| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | ₹24.1 L Quoted ₹25.0 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹26.6 L+₹1.6 L (6.51%)Rejected-Finance | ₹26.6 L+₹1.6 L (6.51%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹30.5 L+₹5.5 L (21.9%)Rejected-Finance | ₹30.5 L+₹5.5 L (21.9%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹30.6 L+₹5.6 L (22.4%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | ₹30.6 L+₹5.6 L (22.4%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹38 L+₹13.0 L (52.1%)Rejected-Finance 58 CHANDRALOK BUILDING MAYO HOSPITAL ROAD NAGPUR 440 018 | NAGPUR | MAHARASHTRA | 440018 | ₹38 L+₹13.0 L (52.1%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 Aug 2022, 6:00 pmClosed
GE Kamptee
Garrison Engineer, Kamptee Cantt - 441 001
REPAIR/ REPLACEMENT TO UG CABLE, MAINT AND REPLACEMENT OF LT PANEL/ CAPACITOR BANK AND CONNECTED ITEMS OF DISTRIBUTION SYSTEMS IN MICTS, 414 ASC, R LINES, FTP KAMPTEE AND NAGPUR UNDER GE KAMPTEE
2022_MES_537183_1
8425/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee and Nagpur
Class D, Cat b (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹70,000
Yes
24 Aug 2022
11 Jul 2022
10 Aug 2022
11 Jul 2022
8 Aug 2022
26 Jul 2022
Amount
Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables, poles, stay and getting out of excavated material complete all as specified and directed.
Excavation in trenches in any type of hard/dense soil/ hard standing not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables, poles, stay and getting out of excavated material complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed.
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
S&F in repair double wall corrugated high density polymer ethyl (HDPE) pipe for laying of electric cable of size 50mm outer diameter and 38mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. Make:- Dura Line/ Tijaria/ REX / Ketron
S&F in repair double wall corrugated high density polymer ethyl (HDPE) pipe for laying of electric cable of size 63mm outer diameter and 51mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. Make:- Dura Line/ Tijaria/ REX / Ketron
S&F in repair double wall corrugated high density polymer ethyl (HDPE) pipe for laying of electric cable of size 90mm outer diameter and 76mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. Make:- Dura Line/ Tijaria/ REX / Ketron
M&L for RCC slab type B0 1:2:4 for cable route indicators of size length 0.9 mtr x 0.3mtr x 0.065 mtr duly writing "MES LT/HT Cabe" duly painted with Weather coat paint embeded in PCC 1:4:6 under ground at depth 0.45 mtr complete all as specified and directed.
Taking down the unserviceable LT cable of any size from trenches/ walls /floor etc complete all as specified and directed. Note:- laying of cable route is same as old cable route.
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 120 sq mm, 3.5 core including testing after laid and jointed complete all as specified and directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
All as per item No. 10 above but cable size 95 sq mm 3.5 core complete all as specified and directed.
All as per item No.10 above but cable size 50 sq mm 3.5 core complete all as specified and directed.
All as per item No. 10 above but cable size 35 sq mm 3.5 core complete all as specified and directed.
All as per item No. 10 above but cable size 16 sq mm 4 core complete all as specified and directed.
Taking out earthing of any type complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth strip 30 x 5mm by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 40mm bore, light grade 7.5m long as applicable and as per plate No. 5 of SSR 2009 complete all as specified and directed. (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode. (c) PCC pit in cement concrete (1:2:4) type B-1. (d) 40mm thick Pre-cast RCC cover with suitable handle. (e) Funnel with watering pipe of GI 20 mm nominal bore, medium grade & copper lug etc. (f) 40mm nominal bore medium grade GI protection pipe 7.50m long for protection of earthing lead. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion.
S&F in repair Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 to 185 Sq mm complete all as specified and directed. Note:- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately.
All as per item No. 17 above but cable size 70 -120 sq mm cable size complete all as specified and directed.
All as per item No. 17 above but cable size 25 - 50 sq mm cable size complete all as specified and directed.
Taking out any steel/ RCC pole of any size complete all as specified and directed.
Supply, erecting & fixing steel tubular swaged pole complete with base plate, pole cap, nut bolt washer etc 8.5 meters long type 410 SP-22 swaged poles conforming to IS 2713 (Part-I to III) 1980 all as specified including two coats of black bitumen paint through out internally and externally upto planting depth and applying two coats of aluminum paint over one coat of red oxide primer (externally) and Numbering of poles as directed including excavation /earth work, PCC 1:4:8 type D-2 using 40mm aggregate for pole foundations of size 600 x 600 x 1500mm height upto ground level and using PCC 1:2:4 B-1 for coping with size 450 x 450 x 300mm including necessary formwork complete with taking down old unserviceable pole complete all as specified and directed.
S&F in repairs thermoplastic cable entry junction boxes of size 250 x 220 x 135mm and IP-65 protection level with metric knock out fixed on poles with MS clamps, nuts, bolts and washers including MCB SPN, 5-32 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc., separate (detachable) gland plate, bakelite connector 4 way 20 amp, dust and vermin proof, front door opening with hinges and locking arrangement, complete all as specified and directed. Make:- Sintex/ Hensel or equivalent
S&F in repair 60 Watt LED street light comprises of pressure die cast aluminium housing with frame and toughned glass cover, ALL LEDS are tier 1 LEDs with individual lens, input voltage working range is 140Vac to 270 Vac, driver is used with 4KV internal sure protection , short circuit protection, open circuit protection, High & low voltage protection, Fixture is IP65 PROTETED & ik 05 protected, THE<10% cct 5700+/-300k , PF>0.9,cri>75 complete all as specified and directed. Make:- Jaquar cat No. LSRTO15660XC or equivalent in Wipro, Philips.
S&F in repair 200 Watt LED flood light comprises of pressure die cast aluminium housing with frame and toughned glass cover, ALL LEDS are tier 1 LEDs with individual lens, input voltage working range is 140V ac to 270 V ac, driver is used with 4KV internal sure protection, short circuit protection, open circuit protection, High & low voltage protection, Fixture is IP65 PROTETED & ik05 protected, THE<10% cct 5700+/-300k , PF>0.9, cri>75 complete all as specified and directed. Make:- Jaquar cat No. LSRTO15660XC or equivalent in Wipro, Philips.
S&F in repair LED driver for 60W LED street light fittings complete all as specified and as directed.
S&F in repair LED driver for 45W LED street light fittings complete all as specified and as directed.
Taking down the unserviceable LT Panel of any size with all accessories complete all as specified and directed.
Supply, install, test and commissioning of LT panel board / feeder pillar box, outdoor cubicle type, vermin proof, dust proof (of CPRI approved manufacturer), fixed on 50x50x5mm MS angle iron frame fixed 300mm above ground level and 450mm below the ground level grouted in and including PCC 1:3:6 type C1 (using 20mm grade stone aggregate) and plane made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm hick for inner shell both side open able supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arrangement and fixing arrangement i.e nuts, bolts, washers, clamps etc, with naturally air cooled epoxy insulated aluminium busbar TPN suitable for 300 Amps with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete,all control cables shall be of 2.5 Sqmm copper multi stranded conductors and shall be properly bunched with suitable size binding materials , ferruled for proper identification of colour codes and crimped with adequate size of lugs also to accommodate and consisting of the following items complete all as specified and directed. (a) Busbar chamebr for 3 phase & nuetral of capacity 300 Amps (30mm x 10mm) alumunium bus bar duly insulated, (b) Multifunctioning meter to measure Voltage, ampere, KWH, PF -1 Nos (c) one set of pilot lamp. (d) Incoming MCCB 160 amps 4 Pole 415 volts 25 KA thermal magnetic setting type- 1 Nos (e) Outgoing MCCB 63 amps 3 pole 415 volts 10 KA thermal magnetic setting - 5 Nos (f) Outgoing Type MCB 63 amps 3 Pole 415 volts 10 KA - 2 Nos
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use within 50m complete all as specified and directed.
Dismantling insulators any type, any size complete all as specified and directed.
Dismantling stay assembly (demolition of concrete, etc. and excavation will be measured separately) complete all as specified and directed.
Dismantling of ACSR or AAC conductors complete all as specified and directed.
S&F in repair MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed.
S&F in repair MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed.
S&F in repair MCCB 4 Pole, 415 V, Adjustable type, 350 Amps with breaking capacity 50 KA complete all as specified and directed.
M&L for PCC 1:2:4 with 20mm aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings complete all as specified and directed.
M&L for rendering 15mm thick plaster on fair faces of brickwork or concrete surfaces in CM 1:6 and finishing the surface even and smooth complete all as specified and directed.
M&L for mild steel fabrication works such as angle / FI clamp, Ms pipe nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape and size etc including two coats of synthetic enamel paint cover a coat of red oxide primer complete all as specified and directed.
M&L for cleaning of sub station area by uprooting all types vegitation, shrubs, weeds, saplings and creepers of unwanted trees complete with the help of spade, axes, crowbars and other mechanical means after taking necessary electrical shutdown from concerned incharge of various sub stns of Military stn Kamptee complete all as specified and directed.
Trimming of tree branches touching of over head elecctrical lines upto 2.5 mtr distance from conductors after taking necessary shutdown from concerned incharge complete all as specified and directed. Note:- Space beteen poles will be measured as one unit irrespective of nos of conductors.
M&L for loose filling with aggregates of gauge 40 to 80 mm crushed stone back colour suitable for spreading in electrical sub stn after preparation of site by removing all type of debris, removing unwanted soil and spreading lime powder beneath the aggregate complete all as specified and directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.86,625.00]
Chinmaya Enteprises
Vaidehi E Link
M/S JAINENDRA KUMAR JAIN
M/S. ELECTROPOWER TECHNOLOGIES
Bidder Name
Paragon Electrotechnics
Chinmaya Enteprises
Vaidehi E Link
M/S JAINENDRA KUMAR JAIN
M/S. ELECTROPOWER TECHNOLOGIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .