| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86.3 LAccepted-AOC | L1 | Accepted-AOC The lowest and negotiated tenderer | |
| 2 | L2₹98.1 L+₹11.8 L (13.7%)Rejected-AOC | L2 | Rejected-AOC Unsuccessful tenderer | |
| 3 | L3₹1.0 Cr+₹14.5 L (16.8%)Rejected-AOC | L3 | Rejected-AOC Unsuccessful tenderer | |
| 4 | L4₹1.0 Cr+₹15.2 L (17.6%)Rejected-AOC PLOT NO 1 510 NO 2 MADHA NAGAR KOVUR CHENNAI 600 128 | KANCHIPURAM | TAMIL NADU | 600128 | L4 | Rejected-AOC Unsuccessful tenderer |
Tender Value
Refer Docs
EMD Value
₹67,700
Closing Date
12 Jul 2023, 6:00 pmClosed
The Superintending Engineer/TNPHCL/NC/Salem
The Superintending Engineer/TNPHCL/North Circle, No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem 636 006.
Providing repair and renovation works to Thippu Mahal, Law class rooms, Meeting Hall and providing New Over Head Tank at Permanent PRS (Inside Fort) in Vellore District for the year 2023 2024.
2023_TNPHC_335341_1
SE/NC/DB/1572/2023
Open Tender
Civil Works
Lump-sum
90 days
PRS (Inside Fort) in Vellore District
Refer the tender documents
7 documents required · 7 mandatory
₹0
₹67,700
29 Aug 2023
4 Jul 2023
14 Jul 2023
4 Jul 2023
12 Jul 2023
4 Jul 2023
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
30 : Finishing the top flooring with Ellis Pattern
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
52 : PVC Water supply (ASTM) a. 50 mm dia
a. 32 mm dia
Electrical arrangements 69 : 15 Amp. Power plug
74 : Charges for fixing of "Fan"
78 : Earthing Station IS3043 (Type I)
ANNEXURE-I 3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.2.1 : P.C.C. 1:2:4 for Foundation & Basement and other similar works (using crushed stone sand)
6.5.1 : Brick work in C.M. 1:5 (F& B) using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") (using crushed stone sand) with admixture
8.1.1.1 : Standardised concrete Mix M20 Grade concrete. (using crushed stone sand) a) In Foundation and Basement.
b) In Ground Floor
c) In First Floor.
d) In Second Floor.
9.5.1 : Brick work in C.M. 1:6 using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") (using crushed stone sand) with admixture a. In Ground Floor
10.5.1 : Brick partition work in C.M. 1:4 using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") 110 mm tk (B.P.) (using crushed stone sand) with admixture B. In Ground Floor
18.1 : Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam,Raftbeam,Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
d.For Vertical wall
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
23.1.1 : Supplying and fixing of best Indian TW single leaf door shutters using 9 mm thick phenol bonded BWR grade plywood a) For Door Size 900 X 2100
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) with plasticizer
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) with plasticizer
35.1.1 : Plastering 1:3, 12mm with WPC (using crushed stone sand)
35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand) with plasticizer
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk. (using crushed stone sand) a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.7 :Plastic Emulsion Paint including primer for new walls
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
53.4 : S&F of C.I Manhole cover 60 x 60 cm (50kg weight )
54.2.1 : S & F of 15mm dia half turn CP short body tap
71.2: Supplying and fixing of 32Amps triple pole main switch with fuse and neutral link
75.1.2 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
80.1: S & F of 450 x 375 x 20mm thick TW plank
85.1Supply and fixing of 40 mm DIA GI pipe B class for EB service connection (Three Phase) for passing through from top of house to the EB board.
105.1 : 4 x 4 Sq mm copper PVC insulated unsheathed single core cable for 3 phase EB service connection.
209.1:Removing the existing AC sheet roofing without roof timbers and carefully stacking materials useful for re-use including all labour charges etc
212: Dismantling the Plain cement concrete and clearing away and carefully stacking the materials useful for reuse and premeasurement and removing the debries as per the instruction of departmental officers
214: Dismantling the existing Brick masonry wall in cement mortor and stacking the desegregated unwanted materials neatly at site work a.) Brick walls under 3m height
361.5.1: Vitrified Tiles flooring (ivory) (using crushed stone sand)
ANNEXURE - II A1:Removing the existing thermocoal false ceiling and carefully stacking materials useful for re-use including all labour charges etc, all complete
A2: Removing the existing electrical fittings like light point, Fan points stacking at stack room etc., all complete
A3: Removing the existing wrought and put up framed timbers in roofs / floors and carefully stacking materials useful for re-use including all labour charges etc
A4: Removing the Flat & Mangalore tiles over flat tiles without roof timbers and carefully stacking materials useful for re-use including all labour charges etc
A5: Plastering with CM 1:5, 20mm thick (using crushed stone sand) with plasticizer
A6 : Terrace waterproofing: (i) Through cleaning of the surface to remove dirt, dust, loose particles and micro organism growth. (ii) All loose portions, cracks and voids should be filled with polymer grout. (iii) The prepared suurface should then be coated with a single coat of bitumen emulsion primer and allowed to dry. (iv) 3mm thick polyester modified APP waterproofing membrane shall be unrolled over the coated primer surface by flame using LPG torch and also overlaps are then thermo fused by flame. The laid membrane is uniformly pressed to the full width of the membrane without any air gaps and sealed. (v) Providing a coat of reflex paint over the membrane and completed as per standard practices
A7: Supply and fabrication of roof truss work arrangements using rectangular tube of size 100x50x3mm thick, square tube 100x100x5mm thick for alround truss and 60x40x3mm thick rectangular tube for horizontal purlins including labour charges for fixing transportation, fasteners, one coat of red oxide primer etc., all complete.
A8:Supplying and fixing PUF panel roof sheet of top thickness of 0.45mm and bottom thickness of 0.40mm, top sheet colour brick red, bottom sheet colour oof white, PUF density 38Kg/cum (+or- 2Kgs), core thickness of 50mm insulation, panel width 1.06m (standard) bending strength (kg/cm2) 4, closed cell content 92-95%, paint coationg top coat (18-22) micron, back coat (5-8) micron including cost of errection, fasteners, transportation charges etc
A9: Supply and fixing of Galvanium sheet 0.47mm thick for wall cladding works including cost of labour for fixing, washer and bolt connection etc
A10: Supplying and fixing of Gavanized iron sheet using 22 gauge thickness over the country wood reepers for roofing including labour charges for fixing complying with standard specifications etc
A11: Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (open wiring) a. Light Point with ceiling rose.
b. Light Point without ceiling rose
A12: Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.(open wiring)
A13: Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.(open Wiring)
A14: Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.(open Wiring)
A15: Supplying and fixing of 18W LED TUBE LIGHTS 4' long with necessary fittings and charges for assembling and fixing
A16: 2 x 4 Sq mm copper PVC insulated unsheathed single core cable for single phase EB service connection.
A17: Supply and fixing of Vertical TPN 4 way triple pole Distribution board double door IP43, as per IS 8623 III; Impact resistance IK09; Frame 4 pole Isolator MCB type Incomer & Three Phase MCBs as Outgoing with bus and neutral link and earth link and with 1 No. of 63A FP Isolator MCB type and 1 No. 63A FP 30 MA ELCB as incoming and 12 Nos. 6A - 20A, 10 KA SP MCBs as outgoing with bus bar and double door arrangements in flush wall / on surface making good of the concealed portion with earth connection etc, all complete for power load exceeding 100A, 4 wat MCCB+12 modules.
A18: Supply and fixing of Vertical SPMCB 4 way single pole Distribution board with metal door IP42, 2 pole Isolator MCB type Incomer & single phase MCBs as Outgoing with bus and neutral link and earth link and with 1 No. of 40A DP Isolator MCB type as incoming and 2 Nos. 6A - 20A, 10 KA SP MCBs as outgoing with bus bar arrangements in flush wall / on surface making good of the concealed portion with earth connection etc, all complete.
A19: Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (Open Wiring).
A20: Run of 4 Wires of 6 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.(open Wiring)
A21: Supply and fixing 5Amps flush type switch in existing switch board including cost of material and labour charges fixing the etc
A22: Supplying and fixing of 25W LED Street light with necessary fittings (Superior variety) Charges for fixing 25W LED lamp street light fittings
A23: Supplying, delivery and fixing of ISMC section of size 125x65x5.3mm and 75x40x4.8mm including cost of trasportation etc
A24: Labour charges for fixing of ISMC section below the madras terrace roof including cost of necessary dismantling the existing damaged wooden rafters, fixing the ISMC channel, concrete packing and finishing etc
A25: Supplying and fixing of Country wood wrought and putup a) Country wood scantling upto 4.00 metre length
A26: Finishing the top of roofing with exsiting mangalore tiles class AA set cement mortor 1:5 over flat tiles 15cm x 15cm x 12mm including cost of country wood reepers 50 x 25mm and labour charges etc., all complete and as directed by the departmental officers. (Excluding cost of Mangalore tile, Flat tile)
A27: Finishing the top of roofing with Mangalore tiles class AA set cement mortor 1:5 over flat tiles 15cm x 15cm x 12mm including cost of country wood reepers 50 x 25mm and labour charges etc., all complete and as directed by the departmental officers. (Including cost of Mangalore tile, Flat tile).
A28: White Washing two coats for old walls using clean shell lime slaked including cost of lime, gum, blue, brushes, including thorough scrapping the existing surface, scaffolding etc., all complete.
A29: Colour Washing for Old walls two coats using clean shell lime slaked including cost of lime, gum, blue, brushes, including scaffolding and scrapping the existing surface etc., all complete.
A30: Painting the old wood work with one coat of approved first class enamel ready mixed paint in of approved quality and shade, the paint should be supplied by the contractor at his own cos complying with relevant standard specifications. (Incl. Scrapping)
A31: Painting the old iron work with one coat of approved first class enamel ready mixed paint in of approved quality and shade, the paint should be supplied by the contractor at his own cost complying with relevant standard specifications (Incl. Scrapping)
A32: Supplying and laying of following Dia GI pipe of best and approved quality having ISI mark including cost of materials and labour charges for fixing with necessary specials etc., all complete and as directed by the departmental officers. (Above GL) a.) 50mm Dia GI Pipe 'B' Class
A33: Supply andfixing of following dia GI/GM Specials a).40mm Dia GM Gate valve
b.) 32mm Dia GM Gate valve
c).32mm Dia GI Hex Nipple
sathiyanarayana constructions
Selvam
S.S. ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_398427.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .