Loading…
Loading…
Tender Value
₹12.4 L
EMD Value
₹24,718
Closing Date
1 Oct 2026, 3:00 pm4d left
Executive Engineer
Executive Engineer (Electrical-II), Room No. MZ-108, Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
Shifting and Reinstallation of LT Panels from Low-Lying Areas Including Rerouting of LT Cables in the Academic Area at IIT Delhi.
2026_IIT_926562_1
IITD/WORKS (SP-5402)/2026
Open Tender
Miscellaneous Works
Works
7 days
IIT Delhi Hauz Khas
As per tender documents
9 documents required · 9 mandatory
₹0
₹24,718
1 Oct 2026
17 Sept 2026
2 Oct 2026
17 Sept 2026
1 Oct 2026
17 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling, shifting, fixing, and reinstallation of existing LT panels of the following sizes from the basement to the ground floor, including loading, unloading, transportation, positioning, alignment, fixing with suitable fasteners, grouting with cement concrete at the new location, reconnection of all incoming and outgoing cables, earthing connections, testing, commissioning, and all other allied works required for satisfactory completion of the work as per direction of Engineer in charge. | - | - | - | - |
| 2 | Panel Size:- Height:69 inch ,Width: 38 inch, Depth: 17 inch; having one number Outgoing of 3.5 Core X 70 sqmm, one number Outgoing of 3.5 Core X 95 sqmm, one number Outgoing of 3.5 Core X 35 sqmm, four number Outgoing of 3.5 Core X 50 sqmm, one number incoming cable: 3.5 Core X 240 sqmm | 1 | Each | 369 | ₹369 |
| 3 | Panel Size:- Height:69 inch ,Width: 39 inch, Depth: 17 inch; having four number Outgoing of 3.5 Core X 35 sqmm, one number incoming cable: 3.5 Core X 95 sqmm | 1 | Each | 369 | ₹369 |
| 4 | Panel Size:- Height:85 inch ,Width: 39 inch, Depth: 17 inch; having three number Outgoing of 3.5 Core X 185 sqmm, one number outgoing of 3.5 Core X 240 sqmm, two number outgoing of 3.5 Core X 95sqmm, one number outgoing of 3.5 Core X 150 sqmm, two number incoming cable: 3.5 Core X 400 sqmm | 1 | Each | 428 | ₹428 |
| 5 | Panel Size:- Height:65.5 inch ,Width: 52.5 inch, Depth: 17.5 inch; having three number Outgoing of 3.5 Core X 35sqmm, two number incoming of 3.5 Core X 185 sqmm, four number incoming of 95 sqmm number, outgoing of 3.5 Core X 95sqmm, having one number Outgoing of 3.5 Core X 50 sqmm | 1 | Each | 677 | ₹677 |
| 6 | Panel Size:- Height:72 inch ,Width: 39.5 inch, Depth: 14 inch; having two number Outgoing of 3.5 Core X 50 sqmm, two number outgoing of 3.5 Core X 95 sqmm, one number outgoing of 3.5 Core X 35 sqmm, one number outgoing of 4 Core X 25 sqmm, one number outgoing of 4 Core X 16 sqmm,one number incoming of 3.5 Core X 120 sqmm | 1 | Each | 560 | ₹560 |
| 7 | Dismantling, shifting, fixing, and reinstallation of existing LT panels of the{size:Height:63inch ,Width: 59 inch, Depth: 24 inch}; having four number Outgoing of 3.5 Core X 50 sqmm, incoming cable: 3.5 Core X 185 sqmm height extension, including loading, unloading, transportation, positioning, alignment, fixing with suitable fasteners, grouting with cement concrete at the new location, reconnection of all incoming and outgoing cables, earthing connections, testing, commissioning, and all other allied works required for satisfactory completion of the work as per direction of Engineer in charge. | 1 | Each | 589 | ₹589 |
| 8 | Dismantling, shifting, fixing, and reinstallation of existing 12 way Vertical DB, including positioning, alignment, fixing with suitable fasteners at the new location, reconnection of all incoming cables & outgoing wires, connectors required for extension joint of wires, earthing connections, testing, commissioning, and all other allied works required for satisfactory completion of the work as per direction of Engineer in charge. | 1 | Each | 710 | ₹710 |
| 9 | Dismantling of existing cables of various sizes (3.5 Core X 50/70/95/120/150/185/225/240/300/ 400) sqmm, rearranging / rerouting them as required, and reconnecting the cables in accordance with the shifting of the LT panels to the new location, including all necessary dressing and commissioning for proper operation. | 75 | Mtr. | 924 | ₹69,300 |
| 10 | Dismantling, shifting, fixing, and reinstallation of existing Havells ATS 400A from the basement to the ground floor, including opening nut bolts of cables, glands ,GI, loading, unloading, transportation, positioning, alignment, fixing with suitable fasteners, grouting with cement concrete at the new location, reconnection of all incoming and outgoing cables, earthing connections, testing, commissioning, and all other allied works required for satisfactory completion of the work as per direction of Engineer in charge. | 1 | Each | 128 | ₹128 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
BOQ_973692.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .