| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.5 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹28.9 L+₹94,690.07 (3.38%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹35.5 L+₹7.5 L (27.0%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹38.0 L+₹10.0 L (35.5%)Rejected-Finance | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹40.0 L+₹12.0 L (42.7%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-5 | Rejected-Finance L-5 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
9 Mar 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/REPLACEMENT OF EARTHING PITS, LIGHTENING ARRESTORS, FLAMEPROOF FITTINGS, EXTERNAL ELECTRIFICATION SYSTEM ETC AND REPAIR MAINT OF MES INSTALLATION AT DADRI AF STN IN AOR OF GE (AF) FARIDABAD
2024_MES_640789_1
GE (FBD)/AF-85/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DADRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) FARIDABAD
₹98,000
Yes
30 May 2024
5 Feb 2024
11 Mar 2024
5 Feb 2024
9 Mar 2024
24 Feb 2024
5 Feb 2024 - 9 Feb 2024
Amount
M&L for Earthing complete with galvanised steel earth plate electrode 600mm×600mm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, surrounded from all site by the mixture of charcoal and common salt and electode connected to an including galavnized earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanized steel and GI pipe light grade 20 mm dia bore of watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-1 using 20 mm well graded stone aggregate, incl excavation and earthwork in any type of soil, all as shown in electrical plate No 03 connected to earthing test point all as specified or indicated including testing on completion, complete as specified and directed by Engineer in charge. Note : The unit rate includes for protection pipe and GI wire dia from top of earth plate upto 5 meter above ground level
All as per item No 01 above but with earthing lead 25mm x 4 mm GI strip and GI pipe 25 mm dia.
All as per item No 01 above but using copper plate 600 mm × 600 mm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead and GI pipe 25 mm dia.
M&L and testing for Advance Maintenance Free environment friendly chemical earthing as per IS 3043 with copper strip of size 40 x 6 mm, 3 mtr long, 50mm dia outer pipe of thickness 2mm filled with highly conducting metellic compound in gel foam and boath end sealed, electrolytic copper eathing electrodes. The earth pits shall be filled with sufficent quality ultra high conductive black fill compound with neccessary accessories like lockable pit cover and PVC 16 sqmm single core multistrand PVC insulated copper conductor drawn in HDPE pipe bore 25mm Including test point terminal block made of gun metal phosphorus bronze of size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws and Hot dip galvanised sheet 2 mm thick box of size 200 x 100 x 100 mm with Hexagonal head screws 125 mm complete as required all as per standard practices and complete all as specified and directed by Engineer-in-Charge. Note: 1. The concrete pit shall be PCC 1:3:6 type C1, 40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm aggregate reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in liew of cost iron cover shown in the electrical plate No. 3 MES SSR Part - I 2 The work shall be executed through the approved manufacturer. 3. 2nd earthing shall only be extecuted after approval of 1st earthing.
S & F in replacement of Earthing lead 25mm x 4 mm GI strip including strip insulators complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engineer-in-Charge.
Dismantling & taking down old, deteriorated, lightening, arrestor and supply and fixing litghtening arrestor expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amp suitable for 11000 Volts complete all as specified and directed by Engineer-in-Charge.
M&L for Point wiring complete with 1.5 sq. mm single core multi stranded copper conductor PVC insulated but unsheathed FRLS cable 1100 volt grade ISI marked drawn througth ERW metalic rigid steel conduit on surface 20mm dia and accessaries like glands, bend ,tees, junction boxes etc. incl. 1.5 Sqmm pvc inulatedand , unsheathed single core copper conductor cable as a earth wire fixed on. surface of wall ceiling ,floor etc for complete all as specified and directed by Engineer-in-Charge. :- (a) One light point / fan point controlled by one one way switch.
S & F in replacment of Flame proof LED tube light 20 amp , single phase complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of flame proof weather proof rotary switch 5 Amp with cable termination box in LM6 in aluminium alloy or cast iron complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for 2 x 1.5 Sqmm cable FRLS Armoured cable complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of for Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Flame proof exhaust fan with louvers of 450 mm sweep 0.25 HP , 1440 RPM , 2350 CFM , single phase complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of flame proof weather proof rotary switch 15 Amp with cable termination box in LM6 in aluminium alloy or cast iron complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of flame proof weather proof switch socket and plug combined in LM6 , 5 Amps rating , 250 Vols , 2 pole and earth complete with cable termination box in aluminium alloyor cast iron complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of flame proof weather proof switch socket and plug combined in LM6 , 16 Amps rating , 250 Vols , 2 pole and earth complete with cable termination box in aluminium alloyor cast iron complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminium point wiring/sub main wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with MS conduit and T/W battern and depositing to MES store yard complete all as specified and directed by Engineer-in-Charge.
BLANK
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of pressed steel terminal box of suitable size with 3 mm thick laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified for following (Color coding to be followed) :- One light/fan point controlled by one switch.
All as per item No 21 above but One socket point on same board with other switches
All as per item No 21 above but One 3 pin 5 Amps socket outlet independent with cables 1.5 sqmm size.
All as per item No 21 above but One bell/buzzer point controlled by one bell push.
All as per item No 21 above but with conductor of size 2.5 Sq mm (nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 1.5 Sq mm PVC insulated stranded copper conductor cable.
M&L for Sub main wiring with two single core, 6 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x4 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Note : Two run of 6 Sqmm cable, One run of 4 Sqmm cable and One run of PCV conduit shall be measured one RM.
M&L for Sub main wiring with two single core, 4 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x 2.5 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Note : Two run of 4 Sqmm cable, One run of 2.5 Sqmm cable and One run of PCV conduit shall be measured one RM.
M&L for switch piano type 5 Amps, single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 6A, 1 module complete all as specified and directed by Engineer-in-Charge.
M&L for switch piano type 15 Amps, single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 16A, 1 module complete all as specified and directed by Engineer-in-Charge.
S&F Bell push 6A 1 module complete all as specified and directed by Engineer-in-Charge.
S&F Modular Bell push 6A 1 module complete all as specified and directed by Engineer-in-Charge.
M & L for socket outlet 5 pin , 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
M&L for socket outlet 2 in 1, 3 pin, 5 and 15 Amps Flush type complete all as specified and directed by Engineer-in-Charge.
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
S & F stepped type electronic fan regulator flush type complete all as specified and directed by Engineer-in-Charge.
S & F Fan step regulator, 120W - 2 module complete all as specified and directed by Engineer-in-Charge.
S & F in replacement lamp holder insulated body threaded deme, with back plate,button/ angular type with sutable for battern fitting complete all as specified and directed by Engineer-in-Charge.
S&F for ceiling rose surface bakelite 65x50mm two to three terminals complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of White cover plate with frame,1 module complete all as specified and directed by Engineer-in-Charge.
All as per item No 42 above but 3 module
All as per item No 42 above but 6 module
All as per item No 42 above but 8 module
S&F in replacement of Metal flush box/ PVC box 1/2 module complete all as specified and directed by Engineer-in-Charge.
All as per item No 46 above but 3 module
All as per item No 46 above but 6/8 module
S&F in repair call bell ding dong type 230 volt single phase complete set inclusive suitable size wire from ceiling rose to calling bell complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Exhaust fan 10"/12" sweep metalic body complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC Exhaust fan 300MM sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose , complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable and tubes wit suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Recess mounted LED Light Fitting 15 Watt pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and incl separate replaceable electronic driver compatible for Analog/DALI Dimming complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Edgelit LED slim panel light fitting 2'x2' 40 watt having powder coated extruded Aluminium body with high quality LGP and PMMA diffuser swparate HPF driver suitbale for Armstrong and grid ceilling 6000 K , including connecting up with twin core twisted flexible copper cable with suitable size complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Electronic drivers suitable to fix Recessed mounted LED Light Fitting 15 Watt round shaped complete all as requred on site for smooth functioning of lights complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Electronic drivers suitable to fix Recessed mounted LED Light Fitting 2'x2' 40Watt 6000 K/5400K completemake and model all as requred on site for smooth functioning of lights complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of MCCB 4 pole 125 Amps 16 kA complete all as specified and directed by Engineer-in-Charge.
S& F in replacement of Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB DB double door Single pole & neutral 8 way with 200 amps rated bus bar complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB DB double door Single pole & neutral 12 way with 200 amps rated bus bar complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of amp rating 240V, SP 5 To 32 AMP 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of amp rating 240V, SPN 40 To 63 AMP 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of Indoor unit & Out door unit of Split type AC of 1.5 tone capacity by taking out the same from existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part and reinstall at the same location and clean water with water pressure gun, greasing of fan , motor , blower etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 64 but split type AC of 2.0 ton
M&L for finding out the leakage the pressure test of the condenser of cooling coil of window type AC/split AC of 1.5 /2.0 ton and dismantling the same for repair the leakage point by brazing/ soldering including charging the gas R-22 and testing the AC to the entire satisfaction of Engineer-in-Charge
M&L for finding out the leakage the pressure test of the condenser of cooling coil of window type AC/split AC of 1.5 /2.0 ton and dismantling the same for repair the leakage point by brazing/ soldering including charging the green R-410/309 etc or equilvent as required on site and testing for satisfactiory working condition as directed by Engineer-in-Charge
M&L in repair for taking out unserviceable sealed unit (compressor) 1.5 ton capacity , single phase, 230 volt of models as existing and replacing the same with new sealed unit (compressor) including necessary modification of the foundation as required to suit the compressor, vacumacation , pressure , testing, leaking, rectification incl gas charging R-22 and testing complete to the entire satisfaction of Engineer-in-Charge
All as per item No 68 above but 2 TR
All as per item No 68 above but suitable for refrigerent R 410a for 1.5 TR
All as per item No 68 above but suitable for refrigerent R 410a for 2 TR
M&L for Removing the split type AC 1.5 ton/ 2 ton capacity working on 230 V single phase /440 Volt 3 phase complete including indoor and out door unit all as directed including making good of all disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for reinstall at any place ( with in the stn )along with out door unit stand at height up to 8 mtr from floor level including replacement of refrigerant tubing upto 7.5 mtrs length and provision of drain pipe and pipe insulation, connecting with existing power socket and testing the unit for smooth functioning all as directed including making good of all disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of PCB card suitable of 1.5/2 ton split AC suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of PCB card suitable of 1.5/2 ton Inverter split AC suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engr-in-Charge
S & F in replacement of Corded remote controller suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engineer-in-Charge.
S & F Start Relay suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engineer-in-Charge.
Supply and replace copper condenser coil assembly complete suitable for 1.5 / 2 ton window/ split type AC incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
Supply and replace evaporator coil assembly complete suitable for 1.5 / 2 ton Window / Split type AC incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
S & F Copper pipe 5 /8" complete with insulation of thickness 10 mm incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
S & F Copper pipe 3 /8" complete with insulation of thickness 10 mm incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
S & F Copper pipe 1 /4" complete with insulation of thickness 10 mm incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
S&F condensing fan motor of capacity suitable for Split AC 1.5/2 Ton testing on load for the entire complete all as specified and directed by Engineer-in-Charge.
S&F in repairs running capacitor of capacity ‘45+5’ MFD, 240 volts, 50 Hz.
All as per item No 84 above but capacity 36 MFD
S&F in repairs blower fan motor of capacity 1/30 HP, 3 speed, single phase complete all as specified and directed by Engineer-in-Charge.
S&F in repair condenser fan motor of capacity 1/20 HP, single phase complete all as specified and directed by Engineer-in-Charge.
S&F in repair starting capacitor of capacity 6 MFD, 40 volt, 50 Hz complete all as specified and directed by Engineer-in-Charge.
S&F in repairs starting capacitor of capacity 100-120 MFD , 440 volts, 50 complete all as specified and directed by Engineer-in-Charge. Hz
S&F in repairs wiring kit for capacity 1.5 ton AC complete all as specified and directed by Engineer-in-Charge.
S&F repair & replacement of 1/30 HP fan blower motor of cooling unit of split AC unit with supper enameled copper wire of suitable gauge wire including replacement of the shaft and bushes and testing on load for the enter complete all as specified and directed by Engineer-in-Charge.
All as per item No 91 above but 1/20 HP condensing fan motor complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of Refrigerator any size at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of capacity 253 Ltr as existing make including charging of refrigerant gas F-134 and testing on full load complete all as specified and directed by Engineer-in-Charge.
All as per item No 94 above but capacity of refrigerator 310 Ltr complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of Deep freezer of size 320 Ltr at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of capacity 320 Ltr as existing make including charging of refrigerant gas F-134 and testing on full load complete all as specified and directed by Engineer-in-Charge.
M & L for servicing of Water cooler of any capacity at existing location by cleaning of condenser, cooling coil, and other components with cooling coil Rinse solution & clean water, greasing of fan, motor including cleaning of storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of complete all as specified and directed by Engineer-in-Charge.
M & L for taking out unserviceable sealed unit (compressor) of water cooler 150/150 Ltrs capacity single phase 230 volt of as existing model and replacing the same with new sealed unit (Compressor ) including necessary modification of the foundation as required to suit the compressor, vacumisation presser testing, leakage rectification, charging of gas R-134 and testing complete to the entire complete all as specified and directed by Engineer-in-Charge.
All as per item No 99 above but compressor as existing model and replacing the same with new sealed unit (Compressor) for water cooler 80/40 Ltr capacity complete all as specified and directed by Engineer-in-Charge.
M&L for Replacement of wiring kit for water cooler of any capacity complete all as specified and directed by Engineer-in-Charge.
M & L for servicing of desert cooler of any capacity at existing location by cleaning of all components components with Rinse solution & clean water, greasing of fan, motor including cleaning of water storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of small parts like PVC water distributer, flexible pipe, plugs etc as required on site complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Desert cooler Pump as per existing capacity complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of desert cooler motor of any make with supper enameled copper wire (Thermal class E) of appropriate size including replacement of gun metal bushed and steel shaft complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of wood wool pad 25mm thick duly winded with the nylon mesh of standard size for 4000 cum/hr capacity desert coolers complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of running cap 4.0 MFD 440 volt complete all as specified and directed by Engineer-in-Charge.
M&L for servicing, repair of Voltage stabilizer of capacity 4/ 5 KVA cleaning , dusting, brushing, checking and rectify electrical conections, and other components complete all as specified and directed by Engineer-in-Charge.
S&F in repairs time delay relay suitable for 4/5 KVA voltage stabilizer complete all as specified and directed by Engineer-in-Charge.
S&F in repirs diode suitable for voltage stabilizer of capacity 4/ 5 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for removing old paint by scraping with sand paper to remove old paint including washing and filling cavities with filler and applying two coats of painting with synthetic enamel paint over a coat of red oxide primer by using spray gun method painting to ceiling fan of 1200mm sweep at site (complete 03 Nos blades, motor (both side) including down rod alongwith, writing MES No/Srl No on the ceiling fans complete all as specified and directed by Engineer-in-Charge.
Supply and fixing capacitor, capacity 2.5 mfd in replacement complete all as specified and directed by Engineer-in-Charge.
Supply and fixing capacitor, capacity 3.15 mfd in replacement complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of burnt ceiling fan motor 1200/1400 mm sweep with super enamelled copper winding wire of suitable guage as per details of any make /model complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of ball bearing of ceiling fan of any size complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of wall mounting fan motor 400 mm sweep with super enamelled copper winding wire of suitable guage as per details details of any make /model complete all as specified and directed by Engineer-in-Charge.
S&F wall mounting fan motor copper wound for 400 mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F wall mounting fan blade for 400 mm sweep complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of Exhaust fan of any size complete all as specified and directed by Engineer-in-Charge.
M&L for Exhaust fan motor vopper wound for 300 mm sweep complete all as specified and directed by Engineer-in-Charge.
M&L for Exhaust fan blade for 300 mm sweep complete all as specified and directed by Engineer-in-Charge.
S & F Heating element 3 KW with thermostat for electrical Back up suitable of solar geyser as existing model complete all as specified and directed by Engineer-in-Charge.
S & F in Replacement of heating element suitable for geysers any type as site requirement ISI mark 2.00 KW Capacity 230 Volts complete all as specified and directed by Engineer-in-Charge.
All as per item No 122 above but 1.50 KW Capacity 230 Volts
S & F in replacement thermostat switch any type suitable for geyser of any size/model complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCCB TPN 63 Amps 16 KA complete all as specified and directed by Engineer-in-Charge.
All as item No 125 above but 100 Amps 16 kA .
All as item No 125 above but 125 Amps 415 Volts 16 kA
Supply & fixing of MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
All as per item No 128 above but TPN 200 Amps 415 volts 36 kA.
All as per item No 128 above but TPN 250 Amps 415 volts 36 kA.
All as per item No 128 above but TPN 400 Amps 415 volts 36 KA.
Supply & Fixing in repair of Four Pole Contactor, 415V AC, 2 NO+NC, 250 Amp complete all as specified and directed by Engineer-in-Charge.
All as per item No 132 above but 160 Amps
S & F in replacement of OFF load Change Over Switch 250 Amps 4 pole 415 Volt complete all as specified and directed by Engineer-in-Charge.
M&L for painting of old LT panels of any size and descreption with two coat anti corrosive synthetic enamelled smoke gray paint or as per existing condition required on site incl rubbing old surface with emery paper complete all as specified and directed by Engineer-in-Charge.
Taking out old UNSV LT UG cable from trench/wall all as per site required any type and size complete all as specified and directed by Engineer-in-Charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3.5 core incl thimbles as required with suitable size of calmps on wall/under trenches etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 138 above but 95 Sq mm 3.5 core
All as per item No 138 above but 70 Sq mm 3.5 core
All as per item No 138 above but 50 Sq mm 3.5 core
All as per item No 138 above but 25 Sq mm 4 core
All as per item No 138 above but 16 Sq mm 4 core
All asper item No 138 above but 10 Sq mm 4 core
M & L for serching fault location of HT/LT UG cable 415 Volt laid in trenches /ducts with the help of eletronic fault locating machine comprising of surge generator pulse ,ECHO fault locator with freqency distance calculator etc incl transportation of machinary from Delhi cantt .Excavation in normal soil starta exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specified and directed by Engineer-in-Charge.
All as per item No 146 above but for cable of size 70 to 95 sq mm
All as per item No 146 above but for cable of size 120 to 150 sq mm
S&F galvanised iron tubing light grade size 40 mm dia for protection of cables or mechanical protection of earth strip laid under plinths/floors, road, paths, culverts, or fixed on walls, or along poles by means of MS clamps with necessary bolts, nuts and washers etc complete all as specified and directed by Engineer-in-Charge.
All asper item No 149 above but size 50 mm dia.
M&L for auguring of holes in true horizontal position under road by means of mechanical rig after doing ultrasound to prevent any damage to existing cable/pipe line coming in route 1.5 Mtr deep and not exceeding 50 Mtrs long incl supply and laying HDPE pipe not less than 100 mm dia complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out all as specified and directed by Engineer-In-Charge.
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and directed by Engineer-in-Charge.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge.
M&L for sub class `B` bricks for cable protection complete all as specified and directed by Engineer-in-Charge.
BLANK
M&L for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes complete all as specified and directed by Engineer-in-Charge.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engineer-in-Charge.
M&L for cross arms (MC 75), bracings, supports, clapms and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat paintincl taking down old unserviceable complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal anagement in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and quipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and quipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC nsulated copper conductor, single core cable in surface/ recessed as required 2x1.5 sq. mm + 1x1.0 sq. mm earth wire complete all as specified and directed by Engineer-in-Charge.
S & F Street light factory fabricated junction box of size 300 x 160 x 250mm made out of 2mmm thick CRCA powder coated sheet, including 63 Amp three phase 4 wire having 4 nos of aluminium busbar including 6 A SP MCB. The box should have auto door lock facility with magnetic look fixed on pole using necessary fixing arrangement such as clamps, nuts, bolts, washers etc complete all as specified and directed by Engineer-in-Charge.
S & F Street light factory fabricated junction box of size 450 x 300 x 250mm made out of 2mmm thick CRCA powder coated sheet, including 63 Amp three phase 4 wire having 4 nos of aluminium busbar including 6 A SP MCB. The box should have auto door lock facility with magnetic look fixed on pole using necessary fixing arrangement such as clamps, nuts, bolts, washers etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of street light bracket to fix the street light fitting made out of suitable dia(40mm) light grade GI pipe 2.0 mtr long suitable for mounting of street light fittings on poles /wall incl provision of two Nos flate iron clamps made out bent to shape of 50x6mm flat iron and fixing nuts and bolts in position including painting with two coats of aluminium paint over a coat of red oxide complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of bus bar chamber 4 Way outdoor type with Digital volt meter, Digital Amp meter, R-Y-B indicating lamps factory made out of CRCA sheet dust & vermin proof , front opening door having locking arrangement totally enclosed weather proof, antirusted powder coated painted including aluminium Bus Bar of 200 Amps rating bus size 45 cm long x 50mm wide x 15mm thick, 440 volts, 3 Phase 4 wire having suitable gap to connect the cables of size upto 95 Sqmm 3.5 core and bus mounted on suitable type of insulators incl coloured insulating sleeve on each complete with bottom removable gland plates for inccomming and out going cables, bus chamber mounted on MS angle stand made of MS angle 50mm x 50 mm x 5 mm and should having minimium 45 Cm gap below bus chamber incl necessary PCC foundation work complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LED Post top fitting 40 Watt 5700 K CCT IP 65 powder coated aluminium die cast and spun aluminium with clear diffuser suitable for landscape lighting inclmaking necessary arrangement for mounting fitting as reqd on site and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LED Bollard light fitting IP 54 powder coated PDC aluminium body with opal diffuser suitable for landscape lighting incl making necessary arrangement for mounting fitting as reqd on site and testing complete all as specified and directed by Engineer-in-Charge.
M&L for LT/HT pole painting two coated anti corrosive synthetic enamelled silver paint as per existing condition incl rubbing old surface with emery paper alternate black and yellow 30 cm wide strip upto 1.5 mtr of pole above ground level and marking pole numbers complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing including repair/replacement of LED driver 230 volt single phase of 45/48 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing including repair/replacement of LED light strip 230 volt single phase of 45/48 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection complete all as specified and directed by Engineer-in-Charge.
BLANK
BLANK
BLANK
BLANK
S&F in replacement of earting lead 32 x 6 mm GI strip complete all as specified and directed by Engineer-in-Charge.
M & L for taking out existing LT panel installed at substation building room out side the substation room includig removal of electric disconnection of all LT cables for repairing , servicing and replacement of LT panels unsv part including complete breakable accesories such as partialy open door , breakable door , Unsv Al bus bar , unsv locking arrangement, repairing of LT Panel legs, welding work , all cable disconnecting items/ T&P items must be included in rate complete all as specified and directed by Engineer-in-Charge.
M & L for re-fixing / Re - Installed of exisiting LT Panel (taking out agaist item No 180) any capacity, any size , any tpye (indoor or outdoor type), (disconnected against item No 180 ) after repairing / servicing including cleaning properly of all parts ,removing dust, carbon deposits etc of connections, making all connections and re-installation of existing LT panel to same location or any other location after painting of LT panel including removing old dust partical,oily porytion by rubbing with sand paper with spary pump, and writing /digital printing, Capacity Descripton, date of installation,etc with complete electrical connection with existing cable complete all as specified and directed by Engg-in-Charge. Note coted rate includes neceassry PCC work , Excavtaion , removal , retruning filling including disconnection and reconnection of cables , for any size any capacity LT Panel complete all as specified and directed by Engineer-in-Charge.
Labour only for taking out from trenches, wall, pole , Pipe, PCC, under ground, etc exsisting cable LT 1100 volt grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size, any core, for seggregation of serviceable cable length ,unserviceable cable length and unuse cable length by meggering or any other suitable and recommended method including disconnection and re-connection of Cables. Removing unserviceable and unuse cable leght from site and keeping aside serviceable for reuse at same location or any other location complete all as specified and directed by Engineer-in-Charge. Note : Earth work will be measured and paid separately under respective item.
M & L for Servicing of OLD/ UNSV -SOLAR street light fitting including servicing and Cleaning of solar panel , Low maintenance tubular battery by filling of Distilled water and first charging including replacement of damaged battery terminals, securing of all electrical wire circuit and connections, reparing of damaged foundation complete system if required or complete all as specified and directed by Engineer-in-Charge. Note:- 1. All type of T & P, Distilled water, control cable upto battery terminal, PCC, ladder & tripod etc required at site will be arranged by the contractor and rates for the same will be deemed to be included in the quoted rate. (Spares required to make functional of solar light shall be measured and paid seperately under relevent items )
Supply only Spares of Solar security light complete all as specified and directed by Engineer-in-Charge.
All as per item No 184 above but Replacement of Solar PV Module 74W( As per existing )
All as per item No 184 above but Replacement of White LED based light source 12W( As per existing )
All as per item No 184 above but Replacement of Driver of solar street Lights( As per existing )
All as per item No 184 above but Replacement of Battery rating of 12V & 100 AH( As per existing )
Supply & fix battery compartment box made up of MS sheet 2mm thick size 150x150x30 CM suitable for battery with MS cover, locking arrangements & fixing accessories with inside weather proof coated & out side Aluminium paint incl writing pole number in black colour paint etc complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Integrated all in one Solar Street light (Inbuit Solar PV module and Lithium battery ) 24 watt, secondary optics, LED driver efficiency>92%, battery type LiFePO-04, IP66, colour temperature 6000K-6500K , 140 Lumens per watt Auto On/Off, overcharging protection incl taking down old unser and complete fixing and connection complete all as specified and directed by Engineer-in-Charge.
M&L for Chemical earthing , Design development supply commissioning and testing EHCC certified ground terminal earthing system hollow tube solid bar CCPRI tested for sensitive signal/Electrical equipments highly anti corrosive long life severe wear conditions in the earth pit and of standard size ISI marked copper tube out side secondary conductor of 50mm dia and main primary conductor inside 25mm dia 3000mm length ready to install with suitable connecting terminal confirming to IS:3043 1987 specification highly conducive packing material to be filled in earth pits for providing uniform low resistivity anti corrosive hygroscopic medium around the earth system for improving the efficency of current dissipation 20 Kg per bag (3 bag per kit) min or sufficeient quantities required as per site complete incl PCC pits of inside dimension 0.5x0.5x0.5m and suitable cover complete all as specified and directed by Engineer-in-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead/strip upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 mtr are measured and paid separately.
Supply and fixing in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required Copper Strip 20x3 mm complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with copper plate earth electrode 60cmx60cmx3.15mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to copper earth lead strip of size 20X3.0 mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 40 mm dia GI pipe for protection pipe and arrangement of watering pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing complete all as specified and directed by Engineer-in-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead/strip upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 mtr are measured and paid separately.
Supply ,and errection in true vertical position steel tubular swaged pole type 410 or SP-31 , 09 mtr long complete with cast iron base plate and final tape plug, bolts, nuts, washers and screws incl painting with synthetic anamelled aluminium paint two coat over one coat of red oxide primer after errection and providing black and white strips with synthetic enamel point 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete and marking pole number on pole complete all as specified and directed by Engineer-in-Charge. Note: (i) Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost.
Supply and fixing stay assembly complete with all accessories, such as stay plate 230X230X6 mm3, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc. all as per electrical plate No 1 orr SSR part 1 and as directed incl taking down old unsv complete all as specified and directed by Engineer-in-Charge. Note: Only excavation and PCC work will be measured and paid separately.
Surface dressing in soft/loose soil not exceeding 15 cm deep complete all as specified and directed by Engineer-in-Charge.
M&L Broken stone or boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick incl spreading lime stone powder under stones complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Retro reflective sign board of size 900 mm X 1200 mm made of ACP sheet of 3 mm thick. ACP Sheet will be fixed on MS frame of with legs of MS angle section 35 mm X 35 mm X 4 mm on PCC 1:3:6 type 750 mm above he ground level and 2.10 m below the ground level. The background of board to be provided with blue colour, letters and border with white retro reflective tape. Same description will be mentioned on both side of ACP Sheet.The size of letters and description will be as per directed by Engr-in-charge, board will be complete fixing/grouting with nut/bolts/Anchor fastener with washers complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Retro reflective sign board of size 600mmx1800mm made of ACP sheet of 3 mm thick. ACP Sheet will be fixed on wall , The background of board to be provided with blue colour, letters and border with white retro reflective tape. Same description will be mentioned on one side of ACP Sheet.The size of letters and description will be as per directed by Engr-in-charge, board will be fixed on Wall complete fixing/grouting with nut/bolts/Anchor fastener with washers complete all as specified and directed by Engineer-in-Charge.
Repair and replacement of Maintenance free dry battery 12 volt 180 AH minimum warrenty of 36 Months including statndard accessories complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of outdoor type LED flood light 120 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of outdoor type LED flood light 150 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED Street Light Luminaries 90 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Mushroom shaped decorative LED bollard with IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including PCC, cutting , welding , drilling holes, nut bolts, washercomplete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Cylindrical shaped (FLUTE) LED bollard with opal acrylic diffuser and IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete includingPCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Tulip shaped LED bollard with opal acrylic diffuser and IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including PCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LED post top 20 W in made in die-cast aluminium housing with decorative clear opal acrylic diffuser IP 65 protection, warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge.
S&F Busbar Chamber suitable size for set of 04 aluminium busbar 400 Amps rating ,supported with suitable size as per direction, each of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, The Chamber shall be fixed 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of hot pressed moulded SMC boxes with hinged door fixing of size 325mm x 220 mmx 150 mm with MS clamp 25 x 3mm made to shape with necessry nuts bolts clamps and washers complete comprising of Aluminium bus bar 63 Amps capacity of suitable size -04 nos mounted over Porcelain insulator with nuts & bolts washers incl MCB SP 6 amps and making incoming and outging connections by taking out loops of cable of any size incl necesary excavations and other civil works complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar including all quoins, arches , pillars etc but excluding precast concrete articles, complete all as specified and directed by Engineer-in-Charge.
M & L, Brick work with sub class 'B' bricks , straight or curved on plan not exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing ),and removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L First quality glazed ceramic coloured tiles of (450x300mm) x 7 mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:4) set and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed by Engineer-in-Charge.
M&L First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq.m but not exceeding 0.11 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in white cement with pigment to match the shade of tiles complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 12 mm thick cement plaster in cement mortar (1:6) on fair faces of brick works or concrete surfaces , finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound @ 3 % by weight of cement, , finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. Note - WPC shall be measured & paid separately.
M&L for Preparation of new plastered wall surfaces and applying two coats of cement base paint over a coat of primer, complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new plastered or un plastered wall surfaces of any description and applying two coats of oil bound distemper over a coat of Chalk whitening , complete all as specified and directed by the Engineer-in-Charge
Demolition of cement concrete (unreinforced) in ground floors and paving not exc. 15 cm thickness (below or above ground level), including removal of rubbish outside MoD land, complete all as specified and directed by the Engineer in Charge.
M&L Plain cement concrete type B-1(1:2:4) using 20 mm graded stone aggregates as bed block ,coping , cills, steps etc , complete all as specified and directed by Engineer-in-Charge.
S&F, Bib taps, Chromium plated brass, 15 mm bore dia, screwed for iron pipe and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
S&F, PVC valveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level fixed in repair , complete all as specified and directed by Engineer-in-Charge.
S&F, PVC connection of PTMT ,non corrosive with nuts and washers on both ends, 450 mm long suitable for 15 mm bore fixed in repair complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each, from chowkhat, complete all as specified and directed by Engineer-in-Charge.
S&F, Factory made, 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commertial type on both sides, fitted to chowkhats of 2nd class hard wood (hollock) complete all as specified and directed by Engineer-in-Charge.
M&L Aluminium handles ,plate cast type anodised of 150 mm size complete all as specified and directed by Engineer-in-Charge.
M&L Aluminum anodizes barrel tower bolts of extuded section and fixed of 200 mm size, complete all as specified and directed by Engineer-in-Charge
M&L Butt hinges medium weight cold rolled steel of 100 mm size and fixed complete all as specified and directed by Engineer-in-Charge.
M&L Aluminum alloy, anodized, door bolt with hasp staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed length of bolt 250 mm, bolts not less than 16mm dia with and including a minimum of 6 bolts not,four on bolt plate and two on staple plate complete (ISI marked ) , complete all as specified and directed by Engineer-in-Charge
M&L for Preparing new or previously untreated steel surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new wooden surfaces of any description, exceeding 10 cm width or girth of any description and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Dismantling structural steel work in including doors, gates ,angles but excluding framed truss etc complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of walls including preparing old plaster surfaces filling of holes with plaster of paris and applying two coat of oil bound distemper over applying a coat of wall care putty on walls 1 mm thick complete all as specified and directed by Engineer-in-Charge.
M&L prepration of old surfaces of walls filling of holes with plaster of paris and applying one coat of oil bound distemper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted surface of steel & iron work of any description not specifically mentioned otherwise over 10cm width or girth & applying one coat of synthetic enamal paint, complete all as specified and directed by Engineer-in-Charge.
All as per item No 237 above but on Wooden surfaces
S&F in repair PVC waste pipe flexible type 25mm dia suitable for couplings 32mm & 40mm dia 600mm long complete all as specified and directed by Engineer-in-Charge.
Supply only water proofing compound complete all as specified and directed by Engineer-in-Charge.
Demolition of stone slab and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar, complete all as specified and directed by Engineer-in-Charge.
M&L 100 mm thick PCC 1:4:8 type D-2 (using 40mm grade stone aggregate) as in Sub floors,Sub bases ,flooring etc complete all as specified and directed by Engineer-in-Charge
M & L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and coloured pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over 25mm thick coarse sand complete all as specified and directed by Engineer-in-Charge. NOTE : - Coloured pigment refers to coloured tiles.
M&L for Sand filling under floors or in foundation including watering and consolidating complete all as specified and directed by Engineer-in-Charge.
M&L for one coat of cement base paint on old decorated plastered surfaces of wall including washing rubbing down stopping & preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old decorated wall surfaces , filling of holes and cracks with lime putty or plaster of paris and applying one coat of wheather coat/ exterior emulsion paint of electric blue or AF blue colour or white or equivalent colour as approved by GE, using ultra clean paint over the old decorated wall surfaces , edges of slab, roof/chajja projection and column etc, after necessary preparation with all vaccume based sanding machine complete all as specified and directed by Engineer-in-Charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI vased corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S&F Rolled mild steel sections as in roof truss(frames),trussed, purlins,crane gantries,rails and fastening and heavy bracket framing(beam,tee,angle,channel or flat sections) including cleats GDE Fe 410-W(Gde-E-250)quality A complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre pulp insulation etc) or insulation boards, slabs, blankets any thickness, incl cover fillets complete all as specified and directed by Engineer-in-Charge.
S&F, Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed by Engineer-in-Charge.
M&L for 12mm Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed by Engineer-in-Charge.
M&L Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed by Engineer-in-Charge.
J P ENTERPRISES
Singh Associates
NAVYUG VYAPARI
M/S Anand Enterprises
KRISHANA ELECTRIC WORKS
M/S Yamin
GARG CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .