| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹2.7 Cr | L1 | Accepted-AOC lowest |
| 2 | L2₹2.8 Cr+₹1.1 L (0.41%)Rejected-Finance | ₹2.8 Cr+₹1.1 L (0.41%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹2.8 Cr+₹4.3 L (1.55%)Rejected-Finance 15 HOSHIYAR SINGH PARK KIRBY PLACE DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹2.8 Cr+₹4.3 L (1.55%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹2.8 Cr+₹4.8 L (1.75%)Rejected-Finance | ₹2.8 Cr+₹4.8 L (1.75%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹2.8 Cr+₹7.6 L (2.76%)Rejected-Finance 123 B CENTRAL AVENUE SAINIK FARMS SOUTH DELHI DELHI 110062 | SOUTH DELHI | DELHI | 110062 | ₹2.8 Cr+₹7.6 L (2.76%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹2.9 Cr
EMD Value
₹3.7 L
Closing Date
8 Jan 2020, 6:00 pmClosed
CE (AF) WAC PALAM, DELHI CANTT-10
HQ CE (AF) WAC PALAM, DELHI CANTT-10
PROVISION OF SINGLE LIVING ACCOMODATION FOR DSC AT NTS GURGAON
2019_MES_267296_3
CEWAC/GUR/T-36/2019-20
Open Tender
Civil Works
Lump-sum
455 days
GURGAON
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GE (AF) GURGAON
₹3.7 L
Yes
4 Feb 2020
28 Nov 2019
9 Jan 2020
28 Nov 2019
8 Jan 2020
18 Dec 2019
28 Nov 2019 - 10 Dec 2019
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Construction of single living accomodation building for one JCO including scooter shed with permanent specifications complete all as specefied as shown on drawings.
Construction of single living accomodation building for 03 Hav & 50 Ors (G+3) with permanent specifications complete all as specefied as shown on drawings.
Construction of Dinning Hall & Cook house building for 03 Hav & 50 Ors (Single Storey) with permanent specifications complete all as specefied as shown on drawings.
Construction of Under ground sump of capacity 50000 Ltrs with permanent specifications complete all as specefied as shown on drawings.
Construction of RCC septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC m-30 design Mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc, complete with effective depth of 1.5 m and over all depth of 3m for 100 user with permanent specifications complete all as specefied as shown on drawings.
Construction of sokage well, 3.60m dia x 6.00 m deep, exc in ordinary soil, foundation in PCC 1:3:6, walls of honey combed and solid in M-25 concrete including intercepting chamber, screen chamber, brick work in CM 1:4, RCC cover slab in M-25 / RR masonry / filling with brick bats, with permanent specifications complete all as specefied as shown on drawings.
NOTE: Schedule ‘A’ Part II to XII under are Prepriced by MES.
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION"” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “AREA DRAINAGE WORK” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “ROAD, PATH AND HARDSTANDING " as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “COMPOUBD WALL AND GATES" as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-IX
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “HOT WATER SUPPLY" as listed in Schedule ‘A’ Part XI
Lump sum price worked out by the Contractor for “RAIN WATER HARVESTING" as listed in Schedule ‘A’ Part XII
SCHEDULE `A' PART - XIII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
INTERNAL ELECTRIFICATION
S&F LED bulb 09 watt complete all as specified and directed. Make:Bajaj /Philips /Havells.
Supply and fixing ceiling fan five star 1200 mm sweep complete with modular fan regulator 230 volts (single phase) and provisioning of flexible copper cord three core PVC sheathed of size 23/0.0076 of required length from ceiling rose or connector to ceiling fan for giving connection complete all as specified and as directed by Engineer-in-Charge. Make for Fan: Crompton/Bajaj/ Havells.
Supply and fixing fiber body exhaust fan of size 450 mm sweep, 1400 RPM 6120 CMH (air delivery) 230 volts single phase AC supply with louvers complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible copper cord three core PVC sheathed of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed by Engineer-in-Charge.Make for Exh. Fan : Crompton/Bajaj/halonix(krypton HDEF)
Supply and fixing fiber body exhaust fan of size 300 mm sweep, 1400 RPM 1050 CMH (air delivery) 230 volts single phase AC supply with louvers complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible copper cord three core PVC sheathed of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed by Engineer-in-Charge.Make for Exh. Fan : Crompton/Bajaj/halonix(krypton LDEF)
S&F energy saving decorative box type batten light fitting 230 Volts surface mounted complete with high efficiency PMMA diffuser soft glare free light LED Tube light 20 watt, blue coloured end caps with all accessories, pre-wired, including providing flexible copper wire, three core cable PVC insulated sheathed complete all as specified and directed by Engineer-in-Charge. Cat No- HLB-03-20-CW-AL(HALONIX) or equivalant in Phillips/Havells/Osram
Supply & Fixing LED security light fitting 30 watt, having uniformaty ratio 0.25, high pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection comlete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and fixing on Gl pipe bracket made out of suitable dia Gl pipe medium grade 1.2mtr long bent to shape and fixed on wall with flat iron clamps, nut, bolts washer etc all as specified and directed.Cat No- HLSLD-09-30-CW(HALONIX) or equivalant in Phillips/Havells/Osram
S&F LED sleek mirror light fitting 10 watt provided with high output diffuser 2 ft long, 230 Volts complete with all accessories, pre-wired including lamp and providing flexible copper wire, three core cable PVC insulated sheathed complete all as specified and directed by Engineer-in-Charge. Cat No- HLB-03-10-CW-AL(HALONIX) or its equivalent in in Phillips /Havells /Osram.
S&F energy saving surface/recessed mounted decorative luminaire LED light fitting 36 Watt, 230 Volts suitable for 600x600 mm Modular/POP/Gypsum ceiling with high efficiency PMMA diffuser soft glare free light LED lamp etc complete with all accessories, pre-wired including lamp and providing flexible copper wire, three core cable PVC insulated sheathed complete all as specified and directed by Engineer-in-Charge. Cat No- HLFPR22-03-36-CW-R (HALONIX) or equivalant in Phillips/Havells/Osram
NOTE FOR ITEM N 3.05 TO 3.08 :- (i) For all types of LED fittings and luminaire should be same manufacturer. (ii) LM -79 cretificate for all light fittings shall be submitted by the contractor before fixing at site or taking payment against material.(iii) System efficiency should be more than 100 lummens / watt (d) CRI should be 80 (v) THD should be less than 20% (vi) PF should be more than 0.95
S&F sheet metal enclosures Vertical type doubledoor (VTPN) MCCB incomer, with Acrylic Door, cement spill protector For MCCB Triple pole and neutral, 4 ways, IP-43 protection, with 100 Amps rated bus bar breaking capacity 25KA , 415 Volts complete all as specified and directed by Engineer-in-Charge.Make : Indoasian/Legrand/L&T Cat part No- 811888 of Opti pro INDOASIAN.
S&F MCCB 3 pole, 415 Volt, C curve fixed type 100 Amps with breaking capacity 16 KA complete all as specified and directed. Make : Indoasian/Legrand/L&T Cat part No- 830228 of Opti pro INDOASIAN
S&F MCB SP 6 to 32 Amps, C Curve type 10 KA breaking capacity 240 Volts complete. Make : Indoasian/Legrand/L&T Cat part No- 811122 TO 811126 of Opti pro INDOASIAN
S&F MCB SP 40 to 63 Amps, C Curve type 10 KA breaking capacity 240 Volts complete. Make : Indoasian/Legrand/L&T Cat part No- 811130 TO 811132 of Opti pro INDOASIAN
S&F MCB SPN 40 Amps to 63 Amps, C curve type 10 KA Breaking capacity 240 Volts complete. Make : Indoasian/Legrand/L&T Cat part No- 811152 of Opti pro INDOASIAN
S/F socket outlet modular type 6 amps 5 pin combined two module 230 volts complete all as specified and as directed. Make - Seimens / Legrand / Crabtree
S/F socket outlet modulor type 6 &16 Amp, 3 & 6 pin combined shuttered type 230volts complete all as specified and directed. Make - Seimens / Legrand / Crabtree
S&F switch modular type 1 way 6 A, one module 230 volts complete all as specified and as directed. Make - Seimens / Legrand / Crabtree
S&F switch modular type 2 way 6 A, one module 230 volts complete all as specified and as directed. Make - Seimens / Legrand / Crabtree
S&F bell push modular type 6 A, one module 230 volts complete all as specified and as directed. Make - Seimens / Legrand / Crabtree
S&F switch modular type 1 way 16 A, one module 230 volts complete all as specified and as directed. Make - Seimens / Legrand / Crabtree
S&F modular metal flush box 2 module complete all as specified and as directed.
S&F modular metal flush box 3 module complete all as specified and as directed.
S&F modular metal flush box 4 module complete all as specified and as directed.
S&F modular metal flush box 6 module complete all as specified and as directed.
S&F modular metal flush box 8 module complete all as specified and as directed.
S&F modular metal flush box 12 module complete all as specified and as directed.
S&F modular white cover plate with frame 2 module complete all as specified and as directed.
S&F modular white cover plate with frame 3 module complete all as specified and as directed.
S&F modular white cover plate with frame 4 module complete all as specified and as directed.
S&F modular white cover plate with frame 6 module complete all as specified and as directed.
S&F modular white cover plate with frame 8 module complete all as specified and as directed.
S&F modular white cover plate with frame 12 module complete all as specified and as directed.
ROAD, PATH AND HARDSTANDING
M & L for thermoplastic paint on black top surfaces or existing unpainted surfaces and applied hot mixing plant of heating of thermo plastic materials to a standard temp with gas and laying standard thickness of approximate 2 mm, by using thermo plastic materials @ 6.50kg/Sqm, and glass beads @ 250 gms/Sqm including cleaning of old surfaces, complete all as specified and directed.
RAIN WATER HARVESTING
M&L drilling 8" (200) bore, holes by roatary drilling method below GL in any type of soil including disposal and surplus soil to distance exc 1.50 KM but not 5.00 KM etc complete all as specified and directed.
S & F UPVC wellcap 6 " (150mm) bore mild steel ARW pipe having internal threads and with welded iron handles and fixed in position complete all as specified and as directed
S & F UPVC slotted pipe SCH-40, 150 mm dia bore having 2.3mmX7.5mm slot complete with necessary fitting jointed complete all as specified and as directed
M & L for Developing the harvesing bore by means of air compressure at 250 CFM (commpressure / water) as required for developing shall be used and arrenged by the contractor by its on resources complete all as specified and directed .
EXTERNAL WATER SUPPLY
Supply and laying ductile iron pipe, soket and spigot type of 'K-9' class, 100 mm dia confirming to IS-8329 cement lined laid in trenches / ground with rubber tyton joint with SBR gasket as per IS-5382 marked suitable for pressurized water delivery complete all as specified.
Material and labour for ISI marked heavy duty ductile iron confirming to IS-9523 marked socket fittings of 100 mm dia such as bends, Tapers tale pieces, Tee pieces (single branch) Y junction double branch,cross collars, caps and plug set including rubber ring push on joints complete as specified and directed. Make Electro steel/JINDAL
Supply, fixing and commissioning flanged non-rising type’.Bronze foot valve/ Check Valve of size 80mm suitable for pressure rating duly drilled holes for fixing of nuts and bolts ISI marked including rubber gasket, nuts, bolts and washers complete all as specified.
Supply, installation, testing & commissioning of factory assembled and tested electric motor driven three phase 415 volts Ac, 50 Hz, monoblock water pumpset capable of discharge 10-15 LPS of water as at minimum 30 mtrs head and capacity not less than 15HP comprising of heavy duty type split casing type centrifugal pump, cast iron body with bronze impeller casing rings sleeves etc coupled to TEFC electric motor of suitable capacity 3000 rpm by means of flexible coupling and mounted on common fabricated MS base frame and Gl pipe heavy duty at suction and delivery pipe of suitable size as reccommended by manufacturer upto suitable length at suction end and delivery connection to header with necessary fittings. Note: (i) cost of Gl pipe heavy duty at suction and delivery pipe of suitable size as reccommended by manufacturer upto suitable length at suction end and delivery connection to header with necessary fittings shall be included in overall cost quoted. (ii) Cost of foundation as per manufacturer recommended drawing with nuts bolts anti! vibration pads are included in overall rate quoted. (iii) Cost of 3 core copper flat cable from panel to pump of suitable capacity deemed included in the item rate.
Supplying , installation, commissioning and testing of LT panel, indoor type CPRI approved base frame mounted dust and vermin proof totally enclosed platform mounted factory made (protection class IP-54) double shutter gear front and rear frame work with bus bar chamber to accommodate 3phase and neutral, 415Volt with suitable aluminium busbar of 200 Amps capacity and neutral bus bar of capacity 100 Amps designed as per relevant IS connected to busbar by aluminium strip of suitable Size, fabricated out of 2.00 mm thick CRCA sheet for outer chamber and 1.6 mm thick for partition and doors and painting with powder coated over two coats of redoxide primer and made of 40x40x6mm thick angle iron frame all as specified and fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation 40 cm above ground level including internal wiring with suitable size of PVC insulated copper cable (but not less tha 6 Sqmm) and copper lugs of following accessories:
M&L for construction of Valve pit chamber 90 cmx90cm (inner dimension) and 90 cm deep, from the top of MS cover fixed on PCC Base , top cover shall be of 3 mm thick MS Sheet with locking arrangement of pad lock of 50mm size including brick work with sub class'B" bricks in CM 1:4 including 15 mm thick plaster in CM 1:4 (internally and externally) and necessray earth work in any type of soil including returning filling in and disposal of surplus soil to a distance n exc 50 mtrs and 150 mm thick PCC 1:4:8 , type D-2 , using 40mm graded stone aggregates as in floor complete all as specified and directed by Engineer - In - Charge.
EXTERNAL ELECTRIFICATION
Supply and fixing LED street light luminaire IP-66 grade of protection with 24 high power LED of 45 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and directed. Make: CG, C & S, Philips.
S&F bracket made of Gl pipe light grade 40mm bore bent to shape in 120 degree of 1.2 m in length suitable for fixing street light luminaire and fixed on wall/pole including necessary MS clamps of size 50mm thick, nuts, bolts etc complete all as specified and as directed
Supply and fix kiosk poie box made out of Engineering plastic comprising 60Amps, 4 pole strip, mounted on DMC insulator.one in No. MCB SP 6 Amps, 10 KA, Size 310 x 210 x 120mm and fixed with MS flat iron clamps to pole complete all as specified and as directed. Make : Hensel/Sintex/Universal Switch Gear control.
Supply, installation, testing and commissioning 200 KVA, 11/433KV, 3 phase, 50 Hz, Dyn 11, outdoor ONAN type , copper wound, oil immersed, naturally cooled, step down transformer confirming to BEE standarda with ogg load tap changing arrangement on HV side in steps of + 2.5% and + 7.5% having cable end box on HV and LV side should be suitable to housing for proper size and capacityof outgoing aluminium cable and provide with gland. The transformer shall be provided with all standard accessories and first filling of filtered dehydrated transformer oil complete as per specification and conforming to IS 1180 (Part-I) 2014.
The transformer shall be following accessories. (i) Oil conservator with filter type drain valve and gauge. (ii) Dehydrating breather with silica gel. (iii) Explosive vent with double dia frame and sight glass (iv) Thermometer dial type having range 0-120o (v) Two earthing terminal on tank body (vi) Radiator and specification plate (vii) Oil level guage (viii) Oil drain filter valve (ix) Oil filling post on top cove with plug (x) Four Nos of plain cast steel bidirectional deteachable rollers
Supply, installation, commissioning-and testing of LT panel, outdoor type Feeder pillar box dust and vermin proof totally enclosed platform mounted factory made (protection class IP-54) double shutter gear front and rear frame work with bus chamber to accommodate 3phase and neutral, 415Volt with suitable aluminium busbar of 500 Amps capacity and neutral bus bar of capacity 250 Amps designe as per relevant IS connected to busbar by aluminium strip of suitable Size, fabricated out of 3.15 mm thick CRCA sheet for outer chamber and 1.6 mm thic for partition and doors and painting with powder coated over two coats of redoxid primer and made of 40x40x6mm thick angle iron frame all as specified and fixed PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation 40 above ground level including internal wiring with suitable size of PVC insulated copper cable (but not less tha 6 Sqmm) and copper lugs of following accessorie.
S & F automatic power factor correction (APFC) panel for 3 phase, 415 V & 50 Hz system of capacity 40 KVAR (20 KVAR x 1 + 10KVAR x 1 + 2 KVAR x 5) with incoming MCCB 250 Amps 36 KVA, 4 pole including CT of suitable capacity and size including suitable size of cable with proper thimbling complete all as specified and directed.
S&F MS cable root indicator with spike and disc of 100mm dia for HT cable, duly iembossed with the words, 'HT Cable" on the disc, supported on angle iron 40mmx40mmx5mm complete all as specified and directed by the EIC. Note: Excavation and earth work, PCC 1:2:4, type B-1 embedding block of size 150mm x 150mm x 150mm and painting of angle iron with brown colour supported with two coats of synthetic enamel paint over a coat of red oxide primer shall be |deemed to be included in the quoted rate. complete all as specified and directed.
M&L for boring holes under road pavement hard standing by augaring method manual means for insertion and including of 80 mm bore Gl pipe complete all as specified and as directed.
M&L for road cutting upto 450mm deep and inserting Gl pipe of 6mtrs as per size jof cable including making good the disturbed surface by filling mass concrete of 20mm thick complete all as specified and directed.
REFRIGRATION AND AIR CONDITIONING
Supply and fixing refrigerator, electric driven (single phase), of capacity upto 192 Ltrs, BEE 5 star rated, complete all as specified and directed.
Supply and fixing refrigerator, electric driven (single phase), of capacity upto 310 Ltrs, BEE 5 star rated, complete all as specified and directed.
Supply and fixing water cooler, electric driven (single phase), having storage capacity of 80 ltrs and nominal cooling capacity of of 40 Ltr per hour including Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling of size 40mm dia for of minimum 6 mtr length and pvc flexible pipe as connector for passing out the waste water, complete all as specified and directed.
Supply and fixing desert cooler, electric driven (single phase) having nominal air flow of capacity 4000 Cum per hours (or nearest size) of Plastic body, complete all as specified and directed.
Supply and fixing deep freezer glass top more than 300 ltrs capacity having double door, complete all as specified and directed.
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and of capacity 1 KVA. complete all as specified and directed.
Apex HVAC Services Pvt. Ltd.
Shivom Projects Private limited
Phogat Builders
Third Wave Services Pvt Ltd
M/S Chhavi Constructions Co
Goyal Enterprises
Ashish Sehgal and Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .