| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹32.6 L+₹3.3 L (11.1%)Rejected-Finance | L2 | Rejected-Finance Awarded being 2nd Lowest Bidder | |
| 3 | L3₹33.6 L+₹4.3 L (14.7%)Rejected-Finance | L3 | Rejected-Finance Awarded being 3rd Lowest Bidder | |
| 4 | L4₹48.9 L+₹19.6 L (66.7%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Awarded being 4th Lowest Bidder |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
1 Nov 2023, 6:00 pmClosed
Major S K Yadav GE(S) BATHINDA
GE(S)Bathinda Bathinda Mil Stn
GE(S) BTD TOKEN NO 70 OF 2023-24 REPAIRS REPLACEMENT OF INTERNAL UNSERVICEABLE POINT WIRING REWIRING FITTINGS FIXTURES DBs SUB MAIN WIRING SWITCHES AND CONNECTED ACCESSORIES WORKS IN OLD NILGIRI ENCLAVE AND NEW NILGIRI ENCLAVE AND REPAIR TO SOLA
2023_MES_620669_1
GE(S)/BTD/TOKEN NO 70 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(S)Bathinda
Class D
category b(i)
11 documents required · 11 mandatory
₹500
GE(S)Bathinda
₹99,000
Yes
19 Dec 2023
26 Sept 2023
3 Nov 2023
26 Sept 2023
1 Nov 2023
17 Oct 2023
Amount
Taking down carefully existing copper/Aluminum point wiring (light,fan, socket or power) complete including fixture and fittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, callbells etc removiing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing complete allas specified and directed
Dismentaling & taking down of existing unsv light fittings/fixtures complete all as specified & directed
Dismentaling & taking down of existing unsv Lamp holder for replacement complete all as specified & directed
Dismentaling & taking down of existing unsv call bell for replacement complete all as specified & directed
Dismentaling & taking down of existing unsv batten/angle holder for replacement complete all as specified & directed
Dismentaling & taking down of existing unsv switch 5 Amp for replacement complete all as specified & directed
Dismentaling & taking down of existing unsv two way switch 5 Amp complete all as specified & directed
Dismentaling & taking down of existing unsv switch 15 Amp complete all as specified & directed
Dismentaling & taking down of existing unsv bell push 5/6 Amps complete all as specified & directed
Dismentaling & taking down of existing unsv socket 5A complete all as specified & directed
Dismentaling & taking down of existing unsv socket outlet 15 Amp complete all as specified & directed
Dismentaling & taking down of existing unsv switch socket combination 5/15 Amp complete all as specified & directed
Dismentaling & taking down of existing unsv stepped type fan regulator for complete all as specified & directed
M & L for Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed
One Socket outlet three pin, 6 Amp, on the same board, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified & directed
One Socket outlet three pin, 6 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed
One Bell/Buzzer point controlled by one push button with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed
One light point controlled by two two way switch. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed
One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed
One socket outlet three pin, 6 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit complete all as specified & directed
Note for serial item No 14.00 to 13.07: 1. Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. 2. GI boxes shall be fixed flush in position with cement mortar (1:4) complete all as specified & directed
S&F Switch modular type single pole, one way, 6 Amp, one module, complete all as specified & directed
S&F Switch modular type single pole one way, 16 Amp, one module, complete all as specified & directed
S&F Switch modular type single pole, two way, 6 Amp, one module, complete all as specified & directed
S&F Bell push switch modular type single pole one way, 6 Amp, one module, complete all as specified & directed
S&F Socket outlet modular type, multipurpose, 3 pin, single pole one way, 6 Amp, two module, shutter type complete all as specified & directed
S&F Socket outlet modular type multipurpose 3 pin, 2 in 1 single pole one way 6/16 Amp, two module, shutter type complete all as specified & directed
S&F in repair Modular telephone socket one module complete all as specified & directed
S&F Fan regulator, modular type, 5 step, high speed, two module complete all as specified & directed
S&F in repair Switch piano, flush type single pole, one way 5 Amp complete all as specified
S&F in repair Switch piano, flush type single pole, two way 5 Amp complete all as specified
S&F in repair Switch piano, flush type single pole, one way 15 Amp complete all as specified
S&F in repair Bell push 5/6 Amps 230 V AC complete all as specified
S&F in repair Socket outlet 3 pin, 5A, flush type all as specified
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified
S&F in repair Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified
S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified
S&F Ceiling rose, 3 terminal PVC/polycarbonate, suitable for 230 V, AC, 50 Hz supply complete all as specified and directed.
S&F call bell ding dong type AC 230 V complete all as specified and directed.
S&F LED panel light fitting, surface mounted, square shaped of size (600x600x70) mm, 34(±10%)watts efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F LED panel light fitting, recessed mounted, rectangle shaped of size (1195x295x70) mm, 36(±10%)watts efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F post top lantern LED type 20/25 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistance complete with driver and lamp complete all as specified and directed
S&F wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 20watt, 1.2 m 3000/6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and integrated inbuilt driver complete complete including making connection complete all as specified and directed.
S&F wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 25watt, 1.2 m 3000/6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and integrated inbuilt driver complete complete including making connection complete all as specified and directed.
S&F LED panel light fitting, recessed mounted, square shaped of size 595x595x65 sqmm, 36(±10%)watts efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete all as specified and directed
S&F LED flood light fitting sqaure shape 150 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp, bracket with impact and corrossion resistant complete with IP 65/66 protection with suitable bolt and nuts, fixing at any height upto 15m complete with making connection complete all as specified and directed
S&F decorative wall light fixture made of polycarbonate suitable for retrofit 9W LED lamp(base B-22) complete with PC diffusor & including one 9W LED lamp(base B-22), 3000/6500K, not less than 90 lumen/watt efficacy including making connection complete all as specified and directed.
S&F integrated round shape 6 watt 220V AC surface type 3000/6500K,efficacy not less than 90 lumen/watt with high efficiency PMMA diffusor soft glare free light complete and integrated inbuilt driver, holders, LED lamps etc including making connection complete all specified and directed
S&F integrated round shape 18 watt 220V AC surface type 3000/6500K,efficacy not less than 90 lumen/watt with high efficiency PMMA diffusor soft glare free light complete and integrated inbuilt driver, holders, LED lamps etc including making connection complete all specified and directed
S&F LED light fitting 9/10W bulkhead luminaires incluing LED light, driver, holder connecting up with three core flexible copper conductor cable of suitable size complete allas specified and directed
S&F Lamp holder PVC/polycarbonate type with back plate complete all as specified
S&F LED 7W lamp(base B-22) 3000/6500K not less than 90 lumen/watt efficacy complete all as specified and directed.
Supplying and fixing in repair PVC/PS/HDPE cable junction box of size 200x160x98mm 230V SP complete with terminals 5 pole, IP 65 protected, dust proof, rust proof with internally embedded gasket with PVC/MS clamp complete all as specified and directed
S&F post top lantern LED type 20 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistance complete with driver and lamp complete all as specified and directed
S&F LED downlighter/spot light fitting, recessed mounted, round shaped of ceiling cut outφ90mm, 03watts efficacy not less than 90 lumen/watt, 3000/6500K extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F LED downlighter/spot light fitting, recessed mounted, round shaped of ceiling cut outφ160mm, 12watts efficacy not less than 90 lumen/watt, 3000/6500K extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F LED landscape/bollard light fitting, round shaped of 0.6m pole size, 10watts, efficacy not less than 90 lumen/watt, extruded Aluminium/ polycarbonate, IP65, PC diffusor, module and inbuilt driver complete including making connection & fixing of pole base with nut and bolt to PCC pedestal/coping complete all as specified and directed.
S&F LED 9Watt Landscape light fitting RGB/multi color complete with die cast aluminium hoising, driver, IP 65, waterproof, with reflector, multicolor complete
S&F in repair LED AC Rope 60 LED/M 6500K/4000K IP65, waterproof, with reflector, multicolor complete C ROPE 60 LED/M Light Accessories complete all as specified and directed.
S&F Decorative, surface mounting, dome shaped pendant in green & black finishes including 01x LED retrofit tube 7 watt, 6500K, efficacy not less than 90 lumen/watt, complete including making connection complete all as specified and directed.
S&F COB LED light 15W heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete all as specified and directed
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 4 sqmm along with earth wire 4.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 4.0 sqmm cable and one length of 4.0 sqmm earth cable will be measured as one running length)
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 6 sqmm along with earth wire 6.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 6.0 sqmm cable and one length of 6.0 sqmm earth cable will be measured as one running length)
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 10 sqmm along with earth wire 10.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 10.0 sqmm cable and one length of 10.0 sqmm earth cable will be measured as one running length)
S&F in replacement sub main four single core PVC copper conductor unsheathed wire multi stranded 10 sqmm along with earth wire 10.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit complete all as specified.(Note :- four lengths of 10.0 sqmm cable and one length of 10.0 sqmm earth cable will be measured as one running length)
S&F in replacement sheet metal encloser double door 4 way TPN 415V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
S&F in replacement sheet metal encloser double door 12 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
S&F in replacement sheet metal encloser single door 2 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
S&F in replacement single pole and neutral enclosure 240V with a two pin and earth plug and socket complete with one double pole MCB 20Amp complete all as specified and direcetd
Supply, installing, test and commissioning (in replacement ) of indoor type LT panel wall mounted, having dimensions not less than 1.0mx0.6mx0.2m with double door made out of 2 mm thick CRCA sheet metal weather proof, with thimble and cable entry boxes with cable glands, having 02 Nos compartments for fixing of meters (01x3phase) having acrylic cover. Panel should covered from all sides with front and back lockable door and hinges complete with copper bus bar of capacity 200 Amps with heat shrinkable PVC sleeve, with an angle iron Base Frame grouted in wall complete including painting with Paint shade of Epoxy based Powder Paint RAL 7032 & DMC insulators and consisting of the following :- (a) Incoming MCCB, 100 Amps, 4pole, 415volts 16KA - 01No (b) Outgoing MCB, 63 Amps, SPN , 230 volts 10KA B Curve- 01 Nos (c) Outgoing MCB, 40 Amps, SPN , 230 volts 10KA B Curve- 01 Nos (d) Outgoing MCB, 10 Amps, SPN , 230 volts 10KA B Curve- 01 No (e) Internal Power & control wiring with suitable PVC insulated FR single core multistranded copper wire cable. (f) Indicating lamp set RYB ,type -01 Set. Note:- 1. Meters as dismentaled during panel replacement to be deposited in E/M store and shall be refixed into the meter boxes after installation. 2. Drawing of meter box panel must be approved by Engr-In Charge before placing order.
Supply, installing, test and commissioning (in replacement ) of indoor type LT panel wall mounted, having dimensions not less than 1.0mx0.6mx0.2m with double door made out of 2 mm thick CRCA sheet metal weather proof, with thimble and cable entry boxes with cable glands, having 02 Nos compartments for fixing of meters (02x3phase) having acrylic cover. Panel should covered from all sides with front and back lockable door and hinges complete with copper bus bar of capacity 200 Amps with heat shrinkable PVC sleeve, with an angle iron Base Frame grouted in wall complete including painting with Paint shade of Epoxy based Powder Paint RAL 7032 & DMC insulators and consisting of the following :- (a) Incoming MCCB, 100 Amps, 4pole, 415volts 16KA - 01No (b) Outgoing MCB, 63 Amps, SPN , 230 volts 10KA B Curve- 02 Nos (c) Outgoing MCB, 10 Amps, SPN , 230 volts 10KA B Curve- 01 No (d) Internal Power & control wiring with suitable PVC insulated FR single core multistranded copper wire cable. (e) Indicating lamp set RYB ,type -01 Set. Note:- 1. Meters as dismentaled during panel replacement to be deposited in E/M store and shall be refixed into the meter boxes after installation. 2. Drawing of meter box panel must be approved by Engr-In Charge before placing order.
S&F in repair MCB 6-32 Amp 240V SP 10 KA ‘B’ series complete all as specified
S&F in repair MCB 40-63 Amp 240V SPN 10 KA ‘C’ series complete all as specified
S&F in repair MCB 415V 40 to 100Amp TPN 10 KA ‘C’ series complete all as specified
S&F RCBO for EARTH LEAKAGE, OVERLOAD & SHORT- CIRCUIT PROTECTION 415 V 40-63A AC type 10kA Four pole 30mA ISI marked complete all as specified
S&F in repair MCCB 415V, FP 63A 16kA complete all as specified
S&F in repair MCCB 415V, FP 100A 16kA complete all as specified
S&F in repair MCCB 415V, FP 125A 16kA complete all as specified
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion including replacement of old unserviceable. Note:- It is mandatory to paint a sqaure shape notice board of yellow color with legible black color letters of earthing mentioned details as below; Cost incurred deemed to be inlcuded in quoted rate:- (i) CA No. (ii) Date of installation after initial testing & Value of earth resistance in Ohm (iii) Date of last testing (iv) Value of earth resistance in Ohm in last test
M&L for painting staircase meter box/LT Panel including removing old paint, cleaning with scrapers of preparation of pld painted surface, complete with filler and making smooth surface, priming with red oxide primer and painting with two coat of synthetic enamel paint with approved color complete all as specified
S&F in repair rigid non metallic PVC conduit medium grade 20 mm nominal dia, 'ISI marked' inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddles, pipe hooks etc for telephone socket, complete all as specified.
S&F in repair rigid non metallic PVC conduit medium grade 25 mm nominal dia, 'ISI marked' inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddles, pipe hooks etc for telephone socket, complete all as specified.
S&F in repair rigid non metallic PVC conduit medium grade 32 mm nominal dia, 'ISI marked' inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddles, pipe hooks etc for telephone socket, complete all as specified.
S&F in repair Hylam sheet cover 3mm thick of size 5"x5" complete with machine screw/ washer with provision of slots for switches, sockets, fan regulators (including refixing of all switches, sockets, fan regulators dismentaled from existing sheets) complete all as specified
S&F in repair Hylam sheet cover 3mm thick of size 8"x5" complete with machine screw/ washer with provision of slots for switches, sockets, fan regulators (including refixing of all switches, sockets, fan regulators dismentaled from existing sheets) complete all as specified
S&F in repair Hylam sheet cover 3mm thick of size 13"x8" complete with machine screw/ washer with provision of slots for switches, sockets, fan regulators (including refixing of all switches, sockets, fan regulators dismentaled from existing sheets) complete all as specified
S& F in repair modular metal flush box 1 module complete all as specified and directed.
S& F in repair modular metal flush box 2 module complete all as specified and directed.
S& F in repair modular metal flush box 3 module complete all as specified and directed.
S& F in repair modular metal flush box 4 module complete all as specified and directed.
S& F in repair modular metal flush box 6 module complete all as specified and directed.
S& F in repair modular metal flush box 8 module complete all as specified and directed.
S& F in repair modular metal flush box 12 module complete all as specified and directed.
S& F in repair white cover plate wih frame 1 module including blanking plate for unused complete all as specified
S& F in repair white cover plate wih frame 2 module including blanking plate for unused complete all as specified
S& F in repair white cover plate wih frame 3 module including blanking plate for unused complete all as specified
S& F in repair white cover plate wih frame 4 module including blanking plate for unused complete all as specified
S& F in repair white cover plate wih frame 6 module including blanking plate for unused complete all as specified
S& F in repair white cover plate wih frame 8 module including blanking plate for unused complete all as specified
S& F in repair white cover plate wih frame12 module including blanking plate for unused complete all as specified
S&F in repair surface mounting box 1 module (for 01x switch) complete all as specified and directed.
S&F in repair surface mounting box 3 module (for 03x switch) complete all as specified and directed.
S&F in repair surface mounting box 5 module (for 05x switch) complete all as specified and directed.
S&F in repair surface mounting box 3 module( 1xsocket, 1xswitch) complete all as specified and directed.
S&F in repair surface mounting box 6 module( 2xsocket, 2xswitch) complete all as specified and directed.
S&F in repair cable connector clamp made of PC (shell) & inner conductor made of nickel plated copper material suitable for 1.5sqmm to 6.00sqmm complete with control lever complete all as specified and directed.
M&L in replacement for earthing circuit wiring (green color) with multi-stranded copper conductor, single core, FRLS, PVC insulated and unsheathed cable of size 1.5 sqmm, run through existing conduit connected to existing terminal/socket point outlet/ MCBs etc complete all specified and directed Note:- One run of cable in existing concealed conduit/surface drawn with suitable saddling shall be measured as one Running metre(RM) and shall deemed to be included in the quoted rate.
M&L in replacement for circuit wiring (red color) with multi-stranded copper conductor, single core, FRLS, PVC insulated and unsheathed cable of size 1.5 sqmm, run through existing conduit connected to existing terminal/socket point outlet/ MCBs etc complete all specified and directed Note:- One run of cable in existing concealed conduit/surface drawn with suitable saddling shall be measured as one Running metre(RM) and shall deemed to be included in the quoted rate.
M&L in replacement for earthing circuit wiring (green color) with multi-stranded copper conductor, single core, FRLS, PVC insulated and unsheathed cable of size 2.5 sqmm, run through existing conduit connected to existing terminal/socket point outlet/ MCBs etc complete all specified and directed Note:- One run of cable in existing concealed conduit/surface drawn with suitable saddling shall be measured as one Running metre(RM) and shall deemed to be included in the quoted rate.
M&L in replacement for earthing circuit wiring (green color) with multi-stranded copper conductor, single core, FRLS, PVC insulated and unsheathed cable of size 4.0 sqmm, run through existing conduit connected to existing terminal/socket point outlet/ MCBs etc complete all specified and directed Note:- One run of cable in existing concealed conduit/surface drawn with suitable saddling shall be measured as one Running metre(RM) and shall deemed to be included in the quoted rate.
M&L in replacement for earthing circuit wiring (green color) with multi-stranded copper conductor, single core, FRLS, PVC insulated and unsheathed cable of size 6.0 sqmm, run through existing conduit connected to existing terminal/socket point outlet/ MCBs etc complete all specified and directed Note:- One run of cable in existing concealed conduit/surface drawn with suitable saddling shall be measured as one Running metre(RM) and shall deemed to be included in the quoted rate.
Dismentaling & taking down of existing single phase energy meter and carried out testing and calibration for accuracy requirements and tempering issue as per standards. in NABL accredited laboratory and submit the report; refixing the calibrated energy meter at same specified location.
Dismentaling & taking down of existing three phase energy meter and carried out testing and calibration for accuracy requirements and tempering issue as per standards. in NABL accredited laboratory and submit the report; refixing the calibrated energy meter at same specified location.
Supplying and fixing in replacement 1100volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6sqmm complete all as specified
Supplying and fixing in replacement PVC/PS/HDPE cable junction box of size 100mmx100mmx60mm complete with terminals 5 pole, IP 65 protected complete all as specified and directed
S&F in repair On load Changeover switch FP 100A 415V AC made of CRCA sheet complete with side handle, connectors, fixing fasteners etc complete all as specified
Supply, laying & testing Tubes(In Repair), 'light grade' galvanised, 40mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors complete all as specfied
Supply, laying & testing Tubes(In Repair), 'light grade' galvanised, 50mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors complete all as specfied
Supplying, laying, jointing & testing, underground XLPE insulated screen PVC bedded, GI steel strip or wire armoured heavy duty LT electric cable with aluminium conductor, 1100Volts grade, cross sectional area 10 sqmm 2 core complete all as specfied
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified
Removing excavated surplus soil to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specfied
M&L for Sand cushioning in trenches for cables including watering and consolidation complete all as specfied
Supply and laying unreinforced pre cast concrete cable cover class LV type 1 flat size 250x150x50 mm for cable protection
M&L Cement concrete in pole/plateform foundations, filling and mass concrete of 1:4:8 type D2 using 40mm graded stone aggregate all as specified and directed.
M&L Providing plain cement concrete type C1 (1:3:6) using 20 mm graded stone aggregate as in coping including necessary form work and finishing exposed surface all as diected.
S&F GI bracket of 40 mm dia bore medium grade 1.2 meter lay bend to shape including MS clamps made out of flat iron of size 40 X 5 mm- 02 Nos and necessary nuts, bolts, washers as required for fixing of street light fitting
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
S&F in repair non metallic PVC casing capping medium grade 10mm x20 mm nominal size, 'ISI marked' inclusive of all fittings and all fixing accessories complete all as specified.
S&F in repair non metallic corrugated flexible PVC conduit medium grade 20 mm nominal size, 'ISI marked' inclusive of all fittings and all fixing accessories complete all as specified.
S&F in repair Bed Switch piano, single pole, one way 6 Amp complete all as specified
S&F in repair Hanging bell push switch, single pole, one way 6 Amp complete all as specified
S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with suitable bolt and nuts complete with making connection complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
S&F in repair non metallic corrugated flexible PVC conduit medium grade 20 mm nominal size, 'ISI marked' inclusive of all fittings and all fixing accessories complete all as specified.
Supplying and fixing in replacement metal halide lamp 150w double ended complete all as specified
Supplying and fixing in replacement metal halide lamp 150w single ended threaded complete all as specified
Supplying and fixing in replacement LED 9Watt 2 pin lamp, G24, 6500K,efficacy not less than 90 Lm /watt complete all as specified
Supplying and fixing in replacement LED 7Watt base B22, 6500K,efficacy not less than 90 Lm /watt complete all as specified
Supplying and fixing in replacement halogen lamp1000w double ended complete all as specified
Supplying and fixing in replacement 1000 W Halogen Bipin T-11 lamp for stage lightening complete all as specified
S&F LED 9Watt Landscape light fitting RGB/multi color complete with die cast aluminium hoising, driver, IP 65, waterproof, with reflector, multicolor complete
S&F in repair LED AC Rope 60 LED/M 6500K/4000K IP65, waterproof, with reflector, multicolor complete C ROPE 60 LED/M Light Accessories complete all as specified and directed.
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 4 sqmm along with earth wire 4.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 4.0 sqmm cable and one length of 4.0 sqmm earth cable will be measured as one running length)
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 6 sqmm along with earth wire 6.0 sqmm copper conductor single core wire connected by common earth in existing surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 6.0 sqmm cable and one length of 6.0 sqmm earth cable will be measured as one running length)
M & L Cement concrete in pole/plateform foundations, filling and mass concrete of 1:4:8 type D2 using 40mm graded stone aggregate all as specified and directed.
M & L Providing plain cement concrete type C1 (1:3:6) using 20 mm graded stone aggregate as in coping including necessary form work and finishing exposed surface all as diected.
Supply, laying & testing Tubes(In Repair), 'light grade' galvanised, 40mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors, on road crossing/on pole complete all as specfied
Supply, laying & testing Tubes(In Repair), 'light grade' galvanised, 50mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors complete all as specfied
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion including replacement of old unserviceable.
S&F in replacement sheet metal encloser single door 2 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
S&F in replacement sheet metal encloser double door 12 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
-do- all as per item No 146 above but 04 way TPN 415 V complete all as specified and directed.
S&F in replacement single pole and neutral enclosure 240V with a two pin and earth plug and socket complete with one single pole MCB 20Amp complete all as specified and directed
S&F in repair MCB 6-32 Amp 240V SP 10 KA ‘C’ series complete all as specified
S&F in repair MCB 20-32 Amp 240V SPN 10 KA ‘C’ series complete all as specified
S&F in repair MCB 415V 40 to 100Amp TPN 10 KA ‘C’ series complete all as specified
S&F in repair MCCB 415V, FP 63A 16kA complete all as specified
S&F in repair MCCB 415V, FP 100A 16kA complete all as specified
Supplying and fixing in replacement 1100volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6sqmm complete all as specified
M&L for dismentaling and taking down complete solar water heater system of 1000/1100 LPD capacity installed at single/double/triple story bldgs, Refixing the same after carrying out following works:- (i) complete cleaning and de-scaling of inlet and out let connections, solar collectors, glasses, hot water tank, cold water tank, make up tank, fittings, fixtures & pipelines etc with suitable chemical agent. (ii) Complete servicing and maintenance (iii) Replacement of unsv spares as deemed necessary such as hot water tank, flat plate collectors, rubber gaskets, nuts, bolts, clamps, flanges etc., repair of minor leakages if any by carrying out minor welding/brazing. (iv) complete testing and to ensure proper functioning & maintaining minimum water temparature i.e.60°C. complete all as specified and directed. Note : (a) Cost of minor spares such as chemical agents, rubber gaskets, nuts, bolts, clamps, flanges etc and minor welding/brazing deemed to be included in the quoted rate. (b) The cost of hot water tank, flat plate collectors shall be paid in respective items from item No 58 to 63.
All as per item No. 155 here-in-before but of capacity 500 LPD.
All as per item No. 155 here-in-before but of capacity 300/200/100 LPD.
Hot water tank of capacity 1000 Ltrs without heat exchanger (Non pressurized) type, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and including sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed.
Hot water tank of capacity 500 Ltrs without heat exchanger (Non pressurized) type, cylindrical shape, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and including manufacturer recommended electrical backup(heating elements & thermostat), sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed. The electrical back-up system should be thermostatically controlled at 50°C complete all as specified and directed.
Hot water tank of capacity 200/300 Ltrs without heat exchanger (Non pressurized) type, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and including sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed.
Hot water tank of capacity 100 Ltrs without heat exchanger (Non pressurized) type, cylindrical shape, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and with manufacturer recommended electrical backup(heating elements & thermostat), sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed. The electrical back-up system should be thermostatically controlled at 50°C complete all as specfied
Hot water tank of capacity 100 Ltrs without heat exchanger (Non pressurized) type, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and including sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed.
Supply & Installation(In repair) of rotational moulded three layered white in colour, polyethylene water storage tanks (cylindrical, vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 Ltrs. including inlet /outlet arrangements & other accessories (of approved make ) etc complete all as specified and directed
Supply & Installation (In repair) 300 litres HDPE water storage tanks Polytuf Three layered white in colour, rotational moulded polyethylene (cylindrical vertical with closed top) , hoisted and fixed in position including inlet /outlet arrangements & other accessories (of approved make ) etc complete all as specified and directed
S&F in Repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe bore dia 15mm and fixed.
S&F in Repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe bore dia 20mm and fixed complete all as specified.
M&L in repair Iron/steel framed work for supporting structure of water tanks, collectors and similar work conforming to Fe-290 Gde-E-165 inclusive of one primer coat, one under coat and one finishing coat of approved paint complete all as specified and directed. complete all as specified and directed
Supply, laying & testing Tubes(In Repair), 'medium grade' galvanised, 15mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors complete all as specfied
Supply, laying & testing Tubes(In Repair), 'medium grade' galvanised, 20mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors complete all as specfied
Supply, laying & testing Tubes(In Repair), 'medium grade' galvanised, 25mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors complete all as specfied
Supply and fixing (In Repair) of aluminium cladding with wire mesh and minimum 50mm thick glasswool of 48kg/m3 density for hot water 15mm GI tubing complete with fittings and fixing materials all as specified and directed
Supply and fixing (In Repair) of aluminium cladding with wire mesh and minimum 50mm thick glasswool of 48kg/m3 density for hot water 20mm GI tubing complete with fittings and fixing materials all as specified and directed
S&F in replacement toughned radiation glass having exellent solar transmittance(minimum 90%), of minimum 4mm size thick & of standard size as per existing arrangement of solar collector complete all as specified.
S&F in replacement rubber hose pipe minimum 50mm thick of size 15mm dia between hot water tank & collector complete all as specified and directed
S&F in replacement of temperature gauge range 0 to 100 °C as per existing size complete all as specified and directed
M&L in repair for gun metal globe or gate valve with iron wheel head screwed both end for iron pipe of size 15mm.
M&L in repair for gun metal globe or gate valve with iron wheel head screwed both end for iron pipe of size 20mm.
M&L in repair for gun metal globe or gate valve with iron wheel head screwed both end for iron pipe of size 25mm.
S&F in replacement heating element 5.0 KW 230V AC, 50 cycle, triangular / round type ISI marked complete with rubber gasket for hot water tank electrical back up system complete all as specified & directed
S&F in replacement heating element 3.0 KW 230V AC, 50 cycle, triangular / round type ISI marked complete with rubber gasket for hot water tank electrical back up system complete all as specified & directed
S&F in replacement thermostat ISI marked stem type 240 Volts, AC supply temp range at least 30 to 75 degree C for geyser/solar water heater system complete all as specified and directed
Supplying and fixing in replacement mild steel Make up tank 5 Ltrs capacity synthetic painted with single coat of primer as per approved dimension matched with ground sample complete all as specified
Labour only for attending door to door, ARMAAN, & user complaints to carryout inspection, cleaning & normal servicing of solar water heating system at various location for faulty connections and making solar water heating system serviceable after testing Note: 1. Cost of minor spares such as rubber gaskets, nuts, bolts, clamps, flanges etc and minor welding/brazing deemed to be included in the quoted rate. 2. Proper record & document to be maintained for each complaint/inspection duly signed by user, cost incurred on this deemed to be included in the quoted rate.
NOTE :- ARMAAN COMPLAINT/DAY TO DAY/DOOR TO DOOR COMPLAINTS:- Complaints regarding repair/replacement to these items to be attended unconditionally. All in cost incurred upon deemed to be included in respective items
Note:- Net contract sum shall be calculated after deduction of Sch of credit.
M/S SODHI ASSOCIATES
M/s NIRMAN BUILDERS
SHARDA ENTERPRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .