Loading…
Loading…
Tender Value
₹3.2 Cr
EMD Value
₹3.2 L
Closing Date
3 Sept 2026, 3:00 pm6d left
Construction of Coimbatore Chapter building located at Door Nos 129-135, Nehru Street, Ramnagar, Coimbatore, Tamilnadu
NBCC/RBG/South/ICMAI/Coimbatore/2026/34
NBCC/RBG/South/ICMAI/Coimbatore/2026/34
Open Tender-Domestic
Civil Works - Buildings
Coimbatore, Tamil Nadu
₹11,800
₹3.2 L
3 Sept 2026
20 Aug 2026
3 Sept 2026
3 Sept 2026
BILL OF QUANTITIES (BOQ) -SUMMERY SHEET
Construction of Coimbatore Chapter building located at Door Nos 129-135, Nehru Street,
Ramnagar, Coimbatore, Tamilnadu
DSR 2023 AMOUNT
DSR- DSR 2025 NDSR
Including correction
S.No.2023/2025/N DESCRIPTION AMOUNT AMOUNT (in
factor @0.973 and
DSR (in Rs) Rs)
COST INDEX @22%
6.00 GRAND TOTAL 32,495,571
6.00 GRAND TOTAL 32,495,571
Digitally signed by DEEPAK
ESTIMATE FOR CIVIL WORKS
DSR ITEM correction NDSR DSR 2023
SL. NO UNIT QUANTITY NDSR AMOUNT
NO factor RATE AMOUNT
SH-2 EXCAVATION WORKS
Earth work in excavation by mechanical means (Hydraulic excavator) /
manual means foundation trenches or drains (not exceeding 1.5 m in
width or 10 sqm on plan), including dressing of sides and ramming of
1 2.8.1 bottoms, for all lift, including getting out the excavated soil and disposal of cum 630 309 194670
surplus excavated soil as directed, within a lead of 50 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking
2 2.26.1 excavated or stacked materials. All kinds of soil cum 360 150.5 54180
Filling available excavated earth (excluding rock) in trenches, plinth, sides
of foundations etc. in layers not exceeding 20cm in depth, consolidating
each deposited layer by ramming and watering, lead up to 50 and for all lift.
3 2.25 All kinds of soil cum 350 232.7 81445
Earthwork is disposal upto 5km By Mechanlcal Transport lncludlng
4 1.1.2 loadlng,unloadlng and stacking sqm 100.00 387.8 38780
Open timbering over areas including strutting, shoring etc. complete.
(Measurements to be taken of the face area timbered): Depth exceeding 3
m but not exceeding 4.5 m
Supplying and filling in plinth with sand under floors, including watering,
6 2.27 ramming consolidating and dressing complete cum 1.00 2521 2521
Supplying chemical emulsion in sealed containers including delivery as
7 2.34 specified
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL
9 2.35 anti-termite treatment (excluding the cost of chemical emulsion) :
Treatment of soil under existing floors using chemical emulsion @ one litre
per hole, 300 mm apart including drilling 12 mm diameter holes and
10 2.35.3 plugging with cement mortar 1 :2 (1cement : 2 Coarse sand) to match the
existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
SH-4 CONCRETE WORK
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering-
Allworkuptoplinthlevel:1:4:8(1Cement:4 coarsesand(zone-III)derived from
12 4.1.8 natural sources :8 graded stoneaggregate 40 mm nominal size derived cum 83.00 8086 671138
from natural sources)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :
3 coarse sand (zone-III) derived from natural sources : 6 graded stone
aggregate 20 mm nominal size derived from natural sources) over 75mm
thick bed of dry brick ballast 40 mm nominal size, well rammed and
13 4.17 consolidated and grouted with fine sand, including necessary excavation, sqm 320.00 889.5 284640
levelling & dressing & finishing the top smooth.
Providing & applying a coat of residual petroleum bitumen of grade of VG-
10 of approved quality using 1.7 kg per square metre on damp proof
14 4.13 course after cleaning the surface with brushes and finally with a piece of sqm 50.00 173.5 8675
cloth lightly soaked in kerosene oil.
Providing and laying cement concrete in retaining walls, return walls, walls
(any thickness) including attached pilasters, columns, piers, abutments,
pillars, posts, struts, buttresses, string or lacing courses, parapets, coping,
bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to
15 4.2.3 floor five level, excluding the cost of centering, shuttering and finishing: cum 14.00 11746 164444
1 :2:4 (1 Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4
graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying damp-proof course 40mm thick with cement
concrete1:2:4 (1cement:2 coarse sand (zone-III):4graded stone aggregate
SH- 5 REINFORCED CEMENT CONCRETE
Digitally signed by DEEPAK
Providing and laying in position ready mixed M-30 grade concrete for reinforced
cement concrete work, using cement content as per approved design mix,
manufactured in fully automatic batching plant and transported to site of work in
transit mixer for all leads, having continuous agitated mixer, manufactured as per
mix design of specified grade for reinforced cement concretProviding and laying
in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement,
admixtures in recommended proportions as per IS: 9103 to accelerate / retard
setting of concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing, carriage for all
leads; but excluding the cost of centering, shuttering, finishing and reinforcement
as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design
mix shall be payable sperately. In case of the cement content in design mix is
more than 1:10 times of the specified minimum cement content , the contractor
shall have discussion to either re-design the mix or bear the cost of extra cement.
Digitally signed by DEEPAK
All works upto plinth level concrete M30 grade with minimum cement
Providing and laying in position ready mixed M-30 grade concrete for reinforced
cement concrete work, using cement content as per approved design mix,
manufactured in fully automatic batching plant and transported to site of work in
transit mixer for all leads, having continuous agitated mixer, manufactured as per
mix design of specified grade for reinforced cement concretProviding and laying
in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement,
admixtures in recommended proportions as per IS: 9103 to accelerate / retard
setting of concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing, carriage for all
18 5.33 leads; but excluding the cost of centering, shuttering, finishing and reinforcement
as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design
mix shall be payable sperately. In case of the cement content in design mix is
more than 1:10 times of the specified minimum cement content , the contractor
shall have discussion to either re-design the mix or bear the cost of extra cement.
All works above plinth level upto floor V level concrete M30 grade with
5.33.2.2 minimum cement content of 350kg/cum 260 11884 3089840
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi
tracks/ runways, using cement content as per design mix, using coarse sand and
graded stone aggregate of 40 mm nominal size in appropriate proportions as per
approved & specified design criteria,
providing dowel bars with sleeve/ tie bars wherever required, laying at site,
spreading and compacting mechanically by using needle and surface vibrators,
levelling to required slope/camber, finishing with required texture, including steel
form work with sturdy M.S. channel sections, curing, making provision for
contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm
19 16.43 deep) by groove cutting machine, providing and filling joints with approved joint
filler and sealants, complete all as per direction of Engineer-in-charge (Item of
joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:-
Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as
per design mix is payable/ recoverable separately.
Cement concrete prepared with batch mixing machine
Centering and shuttering including strutting, propping etc. and removal of form for
a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete sqm 140.00 65170
Walls (any thickness) including attached pilasters, butteresses, plinth and string
c 5.9.3 Suspended floors, roofs, landings, balconies and access platform sqm 895.00 985395
d 5.9.4 Shelves (Cast in situ) sqm 2.00 2202
e 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 1005.00 878571
f 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 380.00 433580
g 5.9.7 Stairs, (excluding landings) except spiral-staircases sqm 25.00 22700
h 5.9.16.1 Edges of slabs and breaks in floors and walls - Under 20 cm wide metre 260.00 64376
i 5.9.19 Weather shed, Chajjas, corbels etc., including edges sqm 33.00 37257
Steel reinforcement for R.C.C. work including straightening, cutting, bending,
placing in position and binding all complete up to plinth level and above plinth
21 5.22A.6 level. Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 55000.00 127.1 6990500
Digitally signed by DEEPAK
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C.
22 5.30 projections. metre 480.00 44673.6
SH-6 BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class
23 6.1.2 designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 cum 2.00 16932
coarse sand) 8466
Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level in all shapes
24 6.4.2 and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) cum 150.00 1621350
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level. Cement
25 6.13.2 mortar 1:4 (1 cement :4 coarse sand) sqm 63.00 84042
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every
26 6.15 third course of half brick masonry. sqm 63.00 7837.2
SH-8 CLADDING WORK
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineer-
in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement
27 8.31 mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ sqm 250.00 1505 376250
3.3kg per sqm, including pointing in white cement mixed with pigment of
matching shade complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills,
facias and similar locations of required size, approved shade, colour and texture
laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints
treated with white cement, mixed with matching pigment, epoxy touch ups,
28 8.2 including rubbing, curing, moulding and polishing of edges to give high gloss
finish etc. complete at all levels.
Area of slab over 0.50 sqm
SH-9 UPVC AND FRP WORK
Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of
lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required)
extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2
profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any
shape, colour and design duly reinforced with galvanized mild steel section made of
required shape & size as per CPWD Specification, uPVC extruded glazing beads,
interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM
gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head,
comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as
per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws
etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion
welded/mechanically jointed duly sealed at all corners, including drilling of holes for
fixing hardware and drainage of water etc. After fixing frame the gap between frame and
adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of
approved size and quality, all complete as per approved drawing conforming to CPWD
specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross
29 9.147.A sections of uPVC profiles to be as per design approved by Engineer-in-Charge Wire
mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high
performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231
shall be paid separately.
Note:- Structural design proof checked from a Government Engineering Institute, to be
provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS
(ii) Sites with structure height more than 20m for all wind speeds
Three track panels sliding door wit hAluminium channel for roller track,wool
pile,zincalloy(zamak) powder coated handle on two panels along with multi-point
locking system,adjustable nylon rollers with SS 304 body. Using R3 series with
9.147.B4.1 frame(98mm&above)x(40mm&above)& sach(30mm&above)x(74 mm & above). sqm 112.00 9837 1101744
(Height upto 2.5 metre).
Providing wood work in frames of doors, windows, clerestory windows and other
frames, wrought framed and fixed in position with hold fast lugs or with dash
30 9.1.1 fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for cum 0.64 169690 108601.60
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain
in gloss / matt/ suede finish with high density protective surface layer and reverse
31 9.127.2 side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of sqm 32.00 1065.15 34084.8
adhesive of approved quality 1.0 mm thick
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with
10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete
32 9.53 block 300x100x150mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone No 206.00 271.66 55961.96
aggregate 20mm nominal size).
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating
33 9.97 not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour 0
or shade, with necessary screws etc. complete :
Digitally signed by DEEPAK
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not
less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or
shade, with necessary grade AC 10 as per IS : 1868) transparent or dyed to
34 9.100.1 required colour or shade, with necessary screws etc. complete : No 22.00 78.64 1730.08
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to
35 9.101.2 required colour and shade, with necessary screws etc. complete. Twin rubber No 22.00 85.88 1889.36
Providing and fixing aluminium extruded section body tubular type universal
hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the
36 9.84 body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), No 22.00 1167.06 25675.32
with double speed adjustment with necessary accessories and screws etc. complete
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-
section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter
of 30 mm thickness. The laminate shall be moulded with fire resistant grade
unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm
34 9.121 thick and shall be filled with suitable wooden block in all the three legs. The frame metre 73.00 677.75 49475.75
shall be covered with fiber glass from all sides. M.S. stay shall be provided at the
bottom to steady the frame.
Providing and fixing to existing door frames.30 mm thick Glass Fibre Reinforced
Plastic (FRP) panelled door shutter of required colour and approved brand and
manufacture, made with fire - retardant grade unsaturated polyester resin, moulded
to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden
38 9.122.1 frame and suitable blocks of seasoned wood inside at required places for fixing of sqm 21.00 4416.75 92751.75
fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming
to IS: 14856, including fixing to frames.
SH-10 STEEL WORK
Steel work welded in built up sections/ framed work, including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer using
37 10.25.2 structural steel etc. required. In gratings, frames, guard bar, ladder, railings, Kg 300.00 204.89 61467
brackets, gates and similar works
Providing and fixing in position collapsible steel shutters with vertical channels
20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and
bottom rail of T-iron 40x40x6mm, with 40 mm dia steel pulleys, complete with
38 10.3 bolts, nuts, locking arrangement, stoppers,handles, including applying a priming sqm 4.58 13579.5 62194.11
coat of approved steel primer
Providing and fixing M.S. grills of required pattern in frames of windows etc. with
M.S. flats,square or round bars etc. including priming coat with approved steel
39 9.48.2 primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc Kg 500.00 282.94 141470
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle
iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings
complete, including applying a priming coat of approved steel primer. Using M.S.
40 10.5.1 angels 40x40x6 mm for diagonal braces sqm 2.00 6890.11 13780.22
SH-11 FLOORING WORK
Providing and laying flamed finish Granite stone flooring in required design and
patterns,in linear as well as curvilinear portions of the building all complete as per
the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick
base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement
slurry and pointing with white cement slurry admixed with pigment of matching
41 11.55.1 shade including rubbing, curing and polishing etc. all complete as specified and as sqm 2.00 3782.8 7565.6
directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black,
Cherry Red, Elite Brown, Cat Eye or equivalent
Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS:15622, of approved brand & manufacturer, in all colours and
shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing
with grey cement slurry @3.3 kg/sqm including grouting the joints with white
cement and matching pigments etc. The tiles must be cut with the zero chipping
diamond cutter only . Laying of tiles will be done with the notch trowel, plier,
wedge, clips of required thickness, leveling system and rubber mallet for placing
the tiles gently and easily.
11.41A.1.3 Double charge vitrified tile polished finish of size 600 x 1200 mm sqm 350.00 1872.17 655259.5
Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS:15622, of approved brand & manufacturer, in all colours and
shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing
with grey cement slurry @3.3 kg/sqm including grouting the joints with white
cement and matching pigments etc. The tiles must be cut with the zero chipping
43 11.41A.3.1 diamond cutter only . Laying of tiles will be done with the notch trowel, plier, sqm 55.00 1738.86 95637.3
wedge, clips of required thickness, leveling system and rubber mallet for placing
the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size
Digitally signed by DEEPAK
Providing and laying 60mm thick faciory made cement concrete interlocking paver
block of M -30 grade made by block making machine with strong vibratory
compaction, of approved size,design & shape, laid in required colour and pattern
over and including 50mm thick compacted bed of coarse sand, filling the joints
44 16.68 with line sand etc. all complete as per the direction of Engineer-in-charge. sqm 380.00 1152.64 438003.2
SH-13 FINISHING WORK
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
46 13.4.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) sqm 776.00 424.2 329179.2
20 mm cement plaster 1:2 (1 cement : 2 stone dust).
Distempering with 1st quality acrylic distemper (ready mixed) having VOC
content less than 50 gram/litre, of approved manufacturer and of required shade
13.41 and colour all complete to achieve even shade and colour :
New work (two or more coats) over and including water thinnable priming coat
48 13.41.1 with cement primer having VOC content less than 50 gram/litre sqm 1242.00 220.38 273711.96
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone
additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10
49 13.47.1 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm 776.00 203.11 157613.36
Providing and applying white cement based putty of average thickness 1 mm, of
approved brand and manufacturer, over the plastered wall surface to prepare the
50 13.80 surface even and smooth complete sqm 1242.00 185.24 230068.08
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two
or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @
51 13.48.3 0.80 ltr/10 sqm of approved brand and manufacture sqm 35 202.63 7092.05
SH-12 FALSE CEILING WORK
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm
in true horizontal level, suspended on inter locking metal grid of hot dipped
galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive)
consisting of main “T” runner with suitably spaced joints to get required length
and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200
mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick
(minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to
center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm
and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at
middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of
size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid
including, required cutting/making, opening for services like diffusers, grills, light
fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from
ceiling using GI slotted cleats of size 27 x 37x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with
52 12.52.1 galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center sqm 150.00 2258.92 338838
to center along main T, bottom exposed width of 24 mm of all T-sections shall be
pre-painted with polyester paint, all complete for all heights as per specifications,
drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in plain
Tegular edge Global white colour tiles of size 595x595 mm,and 0.5 mm thick with
8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides
inclusive) and electro statically polyester powder coated of thickness 60 microns
(minimum), including factory painted after bending.
NDSR WATER PROOFING WORK
Providing and applying water proofing treatment by the in house application wing
of the manufactuer or skilled project applicator to the water retaining structures -
Internal surface (potable water tanks) in 2 coats of two-component, solvent-free,
thixotropic, non-sag polyurethane coating, Priming the surface with PU primer at
200 grams/Sqm, followed by the application of waterproof coating should be
applied in two coats by roller only @ 1.5 kg/sq.m. (0.75 kg/sq.m. in 1st coat and
remaining in 2nd coat). Gap between the two coats application shall not exceed 12
hours. The coating shall have solids content of 100%, Elongation of 100% &
Tensile Strength >12Mpa as per ASTM D412, Hardness >40 as per ASTM D
2240, Hydrostatic Pressure resistance of 5bar as per EN12390, Adhesion to
concrete >1.5Mpa as per ASTM D7234 and Water Absorption <0.5 % as per
ASTM D570, Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA for
potable water contact all as per manufacturers' specification, etc, complete.
53 The system includes base preparation of cleaning, brushing and removal of flacky sqm 70.00 1450 101,500.00
materials, grouting the porous area with cementitious grout, sealing the minor
cracks, fix the Corner Joint tape at the corners when the first coat is still in wet
condition ad apply one additional coat at corner.
Note: This is a stand alone system and screed/plaster protection is not
required.High strength PU Waterproofing For Potable Water Tanks - Inside
(OHT/Raw Water Tank Etc.) Above 50KL
Digitally signed by DEEPAK
Providing and applying two component high performance polymer modifed
cementitious waterproofing coating, having minimum elongation of 200%, Tensile
strength 1.5 N/mm2 (As per ASTM D412), Adhesion Strength 1.2 Mpa (As per
ASTM D 7234), Crack bridging up to 2mm (As per ASTM C836) and food grade
certification by CFTRI, including reinforcing the coating with 45gsm glass fibre
mesh at all corners. The coating shall be applied with a total consumption of
2.2Kg/Sqm in two coats to achieve 1.2mm thickness. The coating shall be
continued to the entire horizontal area and should be terminated at 300mm above
FFL over the vertical surface as per manufacturers specification and methodology.
The system includes base preparation of cleaning, brushing and removal of flacky
54 materials, grouting the porous area with cementitious grout, sealing the minor sqm 130.00 585 76,050.00
cracks, proper coving of 50mm x 50mm between slab and wall junctions and pre-
wetting the surface to attain SSD condition before application of the waterproofing
coating, followed by the application of waterproof coating.TOILETS/ BALCONY/
UTILITY WATERPROOFING - Sunken slab
Providing and Applying two component elastomeric Polyurethane based cold
applied seamless waterproofing coating, to the RCC surface like Roof & Podium
area applied @ 2.1kgs/sqm in single coat using 3mm notched trowel to achieve
1.5mm DFT, including a prime coat of two component solvent free, medium
viscous, epoxy primer @0.2litre/sqm. The Waterproofing material shall have
Solids >98%, Tensile strength >6MPa, Elongation at break >600% as per ASTM D
412, crack bridging ability (no cracks up to 3.2mm) confirms to ASTM C 1305,
Puncture resistance >300N as per ASTM E154, Shore A Hardness >70 as per ASTM
D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N.
Resistance to root penetration. Waterproofing coating shall be applied on the
entire horizontal surface extending upto 300mm above FFL over the vertical
55 surface. The finished cost to include surface preparation, making coving of 50 sqm 430.00 1450 623,500.00
mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and
lay 40gsm Geo-textile over the angle fillet when the first coat in still wet,
treatment of cracks completely as per specification.Newly Constructed
Roof/Podium with 2K Polyurethane Waterproof coating
Clean the surface, removing the laitance with wire brushing and water pressure jet
wash. Fill the cracks using a fibre reinforced crack filler, Crack-X range as per
TDS. Apply one coat of Efflorescence resistant penetrating primer, dilute with
water in the ratio 2:1 spreading at the rate of 0.125litre/sqm in the SSD condition
and allow it to cure for 4-6 hours (primer required only for fresh plaster surface).
Apply one coats of UV Resistant acrylic Waterproof Coating without any dilution
Maintain the spreading rate of 4.20 - 4.70 Sq.mt / litre / coat application to achieve
about 100-120 microns DFT. Apply second coat of UV Resistant acrylate Top
Coat with interval of 6 - 8 hours without any dilution spreading at rate of 6.0 - 6.5
Sq.mt / per litre / coat to achieve DFT of 60 – 70 microns. The material having
56 following technical properties: Attains hairline crack bridging up to 2 mm, sqm 776.00 345 267,720.00
Elongation of >100 % as per ASTMD 412; Tensile strength 2.50 Mpa per ASTM
D 412, Passes Water Resistance as per SS500 standard, Complies to anti
carbonation test as per EN 1062 part 6. External wall waterproof coating
Providing angle Fillet for Sunshade:
Apply one coat of SBR Latex bond coat by mixing URP with cement at a 1:1
ratio. Providing Minimum 75mm x 75mm thick angle fillet with CM of 1:3
57 admixed with SBR Latex at a dosage of 12-15% of Cement.Waterproofing sqm 53.00 125 6,625.00
Treatment for Sunshade on top of Plaster
SH-19 DRAINAGE WORK
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter
C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement
concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm
59 19.15.1 nominal size) as per standard design : With 20x20 mm square bar No 10.00 646.59 6465.9
SH-23 BORE WELL
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable
method prescribed in IS: 2800 (part I), including collecting samples from different
strata, preparing and submitting strata chart/ bore log, including hire & running
charges of all equipments, tools, plants & machineries required for the job, all
complete as per direction of Engineer-in-charge, upto 90 metre depth below
All type of soil - 350mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well,
unplasticized PVC medium well casing (RMS) pipe of required dia, conforming to
IS: 12818, including required hire and labour charges, fittings & accessories etc.
61 23.4 all complete, for all depths, as per direction of Engineer -in-charge.
150mm nominal size dia
Digitally signed by DEEPAK
`Gravel packing in tubewell construction in accordance with IS: 4097, including
62 23.8 providing gravel fine/ medium/ coarse, in required grading & sizes as per actual cum 10.00 2403.2 24032
requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to
establish maximum rate of usable water yield without sand content (beyond
permissible limit), with required capacity air compressor, running the compressor
for required time till well is fully developed, measuring yield of well by "V" notch
method or any other approved method, measuring static level & draw down etc. by
step draw down method, collecting water samples & getting tested in approved
laboratory, i/c disinfection of tubewell, all complete, including hire & labour
charges of air compressor, tools & accessories etc., all as per requirement and
direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to
the top of bore well housing/casing pipe, removable as per requirement, all
64 23.13 complete for bore of:
Providing and fixing M.S. clamp of requried dia to the top of casing/housing pipe
of tubewell as per IS:2800 (Part I), including necessary bolts & nuts requred size
65 23.14 complete.
Providing and fixing Bail plug/Bottom plug of required dia to the bottom of pipe
assembly of tubwell as per IS:2800 including necessary bolts & nuts of required
66 23.15 size complete.
BORE WELL INSTALLATIONS (NON-SCHEDULED ITEMS)
Supplying & Installation of suitable Hp submersible pump with cable 1x3x2.5
squmm(upto 75mtr) with flexible conduit 25mm dia, electrical out door pannel
with required electrical fitting such as MCB of 0-25Amp , Volt & Ampere meter ,
single phase preventer starter etc of approved make, 40mm HDPE Pipe (25 mtr) each 1.00 44339.4 44,339.40
and all accessories complete as per requirement of site.
a) Contractor shall include the rate of electrical control panels complete with all
accessories &controls, all Electrical/Mechanical items as required to operate the
67 NDSR system automatic/manual.
b) Contractor to select suitable HP of pumps .
c) Level Controller with sufficient nos. of low / high level alarms, contacts with
electrodes and control wiring for the automatic operation of water supply pumps,
Submersible Sump Pumps, to achieve the functional requirement shall be
provided. Control wiring between these pumps and water tanks shall be
provided.Domestic water pumps must start at low water level in overhead
domestic water tank & stop at high level in that water tank. Dry running protection
shall be provided for all the pumps.Sequencing shall be provided for each set of
pumps. complete as per direction of EIC.
Digitally signed by DEEPAK
BOQ Plumbing Work
Rate (INR) Amount (INR)
DSR Item RATE inc
S.No. DESCRIPTION OF ITEM UNIT QUANTITY NDSR
No./NDSR correction NDSR DSR-2023
SH-17 INTERNAL PLUMBING WORKS
Providing and fixing rimless wall mounted water closet P trap with soft close seat cover Each
1 NDSR and concealed flushing cistern with dual flush fittings (6/3L flush) including nuts, bolts 9 25735.00 231615.00
etc complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing Stainless steel with powder coating Half frame including rag bolts
2 NDSR and accessories for fixing concealed flushing cistern and water closet in position including 9 3717.00 33453.00
cutting walls and making good the same as directed by the engineer in charge.
Supplying and fixing white glazed European water closet, wash basin 510x400 mm,
600x100 hinged hand rail-1 nos, 600mm long grab bars-4 nos and all associated
3 NDSR accessories like flushing cistern, raised seat and cover, CP brass elbow operated pillar tap , 2 65782.00 131564.00
waste coupling etc. to make the toilet functional for special need persons including cutting
and making good the walls and floor, etc. complete.
Supplying and fixing 560x400x205mm or nearest size Oval shape wash hand basin of
white glazed earthenware (Indian make best quality) counter sunk already built with
4 NDSR necessary chipping and chamfering and finishing including supplying and fixing C P brass 5 19714.00 98570.00
waste, deck mounted sensor pillar tap. including cutting and making good the walls,
providing brackets for supports etc. complete.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm
C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting
5 NDSR and making good the walls wherever require: 5 15889.00 79445.00
White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P.
brass pillar tap
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste
fittings complete.
17.28.2 Flexible Pipe
Providing and fixing bevelled edge 6mm mirror of superior glass (of approved quality) Each
7 17.31 complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass 8 1908.73 15269.87
screws and washers complete.
Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with
8 17.10 C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets,
cutting and making good the walls wherrerever required.
17.10.2.2 Kitchen sink without drain board Size 610x460 mm bowl depth 200 mm Each 3 4598.43 13795.30
Providing and fixing white vitreous china battery based infrared sensor operated urinal of
approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml
consumption), having water inlet from back side, including fixing to wall with suitable
brackets all as per manufacturers specification and direction of Engineer - in-charge.
Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm
deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width
10 8.10 with chase cutter and embedding the stone in the chase with epoxy grout or with cement
concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per
direction of Engineer-in-charge and finished smooth.
8.10.2 Granite Stone of approved shade Each 8 4809.79 38478.31
CP Brass fittings
11 18.21 Providing and fixing unplasticised PVC connection pipe with brass unions.
18.21.2 45 cm length
18.21.2.1 15 mm nominal bore Each 10 116.04 1160.35
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with Each
12 NDSR S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as 11 1963.00 21593.00
approved by Engineer - in - charge.(Health Faucet).
Digitally signed by DEEPAK
13 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
18.49.1 a) 15 mm nominal bore Each 11 601.60 6617.62
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved
quality conforming to IS:8931 .
18.53.1 a) 15 mm nominal bore Each 21 681.73 14316.30
Supply and fixing CP brass sink cock (Wall mounted) with long swivel spout and wall Each
flange in position.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved
make conforming to IS:8931:
18.52.1 15mm nominal bore Each 6 795.86 4775.19
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as Each
per the direction of Engineer-in-charge. .
Providing and fixing SS liquid soap container 109 mm wide, 125 mm high and 112 mm Each
18 NDSR distance from wall of standard shape with bracket of the same materials with snap fittings 8 2118.00 16944.00
of approved quality and colour, weighing not less than 105 gms..
Providing and fixing SS towel rail complete with brackets fixed to wooden cleats with CP
brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 600 mm, 78 mm wide and effective height of Each
88 mm, weighing not less than 170 gms..
20 NDSR Providing and fixing SS towel ring Each 3 1201.00 3603.00
21 NDSR Providing and Fixing double coat hook. Each 11 937.00 10307.00
UPVC WASTE & VENT PIPES AND FITTINGS
Supply and fixing SWR Type B sanitary concealed pipes and specials , jointing with
solvent cement and fixing them on slabs, floors etc. in position for connecting various
fixtures (including fixing of pipes in sleeves/ drilled holes before water proofing) and
specials with brick or CC supports wherever necessary including cutting and chasing
brick walls as required, making good the same with brick in CM 1:6 and plastering with
CM 1:4, 12mm thick one coat, sealing joints between pipe and concrete, complete
Supply , jointing and fixing SWR type B Sanitary exposed pipes, specials and pipe
supports with good quality solvent cement and teflon tape and fixing the same to line,
23 NDSR plumb and level on the sides of ducts, walls, suspended to slabs as the case may be by
using slotted rails , U clamps, 8mm threaded rods and other required materials including
drilling holes, making good the walls, cleaning etc. and finishing complete
24 NDSR Supplying and fixing PVC multi Floor Trap 100mmx75mm size without Jali in position 15 242.00 3630.00
Providing and fixing SS grating of approved quality. Rectangular type with openable Each
25 NDSR circular lid : 150 mm nominal size square 100 mm diameter of the inner hinged round 15 203.00 3045.00
Providing and fixing stainless steel floor clean-out/maintenance access cover of approved
make, grade SS 304, with stainless steel frame and removable cover, suitable for
26 NDSR connection to the UPVC SWR drainage system, of size and configuration as required, 8 426.00 3408.00
including necessary adaptor/socket, gasket/seal, screws/fasteners, fixing and sealing,
making good the floor finish.
Providing and fixing multi-floor trap of approved make, suitable for connection to the
urinal waste outlets complete with water seal and a stainless steel maintenance/clean-out
access cover with frame, fixed over the multi-floor trap and accessible from finished floor
level for cleaning and maintenance. The cover shall be of SS 304 grade, with suitable
frame, removable cover and fixing arrangement, including necessary connectors, adaptors,
gaskets, seals and other accessories, properly jointed and fixed in position, including
cutting, drilling, chasing, making good, sealing and testing, complete as directed by the
Engineer-in-Charge.
28 NDSR Providing and fixing PVC vent cowl
INTERNAL RAIN WATER DRAINAGE WORK
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to
29 12.41 IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm
gap for thermal expansion.
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for
unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including
jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
12.42.1 Coupler
31 12.42.5.2 Bend 87.5 degree
Digitally signed by DEEPAK
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter EACH
and weighing not less than 440 grams.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over
33 12.22 PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 6 354.04 2124.24
coarse sand) and a coat of neat cement,punning,rounding the edges and making and
finishing the outlet complete.
INTERNAL WATER SUPPLY WORKS
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c
34 fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings
with one step CPVC solvent cement and the cost of cutting chases and making good the
same including testiang of joints complete as per direction of Engineer in Charge.
Concealed work including cutting chases and making good the walls etc.
18.8.2 20mm dia nominal outer dia pipes Mtr 75 638.16 47862.26
18.8.3 25mm dia nominal outer dia pipes Mtr 80 744.58 59566.67
18.8.4 32mm dia nominal outer dia pipes Mtr 25 877.59 21939.84
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and testing of joints complete as per direction
of Engineer in Charge.
Internal work - Exposed on wall
18.7.3 25mm dia nominal bore Mtr 40 476.66 19066.56
18.7.4 32mm dia nominal bore Mtr 35 615.79 21552.56
18.7.5 40mm dia nominal bore Mtr 45 834.44 37549.97
18.7.6 50mm dia nominal bore Mtr 15 1108.89 16633.38
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply including all CPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching,
refilling & testing of joints complete as per direction of Engineer in Charge.External work
18.9.3 25mm dia nominal bore Mtr 35 421.88 14765.80
37 18.17 Providing and fixing gun metal gate valve with wheel of approved quality.
18.17.1 25mm dia nominal bore each 2 738.83 1477.65
18.17.2 32mm dia nominal bore each 3 818.60 2455.79
18.17.3 40mm dia nominal bore each 2 980.63 1961.26
18.17.4 50mm dia nominal bore each 2 1218.70 2437.39
38 NDSR Providing and fixing CI Y type strainer of approved quality (Flanged end) :
a) 40mm dia nominal bore each 2 5597.00 11194.00
b) 50mm dia nominal bore each 2 8294.00 16588.00
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS :
39 18.48 12701 marked, with cover and suitable locking arrangement and making necessary holes
for inlet, outlet and overflow pipes but without fittings and the base support for tank.
a) 10000L Tank for fire Ltr 10000 13.06 130600.00
b) 2500L tank for domestic & flushing Ltr 2500 13.06 32650.00
SH-18 EXTERNAL PLUMBING WORKS
Supply and Laying SWR Type B pipes, lowering into trenches, placing in position,
aligning to line and levels and jointing with solvent cement including earth work
excavation in all classes of soil, refilling the trenches and transporting excess soil as
recommended by the site engineer, complete. (For sewer lines).
c) 75 mm. dia. metre 10 875.00
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC
top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal
size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate
41 19.7 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3
coarse sand) finished with floating coat fo neat cement and making channels in cement
concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size)
finished with a floating coat of neat cement complete as per standard design.
Inside size 90x80cms and 45cms deep including CI cover with frame (light duty)
19.7.1 455x610mm internal diamensions total weight of cover and frame to be not less than 38
kg (weight of cover 23 kg and weight of frame 15kg).
With common burnt clay FPS (non modular) bricks of class designation 75
42 19.8.1.1 Extra for depth for manholes:
Size 90x80cm with With common burnt clay FPS (non modular) bricks of class metre
designation 7.5
Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty)
43 19.7.2 455x610mm internal diamensions total weight of cover and frame to be not less than 116
kg (weight of cover 58 kg and weight of frame 58kg).
With common burnt clay FPS (non modular) bricks of class designation 75
44 19.8.2.1 Extra for depth for manholes:
Size 90x120cm with With common burnt clay FPS (non modular) bricks of class metre
designation 7.5
Providing and fixing Square- mouth SW gully trap class SP-1 Complete with CI Grating
brick masonry chamber with water tight CI Cover with frame of 300 X 300mm size
(inside) the weight of cover to be not less than 4.50kg and frame to be not less than 2.70kg
as per standard design.
Digitally signed by DEEPAK
100 x 100 mm size P type with common burnt clay F.P.S(non modular) brick of class each
designation 7.5
150 x 100 mm size P type with common burnt clay F.P.S(non modular) brick of class each
designation 7.5
SH-19 SITC PUMP
Supply, Erection, Testing and Commissioning of Open well submersible pump (Transfer
pump) set capable of lifting 70 lpm of water against a total head of 25m - 2 nos (1 working
and other standby) with accessories such as 40mm non return valve - 2nos, 40mm full
46 NDSR way wheel valve - 2nos, pump panel having MCB, digital diaplay of voltage and current, set 1.00 57750.00 57750.00
Indicating lamps, manual switches, digital function capable of dry run prevention and
automatic interchange system all enclosed within a single panel
(Approximately 1HP, Filling time 25min) complete in all respect.
Supply, erection, testing and commissioning of Pressure Booster pump capable of
delivering 100Lpm discharge at a head of 2.5Bar (1 working only), the system shall be
47 NDSR capable of automatic start and stop operation and complete with Hydro tank of 60L Nos 1.00 63454.00 63454.00
capacity, dry run preventor, pressure sensors, pressure gauge, pump panel, necessary
cabling and bypass arrangements, with skid etc. complete in all respect.
Total Carried over to summary 849967.91 1143603.00
Digitally signed by DEEPAK
ELECTRICAL WORKS
Rate (INR) Amount (INR)
Sl No Item Description Unit Qty
No/NDSR DSR-2025 NDSR DSR 2025 NDSR
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in
surface/ recessed medium class PVC conduit, with modular switch,
1 1.1 modular plate, suitable GI box and earthing the point with 1.5 sq.mm
FRLS/HFFR PVC insulated copper conductor single core cable etc. as
Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC
insulated copper conductor single core cable in surface / recessed medium
class PVC conduit, 2way modular switch, modular plate, suitable GI box
2 1.11 and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper
conductor single core cable etc. as required.
Wiring for circuit/ sub main wiring along with earth wire with the following
sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in
3 1.14 surface/ recessed medium class PVC conduit as required.
c 1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire m 100 373 37300
Supplying and fixing of following sizes of medium class PVC conduit along
with accessories in surface/recess including cutting the wall and making
4 1.21 good the same in case of recessed conduit as required..
Supplying and fixing metal box of following sizes nominal size) on surface
or in recess with suitable size of phenolic laminated sheet cover in front
5 1.22 including painting etc. as required.
Supplying and fixing following modular switch/ socket on the existing
modular plate & switch box including connections but excluding modular
6 1.24 plate etc. as required.
b 1.24.5 6 pin 15/16 A socket outlet Each 20 721 14420
Supplying and fixing modular blanking plate on the
existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box along with modular
base & cover plate for modular switches in recess etc. as required.
a 1.27.1 1 or 2 Module (75mmX75mm) Each 40 354 14160
Supplying and fixing following Modular base & cover plate on existing
modular metal boxes etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in
front on surface or in recess, including providing and fixing 3 pin 5/6 A
10 1.31 modular socket outlet and 5/6 A modular switch, connections etc. as
required. Each 90 545 49050
Supplying and fixing suitable size GI box with modular plate and cover in
front on surface or in recess, including providing and fixing 6 pin 5/6 &
11 1.32 15/16 A modular socket outlet and 15/16 A modular switch, connections
etc. as required. Each 40 659 26360
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/
wooden block including connections etc. as required. Each 25 104 2600
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm
thick steel conduit, aluminium cast back plate and brass holder complete,
13 1.36 including wiring the down rod with 1.5 sq. mm FRLS/HFFR PVC insulated,
copper conductor, single core cable and painting etc. as required.
Digitally signed by DEEPAK
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V,
complete as required. Each 1 112 112
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15
mm dia, heavy gauge including painting etc. as required. (Note : More than
15 1.48 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall
be ignored) Each 80 59 4720
Installation, Testing and Commissioning of exhaust fan in the existing
16 1.50 opening, including making good the damage, connection, testing,
commissioning etc. as required.
a 1.50.1 Upto 450 mm sweep Each 1 556 556
Wiring for group controlled (looped) light point/fan point/exhaust fan point/
call bell point (without independent switch etc.) with 1.5 sq. mm
FRLS/HFFR PVC insulated copper conductor single core cable in surface/
17 1.55 recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR
PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc.
as required. Each 15 132 1980
Providing and fixing following rating and breaking capacity and pole MCCB
with thermomagnetic release and terminal spreaders in existing cubicle
19 2.2 panel board including drilling holes in cubicle panel, making connections,
Ics=100% Icu and Operational Voltage 690V etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel,
MCB distribution board, 240 V, on surface/ recess, complete with tinned
20 2.3 copper bus bar, neutral bus bar, earth bar, din bar, interconnections,
powder painted including earthing etc. as required. (But without
MCB/RCCB/Isolator)
a 2.3.2 8 way , Double door Each 2 2773 5546
Supplying and fixing following way, horizontal type three pole and neutral,
sheet steel, MCB distribution board, 415 V, on surface/ recess, complete
21 2.4 with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But
without MCB/RCCB/Isolator).
a 2.4.2 6 way , Double door Each 4 5299 21196
Supplying and fixing of following ways surface/ recess mounting, vertical
type, 415 V, TPN MCB distribution board of sheet steel, dust protected,
duly powder painted, inclusive of 200 A tinned copper bus bar, common
22 2.5 neutral link, earth bar, din bar for mounting MCBs (but without MCBs and
incomer ) as required. (Note : Vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
a 2.5.1 4 way , Double door Each 2 7951 15902
b 2.5.2 8 way , Double door Each 1 10724 10724
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve,
miniature circuit breaker suitable for inductive load of following poles in the
23 2.10 existing MCB DB complete with connections, testing and commissioning
etc. as required.
3 2.10.1 Single pole Each 40 285 11400
b 2.10.3 Double pole Each 2 696 1392
c 2.10.4 Triple pole Each 15 1070 16050
d 2.10.5 Triple pole and Neutral Each 8 1301 10408
Supplying and fixing single pole blanking plate in the existing MCB DB
complete etc. as required. Each 30 14 420
Supplying and fixing following rating, double pole, (single phase and
neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity
25 2.14 current 30 mA in the existing MCB DB complete with connections, testing
and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral),
415 volts, residual current circuit breaker (RCCB), having a sensitivity
26 2.15 current 30 mA in the existing MCB DB complete with connections, testing
and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along
27 2.16 with 25/32 A 240 V "C" curve DP MCB complete with connections, testing
and commissioning etc. as required. Each 3 1258 3774
Supplying and fixing TP sheet steel enclosure on surface/ recess along
28 2.17 with 16/25/32 A 415 V "C" curve TP MCB complete with connections,
testing and commissioning etc. as required. Each 3 1707 5121
Supplying and installing following size of perforated Hot Dipped Galvanised
Iron cable tray (Galvanisation thickness not less than 50 microns) with
perforation not more than 17.5%, in convenient sections, joined with
29 4.6 onnectors, suspended from the ceiling with two numbers GI Suspenders i/c
base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
a 4.6.4 300 mm width X 50 mm depth X 1.6 mm thickness m 150 1062 159300
Digitally signed by DEEPAK
Supplying and installing following size of perforated Hot Dipped Galvanised
Iron cable tray "bends" (galvanisation not less than 50 microns) with
perforation not more than 17.5%, in convenient sections, joined with
30 4.7 connectors, suspended from the ceiling with two numbers GI Suspenders
i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
a 4.7.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 20 1977 39540
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
accessories, and providing masonry enclosure with cover plate having
31 5.4 locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/
coke and salt as required. Set 4 8351 33404
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground
as strip earth electrode, including connection/ terminating with G.I. nut,
32 5.9 bolt, spring, washer etc. as required. (Jointing shall be done by overlapping
and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from
33 5.11 earth electrode including connection with G.I. nut, bolt, spring, washer
excavation and re-filling etc. as required. m 100 755 75500
Providing and laying earth connection from earth electrode with 6 SWG dia
G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection
34 5.12 with G.I. thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for
connections etc. as required. m 200 287 57400
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop
earthing as required. m 150 84 12600
Supplying, installation, Testing & Commissioning of LED Recessed/surface
LED Down lighter SMD Type (Round/ square/ Rectangular) SMD type of
following body material with PMMA and prismatic diffuser and construction
as per IS : 10322 with driver as per the requirement with Driver efficiency
>85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating
temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV
with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI
37 8.2 >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below
5 %), life time (LED, Driver & electrical circuitry), life time of minimum
50000 Burning Hours with 70% of initial Lumen maintained till life ends,
CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),
SDCM(Standard Deviation Color Matching) <3,
Maximum power consumption should not more than the specified rating
and Fixture shall be of relevant BIS standard. Manufactures Word Mark/
Name Engraved/ Embossing/ Screen printing on housing Complete in all
respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC
insulated copper conductor single core cable and earthing etc. as required
with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135
lm/Watt output . LM79 & LM80 Test report and all testing required for LED
fixtures as per BIS shall be submitted.. Shape size
and CCT shall be as approved by Engineer-in- Charge as per requirement.
(Thermal management: heat sink of aluminium housing such that LED
junction temperature shall not rise above 90°C). Powder coated die cast
/Extruded aluminium Body including trim .
Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of
following body material and construction as per IS : 10322 with driver as
per the requirement with Driver efficiency >85%, Operating voltage AC
140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C,
internal surge protection of 2.5 KV with Short & Open circuit
protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare
38 8.7 Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED,
Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70%
of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K
/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)
Maximum power consumption should not more than the specified rating
and Fixture shall be of relevant BIS standard. Manufactures Word Mark/
Name Engraved/ Embossing/ Screen printing on housing. complete in all
respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC
insulated copper conductor single core cable and earthing etc. as required
with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135
lm/Watt output .LM79 & LM80 Test report and all testing required for LED
fixtures as per BIS shall be submitted. Shape size and CCT shall be as
approved by Engineer-in-Charge as per requirement. (Thermal
management: heat sink of aluminium housing such that LED junction
temperature shall not rise above 90°C). Powder coated die cast / Extruded
aluminium Body (Thickness > 1.20 mm)
Supplying, installation, Testing & Commissioning of LED surface mounted
Batten light of following body material and construction as per IS : 10322
with driver (Replaceable) as per the requirement with Driver efficiency
>85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating
temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short &
39 8.10 Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker
free (flicker should be below 5 %), life time (LED,Driver & electrical
circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen
maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K
Digitally signed by DEEPAK
(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3,
Maximum power consumption should not more than the specified rating
and Fixture shall be of relevant BIS standard. Manufactures Word Mark/
Name Engraved/ Embossing/ Screen printing on housing. complete in all
respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC
insulated copper conductor single core cable and earthing etc. as required
with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135
lm/Watt output . LM79 & LM80 Test report and all testing required for LED
fixtures as per BIS shall be submitted. Shape size and CCT shall be as
approved by Engineer-in-Charge as per requirement. (Thermal
management: heat sink of aluminium housing such that LED junction
temperature shall not rise above 90°C). Powder coated die cast /Extruded
aluminium Body (Thickness > 1.20 mm)
Supplying, Installation, Testing & Commissioning of LED Flood Light,
powder coated pressure die cast aluminium body with built in or separate
driver as per the requirement with Driver efficiency >85%, Input voltage:
Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range
-5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-
40 8.16 4-5, Driver efficiency >85%,THD < 0% as per IEC 61000-3-2, P. F.≥0.95,
IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC
as per CISPR-15, lenses for beam angle 30 deg-120deg as per the
application and the project requirement, suitable tilt able fitting,
life time (LED, Driver & electrical circuitry) of minimum 50000 Burning
Hours with 70% of initial Lumen maintained till life ends as per LM80
extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K
/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)
<5, Maximum power consumption should not more than the specified rating
and Fixture shall be of relevant BIS standard complete in all respect i/c
external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper
conductor single core cable and earthing etc. as required with Minimum 5
year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt
output . LM79 & LM80 Test report and all testing required for LED fixtures
as per BIS shall be submitted.. Shape size and CCT shall be as approved
by Engineer-in-Charge as per requirement. (Thermal management: heat
sink of aluminium housing such that LED junction temperature shall not
rise above 90°C).
Supply, Installation, Testing and Commissioning of ceiling fan with Remote,
Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.
metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,
shackle kit, safety rope, copper winding, steel/Al body. Power Factor not
less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM
(tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than
10%, remote (preferably mobile app based) for speed control and all
41 9.1 remaining accessories including safety pin, nut bolts, washers, temperature
rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable
for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS
374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC
insulated copper conductor single core cable and earthing etc. as required.
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min
Laying of one number PVC insulated and PVC sheathed / XLPE power
42 10.5 cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL
pipe as required.
b 10.5.2 Above 35 sq. mm and upto 95 sq. mm m 30 72 2160
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE
43 10.7 power cable of 1.1 KV grade of following size on wall surface as required.
a 10.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle) m 20 64 1280
Above 35 sq. mm and upto 95 sq. mm (clamped with
b 10.7.2 25x3mm MS flat clamp) m 10 151 1510
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE
44 10.8 power cable of 1.1 KV grade of following size on cable tray as required.
a 10.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) m 200 53 10600
Above 35 sq. mm and upto 95 sq. mm (clamped with
25x3mm MS flat clamp) m 10 109 1090
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick
G.I. plate with inscription there on, bolted / welded to 35 mm X 35 mm X 6
45 10.10 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and making end termination with brass compression gland and
aluminium lugs for following size of PVC insulated and PVC sheathed /
46 11.1 XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along
with all accessories like socket, bend, couplers etc. conforming to IS
14930, Part II complete with fitting and cutting, jointing etc.direct in ground
47 15.16 (75 cm below ground level) including excavation and refilling the trench but
excluding sand cushioning and protective covering etc., complete as
Digitally signed by DEEPAK
a 15.16.2 90 mm dia (OD-90 mm & ID-76 mm nominal) m 100 336 33600
Outdoor 4MP_ Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor
Bullet Camera having following specifications and features etc :- 1) Signal System:
PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date &
Time in live & recorded video 2)Image Sensor: 1/2.8" or better progressive Scan CMOS
get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON,
0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with
auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance
upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s
electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light
Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression
(Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4)
Wide Dynamic Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D)
On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream:
4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps 7) Image Setting:
Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client
software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 285 DELHI
SCHEDULE OF RATES (E&M)-2025 8) Cyber Security: AES 256-bit Encryption,
Configuration encryption, trusted execution, Digest, security logs, account lockout, video
40.4.1 encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should 10 10063 100630
support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with
minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite,
storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering
detection; network disconnection detection; IP conflict detection; memory card state
detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP,
NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP,
SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open
source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x
Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.
16) Power Input: The camera should support simultaneous dual power input—12 VDC (via
power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a
failure in one power source. 17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE
18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating
Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-
condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or
better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 40.4.1 4MP @
25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens
(as per site requirement) Nos
16 Channel Network Video Recorder (NVR) having display split :- Main screen:
Supplying, Installation, Testing and Commissioning following capacity Serveillance grade
40.12.1 Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 1 13943 13943
inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM,
UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 40.12.1 4TB (Terabytes) Each 13943.00 NOs
Supplying, Installation, Testing and Commissioning of following size LED display (LED
monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth
42.4 and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or
better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing
angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on
monitor screen and programmable with remote (remote shall be supplied with system),
Key Board, Optical Mouse, etc. as required.
42.4.2 42 inch or larger NOs 1 51459 51459
Supplying, installation, Testing & Commissioning of following capacity
Three phase input and Three phase Output at full load (Unity Power
Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%,
Online double conversion true sine wave Uninterrupted hot swapable
(allow for the replacement or addition of battery modules without shutting
down the entire system) modular Power Supply (UPS) system with N+1
modules (N denotes total number of modules required for rated capacity).
The UPS shall include a Rectifier, inverter, battery bank suitable for 30
minutes back up (Battery VAH capacity shall not be less than 1600 VAH
48 26.2 per KVA of UPS rating per Hour backup time) on full load (Battery shall be
VRLA, SMF in ABS Container) and Static Bypass switch along with manual
bypass, suitable isolation transformer for additional protection against
neutral faults etc. UPS shall have inbuilt phase sequence correction. The
UPS systems offered are to be of the latest technology with Digital Control
Microprocessor based for reliable operation using Insulated Gate Bipolar
Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM
(Pulse Width Modulation).
The quality of design, manufacturing and inspection process should
confirm to the relevant Inter-national standards such as IEC/EN/VDE. The
operating efficiency of the UPS systems shall be >96% while operating on
battery mode and delivering quality power to the 100% non-linear loads.
Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50
%load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be
included in UPS cost), extreme power factor kit to be included to limit the
input power factor (PF) to 0.99 and output power factor shall be unity (i.e.
kw rating of the UPS shall be kva rating x 1 ), however UPS shall be
suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS
shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5
Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload
capacity of 120% for 10 mins, Sine wave output.
Non condensing, noise level less than 60db at 1 meter distance,
protections: Input Under voltage over voltage, abnormal out voltage,
battery over charging, output over current, short circuit protection, battery
deep discharge protection, 10KV surge. UPS must comply with low voltage
electromagnetic compatibility (EMC) achieved as
per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and
Frequency Independent (VFI)-type UPS. Communication
RS232/RS485/SNMP port open protocol for BMS integration, all hardware
& software for iOT Communication as per approved by Engineering in
charge. Required battery racks and interconnecting copper conductor
cables of suitable size and connectors and all required accessories are
inclusive of the cost). This system must provide a means for logging and
alarming of all monitored points plus email notification. Forced air-cooling
with integral inbuilt fans with redundancy (if one fan fail UPS should be
able to handle at least 80% of the load, Noise Level 65 DB at 1 meter
distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242
and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more
LC Display / LED) to display : a) Input: Voltage, current, Frequency. b)
Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d)
Digitally signed by DEEPAK
e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g)
Event Logging & Statistical Data (On LCD/LED): UPS should capture and
display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail /
Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier
Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers
to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery
Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging
and discharging, overload, battery voltage and battery capacity. j) Audible
Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault,
Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery
Over, Under Voltage, Over Load and short circuit, Over Temperature. The
UPS should have QR code which should contain drawing, test report OEM
manual, Geo- Tag of manufacturing location etc
a 15.16.2 10KVA (Each Power module shall be < 10 KVA) Each 1 208893 208893
Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel
Generating set as per CPCB IV + or better norms along with having Prime
Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power
factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor,
including testing at factory and site with fuel, load for test and other
49 29.1 necessary arrangements Complete as per CPWD specifications, should
have QR code which should contain drawing, test report OEM
manual,Geo- Tag of manufacturing location, rating plate as per relevant IS
Code etc. and consisting of the followings:
(A) Diesel Engine:
Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder,
dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM
suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter
MSL , capable of taking 10% over loading for one hour after 12 hours of
continuous operation. The engine will be with Electronic governor, Dry type
Air filter with service indicator, first filling of engine fuel (after
commissioning) lubricating Oil, Coolant and other consumables complete
with all the required accessories, the Electronic governor shall be as per
ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV +
or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS
13018 and as per CPWD specifications.
(B) Engine mounted Instrument Panel fitted with and having digital dis
Plate for following:
(i) Start-stop switch with key
(ii) Water temperature indication
(iii) Lubrication oil pressure indication
(iv) Lubrication oil temperature indication
(v) Battery charging indication and Voltage indication
(vi) RPM indication
(vii) Over speed indication
(viii) Low lubricantion Oil trip indication
(ix) Engine Running Hours indication
(C) Alternator:
Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM,
3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH
& at 1000 Meter MSL. The alternator shall be having Screen Protected Drip
Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically
balanced rotor, capable of taking 10% over loading for one hour after 12
hours of continuous operation, self cooled,self-excited and self-regulated
through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for
tropical conditions and with class- H insulation.
(D) Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame
made of MS channel with necessary reinforcement which shall be installed
on suitable cement concrete foundation and vibration isolation
arrangement as per recommendations of manufacturer.
Daily service fuel tank of suitable liters capacity as per PWD
Specifications, fabricated out of 3 mm thick M.S. sheet complete with all
standard accessories and fuel piping between fuel tank and diesel engine
with MS class ‘C’ pipes of suitable dia. Complete with valves, level
indications & accessories as required as per specifications.
(F) Exhaust System:
Dry exhaust manifold with hospital type exhaust silencer and catalytic
(G) Starting System:
12V/24V DC starting system comprising of starter motors: voltage regulator
and arrangement for initial excitation complete with suitable numbers of
batteries (180 AH capacity lead acid SMF type) as required as per
specifications. The battery shall be housed inside the acoustic enclosure of
(H) Acoustic and weather proof enclosure with arrangement for fresh air
intake for cooling of the engine & alternator, extraction, discharging hot air
in to the atmosphere and the temperature rise inside the enclosure, noise
level outside enclosure. The acoustic enclosure should be suitable for
cable connection/connection through bus-trunking. Such arrangements on
acoustic enclosure should be water proof & dust-proof conforming to IP-65
protection. The enclosure shall be as per CPCB IV + or better norms etc.
and as per CPWD specifications.
Digitally signed by DEEPAK
Free standing floor mounted IP 42 automatic mains failure control panel
including auto by-pass, suitable for KVA as below for silent type DG set
complete with relays, timers, set of CTs for metering & protection and
energy analyser to indicate currents, phase and line voltages, frequency,
power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase
& Total), KW & provision for overload, short circuit, restricted earth fault,
under frequency, power (aluminium) and control (copper ) cabling of
suitable size upto 15 meter between AMF panel, LT Panel and DG Set
including connection interconnection etc. as required, all complete and
inter locking and communication/ Ethernet /RS485/SNMP port open
protocol for BMS integration including suitable software, the panel shall be
of DG Set OEM make etc. as per approved by Engineering in charge and
including the following:
1. Suitable numbers and appropriate capacity 4 pole motorised electrically
operated draw out with cradle type 3 position ACB/ MCCB with electronic
release for O/C & E/F and shunt trip or MCCB with electronic release for
O/C & E/F and shunt trip with 4 Pole Power Contactor.
2. Auto/Manual/Test/Off selector switch 3. Protection for under and over
voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power
relay and 2 Nos. under voltage relay).
4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15
VA class-I for metering
5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA
(Phase & Total), Frequency, KWH, PF.
6. LED Indicating lamps for load on mains and load on set
7. Fuse/ MCB for instruments
8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and
ammeter, selector switch for trickle, off and boost and current adjustment.
9. Main supply failure monitor
10. Supply failure timer
11. Restoration timer
12. Control unit with three impulse automatic engine start/stop and failure
to start lockout.
13. Impulse counter with locking and reset facility.
14. ON/OFF/Control circuit switch with indicator
15. Audio/Video annunciation for
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start
(v) Full load/maximum load warning
16. Protection for over/under Frequency, Loss of AC sensing, Over
Current, Unbalancing load with suitable number of relays and accessories
17. Maintenance notification based on Engine Run Hour & due date.
18. Load Management through PLC to achieve auto opening and closing of
incomer breakers, bus coupler switching of essential panel , interlocking
providing signal to AMF Panel for load status and AMF shall give command
to DG Set to auto start / auto stop depending upon load status and
requirement etc. and necessary hardware and software required to perform
the operation shall be provided by the contractor including all control
32.20 HI - WALL SPLIT SYSTEMS
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall
split type Air conditioners complete with Indoor unit(IDU), Out door unit
(ODU), surface / concealed copper Refrigerant piping with insulation
(closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr IDU
to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-
32/R-410/ R-407 Green Refrigerant, wireless remote control, suitable for
working between 180-260V with low & high voltage cutoff and 50 hz ,1
phase AC supply capable of performing cooling, dehumidification, air
circulation of following capacity with Scroll / rotary compressor. The system
shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year
Original Equipment Manufacturer (OEM) warranty both compressor and
Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS
9968 temperature sensing control IS /International Electrotechnical
Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger
IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD
specification and IS : 1391 Part II 2023. The system shall be able to
operate up to 50 0C (out door ambient temperature). Inverter Type -
32.2.3 1.5 TR with 5 Star BEE Rating Each 5 43539 217695
Digitally signed by DEEPAK
Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room
less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works
(Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for
barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India -
2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and
as under including all other equipment and accessories complete as required:- (i) Speed-1 MPS (ii)
Floors-3 (G+2) (iii) Travel -10Meters (approx.) (iv) Stops & opening- 3 stops and 3 openings (v)
Controller: A.C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete
with dry maintenance free batteries as required. vii) Operation: Microprocessor based single
automatic push button/simplex selective collective/duplex collective selective with/without
attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system (ix) Car Enclosure: Stainless
steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel
decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth
and antiskid as approved by engineer-in-charge. (xi) Type of doors (a) Car: Power operated, centre
opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish).
NDSR (b) Landing doors: stainless steel scratch proof . (xii) A hand rail not less that 600mm long at
900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii)Voice
announcement system in the car to announce the position of the elevator in the hoist way as the
car passes or stops at floor served by the elevator. (xiv) Closed loop Control System, protection
against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload
detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings,
BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car
door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable
NVR and HDD for 30 days storage
backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan
and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable
persons with hearing impairment to signal for help or assistance in the event of an emergency.
(xvi) An appropriate technological support be provided (Through emergency messaging |services
or alarms etc.) to respond to the emergency requirements of person with hearing impairment or
deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue
Supplying and fixing of following ways surface/ recess mounting, vertical
type, 415 V, TPN MCCB distribution board of sheet steel, dust protected,
duly powder painted, IP43 as per IS 8623 III, impact resistance IK09,
50 NDSR inclusive of required tinned copper bus bar, common neutral link, earth bar,
din bar for mounting MCBs (but without MCBs and incomer ) as required.
(Note : Vertical type MCCB TPDB is normally used where 3 phase outlets
a 8 way , Double door Each 1 23396 23396
Supply of PVC insulated and PVC sheathed armoured underground
51 NDSR aluminium power cable of 1.1KV grade with ISI mark.
Supply, installation, testing and commisioning of AC Single phase Exhaust
52 NDSR fan 300mm sweep light duty, metal / plastic blade, MS / Fibre grill with all
required accessories. Each 3 1886 5658
Supply, installation, testing and commisioningof AC Single phase Wall
53 NDSR mounted fan 400mm sweep, metal / plastic aerodynamic blade with all
required accessories. Each 3 3237 9711
Supply, installation, testing and commisioningof the following rating, 415
V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of
54 NDSR following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.
a 40A / 63A TP MCB Each 2 1500 3000
b 40A / 63A TPN MCB Each 2 1942 3884
Total Amount in Rs 2,807,962.00 1,517,899.00
Total Amount in Rs 2,807,962.00 1,517,899.00
Digitally signed by DEEPAK
Rate (INR) Amount (INR)
S.No. DESCRIPTION OF ITEM UNIT QUANTITY
DSR-2025 NDSR DSR-2025 NDSR
SH-28 Fire Alarm Work
Supplying, installation, testing & commissioning of main
control and indicating panel made out of 16 SWG MS sheet
to accommodate the following items duly powder coated in
approved colour with louvers for ventilation, locking
arrangement, audio and visual indication for fire alarm system, monitoring system
including connections, interconnections etc complete as required.
4 Zone panel for fire alarm system button for operation on 230V AC/24 V DC supply
conforming to IEC-268 for simplex mode of operation/communication Annoucement
1 28.1.10 control desk suitable for selection of different zones selectively and ON ALL CALL NOS 1 75,339.00 75,339.00
switch with visual indication etc. complete as required -1 set. Battery charger trickle cum
boost to take complete load of fire alarm system complete with all accessories including
providing & fixing of 2 nos.12 volt, 7 AH each sealed maintenance free batteries -1 set.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall
speakers complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in
3 28.5.3 the existing surface / recessed steel conduit of following pairs, cores and size including
connections and interconnections etc. as required.
28.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm Mtr 50 61.00 3,050.00
Supplying, installation, testing & commissioning of manual call boxes of MS
4 28.1.3 construction in surface/recess with stainless steel chain & hammer assembly complete NOS 4 513.00 2,052.00
with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make
announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for
operation with amplifier i/c line matching transformer etc. complete as
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with
annealed copper conductor having glass mica fire barrier tape covered by an extruded
layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner
bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying and fixing of following sizes of steel conduit along with accessories in
7 1.20.2 surface/recess including painting in case of surface conduit, or cutting the wall and Metre 250 289.00 72,250.00
making good the same in case of recessed conduit as required.-25 mm dia
SH-27 Fire Fighting Work
(a) Supplying, installation, testing and commissioning of electric driven terrace pump
conforming to IS 12469: 2019 suitable for automatic operation and consisting of
following, complete in all respects, as required: (Terrace Pump)
(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze
impeller with stainless steel shaft, mechanical seal as required.
(c)Suitable HP squirell cage induction motor TEFC type suitable for operation on 415
volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal
foot mounted type with Class
8 27.4.2 'F' insulation, conforming to IS-12615: 2018.
(d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as
(e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Supply, installation, testing, and commissioning of a Fully Automatic Star-Delta Starter
suitable for a 12.5 HP (9.3 kW) 3-phase, 415V, 50Hz motor. The unit shall be enclosed in
9 NDSR a dust and vermin-proof powder-coated CRCA sheet steel enclosure complete in all EACH 1 18000 18,000.00
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming
to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges,
tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable
10 27.7.7 clamp/support frame and painting with two or more coats of synthetic enamel paint of
required shade complete as required :
Supplying and fixing single headed internal hydrant valve with instantaneous
Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked
11 27.9 conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as
27.9.1 Single headed Gunmetal EACH 4 8208 32,832.00
Digitally signed by DEEPAK
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal
12 27.18 diameter size nozzle conforming to IS 903 suitable for instantaneous connection to
interconnect hose pipe coupling as required:
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and
13 27.16 female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office
red, conforming to IS 884 complete with the following as required.
(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as
14 27.17 (b) 20 mm nominal internal dia gun metal globe valve & nozzle.
(c) Drum and brackets for fixing the equipmets on wall.
(d)Connections from riser with 25 mm dia stop gunmetal valve & M.S. Pipe and socket.
Supply and fixing of Fire hose box fabricated out of G.I. Sheet and frame, door shall be
750mm–1000mm width x 600mm height x 250mm depth. & fixed with 4 mm thick Glass,
suitable Rubber beeding and Locking arrangment. Quoted rate shall be included all
15 NDSR fasterners etc, and complete shutter shall be powder coated of approved colour both inside EACH 2 4950.00 - 9,900.00
Supply and fixing of Fire Shaft door fabricated out of G.I. Sheet and frame, door shall be
900mm x 1500mm min with double leaf. & fixed with 4 mm thick Glass, suitable Rubber
16 NDSR beeding and Locking arrangment. Quoted rate shall be included all fasterners etc, and EACH 2 12200.00 - 24,400.00
complete shutter shall be powder coated of approved colour both inside and out side.
17 NDSR Providing/Fixing Fire man axe. Each 4 1,400.00 - 5,600.00
CO2 type Fire exitinguisher ISI marked confirming to IS:15683 lates. Capacity 4.5 kg
complete with delivery hose horn, squeeze grip release valve, locking arrangement,
operating temperature -30°c to +55°c, supplied with body bearing IS 7285 mark and
approved valve as per IS 3224. Co2 Gas as per IS:15222. externally painted with PO Red
18 NDSR Shade No. 538 of IS 5, operation manual and floor stand or wall mount Bracket including - -
accessories as required as per site condition.
Powder Fire exitinguisher (stored Pressure Type) (Powder pressurized with dry nitrogen
gas at 15 bar) capacity 4kg duly ISI marked conforming to IS:15683:2006/latest, with IS
14609 ISI marked ABC powder complete with squeeze grip release valve, discharge pipe,
locking arrangment, pressure gauge, operation maual, Body Hydrotested at 35 bar,
19 NDSR operating temperature--30°c to +55°c, external epoxy powder coating with PO Red shade - -
No. 538 of IS 5, and floor stand or wall mount Bracket including accessories as required
as per site condition.
Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in
height with air release valve on top and flanged connection to riser, drain arrangement
20 27.20 with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and Each 1 19,402.00 19,402.00
painting with synthetic enamel paint of approved shade as required.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male
21 27.19 instantaneous inlet coupling complete with cap and chain as reqd. for suitable dia MS pipe -
connection conforming to IS 904 as required.
27.19.1 2 way-100 mm dia M.S. Pipe EACH 1 7262 7,262.00
Providing, installation, testing and commissioning of non-return valve of following sizes
confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, 5312 complete with
22 27.14 rubber gasket, GI bolts, nuts, washers etc.as required washers etc.as required : -
Providing, installation, testing and commissioning of butter fly valve of following sizes
confirming to IS: 13095 complete with rubber gasket, GI bolts, nuts, complete with rubber
23 27.23 gasket, GI bolts, nuts, washers etc.as required washers etc.as required :
Grand Total Carried over to summary 766975.00 101900.00
Grand Total Carried over to summary 766975.00 101900.00
Digitally signed by DEEPAK
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT- ICMAI.pdf
Tender Document
FINAL BOQ ICMAI.pdf
Tender Document
Tender Drawings ICMAI.pdf
Tender Document
Technical Specification.pdf
Tender Document
List of approved makes-ICMAI.pdf
Tender Document
SCC.pdf
Tender Document
Brief Scope of the work.pdf
Tender Document
Physical_Milestones.pdf
Tender Document
GCC PMC 2026 with Amendments.pdf
Tender Document
SOIL TEST REPORT.pdf
Tender Document
Technical Circulars 1 to 35.pdf
Tender Document
corrigendum-5441-Corrigendum 01.pdf
pdf • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].