Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC N S T COLONY CIRCULAR ROAD HOUSE NO 04 DMC DIMAPUR 797 112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹12.0 L+₹1.8 L (17.8%)Rejected-Finance NEAR RAM JANAKI HIGHER SECONDARY SCHOOL H NO 03 THAKURBAR DIMAPUR NAGALAND 797112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹18,400
Closing Date
6 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Zakhama
C/o 792 FPO PIN-900792 C/O 99 APO
REPAIR/REPLACEMENT OF ELECTRIC POLES, LT OVERHEAD LINES , CABLES, FEEDER PILLARS AND ITS ALLIED WORKS AT ZAKHAMA MIL STN UNDER AGE (I) ZAKHAMA
2023_MES_612326_1
8177/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Zakhama
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Zakhama
₹18,400
9 Oct 2023
5 Aug 2023
9 Sept 2023
5 Aug 2023
6 Sept 2023
19 Aug 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cables, foundation for pole, etc and getting out in hard/dense soil complete all as specified and as directed.
All as per item No.1 here in before but depth exceeding 1.5 m but not exceeding 3m.
Returning, filling in, including spreading, levelling, watering and well ramming of soil in layers n. exc 25cm thick complete all as specified and as directed.
Removing excavated soil to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed.
M&L for erection and fixing of steel tubular swaged pole type 410 SP - 31 (9.00 metres long) confirming to IS- 2713 Part I to III 1980 with and including cast iron base plate, finial taper plug, nuts, bolts and washers etc. fixed in PCC foundation duly painted painted with two coats of Aluminium paint over a coat of red oxide primer including preparation of surface and including dismsntling of old pole of any size and description with foundation, PCC coping etc. complete all as specified and as directed.
M&L for PCC 1: 2 : 4 type B-1 using 20 mm graded stone aggregate including necessary form work for coping to the new/ existing Steel Poles complete all as specified and as directed.
M&L for PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping for the new/existing Steel Poles, cills, including necessary formwork (straight or curved) complete all as specified and as directed.
M&L for preparation of old painted surface of 9/11 metre long steel pole with cross arms and brackets and two applying two coats of aluminium paint and writing pole nos with synthetic enamel black japan paint at a height of 1.5 mtr above ground level and black and yellow strips of 30cm each 3 nos complete all as specified and as directed.
All as per item serial No 09 here-in-before but for double pole structure complete all as specified and as directed.
M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting with one coat of aluminium paint over a coat of red oxide primer including taking down the old unserviceable cross arms, clamps etc complete all as specified and as directed.
M&L for ACSR conductors (weasel type) for LT OH lines on poles including stringing, binding with aluminium wire 14 SWG or aluminium tape including jumpers complete connecting of disconnected cable, service cable and street light connection including taking down the old unserviceable ACSR conductor of any type complete all as specified and as directed.
Material and labour for restringing, tightening of loose/broken ACSR conductor of any size and type, maintaining standard sag including binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc on HT/LT over head lines complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 95 sqmm 3½ core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking down old unserviceable UG cable any type complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 50 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking down old unserviceable UG cable any type complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 4 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking down old unserviceable UG cable any type complete all as specified and as directed.
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)
Supply and laying well burnt sub class ‘B’ bricks locally available best quality laid dry in trenches for protection of underground cable all as specified and directed
M&L for GI pipe light grade 40mm bore with all fittings laid in trenches or in floors, including taking up/ down old pipe complete all as speciffied and as directed.
M&L for GI pipe light grade 80mm bore with all fittings laid in trenches or in floors, including taking up/ down old pipe complete all as speciffied and as directed.
S&F in repair for cable jointing kit for LT (Earthed) grade cable for end termination outdoor/Indoor heat shrink type joint complete with jointing material and accessories suitable for for aluminium Conductor cable size 25-50 Sqmm 3.5/4 core complete all as specified and as directed.
S&F in repair for cable jointing kit for LT (Earthed) grade cable for end termination outdoor/Indoor heat shrink type joint complete with jointing material and accessories suitable for for aluminium Conductor cable size 70-120 Sqmm 3.5/4 core complete all as specified and as directed.
S&F in repair for cable jointing kit for LT (Earthed) grade cable for straight through joints outdoor/Indoor heat shrink type joint complete with jointing material and accessories suitable for for aluminium Conductor cable size 25-50 Sqmm 3.5/4 core complete all as specified and as directed.
S&F in repair for cable jointing kit for LT (Earthed) grade cable for straight through joints outdoor/Indoor heat shrink type joint complete with jointing material and accessories suitable for for aluminium Conductor cable size 70-120 Sqmm 3.5/4 core complete all as specified and as directed.
S&F in repairs, LED polycarbonate unbreakable round doom gate light for gate/garden including LED bulb 10 watt complete all as specified and as directed. Make Havells Cat No LHFXAMN1TN6F035 or equivalent model of make Philips/Bajaj/crompten
M&L for earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I including demolition of old earthing complete all as specified and directed.
M&L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetcedusing galvanised iron strip 25×4mm as earthing lead by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including demolition of old earthing completion all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Taking down defective street/ flood light fittings of any wattage from height upto 11metre pole for repairs and refixing the same,after removing the carbon/ deposit forein materials to make fuctional, replacing defective accessories like LED driver, SPD, PVC insluted sheathed copper conductor etc if required complete all as specified and as directed. (Note :For New spare parts/components of street light fittings shall be measured and paid separately under respective items as supply only however, screws, insulation sleeves, nuts, bolts, washers and PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmm X 3 core from light fitting to Street light feeder (max 1.5 metre ) deemed to be included in quoted rate.)
S &F street light fitting of 90 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500, IP66, impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage including taking down old unserviceable light fittings complete all as specified and as directed. (Make :- Century Ltd Magic Cat Part No.SPBL090C2111 or equivalent in Philips/Havells/Crompton)
Supply only constant current LED driver suitable for LED luminaries of wattage of 40W/45W complete all as specified and as directed. (Make- Bajaj / Surya/ Havells / C&S/Magik)
Supply only constant current LED driver suitable for LED luminaries of wattage of 60W complete all as specified and as directed. (Make- Bajaj / Surya/ Havells / C&S/Magik)
Supply only constant current LED driver suitable for LED luminaries of wattage of 90W complete all as specified and as directed. (Make- Bajaj / Surya/ Havells / C&S/Magik)
S&F in repair LED Bollard light 9w LED warm white 230V, AC cylindrical shaped integral decorative LED bollard with opel acrylic diffuserand IP-65 protection including taking down old light complete all as specified and as directed. Make Bajaj cat BGBOL 605 9W LED WW or equivalent model of Philips/crompten/ havells.
S&F in repair 2.5 Sqmm, 3 core Pvc Insulated & Sheathed Copper Flexible Cable Black including condute pipe complete all as specified and directed .
Supply, install, testing and commissioning of LT feeder pillar box of approx size 900mmx600mm x 450mm "out-door type" factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-66 & general construction confirming to IS-13947 double door, front and back openable . The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & Alumiunum bus-bar wrapped with colour PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) CRCA sheet duly pre-treated & powder coated , supporting angle iron frame & MC channel base suitable for 3 Ph , 4 wire system 415/440 volts grade, complete internal wiring with not less than 2.5 sqmm copper wire including cable glands of suitable sizes including suitable PCC (1:3:6) type C-2 foundation and necessary earth work complete all as specified & as directed with & incl the following accessories :- BUS-BAR & INTERNAL CONNECTIONS:- The bus-bars shall be made up of 04 Nos high grade Aluminium 150 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidity mounted on suitable sized "F" class insulators of non-combustible ,all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY:- The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of cable glands matching the existing LT cable sizes. INCOMING:- (a) MCCB 4P (Ics = 100% Icu ) with thermal magnetic release , adjustable short circuit & adjustable over load setting , suitable for isolation, having breaking capacity 16 KA ,415 V & of rating 100 A - 01 Nos. OUTGOINGS:- (a) MCB SPN, 10 KA, 220 V & of rating 63A- 01 Nos. (b) MCB SPN, 10 KA , 220 V & of rating 32A- 05 Nos. INSTRUMENTATION SYSTEM:- (a) Indicator lamp with internal circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (b) Danger notice plate of size 20 x 15 cm of 1.6 mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back ). (c) Digital Amp meter 0-500 Amp with CT's - 01 Nos. (d) Digital voltmeter 96x96mm from 0- 500 volts- 01 Nos (e) Rotor switch - 02 Nos NOTE :- (i) Design / drawing / BOM of the Panel Board showing the dimensions is to be obtained from the manufacturer / Supplier & is to be got approved from AGE(I) before placing final order to the manufacturer. (ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. (iii) Rates are inclusive of taking out old existing LT feeder pillar box by disconnecting all electrical connections.
SHRIi Bachulal shah
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .