Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC 197 PATHAK PARA ROAD KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹38.3 L+₹1.1 L (3.04%)Rejected-Finance 0 KALIKAPUR KALIKA PUR CHAMPAHATI SOUTH 24 PARGANAS WEST BENGAL 743330 | 24 PARAGANAS SOUTH | WEST BENGAL | 743330 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹39.0 L+₹1.9 L (5.06%)Rejected-Finance B4 60 1 NEW SANTOSHPUR THANDER PARA STATION ROAD 24 PARGANAS SOUTH PIN 700142 WB | 24 PARAGANAS SOUTH | WEST BENGAL | 700142 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹39.3 L+₹2.1 L (5.66%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹40.3 L+₹3.1 L (8.46%)Rejected-Finance 72 A ABINASH CHANDRA BANERJEE LANE KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹33.9 L
EMD Value
₹67,800
Closing Date
10 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR TO COOK HOUSE BLDG NO BI-4/F-1 INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA.
2023_MES_592373_2
8102/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹67,800
21 Jun 2023
3 Jun 2023
12 Jun 2023
3 Jun 2023
10 Jun 2023
3 Jun 2023
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Demolition of Brick work / stone masonry built in cement mortar and removing the debris from MD land complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for.
Dismantling asbestos cement (corrugated, semi-corrugated, etc) sheets in roof coverings.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including roof coverings.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar.
Dismantling wrought iron or mild steel work of any description not other wise provided for.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil.
Excavation in trenches, n.exc 1.5m wide and n exc 1.5m depth for foundation etc or for shaft wells ,cesspits ,manhole, pier holes nexc 10 sqm on plan and n exc 1.5m in depth and getting out in soft loose soils.
M&L for Hardcore of broken stone of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface all as specified
Returning filling in incl spreading levelling watering and wall ramming in layers not exceeding 25cm in soft/loose soil.
Removing excavated soil exc 250m but n.exc 500m and depositing where directed.
Removing excavated soil exc 1.5km but n.exc 5.0 km and depositing where directed.
Cutting holes in brick walls in cement mortar for inserting holdfast or pipes and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick, etc complete all as specified and directed.
M&L for brick work with fly ash brick straight or curved on plan exc 6.0 mtr mean radius built in 1:6 cement mortar, complete all as directed
M&L for Brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4, complete all as directed
M&L for brick work with fly ash brick straight or curved on plan to any radius in half bricks thick walls, built in 1:4 cement mortar complete all as directed.
M&L rendering 15 mm thick on fair faces of brick work/concrete surfaces in CM 1:6, finished fair & even & smooth without using extra cement, all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work/concrete surfaces in CM 1:4, finished fair & even & smooth without using extra cement.
M&L rendering 10 mm thick on fair faces of brick work/ concrete on ceiling surfaces in CM 1:3, finished fair & even & smooth without using extra cement.
M&L rendering 15 mm thick on fair faces of brick work/concrete surfaces in CM 1:4, using water proofing compound, finished fair & even & smooth without using extra cement. (Note:WPC shall be measured and paid separately).
Supply only liquid water proofing compound of Make Pidilite or equivalent, all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm stone aggregate) as in base or foundation filling and mass concrete complete as specified and directed.
M&L for PCC type C-2 1:3:6 (using 40 mm stone aggregate) as in surface channels and drains, all as specified.
M&L providing cement concrete1:2:4, type B-1 (using 20 mm graded stone aggregate) using cills, steps, plinth course, string course, coping and other similar bands etc complete all as specified.
M&L extra for forming fair finished drain or channel 60 cm girth in cement concrete, using extra cement including forms, moulds, mitred, stopped ends etc complete all as specified.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking bending spirally for lintels and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, all as specified.
S&F form work to soffits of suspended slabs such as slabs, floor slabs landings and similar work, not exceeding 200 mm thick (Horizontal or sloping), all as specified.
M&L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC/PCC bands in walls horizontal or slopping and similar work exc 10 cm but n.exc 20cm wide, all as specified.
M&L RCC (nominal mix) type B1 1:1½:3 (using 20 mm graded stone aggregate) for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.
S&F in repair RCPC (Reinforced Cement Polymer Concrete) grating slab of size 900 mm x 450 mm x 75 mm thick, of Capacity 5 MT fixed in proper position complete as directed by Engr-in -Charge.
Cutting into existing manholes for connecting new drain of 150 mm dia and over, making good to pipes and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1, smooth finished, and reforming benching as required, complete all as specified and as directed.
S&F cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole cover, fire and soot door, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles exc 5 kg each, complete all as specified and directed.
M&L cement concrete type C2 (1:3:6) using 40 mm graded stone aggregate, 75 mm thick as in plinth protection, laid in alternate bays, finished even and smooth without using extra cement, complete all as specified and directed.
M&L Non Skid joint free coloured digital tiles, minimum 7 mm thick, area of each tiles exc 0.16 Sqm but n.exc 0.38 Sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and incl 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as a specified and as directed
All as per item No.36 above, but as in vertical surfaces or in skirting, fixed over and incl 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350x250x 7mm/ 450x300x7 mm thick or as required size of 7 mm thick as on vertical surfaces such as wall, dado, skirting etc., set and jointed in neat cement slurry and pointed with coloured cement to match colour of tiles, laid over and including 10mm thick rendering in cement mortar 1:3, complete all as specified and as directed.
M&L for machine cut Kota stone slab flooring 18-20 mm thick, laid over and including 20mm thick screed bed in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
M&L for laying and fixing Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick rendering in cement mortar 1:4 and jointed etc complete all as specified and directed.
M&L mirror polishing on marble/granite/kota stone/stone work where ever required to give high gloss finish complete all as specified and directed.
M&L for 18-20 mm thick Black granite slab of approved quality of size exec 0.50 sqm but not exceeding 1.50 sqm each set and jointed in white cement laid over and including 20 mm thick screed bed in CM (1:4) including granite polish to be done by mechanical grinder not by hand complete all as specified and as directed.
M&L for 50 mm thick PCC type B1 1:2:4 (20 mm stone aggregate), finish even and smooth without using extra cement, all as specified.
M&L for Sand filling using as cushioning for floor finishes including watering and consolidation, all as specified and directed.
M&L for heavy duty coloured ceramic floor / paving tiles of size 300 x300x 10 mm thick in floor etc set and jointed in near cement slurry and pointed in white or coloured cement to match the shade complete including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed of Make : Johnson model Endura or equivalent model in other approved makes.
M&L 25 mm thick pre polished coloured chequared tiles of size 300mm X 300mm, jointed & pointed in neat cement slurry with white or coloured to match the shade of tiles, laid over & incl 20 mm thick screed bed in cement mortar 1:6 complete all as specified & directed.
M&L for laying pre-polished 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. (NOTE: Cost of sand cushioning is deemed to be included in the quoted rates)
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required complete all as specified.
Taking down chowkats or frames not exc 1.5 Sqm each but with shutters (without taking off shutters from the frame), all as directed.
All as per item No 49 above, but exc 1.5 Sqm but n.exec 4 Sqm each.
S&F of size (105x60) mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
Supplying and installing uPVC- Sliding windows/doors made out of lead free green profiles having a worldwide presence with a GREENLINE mark having two tracks and two sashes (shutters) with stainless steel fly mesh with frame dimension of 58mm x 49mm and sash dimension of 61mm x 47mm x 37mm with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm.The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weather ability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of ironmongery in Ist quality (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and also scaffolding if required for fixing is deemed to include in the rate quoted. (Note: The unit rate quoted by contractor excludes cost of glass and powder coated aluminium grill and includes all other connected accessories. Net opening will be measured for payment purpose. Glass and powder coated aluminium grill will be measured and paid separately under respective items)
M&L for factory made Second class hardwood glazed and Skelton shutters 35mm thick, open rebated and prepared to receive glass, gauze etc with sash bar any number fitted with cut and mitered beads for securing glass gauze etc , sizes of members of shutters as specified in SSR Part I section 8, Section 8.24(a) and fitted to chowkats, all as specified and as directed.
S&F factory made single extruded WPC (Wood Polymer composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
S&F Butt Hinges medium weight cold rolled mild steel 100mm long complete all as specified.
S&F aluminum anodised barrel tower bolts of extruded section 200mm long complete all as specified and as directed.
S&F Aluminum aodised sliding door bolts of 300mm long with hasp and staple(bolt type) and fixing clips of sheets ,cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
S&F Aluminum anodised bow handle fabricated type extruded section of 150mm long complete all as directed
M&L for Mild steel small articles such as flat iron 25x3mm thick for hold fasts etc conforming to Fe 410-0, or 310-0, all as specified and as directed.
S&F 150 mm over all length of cover plate of floor door stopper of Brass body and tongue, anodised with hard drawn steel spring fixed in floor.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, all as specified.
Supply & fixed in repairs Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, all as specified.
M&L 5 mm thick Toughened glass as in hinged doors, partitions, windows, automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified.
M&L Preparing new Surfaces of walls and applying Three coats of white wash with brush complete all as specified and as directed.
All as per item No 64 above, but on ceiling.
M&L for complete removal of existing treatment of old surfaces of walls and applying three coats of white wash with brush complete all as specified and directed.
All as per item No 66 above, but on ceiling.
M&L for complete removal of existing treatment of surfaces of walls, and applying two coats of acrylic distemper with roller over a coat of alkali resistant primer as per manufacturer's instructions and 1mm thick wall care putty, complete all as specified and directed.
All as per item No 68 above, but on ceiling.
M&L for cleaning new plastered surfaces of walls, soffits of chajja, roof slab etc, using emery paper, putty blade/scraper as applicable for removing loose paint, corosion, algae formation etc complete with one coat of 2mm thick exterior wall care putty through out and applying two coats of weather proof exterior emulsion paint over one coat of suitable exterior primer with rollers, including necessary scaffolding, safety and protective measures for upto 4 storey building height complete all as specified and directed.
M&L for complete removal of existing old treated surfaces of walls, soffits of chajja, roof slab etc, by scrapping as required using emery paper, putty blade/scraper as applicable for removing loose paint, corosion, algae formation etc complete with one coat of 2mm thick exterior wall care putty throught and applying two coats of weather proof exterior emulsion paint over one coat of suitable exterior primer with rollers, including necessary scaffolding, safety and protective measures for upto 4 storey building height complete all as specified and directed.
M&L preparation new plastered/concrete surfaces and applying two coat of synthetic enamel paint over a coat of primer, all as specified.
M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer.
M&L for preparation of new steel and iron surfaces of any description, n.exc 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer.
M&L for preparation of new wooden surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer.
Taking down and re-fixing old steel tubing 15mm bore and connection in new or old position(wall, ceiling, floor etc.) after properly cleaning incl necessary scaffolding complete all as specified and directed.
All as per item No.79 here-in-before, but 20 mm bore
S&F 5mm bore galvanised steel tubing (medium grade) with all fittings and fixed concealed to walls and ceilings or laid in floors incl necessary scaffolding as required at site, complete all as specified and directed.
All as per item No.81 here-in-before, but 20 mm bore
Disconnecting existing water tanks exc 500 & n.exc 1000 ltr of capacity, setting aside (or lowering if required) for repairs,etc and hoisting if required re-connecting and re-fixing in position after cleaning and removing all scale and dirt etc from tank and from mouths of circulating pipes etc all as specified. (Note : Date of cleaning deemed to be include in quoted rate).
All as per item No 82 above, but exc 1000 ltr &n.exc 2000 ltr of capacity.
Supply, hoisting and fixing rotational moulded polyethylene water storage tank (cylindrical vertical type with closed top) of capacity 1000 Litres, multi-layered (ISI marked), with GI tank nipple & cover, hoisted and fixed in position all as specified in SSR Part-I incl dismantling of existing unsv tank complete all as specified and directed. (NOTE: GI long screw shall be measured and paid separately)
All as per item No 84 above, but 2000 ltr of capacity.
S&F in repairs 25 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms).
Dismantling of 100mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and directed.
Dismantling of 150mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and directed.
S&F 100 mm bore cast iron (sand cast) soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls complete all as specified.
S&F 150 mm bore cast iron (sand cast) soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls complete all as specified.
S&F 100 mm bore cast iron (sand cast) soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified.
S&F 150 mm bore cast iron (sand cast) soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified.
S&F 100 mm dia CI branch pieces complete all as specified.
S&F 100 mm dia CI bend complete all as specified.
S&F 100 mm dia CI branch pieces with ovel access door complete all as specified.
S&F 100 mm dia CI bend with ovel access door complete all as specified.
S&F for cast iron floor trap/nahani trap with grating including jointing to waste pipes in cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate ,100mm dia outlet complete all as specified .
S&F 150 mm bore CI (sand cast) bend any radius, diminishing pieces or tapers complete all as specified.
S&F 150 mm dia CI (sand cast) branch, with or without ears, complete all as specified.
S&F stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stay, including bolts and nuts and securing ends of stays to wall or roof of 100 mm dia of pipes.
All as per item No.100 above, but 150 mm dia of pipes.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured Galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile Galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile Galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
All as per Item No.102 above, but 0.50 mm thick coloured plain Galvalume sheet as in ridge/valley gutter of roof.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
S&F for Framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, and for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.all as specified.
S&F for expanded metal, cut to length, bent to shape, required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples, weight exceeding 4 Kg/Sqm, complete fixed to steel members, all as specified and directed.
S&F Mild steel wind ties for roof including securing bolts, posts including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar work conforming to Fe 290 Gde E-165.
S&F 0.80mm mild steel, plain, black sheet in hearths, covering to door shutters, covering to door chowkats (frames), chullah hoods, water tanks, water troughs ducts, urinal troughs and funnels, etc cut to size edges beaded if directed, holes punched including round headed screws, clout nails or rivets and fixed to wood or steel members, etc with plain 40 mm lap joints or welded/ riveted seams including bending turning up, mitred angles, stopped ends, outlets etc as required, sheeting welded to frame as in repairs, complete all as specified and directed.
Taking down/removing of existing water proofing treatment on roof surfaces and wall surfaces complete, including screed bed, racking out joints, hacking for key scrubbing down with water etc including dismantling of lightening strip and refixing the same in position, and removing rubbish out from MD land, all as directed. (Note :- Dismantling and refixing of the lightening strip is deemed to include in the rate quoted if any).
M&L for spreading / brushing neat cement slurry with 3.00 Kg/ Sqm on old concrete surface all as directed.
M&L PCC type B-0 (1:2:4) (using 12.5 mm graded stone aggregate) thickness as required at site) for padding concrete as on roof, all as specified and directed by Engineer-in-Charge.
M&L for screed bed 15 mm thick (average) plaster on concrete surfaces in CM (1:3) on roof, mixed with water proofing compound and finishing the surface even and smooth without using extra cement all as specified and directed (Water proofing compound shall be measured and paid separately).
M & L for water proofing treatment on existing cleaned RCC roof with the following specification and manufacturing's instruction complete all as specified and as directed:- (a) Preparing and clening of fully dry surfaces as per IS3067-1966 (b) Applying bitumen primer conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm (c) Applying a layer of APP based polymeric membrane 3.0mm thick (minimum) weight 3.0Kg per sqm (reinforced) with polyester Non woven fabric weighing not less than 160gms per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of solar reflective bituminous aluminium paint @0.10 ltr per sqm over APP based polymeric membrane.
Cutting grooves in brick wall, 75mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3.
M&L bituminous gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces, all as specified and directed.
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs, beams, columns, lintel, chajja, fins, facia etc. of 50 mm average thickness (Any storey/ height of building/ structure) including tapering all edges, making square shoulders of cavities by air or sand blasting etc and cleaning of exposed concrete surface and reinforcement bars, lightly picking materials by air blasting or sand blasting including removal of foreign materials, loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed. (NOTE: Measurement shall be considered for the surface area of RCC member)
M&L for applying chloride free rust removing chemical on rusting steel reinforcement bar as per manufacturer's specification and removing all rust from steel reinforcement bar by wire brush & sand/emery paper (after 24 hours of application of rust remover) and cleaning the area thoroughly by water with the help of pressure jet and allowing it to dry and making the reinforcement bar totally rust free (for any storey/ height of building/ structure) complete all as specified and as directed. (Make of Rust removing chemical :- Reebaklens RR of FOSROC or equivalent product other makes specified in tender) (NOTE: Surface area of cleaned steel reinforcement shall be measured for payment)
M&L for introducing new mild steel TMT reinforcement bars for structural connection in RCC beams, columns, lintel and slabs (for any storey/ height of building/ structure) including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges, plastic nozzles etc as per manufacturer's instructions etc all as specified and directed. (Make of epoxy chemical :- Lockfix E75 of FOSROC / Hilti HY 150 or equivalent product other makes specified in tender) (NOTE: Reinforcement bars shall be paid separately)
M&L for preparation of old existing corroded and new introduced reinforcement surface (at any storey/ height of building/ structure) by brush and application of two component epoxy based zinc rich primer, of minimum specific gravity 1.75, adhesive bond strength with steel as 1.50N/mm2, as a protective coating to steel reinforcement bars in concrete with total zinc content in dry film >90% by volume and DFT per coat >50 microns complete all as specified and directed. (Make- Nitozinc primer of FOSROC or equivalent product in other makes specified in tender) (NOTE: Surface area of steel reinforcement shall be measured for payment)
M&L for applying a coat of epoxy bonding agent on existing concrete surfaces, with mixed density 1.48 Kg/litre and adhesive bond strength>2.50 MPs, mixed and applied as per manufacturer's specifications complete all as specified and directed. (Make- Nitobond EP of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for applying shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar, as per manufacturers instructions to get a compressive strength of 35 MPA after 28 days, finishing surfaces even and smooth complete all as specified and directed. (Make- Rendroc SP 40 of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
GENERAL NOTES FOR ITEM NO.117 TO 122 :- (i) The work shall be got executed through authorised applicator of the chemical manufacturers. Necessary documents to this effect shall be obtained from manufacturer and submitted to the Engineer-in-Charge. (ii) Contractor shall provide additional manpower, resources, preparatory work etc. required for execution of the work as required by the authorised applicator. Quoted rates are deemed to be inclusive of the above aspects. No extra claim shall be admissible during execution of work on this account.
SCHEDULE 'A' PART-II (ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for reuse or removing from site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No.125 above, but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No.125 above, but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No.125 above, but using 2.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLSH PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No.125 above, but using 4.0 Sqmm single core multi stranded copper conductor FRLSH PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 4.0 Sqmm green FRLSH PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch piano flush type 16 Amps, one way complete all as specified and directed.
S&F socket outlet 6/16 Amps, 6 in 1, flush type complete all as specified and directed.
S&F electronic type stepped speed regulator, 100 watts, AC 230 Volts for ceiling fan, complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/Bakelite, three terminals complete all as specified and directed.
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate diffuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
S&F in repairs LED Street Light/Bldg Security light fitting, 30 Watt, 240 Volts, in pressure die cast aluminium housing with lens and toughened glass cover with integrated constant current electronic driver, having ingress protection of IP 66 and impact resistance of IK 07 complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 105 lumen/watt (b) CRI not less than 70, (c) THD < 10% (c) having in built short circuit and surge protection upto 4 kV (d) colour temperature not less than 5700 degree K (e) life not less than 50,000 hours of operation (f) Power factor > 0.95 (NOTES: (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Quoted rate is deemed to be inclusive of dismantling of existing bracket. (3) Wire for electric connection of new fitting and new GI pipe bracket shall be measured & paid separately.
S&F sub main wiring with 4 runs of single core FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 Sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 Sqmm as earth continuity conductor drawn through and incl concealed PVC conduit of suitable size complete all as specified and directed. (NOTE : Four run of single core 10.0 Sqmm cable & one run of PVC conduit shall be measured as one unit)
S&F sub main wiring with 2 runs of single core FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through and incl surface/concealed PVC conduit of suitable size complete all as specified and directed. (NOTE : Three run of single core 6.0 Sqmm cable & one run of PVC conduit shall be measured as one unit)
S&F sub main wiring with 2 runs of single core FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and incl surface/concealed PVC conduit of suitable size complete all as specified and directed. (NOTE : Three run of single core 4.0 Sqmm cable & one run of PVC conduit shall be measured as one unit)
S&F MCB DB VTPN 4 way, IP 43 protection, double door (premium quality), 415 volts, (without MCCB) with 200 Amps copper bus bar for each phase complete all as specified and directed. (MAKE :L&T / LEGRAND / C&S/SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB DB TPN 4 way (8+12), IP 43 protection, double door (premium quality), 415 volts, with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE :L&T / LEGRAND / C&S/SCHNEIDER / ABB / PANASONIC / HAGER)
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium Quality), for mounting of MCB for 240 Volts, SPN 8 way, with 100 Amps rated copper bus bar, complete all as specified and directed. (MAKE :L&T / LEGRAND / C&S/SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB DB SPN 4 way , IP 43 protection, Double Door (Premium Quality), with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE :L&T / LEGRAND / C&S/SCHNEIDER / ABB / PANASONIC / HAGER)
NOTE FOR ITEM NO.142 TO 145:- (1) Incoming MCB and outgoing MCBs shall be measured and paid separately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB & MCB shall be of the same manufacturer.
S&F MCCB (premium range), 4 pole, 100 Amps, 16 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed. (MAKE :L&T / LEGRAND / C&S/SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (premium quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA, complete all as specified and directed. (MAKE :L&T / LEGRAND / C&S/SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (premium quality), 'C' series, SPN, 40 to 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE :L&T / LEGRAND / C&S/SCHNEIDER / ABB / PANASONIC / HAGER)
S&F in repairs single pole enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps, 'C' Curve, 10 KA including all accessories complete all as specified and directed. (MAKE OF ENCLOSURE: LEGRAND, Cat No. 5078 10 / L&T, Cat No. DBMPS120SD / SCHNEIDER, Cat No: A9HMS220 / ABB, Cat No. NSYN8690SGKSP20 / C&S, Cat No: CSDBPSSPN020 / BCH, Cat No: BCHPSDBSPN20 / HPL, Cat No: MDBSP20 / HAGER, Cat No: VYA220Cor equivalent model in Havells / Indo Asian ) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate)
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
GHOSH ENTERPRISE
DGR CONSTRUCTION
JOY RAM ENTERPRISE
MS HORIZEN
PRABIR TRADERS
DEB AND COMPANY
MS AP CONSTRUTION AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .