Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
15 Apr 2021, 5:00 pmClosed
Medical Superintendent cum Member Secretary, RMRS
SMS Hospital, Jaipur
Two Year Rate Contract for the procurement of Heart Valves
2021_SMSMC_214344_1
615_23.02.2021
Open Tender
Miscellaneous Goods
Item Wise
730 days
SMS Hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Member Secretary, RMRS, SMS Hospital, Jaipur
₹2 L
Yes
SMS Hospital, Jaipur
1 Jun 2021
24 Feb 2021
16 Apr 2021
24 Feb 2021
15 Apr 2021
5 Apr 2021
3 Mar 2021
Mechanical Valve Moulded pivot to fit into calcified annulus Bileafleat prosthetic heart valve with moulded pivot made up pyrolytic carbon (mitral +aortic) opening angle 75 degree or more. Should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring. Should be in use for more than 20 year and acceptability by cardiac surgeon. USFDA approved. Expiration Date should be 3 years from the date of purchase. Only latest version is acceptable.
Mechanical Valve Open pivot with suspended refleat design. Bileafleat prosthetic Heart valve with open pivot suspended lefleat design, Mad of payrolytic carbon (mitral + aortic) of all sizes. Should have tungeston in pregneted leaflet with titanium strengthening ring and optimal exes of suspension. If should w low profile and should give minimum noise. Only latest version is acceptable.
Mechanical Valve. Bileafleat prosthetic Heart valve with opening angle 90 degree made of pyrolytic carbon (mitral + aortic) of all sizes. Should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve low profil sewing ring made up topolyesther should be in use for more than 20 year and acceptability by cardiac surgeon. Should be radio opaque during X-ray and fluoroscopy. Expiration Date should be 3 years from the date of purchase. Only latest version is acceptable.
Mechanical Valve Open pivot design. Bileafleat prosthetic Heart valve with open pivot made of pyrolytic carbon (mitral + aortic) of all sizes. Should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring. should be in use for more than 20 year and acceptability by cardiac surgeon, low profile sewing ring made up of polyester, should be radio opaque during X-ray and fluoroscopy. Expiration Date should be 3 years from the date of purchase. Only latest version is acceptable. With minimum arotic valve size 16mm, and minimum mitral size 23mm. for both intra annular and supra annular placement and meleable handle.
Bileaflet Mechanical Valve All Size of bileaflet Mitral and Aortic Valve with continuously rotating leaflets.Only latest version is acceptable. 17 to 33 sizes, pannus preventing mechanizam, and housing reinforced with titanium alloy stiffening ring.
Mechanical Valve for supra annular placement (both arotic mitral) to fit into narrow annulaus. By rifled prosthesis heart valve med of pyrolytic carbon reinforced by titanium stiff band of all sizes. The housing of prosthesis should be rotatable to give optimal positioning for the valve reinforce with titanium stiff ring. Should be in use for more than 20 year profile ring should be radio opaque during Xray and fluoroscopy expiration date should be 3 years from the date of purchase. Only latest version is acceptable.
Monoleafleat prosthetic Heart valve to fit into server sub valve or fusion made of polyethylene Disc and Haynes Alloy” with swing ring mad from knitted polyester of all size. Should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve. Should be in use for more than 20 year and acceptability be cardiac surgeon. Low profile sewing ring made up of polyester. Should be radio opaque during X-ray and fluoroscopy. Expiration date should be 3 years form the date of purchase. Only latest version is acceptable.
Bioprosthetic Valve. Triple composite bovine pericardial valve with elgiloy/alloy frame stent material for both mitral and aortic position. Only latest version is acceptable.
Tissue Heart valve with stent for mitral and aortic position with all the sizes available should be in clinical use with long term proven result. Only latest version is acceptable.
Stent less tissue heart valve (CE certified) for mitral and aortic position with all the sizes available should be in clinical use with long term proven result. Only latest version is acceptable.
Tissue heart valve with stent (CE certified) for mitral and aortic position with all the sizes available should be in clinical use with long term proven result. Only latest version is acceptable.
Trans catheter aortic valve replacement valve (TAVR). Only latest version is acceptable.
Trans catheter mitral valve replacement valve (TAMR). Only latest version is acceptable.
Bioprosthetic Arotic Valve Conduit valve. Only latest version is acceptable.
Arch Aneurvsm graft with Elephant Trunk Surgery Extension, for Hybrid Stent graft device procsssor. It should have low porosity, one piece implant to be used in Aortic arch and DTA Surgery to avoid Second processor. Only latest version is acceptable. It should be CE/US FDA approved of Various Sizes
Epicardial Pracemaker – adult – VVI pacemaker GENERATOR DCGI & US FDA/CE APPROVED
Epicardial Pracemaker – pediatric – VVI pacemaker GENERATOR DCGI & US FDA/CE APPROVED
Epicardial lead – Sutureless pacing lead for permanents ventricular pacing with an implantable pulse generator, Active – Fixation, Sutureless design. With accessories for Adult
Epicardial lead – Sutureless pacing lead for permanents ventricular pacing with an implantable pulse generator, Active – Fixation, Sutureless design. With accessories for pediatric
GENERATOR FOR DDD Pacemaker – DCGI & US FDA Approved for Ault
GENERATOR FOR DDD Pacemaker – DCGI & US FDA Approved for pediatric
Epicardial lead – Sutureless pacing Lead for permanents ventricular pacing with and implantable pulse generator, Active – Fixation Sutureless design. With accessoreies – for Adult
Epicardial lead – Sutureless pacing Lead for permanents ventricular pacing with and implantable pulse generator, Active – Fixation Sutureless design. With accessoreies – for pediatric
Epieardial lead – Stureless packing Lead for permanents ventricular pacing with an implantable pulse generator, Active – Fixation, Sutureless design. With accessories – for Adult
Epieardial lead – Stureless packing Lead for permanents ventricular pacing with an implantable pulse generator, Active – Fixation, Sutureless design. With accessories – for pediatric
SAHU SURGICAL EMPORIUM PVT .LTD.
GSS DISTRIBUTORS
M/S SINGAPORE MEDICARE SYSTEM
BIOSENSE
India Medtronic Private Limited
SHUBH ASSOCIATES
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .