Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹10.0 L+₹1.0 L (11.7%)Rejected-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-AOC ELIGIBLE |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
12 Oct 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) NAGPUR
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007
Scanned copy of latest Service Tax/ GST Registration Number
2020_MES_373940_1
80412
Open Tender
Civil Works
Item Rate
60 days
GE (AF) Amla
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) AMLA
₹20,000
11 Dec 2020
1 Sept 2020
13 Oct 2020
2 Sept 2020
12 Oct 2020
28 Sept 2020
60 days
Amount
Material and Labour for Overhauling / repair of the compressor capacity 10 TR Model FK-4 (Kirloskar Make) by means of isolating the compressor from the system by putting dummy plates to the suction and discharge valves, dismantling of the compressor, separating into components, inspecting, cleaning all the parts completely, carrying out necessary machining work as may be required on the crank shaft, replacement of unserviceable parts. reassembling of the compressor, Leak testing of the compressor for 12 Hrs, charging of fresh compressor oil upto the necessary level and connecting the compressor with the system. Charging of refrigerant gas after putting the system on vacuum, running the plant and watching the performance for smooth running. NOTES :- (i) The cost of minor spares required including Gasket set, required is deemed to be included in the quoted rate. (ii) Spares incorporated during repair of the compressor will be measured separately under relevant item.
Supply only spares required for repair / overhauling of compressor Make : Kirloskar
Main bearing bush front end.
Main bearing rear end.
Valve Plate Assembly including suction and discharge reeds
Connecting rod as per site of suitable size
Piston with piston Pin & rings
Shaft seal assembly
Oil Pump Assembly
Connecting rod nuts & bolts of suitable size
Suction strainer
Taflon ring for Suction/ Discharge valve
Supply & fix in repairs ‘V’ belts of the following size all as directed Make – PIX / Fenner / Hilton.
B-70 (compressor motor )
B- 84 (cooling tower)
B-120 (Cooling Tower)
LP/HP Cut Out MP-15 Make : Indofoss/ Danfoss
Supply and fix in repairs water pressure cut out Type IPSD 50 including necessary control wiring with 2.5 Sq. mm multistranded copper conductor cable in flexible / rigid MS Conduit fixed to wall ceiling / wall / laid in floor. Make: Indofoss / Danfoss
Supply and filling of new compressor oil No - 68 suitable for AC Compressor of Make -Voltas (5F40) & Kirloskar (FK-4) Make : Castrol / Servo
Supply and Fix in repairs of angle Valve, brass 1/4" for return suction line including refixing as existing at site complete all as directed. Make : Castle ( or) Equivalent
Supply and fix in repairs Shut Off valve brass 1/4" bore complete with and including replacement of flair nut , nut and bolts all as directed. Make : Castle ( or) Equivalent
Supply & Fix in repairs of condenser safety valve, brass 0 to 350 PSI sealed of any size confirming to ISI including evacuation of refrigeration gas and recharging of taken out gas all as directed. Make - Castle/Henry/Brassomatic
Supply and fix in repairs suction, discharge ,oil and water pressure gauge 100 mm dia of the following range with necessary connections. Make Feibig / H Guru
0 to 200 PSI or equivalent in Kg/cm2.
0 to 300 PSI or equivalent in Kg/cm2.
(-) 30 to 200 PSI or equivalent in Kg/cm2.
0-4.2 Kg / sqcm.for water pressure Guage
Supply and fix in repairs Water Temperature Guage industrial Type 0- 50 Deg C. Make Feibig , H Guru Or equivalent
Supply and filling of new compressor oil polyster lubricant grade 160-SZ suitable for Scroll compressor of Make - Danfoss (SM185S4RC). Make : Danfoss/Emcorf (or) Equivalent
Taking down electric induction motors of following capacities after disconnecting incoming electric connection, & removing to work shop for repairs/ rewinding.Dismantling the motor, separating the parts such as rotor , stator, cleaning of all dismantled parts, taking down burnt / damaged winding cleaning the slots , packing the slots with insulated packing material, rewinding with super enameled copper winding wire of same guage varnishing the stator & drying in oven reassembling the motor complete with and including new packing material, new set of bearings, terminal plate, transporting back to plant room, material, new set of bearings, terminal plate, transporting back to plant room,
Upto 5 HP ( Condensor, CT fan pump motor)
Upto 7.5 HP (for AHU)
Upto 15 HP (for Compressor Motor)
Supply and fix in repairs CT fan roller bearing of size 30204 J2/Q Make : SKF/ NRB
Supply and fix in repairs Bearing for cooling tower motor 1.5 / 2 HP Make : SKF/ NRB
Supply and fix in repairs Ball brass valves, high pressure with Polyethylene float and fly nut complete screwed for Iron pipe or brass ferrule of size 20 mm dia
Supply and fix Pilot solenoid coil 3 way complete all as specified and directed. Make : As per sample
Material and Labour for descaling the condenser with hot water and chemical (HCL) and reassembling the condenser connecting up and testing including all opening, closing, testing and complete all as specified and directed by EIC . Note :Frequency of de-scaling will be on half year basis.
Supply and fixing Heating element threded type capacity 3KW as per sample (each row 3 heaters) proper fixing in heater box with opening , closing system of heater box complete all as specified and directed .
Supply and fixing Heating element threded type capacity 6KW as per sample (each row 3 heaters) proper fixing in heater box with opening , closing system of heater box complete all as specified and directed .
Supply and fixing in repairs dry & wet bulb thermometer mercury filled and graduated on tube including removing existing unserviceable thermometer all as directed. Make : USHA/ Dimple
supply and fixing canvas cloth for duct
Supply and fixing in repairs shaft seal assembly of condenser motor rating 5 HP of Make-Kirloskar including taking down of old U/S all as directed.
Supply and fixing in repairs PG-9 Sensor for chiller of Make -Voltas Limited and Model No 10039-3 all as directed.
Supply and fixing in repairs contactor MNX-25 all as directed. Make - L&T/Siemens/Legrand
Material and labour for over hauling of compressor unit 15 TR capacity make Voltas, model No -WCU015-OT by disconnecting the refrigerant system after pumping down the gas to other condensing units/gas cylinders and dismantling the compressor by strip open all accessories and parts. Decarbonising the metallic parts with approved CT solution/Maic solution. Check all parts and accessories its serviceability and authorized play, tolerance and limits. Reassembling the compressor unit after replacement NOTES :- (i) The cost of minor spares required including Gasket set, required is deemed to be included in the quoted rate. (ii) Spares incorporated during repair of the compressor will be measured separately under relevant item.
Supply only of the following (Items No. 22.01 to 22.10) :- Shaft seal assembly
Bearing Bush (Front)
Bearing Bush (Rear)
Half section bearing (set of two)
Connecting rod bolts & nuts
Piston with piston pin & rings
Suction valve ring plate
Discharge valve ring plate
Spring for unloading ring
Tyre coupling for Voltas compressor
Repair & relaying of Electrical interlocking wiring of LT panel of AC plant including all connected lux, cable, fuzes, complete all as specified and directed . NOTES :- (i) The cost of minor spares required including connector, lux, wire/cable, fuses required is deemed to be included in the quoted rate. (ii) Spares incorporated during repair of the electric panel will be measured separately under relevant item.
Push Button
KP-15 cutout Make:- Dafoss/Indfoss
Loading unloading coil
Contactors as per existing Make: L&T , Legrand
Timer 30-120 Sec. (L&T, Selec)
Relay 17.5-22 Amp Make -L&T Semans, Legrand
ALV D-2 single phase preventer Make :L&T/Minilec
MCB TPN 63 Amps, 10 KA Make -Siemens, Legrand, Hagger(L&T)
MCB SP 32Amps, 10 KA Make -Siemens Legrand, Hagger(L&T)
Relay, 5.5 - 8.5 Amps Make -Siemens Legrand, Hagger(L&T)
Relay, MN-2 10-25 Amps Make -Hagger(L&T), Siemens , Legrand
Digital type Ammeter 3 phase & CT coil (Make- Conzerv/Selec/ AE)
ON/OFF switch Make -As per sample
Digital type Voltmeter 3 phase (Make- Conzerv/Selec/ AE )
Indicator (R-Y-B ), 15mm dia, Neon type Make- As per sample
MCCB 63 Amp Model DU-100 Make:- L&T
ADD BLOCK suitable for existing contactor
supply and charging refrigerant gas R-22 in returnable cylinder Make:- Mafron/Freon.
Material and labour for cleaning of radiator fins of cooling coils and heating coils of AHU having Cfm rating from 13000 to 18000 Cfm with suitable chemicals complete as specified and directed by Engr-In-Charge.
Supply and charging refrigerant gas R-407c in returnable cylinder. Make - Mafron/Refron/Floron.
Supply and fixing, & commisioning in replacement of exisiting condensor pumps having capacity of 5 HP rating, 3 phase, 50 Hz, including taking down of old U/S pumps complete all as specified and directed. Make - Kirloskar, CG.
Supply and fixing, & commisioning in replacement of exisiting hot water monoblock pumps having capacity of 2 HP rating, 3 phase, 50 Hz, including taking down of old U/S pumps complete all as specified and directed. Make - Kirloskar, CG.
Supply and install in repairs including testing water cooled hermatically sealed scroll compressor of capacity 11/12 TR, three phase, UL electrical ratings 460 V3 - 60 Hz and 380-400 V3 - 50 Hz with thermally protected system including taking down old U/S compressor of Make - Danfoss and Model No. SM 18554RC complete all as specified and directed. Make - Danfoss/Compland or equivalent.
Supply and install in repairs including testing Air cooled hermatically sealed scroll compressor of 8.5 TR capacity, three phase, UL electrical ratings 460V3 - 60 Hz and 380-400 V3 - 50 Hz with thermally protected system including taking down old U/S compressor of Make Voltas/Blue Star complete all as specified and directed. Make - Danfoss/Compland or equivalent.
Supply, install, testing and commissioning water cooled condenser with max working pressure 120 PSI at tube side and 315 PSI at 150°F and pneumatic test pressure 150 PSI at tube side and 375 PSI at shell side suitable for water cooled scroll compressor of capacity 11/12 TR including taking down old U/S condenser of Make - Voltas and Model No 09016TX and deposite to MES yard complete all as specified and directed. Make - Danfoss/Voltas Limited or equivalent.
Supply and fix Brass Gate valve 40 mm dia bore screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of for union and fixed complete all as specified and directed by Engr-in- Charge. Make :- Zoloto,Seiko or equivalent.
Supply and lay MS pipe heavy grade class C of bore 40 mm including flanges, bends, tees, nipple, socket, reducer) including taking down old U/S gate valves complete all as specified and directed by Engr-in- Charge. Make : Jindal, Tata, Prakash Surya (i) Spares incorporated during repair ofpipe line will be measured separately under relevant item.
Supply only of the following (Items No. 33.01 to 33.04) :- Socket 15 mm dia
Flange 40 mm dia
Bend 40 mm dia
Elbow 15 mm dia
Supply and fix in replacement mono block pump set of cap 0.6 kw (0.75 hp), 560 LPH, 9 mtr head single phase, 240 volts suitable for humidifier system including taking down old U/S mono block pump complete all as specified and directed by Engr-in- Charge. Make :- Vguard/Lubi/Kirloskar
Supply and fix in repairs cast iron sluice valve of size 80 mm dia bore PN-1.6 with both ends flanged confirming to the IS-780/IS-14846 with brass spindle and iron wheel head including provision of rubber gasket, nuts and bolts etc, including taking down old unserviceable sluice valve complete all as specified and directed by Engr-in-Charge. Make - Kirloskar/SIR/BIR or equivalent.
Supply and fix copper fuse links of temperature rating 74°C for fire damper for supply air ducting including taking down old U/S fue links complete all as specified and directed by E-in-Charge.
Supply and Installation of fire damper of size 44.5"x24"x6.5" at least 90 minutes fire rating as per specification and approved shop drawings, complete with fusible link with spring return mechanism and limit switch to shut off AHU blowers when the fusible link to be 74°C rated all as directed. Make - Dyna/Airmax/Aerocon/Ravistar.
Supply and fix brass liquid valve of size 1/2" incl cutting, brazing and testing complete all as specfied and directed by Engr-in-Charge . Make - Brassomatic or equivalent.
Supply and Installation of control panel for all 06 Nos condensing unit controled with temperaure displayed in control box complete all as specified and directed by Engr-in-Charge.
Note:- The amount of schedule of credit on page No.32 shall be deducted from the amount quoted against sch 'A' while deriving at the contract sum for accptance.
Shri Sai Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .