Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical DUMKA | JHARKHAND | 814101 | Admitted-Fee/PreQual/Technical |
Tender Value
₹4.9 Cr
EMD Value
₹4.9 L
Closing Date
13 Feb 2026, 3:00 pmClosed
District Engineer, Zila Parishad, Dumka
District Engineer, Zila Parishad, Dumka
Construction of Vishal Market Complex Near National School Under Zila Parishad Dumka, District - Dumka
2026_DZPD_109694_1
ZP-DUM-03/2026
Open Tender
Civil Works
Item Rate
540 days
District Dumka
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Yes
₹4.9 L
30 May 2026
24 Jan 2026
17 Feb 2026
24 Jan 2026
13 Feb 2026
24 Jan 2026
Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I.
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
Providing coarse clean sand in filling in foundation trenches or in plinth including thick with all leads and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted voume)
Providing designation 75B one brick flat soiling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforcement cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforcement cement concrete work in beams, suspended floors, roofs having slope up to 15ⴰ landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing .
Providing Tor steel reinforcement of 10mm dia rods as per approved design and drawing .
Providing Tor steel reinforcement of 12 to 25 mm dia rods as per approved design and drawing .
Centering and shuttering including strutting, propping etc. and removal of form for: Foundation, footings, bases of columns, etc for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landing, balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form for: Stairs, (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc, including edges
Providing designation 75B work in C.M. (1:6) in foundation with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints of screening materials, scaffolding, ranking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing designation 75B work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints of screening materials, scaffolding, ranking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing 125 mm thick REINFORCED DESIGNATION 75 A BRICK WORK in C.M. (1:4) in SUPERSTRUCTURE with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15 mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of Engineer Incharge .
Providing 19 mm Thk. cement plaster(1:3) with clean course sand of FM-1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 12 mm Thk. cement plaster(1:6) with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 6mm thick cement plaster (1:4) in ceiling with coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastrered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 0.9 liter/ 10 sqm)
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size. Size of Tile 600 x 600 mm
Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With commercial grade colour tiles.
Providing and laying Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less then 0.08% and conforming to IS: 15622/ISO 13006 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 Coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc, complete. Size of tiles 600 x600 mm.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Extra for pre finished nosing to treads of steps of marble stone.
Supplying, fitting and fixing M.S. Grill made of 20X6mm M.S. flat/ Square as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the department.)
Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Labour for fabrication, erection, hoisting and fixing in position structural steel work in R.S. joist, channel, angle, tee, flat, plate, latice member, built up compound section in column, girder, stair case, or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths, bolting, welding (machining wherever necessary) with applying a priming coat of red lead paint all complete as per approved drawing, building specification and direction of E/I.
Chequired Plates (5mm Thick)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing two coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick. 150mm wide.
Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Supplying, fitting and fixing good quality, well dressed and will seasoned sal wood work in chaukhats in doors, windows skylights; fanlight and C/W celestial window, openings, including wedge wove all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/I
Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in doors and windows with black board core blended with high quality phenol formal dehydes synthetic resin both side commercial veneered of standard make with oxidised iron fittings such a hinges, tower bolts, handle, cleats and sand block and taxes all complete as per building specification and direction of E/I-
Supplying, fitting and fixing 35mm thick solid core type non-decorative double leaf flush door shutter in doors and windows with black board core blended with high quality phenol formal dehydes synthetic resin both side commercial veneered of standard make with oxidised iron fittings such a hinges, tower bolts, handle, cleats and sand block and taxes all complete as per building specification and direction of E/I-
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick
Providing and fixing 1mm thick PVC rigid foam sheet over w.c.'s door shutter using synthetic rubber based adhesive (Fevicol SR 998 or equivalent).
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box forceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mmthick M.S. sheet with its top surface hacked for proper bonding, top lidshall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mmdia round headed screws, one lock at the corners. Clamp shall be madeof 12 mm dia M.S. bar bent to shape as per standard drawing.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing 7 finishing the top smooth.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
E/W in excavation in foundation trenches in foundation trenches in ordinary soil (vide classification of soil item - B) &disposal of excavated earth obtained to a distance up to 50M including all lift leveling, ramming the foundation trenches removing root of trees, shrubs all complete as per approved design.
Providing, coarse clean sand in filling in foundation trenches/ in plinth including ramming & watering in layers not exceeding 150mm thick with all leads, including cost of materials, labour, royalty & taxes all complete as per building specification & direction of E/I.
Providing designation 75B one brick flat soling joint filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Providing designation 75B brick work in C.M. (1:6) in Foundation and plinth with approved quality of clean coarse sand of F. M. 2 to 2.5 including providing 10 mm thick mortar joints, costs of screening, materials, scaffolding, ranking out joints to 15mm depth curing, taxes & royalty all complete as per building specification & direction of E/I.
Reinforcement cement concrete work in beams, suspended floors, roofs having slope up to 15ⴰ landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforcement cement concrete work in beams, suspended floors, roofs having slope up to 15ⴰ landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landing, balconies and access platform.
Providing Tor steel reinforcement of 10mm dia rods as per approved design and drawing .
Providing 12 mm thick water proof cement plaster (1:3) in CM 1:3 with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound all complete as per building specification & direction of E/I.
Providing 1.5 mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I-
Providing 12 mm thick cement plaster (1:6) with approved quality of clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding, taxes & royalty all complete as per building specification & direction of E/I.
Providing Supplying & fixing of C.I. main holl cover size 500X450mm(wt not less tain 25 kg ) on septic tank etc oll complite as per direction of E/I.
Providing brickbats of 90 mm to 45 mm size of approved quality in the gap between wall of the pit and earth including cost of materials, labours, taxes, royalty, cairrage at site etc all complete as per standard specifications and direction of the E/I.
Supplying materials and labours for constructing inspection chamber of designation class 75-B bricks size 750 mm deep, 600 mm x 450 mm internal dimension having 250 mm wall thickness in cement mortar (1:6) including 12 mm cement plaster (1:4) with punning on side and cement plaster (1:6) with 600 mm x 475 mm G.I. cover with frame (weight not less than 36Kg.) along with earth work in excavation and 80mm thick PCC- (1:3:6) in foundation and refilling all complete as per specification and direction of E/I..
Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I.
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
Providing coarse clean sand in filling in foundation trenches or in plinth including thick with all leads and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted voume)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing .
Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landing, balconies and access platform.
Providing designation 75B work in C.M. (1:6) in foundation with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints of screening materials, scaffolding, ranking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing 12 mm Thk. cement plaster(1:3) with clean course sand of FM-1.5 with floating coat of neat cementin skirting including rounding of junctions with floor, curing, taxes & royalty all complete as per building specification and direction of E/I
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying materials with labours for constructing inspection chamber of designation class 75 B bricks size 750mm deep, 600x 450 mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x475mm G.I. cover with frame (weight not less than 36Kg) alongwith earth work in excavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Cost of Drillind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L.
Cost of Drillind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L.
(b) From 51.00 to 125.00 M below
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Starter D.O.L starter with SS Enclosure with 380/415 Volt coil 5 to 10 HP
Supply fitting and fixing lowering 40 mm dia G.I. collumn pipe - do - do - all complete job as per direction of E/I.
Supplying, fitting and fixing 40 mm high vitreous white glazed earthen ware E W C with "p" trap of Parry Hindustan or any other I.S.S. approved make including supplying & fixing 15 Liters C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telesopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams, 15 mm PVC alkathene pipe 45 cm long with brass coupling at both ends and white / black plastic solid state seal and lead of commander / cuckoo or ther I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over coat of red oxide primer etc. all complete as per specification and direction of E/I. With "P" trap (b) 12.5 lit. low level P.V.C. cistern
supplying fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of hindustan parry or any other approved ISS make with 5lts capacity C.I. automatic fulsing cistern of reliance for any other I.S.S. approved make with all fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400gms , 15mm pvc /Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including paintings of exposed parts with two coats pf approved paint over a priming coat of red oxide, cutting wall and floor , making good the same etc. all complete as per specification and direction of E/I. (a) Flat back or standing corner (600mm X 350mm)
supplying fitting and fixing vitreous white glazed earthen were wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32 mm C.I. brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grams, 32 mm P.V.C. waste pipe 750 mm long with brass coupling at one end and making plumber joints etc. all complete as per sepcification an direction of E/I.
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 510x1040 mm bowl depth 250mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia
Swan Neck Tap with left hand operating knob (ISI Marked)
Pillar Cock (Long Neck) (ISI Marked)
Providing and fixing 15 mm dia and 45 cm long P.V.C connection pipe with heavy quality brass coupling at both ends etc. all complete as per specification and direction of Engineer-in-Charge.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing toilet paper holder : C.P. brass
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. C.P.brass liquid soap container
Providing and laying P.V.C. Pipe for outlet of S&W including all accessories, i.e. lubricants, solvent cement, clamp, ring, sockets etc. 75 mm diameter
Providing and laying P.V.C. Pipe for outlet of S&W including all accessories, i.e. lubricants, solvent cement, clamp, ring, sockets etc. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 75 mm Coupler
110 mm Coupler
75 mm Single pushfit Coupler
110 mm Single pushfit Coupler
75 mm Single tee with door
110 mm Single tee with door
75 mm Single tee without door
110 mm Single tee without door
75 mm Bend 87.5ⴰ
110 mm Bend 87.5ⴰ
75 mm Shoe (Plain)
110 mm Shoe (Plain)
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources
100 mm dia steel Jali
Making khurra 45x45cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm nominal size) over PVC sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete :
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. Coupler 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. Single T with door (110x110x110 mm)
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. 110 mm Bend 87.5°
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on walls ) 25 mm nominal dia Pipes
32 mm nominal dia Pipes
50 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) PN-16 Pipe, 20 mm OD (SDR-7.4)
PN-16 Pipe, 25 mm OD (SDR-7.4)
PN-16 Pipe, 32 mm OD (SDR-7.4)
Providing and fixing ball valve (brass) of approved quality complete : High or low pressure with plastic floats complete: 20 mm nominal bore
25 mm nominal bore
Providing and fixing G.M. non-return valve Horizontal/vertical type of approved quality as per specification and direction of Engineer-in-Charge. 32 mm dia weight not less than 600 gms. ((A) Horizontal non-return valve)
Providing and fixing G.M. non-return valve Horizontal/vertical type of approved quality as per specification and direction of Engineer-in-Charge. 32 mm dia weight not less than 600 gms. ((B) Vertical non-return valve)
Providing and fixing G.M. full way valve of approved quality all complete as per specification and direction of Engineer-in-Charge. 50 mm dia and weight not less than 1.5 Kg
Polythene water storage tank of mark with cover suitable locking system in double layer confirming to IS : 12701-1996 with Latest revision. (2000 Ltr. & 2000 Ltr. Each)
Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kind of soil Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as perstandard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Extra for depth for manholes Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kind of soil Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
Providing and laying Non Pressure NP-2 class (Light duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 250 mm dia.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber : For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as perstandard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) necessary excavation7foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Point wiring in PVC conduit, with modular type switch - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular type switch, modular plate suitable G.I. box etc. as required. Group C
Wiring for twin control point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way with modular type switch, modular plate suitable G.I. box etc. as required.
wiring of following light point with 1.5 sq.mm FRLS PVC insulated copper conductor cable in PVC conduit recessed including chasing of wall, filling of chases with cement mortar 1:3 mix and /or fixing conduit on surface of wall/ceiling including fixing of saddles etc. including modular range of plate switches, modular cover plate, ceiling rose, surface or deep tee, circuit wiring (2x2.5+1x2.5), 1.5 sq.mm FRLS PVC insulated copper earth wire, etc. complete as required. One point controlled by one number 10 Amp MCB (First point)
Looping Point above
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing suitable size GI box on surface or in recess, with suitable size of phenolic lamination sheet cover infront including painting etc. as required 75mm x 75mm x 50mm deep/(4'' x 4'')
Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required 5/6 A, one way switch
15/16 A, one way switch
5/6 A, 3 pin socket outlet
15/16 A, 6 pin socket outlet
Supply & fixing of 20 amps, 240, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top anlong with 20 A "C" curve, TPN, MCB, in sheet enclosed on surface or in recess, with chained metal cover for socket out let and complete with connections, testing and commissioning, etc as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supply & fixing of 25 A, 415 V, TPN industrial type, socket outlet with 4 pole and earth, metal enclosed plug top anlong with 20 A "C" curve, TPN, MCB, in sheet enclosed on surface or in recess, with chained metal cover for socket out let and complete with connections, testing and commissioning, etc as required.
SITC OF 7 W LED 6500 K Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver. MAKE :- Havells
SITC OF 9 W LED 6500 K Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver. MAKE :- Havells
Supply installation testing commissioning of TRIM CLIPON LED PANEL SQUARE 30 W LED 6500 K Make:- Havells Model:-LHEAABP7IN1W024
SITC of 15 W WH LED Bulkhead Light as/Specification,PDC AL Housing,system watage -10 w,Lumen pack - 800 with eficacy - 800lm/w,CRI-80. , IP -65,Surge protection - up to 5 kv with IS 10322 (part 5/Sec.1)-2012.
SITC of 5 W WH LED Mirror Light
Supply installation testing commissioning of 1400 mm fan
Supply installation testing commissioning of 1200 mm fan
450 mm (18') metal body wall fan with speed regulation suitable for single phase 220 V, 50 Hz AC supply
Supply installation testing commissioning of 20W SFTL
SUPPLY OF 500 KVA, 11KV/433 VOLT TRANSFORMER (OIL TYPE) WITH OFF LOAD TAP CHANGER. Design, manufacture, testing at works, supply and delivery, including supervision during installation, testing and commissioning to be carried out of 500 KVA, 11KV/415V outdoor type Transformer (oil type) with OFF Load Tap Changer as specified in the Technical specifications, complete with the following standard, mountings, fittings, accessories, etc as required.The Transformer must confirm to the IS 1180 OR standards specified in the technical specifications. No load voltage Ratio : 11KV / 415 V, No. of Phases / Freq.: 3 Phase/50 Hz., Type : Core type, double copper wound Cooling: ONAN, Vector Group: DYn11, Temperature rise : 50/55 Deg. (oil / winding), On load type tap changer , Taps on HV for HV variation : + 5% to -15% in steps of 1.25% each. Termination (HV): Air Filled cable box suitable for 11KV 3C X 185 Sq.mm Al. Armoured XLPE Cable. Termination (LV): Suitable flange for termination of 2 runs 3.5 x 300 Sq.mm Al. Armoured XLPE Cable. Impedance at 75 Degree celsius : As per IS 1180 Total Loss at Rated load, Voltage & frequency shall be: As per IS 1180 Emergency trip push button on front door . 1 Set Limit switches with 6 NO/ 6 NC breaker auxiliary contacts 1 Set Control:- T-N-C (Trip, Neutral, Close) breaker control switch. 1 Set Space heater with thermostat for moisture absorption. 1Set Suitable for connection to 3 core x 240 sq.mm. Cross linked polythelene (XLPE) 11KV cables or as called for. 1 Set HT Danger Plate 1 Set Hooter low intensity 24 Volt with acknowledge and reset push button 1 Set 6-window microprocessor based annunciation panel with audio and visual indicator. Over current & earth fault - 2 windows Master trip operated - 1 window Spare - 3 windows Surge Arrestor, 10KA, Class II 1 Set Incoming as described above. 1 Set HT Panel as described above (1 No.Incoming cum Outgoing Panel) The transformer shall be supplied with Standard fittings as per specifications including the following : Conservator with drain valve, Magnetic oil level indicator,Silicagel breather with oil seal,First filling of oil as per IS 335 including make up during installation of transformer plus 10% extra oil. To be supplied - in a container, Thermometer pocket with plug, Air release plug, Inspection cover, Top filter brass gate valve - 1 no., Removable Lifting lugs and Jack lifting pad support, Earthing terminals - 2 nos.for body earth and neutral earthing bushing terminal on transformer top cover. Radiator with top and bottom shut off brass gate valves, Rating and Diagram plate., Bi-directional Plain/Flanged Rollers, Drain cum bottom filter valve - 1 no, Explosion vent with double diaphragm and sight glass, Buchholtz relay with shut off valve, 100 mm dial magnetic oil level gauge with max pointer and low level alarm contacts, 150 mm dial oil temperature indicator (OTI) with max pointer and 2 sets of Contact for Alarm & trip, 150 mm dial winding temperature indicator (WTI) with max pointer & 2 sets of contacts for alarm & trip, Magnetic oil level indicator with annunciation, Marshalling box with GLS lamp point and 15A switchsocket oulet point with watertight lockable cover lid. NOTE :- Item shall be suitable for termination of multicore (minimum 6 core 2.5 sq.mm. Copper ) conductor armoured cable connecting between respective equipment to terminal block in marshalling box to annunciation window panel and to main breaker as required. (The Transformer losses shall not be more than maximum allowable losses as per IS Code:1180 ) Transformer described as above.
Unloading, receiving, storing, installation in correct assigned positions, effecting proper connections, testing & commissioning of 11KV 1 breaker panel (1 No. Incoming cum Outgoings) Board as per manufacturers instruction, as per specification and complete as required.
Supply, Installation, testing and commissioning of 100 AH capacity, 24V DC maintenance free SMF Batteries in fully charged condition, including painted MS stand & spill proof plastic trays etc.complete as required as per specifications.
Supply, Installation, Testing & Commissioning of Battery Charger Unit with provisions of "Boost Charging" and "Float Charging", suitable for 240V, single phase, AC, 50Hz supply system & 24V DC including providing required MCB for DC supply distribution to panel complete as required.
Supply and fixing in position the approved "shock treatment charts" framed in teak wood frame and covered with glass in front as required in two languages (Hindi & English)
Supply & fixing of Mimic diagram for overall schematic of power distribution complete as required.
Supply and fixing in position the best quality "Danger Boards" of approved shape and size as specified by Local Electricity Authorities written in English and Local languages. 11KV (250mm X 200mm)
415V (150mm X 100mm)
Supply & Laying of non skid Electro mat 1 mtr wide and 3.0 mm thick 11KV grade conforming to IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.
Supply of fire buckets 5 nos. 15 litre capacity duly filled with fine sand and fixed on an angle iron frame as per requirement of local authorities. The fire buckets shall be painted red from outside and white from inside, including lettered as FIRE with white colour with extra handle at bottom.
Supply & Laying of non skid Electro mat 1mtr wide and 2.0 mm thick 1.1KV grade IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.
Supply of Rubber hand gloves 11KV grade, as per IS 4770-1968.
Supply of standard first aid box as approved by Indian red cross society/ St.John Ambulance Brigade and conforming to IS 2217-1963.
Supply, Receiving, shifting, laying, testing and commissioning of following 1100V grade PVC insulated armoured copper conductor control cables on existing cable tray/ trench as per specifications including of all clamps/ saddles/screw and cable identification tags etc. complete as required including termination of the following sizes of PVC insulated Copper conductor cable including providing terminal lugs,single compression gland , crimping the joints ,providing insulation tape,effecting terminal connections to the equipment.(For HT Panel controls, Transformer Protection, PLC controls. 2C X 2.5sq.mm Cu. Cable
12C X 1.5sq.mm Cu. Cable
10C X 2.5sq.mm Cu. Cable
2C X 1.5sq.mm Cu. Shielded Cable
Supplying, Receiving, shifting, and commissioning of following sizes of 11 KV grade XLPE insulated aluminium conductor armoured power cables conforming to IS : 7098 (Part-II) laid buried in ground / trench / existing Hume pipe / PVC pipe / GI pipe in an approved manner complete as required and as per specifications including excavation of trench in all classes of soil, including supply and provision of sand bed above the cable and below the cable with supply and laying of 1st class brick protection back filling of the trench with excavated earth free from boulders after laying and dressing of the cable in an approved manner complete as required as per IS1255 and as per drawing. 3 core X 185 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. a. Above 120 sq. mm and upto 400 sq. mm
Supply & Installation of 11KV XLPE cable end terminations including termination kit, cable crimping lugs, insulation tape etc. complete as required. 3 core X 185 sq mm (outdoor type)
3 core X 185 sq mm (indoor type)
Supply,installation,testing and commissioning of two pole structure with required arrangement for terminating 11 KV overhead conductor on one side and 11 KV, 3 x 185 sq.mm. Al conductor XLPE cable on the other side including providing triple pole ,mechanically operated mounted on insulators and steel frame with operating mechanism worked from ground level,expulsion fuses of 11 KV ,required rating along with 11 KV 200 amp air break isolator suitable for outdoor application ,earth switch, Metal oxide type Lightning arrester complete with all fittings and discharge capacity 50 KA complete as required.(This structure shall be supplied and installed as per Local Electricity board norms.)
Supply,installation,testing and commissioning of Metering cubicle as per local electric authority norms including providing required CT and PT complete as required.
Providing, erecting and commissioning of Ground Floor Panel (including one I/C- 125 Amp Draw out type 4 Pole MCCB, O/C- 6 no 63 Amp TPN MCB, All MCCBs are 4 Pole & MCB are 2 Pole adjustable current setting type MCCB & MCB) as directed by Engineer In-Inchagre.
Providing, erecting and commissioning of First Floor Panel (including one I/C- 250 Amp Draw out type 4 Pole MCCB, O/C- 6 no 63 Amp TPN MCB, All MCCBs are 4 Pole & MCB are 2 Pole adjustable current setting type MCCB & MCB) as directed by Engineer In-Inchagre.
Providing, erecting and commissioning of Main Distribution Board (MDB) (including one I/C- 100 Amp Draw out type 4 Pole MCCB, O/C- 8 no 32 Amp DP MCB, All MCCBs are 4 Pole & MCB are 2 Pole adjustable current setting type MCCB & MCB) as directed by Engineer In-Inchagre.
Providing, erecting and commissioning of Common Area Panel (including one I/C- 100 Amp Draw out type 4 Pole MCCB, O/C- 8 no 40 Amp TPN MCB, All MCCBs are 4 Pole & MCB are 3 Pole adjustable current setting type MCCB & MCB) as directed by Engineer In-Inchagre.
Supply, receiving, shifitng, testing and commissiong, of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications. 3.5 x 300 sq.mm. Aluminium Cable
3.5 x 150 sq.mm. Aluminium Cable
3.5 x 70 sq.mm. Aluminium Cable
3.5 x 35 sq.mm. Aluminium Cable
4 x 16 sq.mm. Aluminium Cable
4 x 25 sq.mm. Aluminium Cable
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Termination of the following sizes of Al XLPE insulated conductor armoured cable including providing terminal lugs,single compression Brass glands crimping the joints,providing insulation tape, effecting terminal connections to the equipment complete as required. 3.5 x 300 sq.mm. Aluminium Cable
3.5 x 150 sq.mm. Aluminium Cable
3.5 x 70 sq.mm. Aluminium Cable
3.5 x 35 sq.mm. Aluminium Cable
4 x 16 sq.mm. Aluminium Cable
4 x 25 sq.mm. Aluminium Cable
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and laying in position the following GI tape/wires including providing all fixing accessories and effecting proper connections including clamping to wall with suitable clamp / Saddle and fixing bolts / Soldering / rivetting in ground including the cost of digging & back filling as required & complete as required to comply with IS 3043. All joints shall be tinned. 4 mm dia G.I. wire
25 x 5 mm GI tape
50 x 5 mm Cu tape
50 x 5 mm GI tape
32 x 6 mm GI tape
Supply and installation of following sizes of MS perforated type cable trays with stove enamel paint of approved colour and necessary bends, tees, reducer couplers, dashfastners,GI nuts bolts including cutting,bending, drilling, bolting, required suspension arrangement etc. complete as per specifications and as approved by Project Manager. Tray 900 mm wide, 75mm high (2.0 mm thick)
Tray 450 mm wide, 50mm high (2.0 mm thick)
Tray 200 mm wide, 50mm high (2.0 mm thick)
Bends 900 mm wide, 75mm high (2.0 mm thick)
Bends 450 mm wide, 50mm high (2.0 mm thick)
Bends 200 mm wide, 50mm high (1.6 mm thick)
Trees 900 mm wide, 75mm high (2.0 mm thick)
Trees 450 mm wide, 50mm high (2.0 mm thick)
Trees 200 mm wide, 50mm high (2.0 mm thick)
Reducer 900 mm wide, 75mm high (2.0 mm thick)
Reducer 450 mm wide, 50mm high (2.0 mm thick)
Reducer 200 mm wide, 50mm high (2.0 mm thick)
Providing, erecting and commissioning of Common Area Panel (including one I/C- 32 Amp Draw out type 4 Pole MCB, O/C- 15 no 6-32 Amp DP MCB, 3 no 40 Amp DP MCB, All MCB are 2 Pole adjustable current setting type MCB) as directed by Engineer In-Inchagre.
Electrical Manhole Size- 600x600 mm as per standard drawings
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 300 mm diameter
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.)
Providing and fixing water Co2(ISI marked) extinguishers including all accessories as per IS specification with wall bracket with rawl plug. Capacity 9 liters.(IS:15683)
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
Carriage of materials SAND , LEAD - (1K + 10P)
STONE CHIPS , LEAD - (1K +50P)
STEEL LEAD 10 KM
BRICKS , LEAD- = (1K + 60P) KM.
CEMENT LEAD = 3 KM
Add 18 % GST
Add 1% Labour Cess
stage.html
html • 0.02 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.41 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
SBD.pdf
Tender Documents • 9.83 MB
BOQ_148191.xls
BOQ • 0.46 MB
Drawing.pdf
Tender Documents • 4.82 MB
FormofBid.pdf
Tender Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .