L (13.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹22.9 L+₹2.9 L (14.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹22.9 L+₹3.0 L (15.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
25 Jun 2025, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIRS TO AREA DRAINAGE PATH CULVERT AND HARD STANDING INCLUDING PLASTERING AND PAINTING SERVICES IN ZONE III AND ZONE IV AREAS UNDER AGE BR II OF GE NAGROTA
2025_MES_710372_1
CANO GEN-38/2025-2026
Open Tender
Civil Works
Item Rate
180 days
NAGROTA
Class D category a i
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹1 L
Yes
31 Jul 2025
27 May 2025
2 Jul 2025
27 May 2025
25 Jun 2025
13 Jun 2025
Amount
Demolition of brick work, stone/boulder masonry built in cement mortar complete all as specified and directed.
Demolition of plain cement concrete in ground floor and paving n.exc 15cm thickness (below & above GL) complete all as specified and directed.
M&L for PCC 1:3:6 Type C-2 (using 40mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and directed.
M&L Brickwork with subclass ‘B’ bricks old size well burnt , straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 except stone complete all as specified and as directed.
M&L for Rendering 15mm thick in two layers (base layer 10mm in CM 1:4 & finishing layer 5mm thick in cement mortar 1:4) using water proofing compound in 2nd layer only on brick work or conrete surfaces or stone masonry surface of wall, surfaces finished even and smooth using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately.
M&L for Providing, cement concrete Type B-0 1:2:4 (12.5mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating incl formwork complete all as specified and directed.
M&L plain Cement concrete Type C2 (1:3:6) using 40 mm graded stone aggregate in surface channels and drains complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for ( reinforment cut to facilitate demolition). complete all as specified and directed.
M&L for Precast cement concrete M-15 (1:2:4 nominal mix ) type B-I, (using 20mm grade stone aggregates) set in cement mortar 1:4 as in manhole cover complete all as specified and directed.
M&L for MS TMT MS bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to E-165 (Fe-290) complete all as specified and directed by Engineer-in-charge.
M&L for 150mm thick Cement concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate as in sub base of floors and pavings, complete all as specified and directed.
M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed.
M&L for Finishing surface of concrete roads, pavements, by brooming complete all as specified and directed.
M & L forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound Grade A upto 100mm thick concrete slab provided all as specified and directed.
M&L Forming Contraction (Dummy) joints Grade 'A' 65mm deep x 10mm wide,filled with sealing compound complete all as specified and directed.
M & L for sand filling 25mm thick under floors or in foundations including watering and consolidation complete all as specified and directed.
M & L PCC 1:3:6 type C2 (75 mm thick as in plinth protection & finishing the surface even & fair W/o using extra cement complete all as specified and directed.
M & L for machine pressed pre cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and pigment complete all as specified and directed.
M & L for machine pressed pre cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment complete all as specified and directed.
M & L Chequered cement concrete tiles of size 20cm x 20cm x 25mm thick (with grey cement and pigments) set, jointed and pointed in neat cement slurry in floor,laid over and incl 15mm thick cement screed base in CM 1:6,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces complete all as specified and directed.
M&L for Reinforced cement concrete Type B1 1:2:4(using 20 mm stone graded aggregate) (Nominal Mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like (20 mm graded aggregate) complete all as specified and directed.
S&F Reinforced concrete pipes,250mm bore class NP2, laid and jointed complete with collars complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil.complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point.complete all as specified and directed.
M&L for Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spot, moulds, moss and efflorescent salts, trading oil, greasy spots etc and applying one coat of cement base paint on walls (upto three storeyed bldgs )complete all as specified and directed.
M&L for Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spot, moulds, moss and efflorescent salts, trading oil, greasy spots etc and applying two coat of cement base paint on walls (upto three storeyed bldgs ) complete all as specified and directed.
M & L for preparation of old plastered surfaces and applying two coats of Anti fungal weather coat with acrylic smooth exterior emulsion paint with silicone additives of required shade applied 1.67 kg/10 sqm of required shade over a coat of primer applied 2.20kg/10Sqm on new or old surfaces including necessary scaffolding for max height of G +2 bldg, etc complete all as spd & directed. Make of Acrylic emulsion weather coat paint: Asian (Apex Ultima), Berger (Super Coat) or ICI Dulux (weather shield), Nerolac, etc Make of primer: Asian or Equivalent.
Supply only integral water proofing compound of approved quality and make confirming to IS complete all as specified & directed
R.K. Works (BID ID -3335730)
BHARTI CONSTRUCTIONS (BID ID -3325873)
M/S MANISHA BUILDERS (BID ID -3327893)
U K Engineering Works (BID ID -3328100)
RAJINDRA ENGINEERS & CONTRACTORS (BID ID -3326654)
Nitika electricals and engineers works (BID ID -3336360)
ASHWANI KUMAR KHAJURIA AND SONS (BID ID -3336001)
bamral builder (BID ID -3334632)
M/S R S CONSTRUCTION CO (BID ID -3324617)
CCC (CHOUDHARY CONSTRUCTION COMPANY) (BID ID -3335533)
M.S Sharma Enterprises (BID ID -3329494)
SHALIMAR CONSTRUCTION CO (BID ID -3325466)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .