GE (AF) PALAM DELHI CANTT 10
GE (AF) PALAM DELHI CANTT 10
PROVN OF ACs IN CNFL COMPLEX AT CPRU and 1 AFDC AT 3 WING, PROVN OF ACs AT IAS AT 3 WING AND PROVN OF FLAME PROOF AC FOR AEROLUBE STORE AT LOGISTIC SECTION UNDER GE (AF) PALAM DELHI CANTT-10
2026_MES_797968_1
8026/A/T-72/E8
Open Tender
Civil Works
Item Rate
90 days
GE (AF) PALAM DELHI CANTT 10
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) PALAM DELHI CANTT 10
₹63,600
Yes
9 Nov 2026
9 Nov 2026
7 Dec 2026
9 Nov 2026
30 Nov 2026
23 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of Air Cooled Hi Wall Split type Air Conditioners inverter type 5 star BEE rating for 2.0 TR complete with indoor unit (IDU), Outdoor unit (ODU), surface/ concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) minimum 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) I/c drain pipe R-32/R-410/R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 Hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation with rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Calcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). The appliances must comply- Electrical cable IS 694 or IS 9968, temperature sensing control IS / International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. | 21 | Each | - | - |
| 2 | Description all as per ser item No 1 here-in-before but for AC inverter type 5 star BEE rating for 1.5 TR complete all as specified and as directed. | 5 | Each | - | - |
| 3 | Description all as per ser item No 1 here-in-before but for AC inverter type 5 star BEE rating for 1.0 TR complete all as specified and as directed. | 2 | Each | - | - |
| 4 | Description all as per ser item No 1 here-in-before but for AC inverter type "Hot and Cold" 3 star BEE rating for 2.0 TR (-7 to 55 Degree) complete all as specified and as directed. | 2 | Each | - | - |
| 5 | Supply of Window type Air conditioners inverter type 5 star BEE rating for 2.0 TR complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180-260V with low & high voltage cutoff and 50 Hz, 1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A/R-407B Green Refrigerant with Scroll/ rotary compressor with min 5 years Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuti Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified. The sound level shall be upto 50dB inside the room is acceptable. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. The system shall be able to operate upto 50 Degree Celcius (Outdoor ambient tempreture). | 1 | Each | - | - |
| 6 | Description all as per ser item No 5 but window AC of inverter type 5 star BEE rating for 1.5 TR complete all as specified and as directed. | 3 | Each | - | - |
| 7 | Description all as per ser item No 5 but window AC of inverter type 5 star BEE rating for 0.75 TR complete all as specified and as directed. | 1 | Each | - | - |
| 8 | Supply and installing AC stand for outdoor unit of split type AC surface/wall mounted outdoor unit complete all as specified and directd by Engineer-in-Charge. | 15 | Each | - | - |
| 9 | M&L for insulating the suction and discharge copper tubing from indoor unit to outdoor unit of split type ACs of capacity 1.5/2.0 TR capacity with neoprene foam sleeves including sealing by applying adhesive tape of brown or white colour to avoid minimum contact with atmosphere complete all as specified and as directed by Engineer-in-charge. | 20 | RM | - | - |
| 10 | M&L for suction and discharge copper tubing of size 1/2 inch and 1/4 inch dia and 0.5mm thickness from indoor unit to outdoor unit of split type AC 1.5 TR capacity including soldering and braizing complete all as specified and as directed by Engineer-in-charge . | 170 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
tender.pdf
Tender Documents • 0.52 MB
BOQ_895151.xls
BOQ • 0.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .