Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹42.1 L+₹3.2 L (8.10%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹43.8 L+₹4.8 L (12.3%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹45.4 L+₹6.4 L (16.4%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹46.8 L+₹7.8 L (20.0%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Nov 2023, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR/ MAINTENANCE OF HT/LT SWITCH GEAR, PANELS, OH LINES/UG CABLES, TRANSFORMERS AND OTHER CONNECTED WORKS AT SECUNDERABAD
2023_MES_623528_1
GE I KBAGH TOKEN 84 OF 2023 2024
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹80,000
Yes
21 Dec 2023
16 Oct 2023
8 Nov 2023
16 Oct 2023
6 Nov 2023
30 Oct 2023
16 Oct 2023 - 23 Oct 2023
Amount
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick using soil complete all as directed.
Removing excavated material to a distance exc 250m but n exc. 500m and depositing where directed at a level n exc. 1.5m above the starting point (Soils) complete all as directed.
Supply and spreading natural dry, clean river sand in trenches for cushioning of cable complete all as directed.
M&L for brick protection with common burnt bricks sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed.
S&F unreinforced precast concrete cable cover class HV type 1 flat of size 300mmx 180mm x 40mm complete all as directed.
Supply, laying, testing of Cable with Stranded Compacted Circular Aluminium Conductor, 11000Volts, XLPE Insulated of size 120 sqmm, 3 core with appropriate lugs including taking down unserviceable cable complete all as directed.
All as per item No 7.00 here-in-before but 95 sqmm 3 core complete all as directed. Make for item srl No 07 & 08 - Havells/Universal/Gloster/Polycab
M&L in repairs for cable jointing kit for 11000Volts (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as directed.
All as per srl item No 9 here-in-before but 50 sqmm to 95 sqmm all as directed.
M&L in repairs for cable jointing kit for 11000Volts (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as directed.
All as per item No 11 here-in-before but 50 sqmm to 95 sqmm all as directed. Make for item srl No 09 to 12 : Raychem/M-Seal/3M
M&L for GI tubing of 80 mm bore 'Light Grade' for protection of HT cable with all fixing accessories laid in trenches/walls including taking down unserviceable GI tube complete all as directed. Make:Jindal/Tata/Zenith
M&L for cutting and removing grass, plants, bushes of the two pole/four pole structure area including surrounding of transformer plinth and dispose the cut grass, plants, bushes to be taken out or destroyed by the contractor to a distance exceeding 2 KM from the site of work complete all as specified and s directed by Engr-in-charge.
M&L for spreading and leveling of 40mm graded stone aggregate over stone dust (0-3mm) in transformer yard complete all as directed by Engr-in-charge. Note : After ramming stone dust layer will be of minimum 25mm thickness
M&L for Cutting and removing tree branches of any height and of any size, hanging on HT/LT lines, street lights, and the cut tree branches / trimming and shall be removed to a distance exceeding 2 km and not exceeding 4 Km from the site of work (out side Mod land) complete all as directed
Cutting the road /hard standing to a size not exceeding 45 cm in width and not exceeding 75 cm in depth for laying / removal of LT/HT UG cable /protection pipe including making good so as to match with existing finishing with PCC (1:2:4) type B1 (using 20mm grade stone aggregate) for 100mm thick on top including fair finishing complete all as directed.
S&F Laying LT UG cable heavy duty armoured with aluminum conductor multistranded PVC insulated and sheathed with suitable lugs including taking out old unserviceable cable complete all as directed for following sizes: -
2 core 10 Sqmm
4core 16 Sqmm
3.5 core 25 Sqmm.
3.5 core 35 Sqmm.
3.5 core 50 Sqmm.
3.5 core 95 Sqmm.
3.5 core 120 Sqmm.
3.5 core 185 Sqmm.
3.5 core 240Sqmm.
Note: - .Excavation & earthwork, sand cushioning and brick protection shall be measured and paid seperately under relevant items. Make for item 18.01 to 18.09 : Havells/Universal/Gloster/Polycab
S&F in replacement Aluminium lugs of following sizes:- Make : Dowell/Jainson
16 to 35 Sqmm
S&F Air Circuit Breaker 4 Pole, 415 Volts, Manual Drawout type with microprocessor release of capacity 800 Amps all as specified and directed.
S&F MCCB four pole 250 Amps, 415 volts 36 KA, including taking out old unserviceable MCCB complete all as directed.
S&F MCCB four pole 160 Amps, 415 volts 36 KA, including taking out old unserviceable MCCB complete all as directed.
S&F MCCB four pole 100 Amps, 415 volts 16 KA, including taking out old unserviceable MCCB complete all as directed.
S&F MCCB four pole 63 Amps, 415 volts 16 KA, including taking out old unserviceable one complete all as direced.
S&F Change over switch 200 amps, four pole,415 amps with all accessories & suitable lugs including taking out old unserviceable change over switch complete all as directed.
S&F Change over switch 320 amps, four pole,415 amps with all accessories & suitable lugs including taking out old unserviceable change over switch complete all as directed. Make for Item srl No : 21 to 26 - Havells/Standard/L&T/CG
S&F Change over switch 630 amps, four pole, 415 Amps with all accessories, enclouser & suitable lugs including taking down old unserviceable complete all as specified.
Supply and fixing switch Air break Gang operated triple pole mechanically operated with GI operated rod, insulator (wire isulator type) and steel frame with operating mechanisim worked from ground level verticle/Horizontal type, for current rating upto 200 Amps, HT 11000 volts including locking arrangement with six lever lock and painting the steel surfaces with two coats of aluminimum paint over a coat of red oxide primer including taking down unserviceable switch air break complete all as directed.
Supply and install Horn gap fuse assembly (solid core insulator type) and steel frame etc suitable for HT 11000 Volts with HT fuse element upto 50 amps including taking down unserviceable fuse assembly complete all as directed.
Supply and fixing drop out expulsion fuse assembly single pole mounted on insulator (two isulator type) and steel frame etc suitable for HT 11000Volts grade with burried fuses & HT fuse element up to 50 Amps including taking down unserviceable drop out expulsion fuse assembly complete all as directed.
M&L for lightining arrestor for outdoor fuse expulsion type complete with all fittings, transmission class earthed system discharge capacity 65 KA suitable for 11000 volts grade including taking down unserviceable lightining arrestor complete all as directed.
M&L for Aluminum conductor, steel reinforced (ACSR) of size 6/2.11 mm (rapid) not exceeding 2 mtr long for jumper connection between lightning arrester and pin insulator, pin insulator and AB switch, AB switch and HG fuse, drop out expulsion to transformer, including necessary lugs, binding wire, heavy duty PG clamps, PVC sleeves with R, Y, B colour code inlcuding taking down unserviceable aluminium conductor complete all as directed. Make: - Raychem/Transpower/Denson
M & L danger notice plate of 1.6mm thick Mild steel sheet vitreous enameled white, with letters, figures and conventional skull and bones in signal red color and fixed with MS clamps, bolts and nuts of approved size for HT 25 x 20cm size including taking down unserviceable danger notice plate complete all as directed.
Overhauling of transformer by disconnecting the HT and LT side supply, dismantling the clamps, bolts, nuts & washers, lifting the transformer from structure by using crane and transport to the workshop to carry out the repair by draining out the transformer oil through the drain plug, removing the top portion, lifting the primary and secondary winding without disturbing or damaging the core and the coil, clean the bottom portion of the transformer tank by removing the deposited material, clean and keep the primary and secondary winding with core in electric oven minimum for 48 hours to enhance the insulation valve of the windings, supply and fixing breather pipe and packing, silica jel, oil level indicating transparent glass with marking minimum and maximum oil level indication, HT and LT side bushes assembly, gaskets and oil seals set including taking down u/s items and reassembling the transformer, refilling the transformer oil, reinstallation, testing and commissioning of the transformer should be carried out at required locations as directed for the following capacities:
100 KVA to 160 KVA capacity transformer Make - Kirloskar/HIT
210 KVA to 315 KVA capacity transformer Make - Essenar/HIT
Note: The rate quoted shall be deemed to include the following: (i) Overhauling of Transformer shall be done by the technician from reputed manufacturer's (ii) The required transportation, Crane, repairing tools shall be arranged by the contractor. (iii) De-hydration of the transformer oil should be carried out to improve BDV to withstand operational voltage before refilling (iv) Leak test to be carried out and rectified by brazing, welding etc before re-filling of the dehydrated transformer oil. (v) If any damage occurred during repair/testing of transformer then the responsibility lies with the contractor for rectification without any extra cost.
Supply and filling of Transformer oil suitable for distribution of transformer with di-electric strength of BDV 60 KV complete including removal of unserviceable oil complete. Make - Power oil/Castrol/Servo
M&L for Plain Cement concrete 1:2:4 type B-2, (using 40mm graded aggregate) 100mm thick as in path/floor including demolition of old concrete and removal of debris outside MOD land complete all as directed.
Filtration of cooling/insulation oil of HT/LT transformer and carbon deposit from the oil through straight line oil filtration plant, extracting the moisture contents and shall withstand 40 KV for one minute dielectric strength, testing the oil for dielectric strength and acidity before and after filtration and submitting the test result all as directed including topping up of the oil in the transformer and painting of the transformer with two coats of of synthetic enamel paint of approved 7 colour as directed by Engineer in charge of Capacity 100 KVA (Pratap Colony) Note: - For topping up of the transformer oil will be measured and paid separately.
All as per srl item no. 37 here in before but for Transformer of capacity 160 KVA (SERA)
All as per srl item no. 37 here in before but for Transformer of capacity 210 KVA ( CE (R&D) Office Complex & VVRA).
All as per srl item no. 37 here in before but for Transformer of capacity 250 KVA ( Diber & CE (R&D) Residential Area)
All as per srl item no. 37 here in before but for Transformer of capacity 315 KVA (DMDE)
S&F following items suitable for existing full height single lane turnstile of size 1500x1500x2000mm & tripod turnstile of 500mm walkway including fixing accessories and taking down unserviceable items complete all as directed.
Adaptor 24V DC input
IC (Integrated Circuit)
Push button element with enclosure
Control Panel
Sensor
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board EACH CPRI approved cubical type made of 3.15mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front open able shutters of each feeder control unit with locking arrangement in front and back open able inspection doors PVC sleeved Aluminium bus bar of 500 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No. CTs of suitable ratio, and Indicating LED type lamp for Red, Yellow and Blue in comer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations of suitable size, testing and commissioning complete and consisting following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole 400 Amps 35KA -01 No. (as Incoming) (b) MCCB 4 Pole 160 Amps 25KA -03 No. (as Outgoing) (b) MCCB 4 Pole 100 Amps 25KA -03 No. (as Outgoing) (b) MCCB 4 Pole 63 Amps 16KA - 03 No. (as Outgoing)
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board EACH CPRI approved cubical type made of 2mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front open able shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 400 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No. CTs of suitable ratio, and Indicating LED type lamp for Red, Yellow and Blue in comer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations of suitable size, testing and commissioning complete and consisting following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole 315 Amps 35KA -01 No. (as Incoming) (b) MCCB 4 Pole 160 Amps 25KA -02 No. (as Outgoing) (b) MCCB 4 Pole 100 Amps 25KA -02 No. (as Outgoing) (b) MCCB 4 Pole 63 Amps 16KA - 02 No. (as Outgoing)
S&F in repairs bus bar chambers wall/pole/angle iron based mounted of capacity 100 Amps 8 way with necessary connecting arrangement like clamp, angle iron , nuts & bolts etc complete all as directed.
S&F in repairs bus bar chambers wall/pole/angle iron based mounted of capacity 200 Amps 6 way with necessary connecting arrangement like clamp, angle iron , nuts & bolts etc complete all as directed.
Supply and fixing, in replacement, current transformer ratio 100 /50/5-5A VA 2.5 , 50 Hz class SP, Short Circuit Current Capacity 21.0 KA for 3 sec complete all as specified and directed.
Supply and fixing antipumping plug-in type relay SPD/Eq type with aux volt 110 V Dc and Aux contacts 1 NO + 1 NC
Supply and fix, in replacement, maintenance free battery, 2 Volt 100 AH (as per existing sample/ capacity) complete all as specified.
Supply and fixing of battery charger of for maintenance battery of 2 Volt 100 AH battery for Vacuumed circuit breaker all as specified and directed
Supply and fixing of 3 pole power contactor MNX 24 of coil voltage 220/415 Volt, 50 Hz all as specified and directed Make : L&T / Siemens / Legrand
S&F Air termination point vertical type single pointed made with 12mm dia 300mm long copper rod including necessary fixing arrangement with aluminium boits, nuts, lead wasters etc. complete and inch provision of GI tubing grade 40mm dia,300mm long embedded in PCC block (size 30cm X30cm X 30cm) one end and other end fitted with air termination rod incl taking down old termination rod complete all as specified and directed.
S&F aluminium strip of size 25 x 3.15 mm horizontal/ Vertical down conductors and incl epoxy insulator bus bar type 40mm thick at an internal of 60 cm apart for lightening protection on roof and for down conductors including all fixing arrangements with aluminium nuts, bolts & washers complete all as per IS-2309-1989 and testing incl taking down old aluminium strip all as specified.
S&F Galvanized from strip of size 32 x 6 mm from earth pit to test point provided all around the bldg for lightening protection laid in trenches /fixed to walls on epoxy insulators with screws etc and connecting up incl taking down old galvanized strip complete all as directed.
Replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to GI strip 32 x 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified.
M& L for providing of standby rented Transformer of suitable capacity after receiving the complaint of non working of existing transformer of capacity 100 KVA to 315 KVA within 12 hours of time frame before taking the existing transformer to the workshop from the site. The job includes disconnection the existing transformer and shifting of rented transformer in place of the existing transformer including electric connection. Till the time the existing transformer get repaired/rewinding of the transformer done at workshop the rented transformer should be in site in good condition as per the satisfaction of Engineer-in-Charge
Servicing of 11000 Volts 3 phase 50 Hz indoor type totally enclosed metal clad switchgear complete with Vacuum Circuit breaker of rating up to 800 amps any make by switch off the charging motor and discharge spring energy storage mechanism by closing and opening the breaker once cleaning of more strongly adhering contamination with slightly alkaline or revolt BWR210, wipe down and cleaning using cleaning water and dry properly, relubricate using is flex topas of pawls, support shafts, sliding and rotate bearing surfaces check the tightness of fasting bolts, replace spring lock washers, split pins and carbon bushes including testing all as directed
Supply and fix in replacement of silica gel in breather assembly different capacity of transformer all as directed by Engineer in charge
Supply and fixing in repair of protection cover for LT and HT side of the outdoor type transformer of any capacity, the protection cover should be made out of 3 mm dia CRCA sheet in rectangular, triangular or square shape and fixing the same cover by means of nuts, bolts, etc including applying one coat of red oxide and two coat of super enamel paint over the exposed surface of the box all as directed by Engineer in charge
Attending External electric major complaints which the outsourcing electricians are not able to complete by deputing Highly skilled electrician as and when complaint received by JE E/M/ Engineer-in-Charge at different sites i.e. CE R&D, DMDE, Varun Vihar, Pratap Colony, Ombir Colony, Gopal colony. Note :- The spares will be measured and paid separately. The electrician to reach the complaint site within 3 hrs of receiving of complaint on phone/whatsaap etc. failing which a penalty of Rs 500/- per hour will be levied on the contractor as penalty.
S&F in replacement of LED phase indicator lamp set (R,Y,B) all as specified and directed by Engineer-in-Charge.
BHAGYARAM ENTERPRISES
M/s ANUSHA ENTERPRISES
Shreshta Associates
hari enterprises
sanjar enterprises
SRI SAI ENTERPRISES
SUN LIGHT HOUSE
Bismi Engineering
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .